CLM-6-30-80-18-AA02-F2-3 数据手册
CLM-6 Product Datasheet
Preliminary
CLM-6 COB Arrays
White LED
Features:
• High lumen output and efficacy typical
Table of Contents
• Over 370 lm, 114 LPW @ 3000K, 25ºC
Technology Overview. . . . . . 2
• Over 400 lm, 125 LPW @ 5000K, 25ºC
Test Specifications . . . . . . . . . 2
• Complete CCT range 2700K, 3000K, 3500K, 4000K, 5000K and 6500K
• 80 or 90 CRI min. up to 95 min. in warm white
Chromaticity Bins. . . . . . . . . . 3
• 3-step MacAdam Ellipse color binning accuracy
Product Ordering & Shipping
Part Numbers. . . . . . . . . . . . . . 4
• Excellent optical emission uniformity and color over angle consistency
Product Typical Flux. . . . . . . . 5
• Superior thermal conductivity for uniform heat spreading
Operating Characteristics . . 8
• Exceptional long term color stability
• Environmentally friendly: RoHS and REACh compliant
Optical and Electrical Characteristics. . . . . . . . . . . . . . . . . . . . . . . 9
Spectra. . . . . . . . . . . . . . . . . . . 12
Mechanical Dimensions. . . 13
Packaging Information. . . . 13
Handling Notes. . . . . . . . . . . 14
Applications
• Spotlights/Track Lights
• Shop Lighting
• Down Lights
• Hospitality Lighting
• MR16 Replacement lamps
• Architectural and Specialty
1
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
Technology Overview
Luminus XNova™ Chip-on-Board (COB) LED series offers a complete lighting class solution designed for high performance illumination
applications. The selection covers a wide lumen range from less than 400lm to over 10,000lm, all major color temperatures and can
deliver color rendering greater than 97 at 2700K and 3000K and R9 equal to 95. These breakthroughs allow illumination engineers and
designers to develop lighting solutions with maximum efficacy, brightness and overall quality.
Reliability
Designed from the ground up, the XNova™ COB LED is one of
the most reliable light sources in the world today. Having
passed a rigorous suite of environmental and mechanical stress
tests, including mechanical shock, vibration, temperature
cycling and humidity. Only then are the devices qualified for
use in a wide range of lighting application including some of the
most demanding commercial applications. Delivered with fully
qualified LM80 test data and TM21 lifetime results that certify
lumen maintenance at 35,000 hours or more, XNova™ COB LEDs
are ready for the toughest challenges.
UL Recognized Compliance
XNova COB arrays are tested in accordance with ANSI/UL 8750
to ensure safe operation for their intended applications.
REACh & RoHS Compliance
All LED products manufactured by Luminus are REACh and
RoHS compliant and free of hazardous materials, including lead
and mercury.
Understanding XNova™ COB LED Test Specifications
Every XNova™ LED is fully tested to ensure it meets the high quality standards customers have come to expect from Luminus’ products.
Traceability
Chromaticity Bin Range
Each XNova COB LED is marked with a 2D bar code that contains
a unique serial number. With this serial number, Luminus has
the ability to provide customers with actual test data
measurements for a specific LED. In addition, the 2D bar code is
linked to manufacturing date codes that enables traceability of
production processes and materials.
Chromaticity binning delivers color consistency for every order.
Standard products are delivered with a 3-step MacAdam ellipse.
This ensures color performance matching in the application. For
the most demanding application, Luminus is one of only a few
companies that can provide a 2-step ellipse bin. These tightly
controlled, small distribution bins provide customers
predictable, repeatable colors.
Testing Temperature
XNova™ COB products are measured at temperatures typical for
the LED operating in the fixture. Each device is tested at 85ºC
junction temperature eliminating the need to scale data sheet
specifications to real world situations.
2
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
Chromaticity Bin Structure
Chromaticity Bins: 1931 CIE Curve
0.46
ANSI C78.377-2008
2-step Ellipse
3-step Ellipse
5-step Ellipse
0.44
2700K
3000K
3500K
0.42
Black Body
4000K
CIE y
0.4
5000K
0.38
0.36
6500K
0.34
0.32
0.3
0.3
0.32
0.34
0.36
0.38
0.4
0.42
0.44
0.46
0.48
0.5
CIE x
CLM-6 White Chromaticity Bins
The following tables describe the ANSI bin center points, the orientation angle for the MacAdam ellipse (θ °), and the maximum radii for
the ellipses. The ANSI Bin is provided for reference.
