Non Magnetic Connectors
Product Catalog
belfuse.com/cinch
NON-MAGNETIC RF CONNECTORS
Introduction
Johnson’s Non-Magnetic Connector Additions Offer Solutions to MR Imaging Technology
Johnson, a product line of Cinch Connectivity Solutions, has expanded the connector product groups in its popular line of Non-Magnetic
RF coaxial connectors and cable assemblies.
MCX and MMCX micro-miniature connectors have been added to satisfy the needs of the RF coil manufacturers that are building smaller
coils for MRI equipment. Customized flex coils and array coils can image smaller parts of the body such as wrists, feet, hands and other
appendages.
The Non-Magnetic MCX and MMCX is the perfect micro-miniature connector for small multichannel coil packages as they provide a
positive snap-on coupling design with high mating cycles for rugged, high density connectivity.
The Type N Non-Magnetic connector provides a perfect RF solution for high Tesla fields considered for future designs. These deep tissue
MR images will require the rugged interface of the N connector as well as the tri-alloy plating to eliminate inter-modulation issues.
All the connectors in Johnson’s Non-Magnetic line are made from high purity copper alloys assuring no ferrous materials are in the
connectors manufactured. Cinch Connectivity Solutions continues to work with our customers to develop new solutions as the MR
industry transitions to high-end field applications and improved resolution at greater physical depths within the body.
Products are offered through authorized distributors and international sales channels including a direct sales force and a network of
manufacturers’ representatives. For more information, please call (800) 247-8256.
About Johnson
Cinch Connectivity Solutions, located in Waseca, MN, manufactures Johnson® RF Connectors such as Ultra-miniature (UMC), Microminiature (MCX, MCX 75, MMCX and SMP), Sub-miniature (SMA, SMB, SMB Mini-75 Ohm, SMK) and Medium (Type N) in the most
popular styles including PC Board Mount, End Launch, Bulkhead Mount and Cable Mounts (Flexible, Semi-rigid and Conformable).
Table of Contents
MMCX Non-Magnetic RF Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
MCX Non-Magnetic RF Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
SMA Non-Magnetic RF Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
SMB Non-Magnetic RF Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Type N Non-Magnetic RF Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Assembly Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
The Johnson Combination
2
MRI Connectors and Modular Customization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30
Competitor Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31
NON-MAGNETIC RF CONNECTORS
MMCX Non-Magnetic RF Connectors
ELECTRICAL SPECIFICATIONS
Impedance:
50 Ohms
Frequency Range
0-6 GHz
VSWR: (f = GHz)
.047 dia flexible
RG-178, RG-316, RG-316 DS
Working Voltage
170 VRMS at sea level
Dielectric Withstanding Voltage
500 VRMS at sea level
Insulation Resistance
1000 megohms minimum
Contact Resistance (milliohms maximum)
Center Contact (straight cabled connectors, uncabled receptacles)
Center Contact (right angle cabled connectors)
Outer Contact
Braid to Body
Corona Level:
Straight Cable Connectors
Right Angle Cable Connectors
1.20
1.20
1.14 + .07f
1.25
Initial
After Environmental
5.0
5.0
1.0
1.5
8.0
15.0
1.5
N/A
190 volts min at 70,000 feet
Insertion Loss(dB maximum, tested at 1 GHz)
Straight Cable Connectors
Right Angle Cable Connectors
Uncabled Receptacles
0.1
0.2
N/A
RF Leakage (dB minimum tested at 2.5 GHz)
Flexible Cable Connectors
RF High Potential Withstanding Voltage
-60 dB
tested at 4 and 7 MHz
VRMS minimum
400
MECHANICAL SPECIFICATIONS
Engagement Design
Series MMCX
Engagement Force
8 lbs. max axial engagement, 1.4 lbs. min axial disengagement
Contact Retention
2.0 pounds min. axial force, 1 inch-ounce min. torque (uncabled receptacles)
Cable Retention
Connectors for .047 flexible
Connectors for RG-178
Connectors for RG-316
Connectors for RG-316 DS
Connectors for .086 Semi-Rigid
*Or cable breaking strength whichever is less.
