NE
W
!
F250 (Ø250 X 99L)
NMBTC.COM / 818.341.3355
Characteristic Curves
In H2O (Pa)
800
3
3,100rpm
700
2,900rpm
2,500rpm
2
2,400rpm
500
400
300
1
200
100
0
0
200
200
400
400 600
600
800 1,000
1000 [CFM]
800
1,200 1,400
[m3/h]
Impellers
Static Pressure
600
Air Flow
Outline
General Specifications
Motor Protection:
inch
Units: (mm)
Locked Rotor, Reverse Polarity
ROTATION
Insulation Resistance:
10M Ω min measured with 500V DC between all leads
shorted together and case
˚
3.78
(4xM4 P.C.D. 96.0)
90
0.23
(6.0 )
˚
Failure Rate: 10%
40°C 70,000 Hours (L10)
1.1
R2 0
8
Expected Life
25.61
(650 ± 20 )
-30°C ~ +70°C (Operating)
-40°C ~ +80°C (Storage)
6.77
(F172.0)
6.39
(F162.4)
9.85
(F250.0 )
4.53
(F115.0)
90
Dielectric Withstand Voltage: AC 700V 1 minute
Allowable Ambient Temperature Range:
15˚
3.93
(99.8)
2.86
(72.8)
1.02
(25.9)
1.59
(40.5)
Material
Impeller : Steel
Bearing : Ball Bearing
Lead Wire : UL1015, AWG18, +Red, -Black,
Speed Control = Yellow,
Speed Signal = White
Specifications
Rated
Voltage
MODEL
Operating
Current
Voltage
Input
Speed
Power
Max.
Air Flow
Max. Static
(V)
(V)
(A)*1
(W)*1
(min-1)*1
F250A3-072-D0730
48
30 ~ 72
3.40
163.2
3100
862
24.41
2.98
F250A4-072-D0720
48
30 ~ 72
1.85
88.8
2500
693
19.63
1.96
F250A5-072-D0520
24
18 ~ 30
6.05
145.2
2900
806
22.83
F250A6-072-D0520
24
18 ~ 30
3.50
84.0
2400
668
18.92
Rotation: Clockwise
*1: Average Values in Free Air and Rated Voltage Condition
Noise
Mass
Pressure
CFM*1 (m3/min)*1 in H2O (Pa)*1
(dB)*1
(g)
745
81
2400
490
74
2400
2.59
646
78
2400
1.84
460
73
2400
x.x
很抱歉,暂时无法提供与“F250A4-072-D0720”相匹配的价格&库存,您可以联系我们找货