Center Point
5-step Bin
3-step Bin
2-step Bin
Angle
CCT
CIEx
CIEy
θ (°)
a
b
a
b
a
b
2700K
0.4578
0.4101
53.7
0.0054
0.0028
0.0081
0.0042
0.0135
0.007
3000K
0.4338
0.403
53.2
0.00556
0.00272
0.00834
0.00408
0.0139
0.0068
3500K
0.4073
0.3917
54
0.00618
0.00276
0.00927
0.00414
0.01545
0.0069
4000K
0.3818
0.3797
53.7
0.00626
0.00268
0.00939
0.00402
0.01565
0.0067
5000K
0.3447
0.3553
59.6
0.00548
0.00236
0.00822
0.00354
0.0137
0.0059
6500K
0.3123
0.3282
58.57
0.00446
0.0019
0.00669
0.00285
0.01115
0.00475
*Note:
Luminus maintains a +/- 0.005 tolerance on chromaticity (CIEx and CIEy) measurements.
3
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
Product Ordering and Shipping Part Number Nomenclature
All CLM-6 products are packaged and labeled with part numbers as outlined in the table on page 5 and 6. Luminus may include any
smaller chromaticity bin that is contained in the larger bin as part of the ordered part. When shipped, each package will contain only a
single flux and chromaticity bin. The part number designation is as follows:
CLM
CLM-6
XX
6
NN
XX
QQPP
FG
W
Product Family
Light Emitting
Surface Diameter
Color
Temperature1
Color Rendering Index (CRI)2
Voltage
(typical)3
Package
Configurator
Flux Bin
Chromaticity
Bin
CLM: Special
6.3 : LES
Diameter (mm)
Color
See Note 1
below
CRI See Table
Below
Volts
AA00
(Basic package)
Lumens
See page 4 for
bins
Note 1: NN nomenclature corresponds to the following:
27 = 2700K
30 = 3000K
35 = 3500K
40 = 4000K
50 = 5000K
65 = 6500K
Note 2: XX Voltage typical values are
27V typical
18V typical
9V typical
Color Temperature, CRI and R9 Values
Color Temperatures
Note:
XX Value
CRI
R9
2700K, 3000K, 3500K, 4000K, 5000K, 6500K
80
>80
>0
2700K, 3000K
90
>90
>50
Luminus part numbers may be accompanied by prefixes or suffixes. The most common is the “Rev01” suffix indicating a part is fully released
and carries a full warranty. These additional characters may appear on shipping labels, packing slips and invoices. In all cases the basic part
number described above will always be included.
4
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
CLM-6 Flux Bin Part Numbers
The following tables describe the products with a maximum and minimum output flux measured at 120mA and specified at 85ºC. The
values at 25ºC are calculated and shown for reference only. All product is measured and specified at 85ºC junction temperature. Luminus
may choose to ship a smaller chromaticity bin in an order for a larger.
CCT
Output Flux (lm)
Reference
Typ.
(85ºC)
Min.
(85ºC)
(calculated)
315
290
245
Color
Rendering
Index
Ordering Part Number
Typ.
CRI (min.)
3-step MacAdam Ellipse
2-step MacAdam Ellipse
350
80
CLM-6-27-80-27-AA00-F2-3
CLM-6-27-80-27-AA00-F2-2
225
270
90
CLM-6-27-90-27-AA00-F2-3
CLM-6-27-90-27-AA00-F2-2
235
215
260
95
CLM-6-27-95-27-AA00-F2-3
CLM-6-27-95-27-AA00-F2-2
330
310
370
80
CLM-6-30-80-27-AA00-F2-3
CLM-6-30-80-27-AA00-F2-2
280
260
310
90
CLM-6-30-90-27-AA00-F2-3
CLM-6-30-90-27-AA00-F2-2
260
240
290
95
CLM-6-30-95-27-AA00-F2-3
CLM-6-30-95-27-AA00-F2-2
340
315
380
80
CLM-6-35-80-27-AA00-F2-3
CLM-6-35-80-27-AA00-F2-2
290
265
320
90
CLM-6-35-90-27-AA00-F2-3
CLM-6-35-90-27-AA00-F2-2
360
335
400
80
CLM-6-40-80-27-AA00-F2-3
CLM-6-40-80-27-AA00-F2-2
305
280
335
90
CLM-6-40-90-27-AA00-F2-3
CLM-6-40-90-27-AA00-F2-2
Output Flux (lm)
Reference
Color
Rendering
Index
Typ.
