0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AA-250-48-44-00-XX

AA-250-48-44-00-XX

  • 厂商:

    LAIRD(莱尔德)

  • 封装:

    -

  • 描述:

    THERMOELECTRCASSYAIR-AIR48V

  • 数据手册
  • 价格&库存
AA-250-48-44-00-XX 数据手册
AA-250-48-44-00-XX Outdoor Thermoelectric Cooler Assemblies Thermoelectric Cooling Units for outdoor enclosures and kiosks The Outdoor Cooler Series is an Air-to-Air thermoelectric assembly (TEA) that uses impingement flow to transfer heat. It offers dependable, compact performance by cooling objects via convection. The AA-250 has 26% higher cooling capacity and a 21% boost in efficiency over standard models with same geometric configurations. Heat is absorbed and dissipated thru custom designed heat exchangers with high aspect ratio, air ducted shrouds and high performance fans. The heat pumping action occurs from custom designed thermoelectric modules that achieve a high coefficient of performance (COP) to minimize power consumption. * Patent Pending This product series has been designed to pass rigorous Telcordia test requirements conducted by our customers, such as earthquake resistance, salt fog, wind-driven rain, high temperature exposure and dust contaminants. This is due to the selection of world class components such as brand fans with the highest degree of environmental protection and lifetime guaranteed waterproof connectors, heavy duty anodization on the high-density heat sinks, overheat protection, and double environmental seals for the thermoelectric modules. FEATURES AND BENEFITS • 244W capacity rated at ΔT = 0ºC, Tambient = 35°C • Wide operating temperature range of -40°C to +55°C • Telcordia GR-487-CORE tested and verified by customers when integrated in telecom outdoor enclosures • Gaskets, connectors, and fans provide a NEMA 4 seal for the enclosure • UL60950 and UL50 approval obtained by customers when integrated in telecom outdoor enclosures • Environmentally friendly solid state operation – no compressor or CFC refrigerants • Cooling and heating in the same unit; optional temperature controller reverses the polarity of current to generate heating Applications • • • • Americas: +1.919.597.7300 Europe: +46.31.420530 Asia: +86.755.2714.1166 ets.sales@lairdtech.com www.lairdtech.com/thermal Outdoor telecom enclosures Outdoor kiosks and displays Harsh condition electronic cabinets Battery cabinets AA-250-48-44-00-XX Outdoor Thermoelectric Cooler Assemblies PERFORMANCE Qc vs ΔT 250 Qc (W) 200 150 100 50 0 0 5 10 15 20 25 30 35 40 45 ΔT (°C) Specifications AA-250-48-44-00-XX Technical Technology Thermoelectric (TE) modules, forced air, closed loop (non-mixing), filter-less, non-refrigerant Cooling at dT = 0°C, and nominal / float voltage.1 Heating 2 Voltage (nominal / maximum) 244/262 W (832/894 BTU/hr) 250W (853 BTU/hr) 48/60 VDC 6 COP (Coefficient of Performance) 85% Grounding (all voltages) Positive or negative Current draw, ±10% (nominal / startup) Weight 6.1/7.8 A 6.3 kg (16.9 lbs) Panel mounting Through (from external side) ≥70,000 hours Fan life (L10 at +40°C) Connector type (on unit / mating side) Terminal block with cage clamps (AWG 28-12) Hi-pot testing 707 VDC Environmental Temperature range 3 (external ambient) -40°C to +55°C (-40°F to +131°F) Temperature range (internal enclosure) -20°C to +55°C (-4°F to +131°F) Degree of protection, enclosure 4 Degree of protection, unit internal side NEMA 4 (IP55) 5 Degree of protection, unit external side 5 Sound level (1m distance) Over-Temp Thermostat (internal and external side heat sink) IP54 IP54 63 dB(A) 75°C ± 6°C (accessory) Cooling capacities at nominal / float voltage are rated at external temperatures of +35°C and +50°C respectively. Float voltage is defined at 27 VDC Calculated heating capacity is rated at external temperature of -40°C, nominal voltage, and ΔT = -45°C. 3) Controller function shall not operate the external fan during heating mode. 4) The highest environmental protection level requires an external shroud and is defined as the protection level for the enclosure. 5) Rating for unit without protective shroud. 6) Max ripple 5%. 1) 2) Note: The specified performance of any Laird cooling unit is dependent on how it is handled and incorporated into the final product. This includes elements such as the system design, insulation design, and assembly method. While Laird Technologies is able to provide general guidelines based upon our experience, it is ultimately the responsibility of the device manufacturer to validate each product and its performance for its intended use. AA-250-48-44-00-XX Outdoor Thermoelectric Cooler Assemblies Isometric Drawings 350 152 260 99 55 48 105 400 153 Mounting Hole Location & Hardware 300 350 152 168 Electrical connection 48VDC (cage clamp) THR-DS-AA-250-48-44-00-XX Any information furnished by Laird Technologies, Inc. and its agents is believed to be accurate and reliable. All specifications are subject to change without notice. Responsibility for the use and application of Laird Technologies materials rests with the end user, since Laird Technologies and its agents cannot be aware of all potential uses. Laird Technologies makes no warranties as to the fitness, merchantability or suitability of any Laird Technologies materials or products for any specific or general uses. Laird Technologies shall not be liable for incidental or consequential damages of any kind. All Laird Technologies products are sold pursuant to the Laird Technologies’ Terms and Conditions of sale in effect from time to time, a copy of which will be furnished upon request. © Copyright 2012 Laird Technologies, Inc. All Rights Reserved. Laird, Laird Technologies, the Laird Technologies Logo, and other marks are trade marks or registered trade marks of Laird Technologies, Inc. or an affiliate company thereof. Other product or service names may be the property of third parties. Nothing herein provides a license under any Laird Technologies or any third party intellectual property rights.
AA-250-48-44-00-XX 价格&库存

很抱歉,暂时无法提供与“AA-250-48-44-00-XX”相匹配的价格&库存,您可以联系我们找货

免费人工找货