Durability:
Axial Force* (lbs)
Torque (in-oz)
3.5
7.0
20.0
25.5
30.0
N/A
N/A
N/A
N/A
16
500 cycles minimum
ENVIRONMENTAL SPECIFICATIONS (Meets or Exceeds the Applicable Paragraph of MIL-RF-39012)
Temperature Range
Thermal Shock
Corrosion
Shock
Vibration
Moisture Resistance
-65°C to +165°C
MIL-STD-202, Method 107, Condition C (Except -55°C to 115°C)
MIL-STD-202, Method 101, Condition B
MIL-STD-202, Method 213, Condition B
MIL-STD-202, Method 204, Condition D
MIL-STD-202, Method 106
belfuse.com/cinch
3
NON-MAGNETIC RF CONNECTORS
MMCX Non-Magnetic RF Connectors
For Flexible Cable and PC Mount
Straight Crimp Type Plug - Solder or Crimp Contact - Captivated Contact
Cable Type
Gold Plated
“A”
“B”
Termination
RG-316/U, 188, 161, 174
135-9403-001
.509 (12.93)
.173 (4.39)
Crimp Sleeve
RG-178/U, 196
135-9402-001
.462 (11.73)
.137 (3.48)
Crimp Insert
.047 Dia. Flex
135-9436-001
.462 (11.73)
.137 (3.48)
Crimp Insert
See assembly instructions page 22
Right Angle Crimp Type Plug - Captivated Contact
Cable Type
Gold Plated
“A”
“B”
Termination
RG-316/U, 188, 187, 179, 161, 174
135-9403-101
.412 (10.46)
.334 (8.48)
Crimp Sleeve
RG-178/U, 196
135-9402-111
.412 (10.46)
.334 (8.48)
Crimp Sleeve
.047 Dia. Flex
135-9436-101
.354 (8.99)
.276 (6.98)
Crimp Insert
See assembly instructions page 23
Straight Jack Receptacle
Gold Plated
“A”
135-9701-201
.115 (2.92)
135-9701-211
.068 (1.73)
Mounting hole layout figure 1 on page 5
4
NON-MAGNETIC RF CONNECTORS
MMCX Non-Magnetic RF Connectors
For PC Mount
Right Angle Jack Receptacle
Gold Plated
“A”
135-9701-301
.155 (3.94)
135-9701-311
.068 (1.73)
Mounting hole layout figure 1 on page 5 below
End Launch Jack Receptacle - Surface Contact
Gold Plated
Packaging
135-9711-801
Stock
135-9711-802
Tape and Reel 1000 pcs/reel
Recommended land pattern figure 2 on page 5
Mounting Hole Layout
belfuse.com/cinch
5
NON-MAGNETIC RF CONNECTORS
MCX Non-Magnetic RF Connectors
ELECTRICAL SPECIFICATIONS
Impedance:
50 Ohms
Frequency Range
0-6 GHz
VSWR: (f = GHz)
Working Voltage (VRMS maximum)
Straight Cable Connectors
Right Angle Cable Connectors
RG-178 cable
RG-316 cable
Uncabled Receptacles
1.17 + .09f
13 + .04f
N/A
1.07 + .06f
1.07 + .04f
N/A
Connectors for Cable Type
Sea Level
70K Feet
250
335
65
85
RG-178
RG-316
Dielectric Withstanding Voltage (VRMS minimum at sea level
Connectors for RG-178, Uncabled Receptacles
Connectors for RG-316, Uncabled Receptacles
Insulation Resistance
750
1000
10,000 megohms minimum
Contact Resistance (milliohms maximum)
Center Contact (straight cabled connectors, uncabled receptacles)
Center Contact (right angle cabled connectors)
Outer Contact
Braid to Body
Initial
After Environmental
5.0
5.0
1.0
1.0
8.0
15.0
1.5
N/A
Corona Level (Volts minimum at 70,000 feet)
Connectors for RG-178 Uncabled Receptacles
Connectors for RG-316, Uncabled Receptacles
190
250
Insertion Loss (dB maximum, tested at 1 GHz)