(85ºC)
Min..
(85ºC)
(calculated)
5000K
370
340
6500K
370
340
2700K
3000K
3500K
4000K
CCT
(25ºC)
Typ.
CRI (min.)
5-step MacAdam Ellipse
3-step MacAdam Ellipse
400
80
CLM-6-50-80-27-AA00-F2-5
CLM-6-50-80-27-AA00-F2-3
400
80
CLM-6-65-80-27-AA00-F2-5
CLM-6-65-80-27-AA00-F2-3
(25ºC)
*Note:
Luminus maintains a +/- 6% tolerance on flux measurements.
Luminus maintains a +/- 2% tolerance on CRI measurements.
5
PDS-002350 Rev 04
Part Number
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6
Product
Datasheet
(Part
#) Product
Datasheet
Preliminary
CLM-6 Flux Bin Part Numbers
The following tables describe the products with a maximum and minimum output flux measured at 180mA and specified at 85ºC. The
values at 25ºC are calculated and shown for reference only. All product is measured and specified at 85ºC junction temperature. Luminus
may choose to ship a smaller chromaticity bin in an order for a larger.
CCT
Output Flux (lm)
Reference
Typ.
(85ºC)
Min..
(85ºC)
(calculated)
315
290
245
Color
Rendering
Index
Ordering Part Number
Typ.
CRI (min.)
3-step MacAdam Ellipse
2-step MacAdam Ellipse
350
80
CLM-6-27-80-18-AA00-F2-3
CLM-6-27-80-18-AA00-F2-2
225
270
90
CLM-6-27-90-18-AA00-F2-3
CLM-6-27-90-18-AA00-F2-2
235
215
260
95
CLM-6-27-95-18-AA00-F2-3
CLM-6-27-95-18-AA00-F2-2
330
310
370
80
CLM-6-30-80-18-AA00-F2-3
CLM-6-30-80-18-AA00-F2-2
280
260
310
90
CLM-6-30-90-18-AA00-F2-3
CLM-6-30-90-18-AA00-F2-2
260
240
290
95
CLM-6-30-95-18-AA00-F2-3
CLM-6-30-95-18-AA00-F2-2
340
315
380
80
CLM-6-35-80-18-AA00-F2-3
CLM-6-35-80-18-AA00-F2-2
290
265
320
90
CLM-6-35-90-18-AA00-F2-3
CLM-6-35-90-18-AA00-F2-2
360
335
400
80
CLM-6-40-80-18-AA00-F2-3
CLM-6-40-80-18-AA00-F2-2
305
280
335
90
CLM-6-40-90-18-AA00-F2-3
CLM-6-40-90-18-AA00-F2-2
Output Flux (lm)
Reference
Color
Rendering
Index
Typ.
(85ºC)
Min..
(85ºC)
(calculated)
5000K
370
340
6500K
370
340
2700K
3000K
3500K
4000K
CCT
(25ºC)
Typ.
CRI (min.)
5-step MacAdam Ellipse
5-step MacAdam Ellipse
400
80
CLM-6-50-80-18-AA00-F2-5
CLM-6-50-80-18-AA00-F2-3
400
80
CLM-6-65-80-18-AA00-F2-5
CLM-6-65-80-18-AA00-F2-3
(25ºC)
*Note:
Luminus maintains a +/- 6% tolerance on flux measurements.
Luminus maintains a +/- 2% tolerance on CRI measurements.
