High Performance Thermal-Magnetic Circuit Breakers 446/447/449
Description
Single pole thermal-magnetic circuit breakers with tease-free, trip-free,
press-to-reset snap action mechanism and special dual button manual
release which avoids the danger of unintended disconnection (M-type
TM CBE to EN 60934). Surface mounted, compact design available
with fast acting, standard and delayed switching characteristics.
Options include auxiliary contact and remote electrical disconnection.
Typical applications
Heavy duty vehicles, battery systems, process control.
1
446-...
Ordering information
Type No.
446 single pole base mounting, fast characteristic curve
447 single pole base mounting, medium delay characteristic curve
449 single pole base mounting, delayed characteristic curve
Terminal design, mounting
K screw terminals M12, insertion nuts M8
Manual release
H standard
Version
N general application (type 446 only)
FN general application (types 447 and 449 only)
Auxiliary contacts (optional)
Si 2 electrically separate auxiliary contacts
with screw terminals M3.5 and
blade terminals DIN 46244-C-MS-S
Remote trip (optional)
FA24 DC 24 V coil voltage
Current ratings
30...400 A type 446
100...400 A type 447
125...500 A type 449
447 - K - H - FN - ... - ... - 400 A
ordering example
Standard current ratings and typical internal resistance values
Internal
resistance (Ω)
Current
ratings (A)
30
0.006
100
< 0.002
40
0.0048
125
< 0.001
Type 446:
Internal
resistance (Ω)
Type 447:
50
0.0038
160
< 0.001
60
0.0028
225
< 0.001
70
0.0025
300
< 0.001
80
0.0023
400
< 0.001
90
0.0019
Type 449:
100
0.0016
125
< 0.001
125
< 0.001
160
< 0.001
150
< 0.001
225
< 0.001
170
< 0.001
315
< 0.001
200
< 0.001
350
< 0.001
225
< 0.001
400
< 0.001
500
< 0.001
250
< 0.001
300
< 0.001
350
< 0.001
400
< 0.001
For further details please see: www.e-t-a.de/ti_e
Voltage rating
DC 28 V
Current rating range
type 446: 30...400 A
type 447: 100...400 A
type 449: 125...500 A
Auxiliary circuit
10 A
Electrical remote disconnection (-FA)
operating voltage
DC 12 V or DC 24 V
operating current
approx. 18 A or 12 A
max. pulse time
10 ms < tON < 20 ms / tOFF > 10 s
switching time
< 20 ms
Typical life
1,000 operations at IN
2,000 operations mechanical
Ambient temperature
-55...+75 °C (-67...+167 °F)
Insulation co-ordination
Overvoltage category
(IEC 60664)
pollution degree 2 / 3
Resulting in a rated impulse withstand
voltage of 500 V at DC 28 V to DIN
EN 60664-1
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating area
AC 1,500 V
main circuit to
auxiliary contacts
AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity Icn 10,000 A
Degree of protection
operating area IP40
(IEC 60529/DIN 40050)
terminal area IP00
Vibration
to VG 95210, sheet 19,
IEC 60068-2-6, test Fc:
without aux. contacts: 10 g (56-500 Hz), ± 0.76 mm (10-55 Hz)
with auxiliary contacts: 4 g (56-500 Hz), ± 0.30 mm (10-56 Hz)
Shock
to VG 95210, sheet 28,
IEC 60068-2-27, test Ea:
without aux. contacts: 50 g (11 ms)
with auxiliary contacts: 20 g (11 ms)
Corrosion
96 hours at 5 % salt mist
to VG 95210, sheet 2,
IEC 60068-2-11, test Ka
Humidity
240 hours at 95 % RH
to VG 95210, sheet 7,
IEC 60068-2-3, test C
Mass
approx. 850 g
Approvals
Authority
only with 50 % ON duty
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.
2248
449-...
Technical data
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
Please be informed that we have minimum ordering quantities to be
observed.
Current
ratings (A)
447-...
UL
Standard
Rated voltage
Current ratings
UL 1077
DC 28 V
up to 400 A
Type 446/
Type 447
CSA
C22.2 No 235
DC 28 V
up to 400 A
Type 449:
UL
UL 1077
DC 28 V
100...350 A
CSA
C22.2 No 235
DC 28 V
100…350 A
95345, part 15
DC 28 V
125...500 A
www.e-t-a.de
Bw
1
High Performance Thermal-Magnetic Circuit Breakers 446/447/449
Dimensions
Internal connection diagrams
447-K-H-FN-Si-FA (
ø20
15 ± 1,5
0,5 ON
OFF
ø26
5
4
hex nut M8 or 5/16"-18-NC
14 mm/.551 in. usable thread length
tightening torque max. 3.5 Nm
60 ± 0.3
170
140
current rating in A
AUS OFF
EIN ON
AUS OFF
28 V DC
12
43.5
100
10
1
12
0.1
flat head screw ISO 1580-M4x6
tightening torque max. 0.55 Nm
0.01
This is a metric design and millimeter dimensions take precedence ( mm )
inch
0.001
1
2
20
40 60 80 100
4 6 8 10
… times rated current
Typical time/current characteristics
447-…
DC
449-… 125…400 A
DC
449-… 500 A (50% ON duty/60 min)
10000
1000
1000
1000
100
10
Trip time in seconds
10000
Trip time in seconds
10000
Trip time in seconds
1
line 1
line 1
100
10
100
10
1
1
1
0.1
0.1
0.1
0.01
0.01
0.01
0.001
1
2
+75 °C
+167 °F
4 6 8 10
20
0.001
40 60 80 100
… times rated current
+23 °C
+73.4 °F
1
2
4 6 8 10
20
40 60 80 100
… times rated current
DC
0.001
1
2
4 6 8 10
20
40 60 80100
… times rated current
-55 °C
-67 °F
Circuit breakers with remote disconnection facility will trip 10% faster
.
2
www.e-t-a.de
2248