Straight Cable Connectors
Right Angle Cable Connectors
Uncabled Receptacles
0.1
0.2
N/A
RF Leakage (dB minimum tested at 2.5 GHz)
Cable connectors
Uncabled receptacles
RF High Potential Withstanding Voltage
-55
N/A
(VRMS minimum, tested at 4 and 7 MHz)
Connectors for RG 178
Connectors for RG 316
Uncabled Receptacles
MECHANICAL SPECIFICATIONS
500
700
600
Engagement Design
Compatible with CECC 22220, Series MCX
Engagement / Disengagement Force
5.6 pounds maximum axial force / 8 pounds maximum axial force, 1 pound min
Contact Retention
2.3 pounds min. axial force (captivated contacts); 1 inch-ounce min. torque (uncabled receptacles)
Cable Retention
Connectors for RG178
Connectors for RG316
Connectors for RG316 DS
*Or cable breaking strength whichever is less.
Durability:
Axial Force* (lbs)
Torque (in-oz)
10
20
25
N/A
N/A
N/A
500 cycles minimum
ENVIRONMENTAL SPECIFICATIONS (Meets or Exceeds the Applicable Paragraph of MIL-RF-39012)
Temperature Range
Thermal Shock
Corrosion
Shock
Vibration
Moisture Resistance
6
-65°C to +165°C
MIL-STD-202, Method 107, Condition C (Except -55°C to 115°C)
MIL-STD-202, Method 101, Condition B
MIL-STD-202, Method 213, Condition B
MIL-STD-202, Method 204, Condition D
MIL-STD-202, Method 106
NON-MAGNETIC RF CONNECTORS
MCX Non-Magnetic RF Connectors
Straight Crimp Type Plug - Solder or Crimp Contact - Captivated Contact
Cable Type
Gold Plated
RG-178
133-9402-001
RG-316/U, 188, 174
133-9403-001
RG-316 DS, 188 DS
133-9404-001
See assembly instructions page 24
Straight Crimp Type Jack Receptacle
Cable Type
Gold Plated
RG-316
133-9303-001
Right Angle Crimp Type Plug - Captivated
Cable Type
Gold Plated
Silver Plated
RG-316/U, 188, 174
133-9403-101
133-9403-104
RG-316 DS, 188 DS
133-9404-101
RG-178/U, 196
133-9402-101
See assembly instructions page 24
belfuse.com/cinch
7
NON-MAGNETIC RF CONNECTORS
MCX Non-Magnetic RF Connectors
For Flexible Cables
Straight Jack Receptacle
Gold Plated
Silver Plated
“A”
133-9701-201
133-9701-204
.155 (3.94)
133-9701-211
Mounting hole layout figure 4 on page 10
Straight Plug Receptacle, PCB Mount
Gold Plated
133-9801-201
Straight Surface Mount, Jack Assembly
Gold Plated
133-9711-201
8
.110 (2.79)
NON-MAGNETIC RF CONNECTORS
MCX Non-Magnetic RF Connectors
For Flexible Cables
Straight Jack Receptacle - .100" Layout
Gold Plated
133-9701-231
Mounting hole layout figure 3 on page 10
Right Angle Jack Receptacle
Gold Plated
Silver Plated
“A”
133-9701-301
133-9701-304
.155 (3.94)
133-9701-311
.110 (2.79)
Mounting hole layout figure 4 on page 10
End Launch Jack Receptacle - Round Contact
Gold Plated
Board Thickness
133-9701-801
.062 (1.57)
MCX Non-Magnetic RF Connectors
For PC Mount
Mounting Holes Layout
belfuse.com/cinch
9
NON-MAGNETIC RF CONNECTORS
SMA Non-Magnetic RF Connectors
ELECTRICAL SPECIFICATIONS
Impedance:
50 Ohms
Frequency Range