6
PDS-002350 Rev 04
Part Number
© 2015 Luminus Devices, Inc. - All Rights Reserved
(Part
#) Product
Datasheet
CLM-6
Product
Datasheet
Preliminary
CLM-6 Flux Bin Part Numbers
The following tables describe the products with a maximum and minimum output flux measured at 360mA and specified at 85ºC. The
values at 25ºC are calculated and shown for reference only. All product is measured and specified at 85ºC junction temperature. Luminus
may choose to ship a smaller chromaticity bin in an order for a larger.
CCT
Output Flux (lm)
Reference
Typ.
(85ºC)
Min..
(85ºC)
(calculated)
315
290
245
Color
Rendering
Index
Ordering Part Number
Typ.
CRI (min.)
3-step MacAdam Ellipse
2-step MacAdam Ellipse
350
80
CLM-6-27-80-9-AA00-F2-3
CLM-6-27-80-9-AA00-F2-2
225
270
90
CLM-6-27-90-9-AA00-F2-3
CLM-6-27-90-9-AA00-F2-2
235
215
260
95
CLM-6-27-95-9-AA00-F2-3
CLM-6-27-95-9-AA00-F2-2
330
310
370
80
CLM-6-30-80-9-AA00-F2-3
CLM-6-30-80-9-AA00-F2-2
280
260
310
90
CLM-6-30-90-9-AA00-F2-3
CLM-6-30-90-9-AA00-F2-2
260
240
290
95
CLM-6-30-95-9-AA00-F2-3
CLM-6-30-95-9-AA00-F2-2
340
315
380
80
CLM-6-35-80-9-AA00-F2-3
CLM-6-35-80-9-AA00-F2-2
290
265
320
90
CLM-6-35-90-9-AA00-F2-3
CLM-6-35-90-9-AA00-F2-2
360
335
400
80
CLM-6-40-80-9-AA00-F2-3
CLM-6-40-80-9-AA00-F2-2
305
280
335
90
CLM-6-40-90-9-AA00-F2-3
CLM-6-40-90-9-AA00-F2-2
Output Flux (lm)
Reference
Color
Rendering
Index
Typ.
(85ºC)
Min..
(85ºC)
(calculated)
5000K
370
340
6500K
370
340
2700K
3000K
3500K
4000K
CCT
(25ºC)
Typ.
CRI (min.)
5-step MacAdam Ellipse
5-step MacAdam Ellipse
400
80
CLM-6-50-80-9-AA00-F2-5
CLM-6-50-80-9-AA00-F2-3
400
80
CLM-6-65-80-9-AA00-F2-5
CLM-6-65-80-9-AA00-F2-3
(25ºC)
*Note:
Luminus maintains a +/- 6% tolerance on flux measurements.
Luminus maintains a +/- 2% tolerance on CRI measurements.
7
PDS-002350 Rev 04
Part Number
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
CLM-6 Operating Characteristics1
27V Operating Conditions
Parameter
Symbol
Typical
Maximum
Unit
Forward Current
If
120
240
mA
Forward Voltage
Vf
27
31
V
Symbol
Typical
Maximum
Unit
Forward Current
If
180
360
mA
Forward Voltage
Vf
18
20
V
Symbol
Typical
Maximum
Unit
Forward Current2
If
360
720
mA
Forward Voltage
Vf
9
11
V
Symbol
Typical
Maximum
Unit
3.24
6.5
W
105
ºC
2
18V Operating Conditions
Parameter
2
9V Operating Conditions
Parameter
Operating Conditions
Parameter
Power
Operating Case Temperature3
Tc
Light Emitting Surface Diameter
LES
6.3
mm
Thermal Resistance (junction-to-case)
Qjc
2.33
ºC/W
Junction Temperature
Tj
Viewing Angle
140
120
ºC
Degree
Note 1: Ratings are based on operation at a constant junction temperature of Tj = 85ºC.
Note 2: To prevent damage refer to operating conditions and derating curves for appropriate maximum operating conditions
Note 3: Maximum operating case temperature combined with maximum drive current defines the total maximum operating condition for the device. To
prevent damage, please follow derating curves for all operating conditions.
Note 4: CLM-6 COB LEDs are designed for operation up to an absolute maximum forward drive current as specified above. Refer to the current vs. case
temperature derating curves for further information.
Note 5: Caution must be taken not to stare at the light emitted from these LEDs. Under special circumstances, the high intensity could damage the eye.