Flexible cable connectors
Uncabled Receptacles
VSWR: (f = GHz)
Working Voltage (VRMS maximum)
0-12.4 GHz
0-18.0 GHz
Straight Cable Connectors
Right Angle Cable Connectors
RG-316
RG-58
Uncabled Receptacles
1.15 + .02f
1.15 + .01f
N/A
1.15 + .03f
1.15 + .02f
N/A
Connectors for Cable Type
Sea Level
70K Feet
250
335
65
85
RG-316
RG-58, Uncabled Receptacles
Dielectric Withstanding Voltage (VRMS minimum at sea leve)l
Connectors for RG-316
Connectors for RG-58, Uncabled Receptacles
Insulation Resistance
750
1000
5000 megohms minimum
Contact Resistance (milliohms maximum)
Center Contact (straight cabled connectors, uncabled receptacles)
Center Contact (right angle cabled connectors)
Outer Contact
Braid to Body
Initial
After Environmental
3.0
4.0
2.0
0.5
4.0
6.0
N/A
N/A
Corona Level (Volts minimum at 70,000 feet)
Connectors for RG-316
Connectors for RG-58, Uncabled Receptacles
190
250
Insertion Loss (dB maximum, tested at 1 GHz)
Straight Cable Connectors
Right Angle Cable Connectors
Uncabled Receptacles
0.06 √f(GHz), tested at 6 GHz
0.15 √f(GHz), tested at 6 GHz
N/A
RF Leakage (dB minimum tested at 2.5 GHz)
Cable connectors
Uncabled Receptacles
RF High Potential Withstanding Voltage
-60 dB
N/A
(VRMS minimum, tested at 4 and 7 MHz)
Connectors for RG-316
Connectors for RG-58,Uncabled receptacles
500
670
MECHANICAL SPECIFICATIONS
Engagement Design
MIL-STD-348, Series SMA
Engagement / Disengagement Force
2 inch-pounds maximum
Contact Retention
6 lb minimum axial force (captivated contacts); 4 inch-ounce minimum torque (uncabled receptacles)
Mating Torque
7 to 10 inch-pounds
Coupling Proof Torque
15 inch-pounds minimum
Coupling Nut Retention
60 pounds minimum
Cable Retention
Durability:
Connectors for RG-316
Connectors for RG-58
*Or cable breaking strength whichever is less.
500 cycles minimum
Axial Force* (lbs)
Torque (in-oz)
20
40
N/A
N/A
ENVIRONMENTAL SPECIFICATIONS (Meets or Exceeds the Applicable Paragraph of MIL-RF-39012)
Temperature Range
Thermal Shock
Corrosion
Shock
Vibration
Moisture Resistance
10
-65°C to +165°C
MIL-STD-202, Method 107, Condition B
MIL-STD-202, Method 101, Condition B
MIL-STD-202, Method 213, Condition I
MIL-STD-202, Method 204, Condition D
MIL-STD-202, Method 106
NON-MAGNETIC RF CONNECTORS
SMA Non-Magnetic RF Connectors
For Flexible and Semi-Rigid Cable
Straight Solder Type Plug, Semi Rigid Cable
Gold Plated
142-9003-201
Straight Crimp Type Plug (3-piece) - Captivated Contact
Cable Type
VSWR & Freq. Range
Gold Plated
RG-316/U, 188, 174
1.15 + .02f (GHz) 0-12.4 GHz
142-9403-011
RG-316 DS, 188 DS
1.15 + .02f (GHz) 0-12.4 GHz
142-9404-011
RG-58/U, 141
1.15 + .01f (GHz) 0-12.4 GHz
142-9407-001
See assembly instructions page 25
Right Angle Crimp Type Plug - Captivated Contact
Cable Type
VSWR & Freq. Range
Gold Plated
Silver Plated
142-9403-104
RG-316/U, 188, 174
1.15 + .03f (GHz) 0-12.4 GHz
142-9403-101
RG-316 DS, 188 DS
1.15 + .03f (GHz) 0-12.4 GHz
142-9404-101
RG-58/U, 141
1.15 + .02f (GHz) 0-12.4 GHz
142-9407-101
142-9407-104
See assembly instructions page 25
belfuse.com/cinch
11
NON-MAGNETIC RF CONNECTORS
SMA Non-Magnetic RF Connectors
For PC Mount
Straight Crimp Type Blukhead Jack (3-piece) - Captivated Contact
Cable Type
VSWR & Freq. Range
Gold Plated
RG-316/U, 188, 174
1.15 + .02f (GHz) 0-12.4 GHz
142-9303-411
Frequency Range
Gold Plated
“A”
0-18 GHz
142-9701-201
.155 (3.94)
0-18 GHz
142-9701-211
.110 (2.79)
See assembly instructions page 25
Mounting hole layout figure 5 on page 14
Straight Jack Receptacle
Mounting hole layout figure 6 on page 14
Straight Plug Receptacle
Frequency Range
Gold Plated
0-18 GHz
142-9801-201
Mounting hole layout figure 6 on page 14
12
NON-MAGNETIC RF CONNECTORS
SMA Non-Magnetic RF Connectors
For PC Mount
Right Angle Receptacle
Frequency Range
Gold Plated
0-18 GHz
142-9701-301
Mounting hole layout figure 6 on page 14
End Launch Receptacle - Round Contact
Frequency Range
Gold Plated
Board Thickness
0-10 GHz
142-9701-801
.062 (1.57)
Frequency Range
Gold Plated
Board Thickness
0-10 GHz
142-9701-811
.062 (1.57)
End Launch Receptacle - Tab Contact
Mounting hole layout
belfuse.com/cinch
13
NON-MAGNETIC RF CONNECTORS
SMB Non-Magnetic RF Connectors
ELECTRICAL SPECIFICATIONS
Impedance:
50 Ohms
Frequency Range
Connectors
VSWR: (f = GHz)
Working Voltage (VRMS maximum)
0 - 4 GHz
Straight Cable Connectors
Right Angle Cable Connectors
RG-316
Uncabled Receptacles
1.25 + .04f
N/A
1.35 + .04f
N/A
Connectors for Cable Type
Sea Level
70K Feet
335
85
RG-316, Uncabled Receptacles
Dielectric Withstanding Voltage (VRMS minimum at sea leve)l
Connectors for RG-316, Uncabled Receptacles
1000
Insulation Resistance
1000 megohms minimum
Contact Resistance (milliohms maximum)
Center Contact (straight cabled connectors, uncabled receptacles)
Center Contact (right angle cabled connectors)
Outer Contact
Braid to Body
Initial
After Environmental
6.0
12.0
1.0
.10
8.0
16.0
1.5
N/A
Corona Level (Volts minimum at 70,000 feet)
Connectors for RG-316
Uncabled Receptacles
250
N/A
Insertion Loss (dB maximum, tested at 1.5 GHz)
Straight Cable Connectors
Right Angle Cable Connectors
Uncabled Receptacles
0.3 dB
0.6 dB
N/A
Cable Connectors
Uncabled Receptacles
-55 dB
N/A
RF Leakage (dB minimum tested at 2.5 GHz)
RF High Potential Withstanding Voltage
(VRMS minimum, tested at 4 and 7 MHz)
Connectors for RG-316
Uncabled Receptacles
MECHANICAL SPECIFICATIONS
700
600
Engagement Design
MIL-STD-348, Series SMB
Engagement / Disengagement Force
2 pounds min to 14 pounds maximum axial force / 4 lb minimum axial force (captivated contacts)
Contact Retention
4 lb minimum axial force (captivated contacts); 1 inch-ounce minimum torque (uncabled receptacles)
Cable Retention
Connectors for RG316
*Or cable breaking strength whichever is less.
Durability:
Axial Force* (lbs)
Torque (in-oz)
20
N/A
500 cycles minimum
ENVIRONMENTAL SPECIFICATIONS (Meets or Exceeds the Applicable Paragraph of MIL-RF-39012)
Temperature Range
Thermal Shock
Corrosion
Shock
14
-65°C to +165°C
MIL-STD-202, Method 107, Condition B
MIL-STD-202, Method 101, Condition B
MIL-STD-202, Method 213, Condition I
NON-MAGNETIC RF CONNECTORS
SMB Non-Magnetic RF Connectors
For Flexible Cable
Straight Crimp Type Plug - Solder or Crimp Captivated Contact
Cable Type
Gold Plated
RG-316/U, 188, 174, 179, 187
131-9403-001
RG-316 DS, 188 DS, 179 DS, 187 DS
131-9404-001
See assembly instructions page 27
Straight Crimp Type Plug (3-piece), Solder or Crimp Captivated Contact
Cable Type
Gold Plated
RG-316/U, 188, 174, 179, 187
131-9403-021
RG-316 DS, 188 DS, 179 DS, 187 DS
131-9404-021
See assembly instructions page 27
Right Angle Crimp Type Plug - Captivated Contact
Cable Type
Gold Plated
RG-316/U, 188, 174, 179, 187
131-9403-101
RG-316 DS, 188 DS, 179 DS, 187 DS
131-9404-101
See assembly instructions page 27
belfuse.com/cinch
15
NON-MAGNETIC RF CONNECTORS
SMB Non-Magnetic RF Connectors
For Flexible Cable
Straight Jack Receptacle
Gold Plated
“A”
131-9701-201
.155 (3.94)
131-9701-211
.095 (2.41)
Mounting hole layout figure 7 on page 18
Straight Bulkhead Jack, Crimp Type, Flexible Cable
Gold Plated
131-9303-401
Right Angle Jack Receptacle
Gold Plated
131-9701-301
Mounting hole layout figure 7 on page 18
16
NON-MAGNETIC RF CONNECTORS
SMB Non-Magnetic RF Connectors
For Flexible Cable
Mounting hole layout
belfuse.com/cinch
17
NON-MAGNETIC RF CONNECTORS
Type N Non-Magnetic RF Connectors
ELECTRICAL SPECIFICATIONS
Impedance:
50 Ohms
Frequency Range
Flexible Cabled and Receptacles
0-11 GHz
VSWR: (f = GHz)
0-11 GHz
Straight Flexible Cabled
Uncabled Receptacles
Working Voltage (VRMS maximum)
1.3 max
N/A
Connectors for Cable Type
Sea Level
70K Feet
RG-55/U
RG-214, LMR-400 Cabled
Uncabled Receptacles
335
1000
1000
85
250
250
Dielectric Withstanding Voltage (VRMS minimum at sea leve)l
RG-55
RG-214, LMR-400 Cabled
Uncabled Receptacles
Insulation Resistance
1000
2500
2500
5000 megohms minimum
Contact Resistance (milliohms maximum)
Straight Cabled (non-captivated)
Straight Cabled (captivated)
Uncabled Receptacles
Outer contact
Braid to body
Initial
After Environmental
1.0
2.5
1.0
0.2
0.05
1.5
3.0
1.5
N/A
N/A
Corona Level (Volts minimum at 70,000 feet)
RG-55
RG-214, LMR-400 Cabled
Uncabled Receptacles
250
500
N/A
Insertion Loss (dB maximum, tested at 9 GHz)
Straight Cable Connectors
Right Angle Cable Connectors
Uncabled Receptacles
0.15 max
0.30 max
N/A
RF Leakage (dB minimum tested at 2.5 GHz)
Cable connectors
Uncabled receptacles
RF High Potential Withstanding Voltage
90
N/A
(VRMS minimum, tested at 4 and 7 MHz)
RG-55
RG-214, LMR-400 Cabled
Uncabled Receptacles
670
1500
1500
IMP3
Typically < -90 dBm
(tested per IEC Guidelines using 20 W inputs swept over 1930-1990 MHz
MECHANICAL SPECIFICATIONS
Cabled Connectors
Uncabled Receptacles
Cable Retention (minimum*)
Axial Force (lbs)
6
6
Torque (in-oz)
N/A
4
Axial Force (lbs)
Torque (in-oz)
45
90
N/A
N/A
RG-55 Cabled
RG-214, LMR-400 Cabled
*Or cable breaking strength whichever is less.
ENVIRONMENTAL SPECIFICATIONS
18
Engagement Design
MIL-STD-348A, Series N
Bulkhead Mounting Nut Torque
15 inch-pounds recommended
Engagement / Disengagement Force
6 inch-pounds maximum
Coupling Proof Torque
15 inch-pounds minimum
Durability
500 Cycles minimum
Coupling Nut Retention
100 pounds minimum
Mating Torque
7 to 10 inch-pounds
Contact Retention
minimum - captivated contacts only
NON-MAGNETIC RF CONNECTORS
Type N Non-Magnetic RF Connectors
For Flexible Cable
Straight Crimp Type Plug – Solder or Crimp Contact
Cable Type
VSWR & Freq. Range
Tri-Alloy Plated Figure
RG-55/U, 142, 223, 400
1.30 Max, 0-11 GHz
138-9408-007
A
LMR-400, BELDEN 9913
1.30 Max, 0-11 GHz
138-9449-007
B
See assembly instructions page 28
Right Angle Crimp Type Plug – Captivated Contact
Cable Type
VSWR & Freq. Range
Tri-Alloy Plated
“A”
“B”
RG-55/U, 142, 223, 400
1.35 Max, 0-9 GHz
1.50 Max, 9-11 GHz
138-9408-107
1.253 (31.83)
1.003 (25.48)
RG-9/U, 214
1.35 Max, 0-9 GHz
1.50 Max, 9-11 GHz
138-9418-107
1.365 (34.67)
1.115 (28.32)
See assembly instructions page 28
Straight Crimp Type Bulkhead Jack – Solder or Crimp Contact
Cable Type
VSWR & Freq. Range
Tri-Alloy Plated
“A”
RG-55/U, 142, 223, 400
1.30 Max, 0-11 GHz
138-9308-407
.943 (23.95)
LMR-400, BELDEN 9913
1.30 Max, 0-11 GHz
138-9349-407
.997 (25.32)
See assembly instructions page 28
Mounting hole layout figure 8 on page 21
belfuse.com/cinch
19
NON-MAGNETIC RF CONNECTORS
Type N Non-Magnetic RF Connectors
For Bulkhead and Flange Mount
Rear Mount Bulkhead Jack Receptacle
Freq. Range
Tri-Alloy Plated
0-11 GHz
138-9701-407
Mounting hole layout figure 8 on page 21 (below)
4-Hole Flange Mount Jack Receptacle – Flush Dielectric
Freq. Range
Tri-Alloy Plated
0-11 GHz
138-9701-607
Mounting hole layout figure 8 on page 21 (below)
Mounting Hole Layout
Asia Pacific
+86 21 5442 7668
ccs.asia.sales@as.cinch.com
Europe, Middle East & Africa
+44 (0) 1245 342060
CinchConnectivity@eu.cinch.com
North America
+1 507.833.8822
ccsorders@us.cinch.com
belfuse.com/cinch
© 2017 Cinch Connectivity Solutions
CCS Johnson Non Magnetic Catalog rev 3 062017