8
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
CLM-6 Optical & Electrical Characteristics (27V)
Relative Output Flux vs. Forward Current @ 85ºC
Forward Current vs. Forward Voltage @ 85ºC
200.0%
300
180.0%
250
140.0%
Forward Current (mA)
Relative Luminous Flux
160.0%
120.0%
100.0%
80.0%
60.0%
200
150
100
40.0%
50
20.0%
0.0%
0
0
50
100
150
200
250
300
23
24
25
26
Forward Current (mA)
28
29
30
Change in Voltage vs. Juction Temperature
120.0%
29
100.0%
28.5
Forward Voltage (V)
Relative Luminous Flux
Relative Output Flux vs. Junction Temperature
80.0%
60.0%
40.0%
28
27.5
27
26.5
20.0%
26
0.0%
5
15
25
35
45
55
65
75
85
95
5
105
15
25
35
Change in CIEx vs. Junction Temp. (3000K, 80CRI)
0.015
0.015
0.01
0.01
0.005
0.005
0
0
Δy
0.02
-0.005
-0.005
-0.01
-0.01
-0.015
-0.015
-0.02
15
25
35
45
55
65
75
Junction Temperature (ºC)
9
PDS-002350 Rev 04
55
65
75
85
95
105
Change in CIEy vs. Junction Temp. (3000K, 80CRI)
0.02
5
45
Junction Temperature (ºC)
Junction Temperature (ºC)
Δx
27
Forward Voltage (V)
© 2015 Luminus Devices, Inc. - All Rights Reserved
85
95
105
-0.02
5
15
25
35
45
55
65
Junction Temperature (ºC)
75
85
95
105
(Part
#) Product
Datasheet
CLM-6
Product
Datasheet
Preliminary
CLM-6 Optical & Electrical Characteristics (18V)
Relative Output Flux vs. Forward Current @ 85ºC
Forward Current vs. Forward Voltage @ 85ºC
400
200.0%
180.0%
350
140.0%
Forward Current (mA)
Relative Luminous Flux
160.0%
120.0%
100.0%
80.0%
60.0%
40.0%
300
250
200
150
100
50
20.0%
0
0.0%
50
100
150
200
250
300
15.5
350
16
16.5
17
17.5
18
18.5
19
19.5
Forward Voltage (V)
Forward Current (mA)
Relative Output Flux vs. Junction Temperature
Change in Voltage vs. Juction Temperature
19
120.0%
18.5
Forward Voltage (V)
Relative Luminous Flux
100.0%
80.0%
60.0%
40.0%
18
17.5
20.0%
0.0%
5
15
25
35
45
55
65
75
85
95
17
105
50
60
70
Junction Temperature (ºC)
Change in CIEx vs. Junction Temp. (3000K, 80CRI)
0.015
0.01
0.01
0.005
0.005
0
0
Δy
0.015
Δx
0.02
-0.005
-0.005
-0.01
-0.01
-0.015
-0.015
-0.02
15
25
35
45
55
65
75
Junction Temperature (ºC)
10
PDS-002350 Rev 04
90
100
Change in CIEy vs. Junction Temp. (3000K, 80CRI)
0.02
5
80
Junction Temperature (ºC)
© 2015 Luminus Devices, Inc. - All Rights Reserved
85
95
105
-0.02
5
15
25
35
45
55
65
Junction Temperature (ºC)
75
85
95
105
CLM-6 Product Datasheet
Preliminary
CLM-6 Optical & Electrical Characteristics (9V)
Relative Output Flux vs. Forward Current @ 85ºC
Forward Current vs. Forward Voltage @ 85ºC
200.0%
800
180.0%
700
140.0%
Forward Current (mA)
Relative Luminous Flux
160.0%
120.0%
100.0%
80.0%
60.0%
40.0%
600
500
400
300
200
100
20.0%
0.0%
0
0
100
200
300
400
500
600
700
800
7.5
8
8.5
Forward Current (mA)
Relative Output Flux vs. Junction Temperature
10
10
100.0%
9.5
Forward Voltage (V)
Relative Luminous Flux
9.5
Change in Voltage vs. Juction Temperature
120.0%
80.0%
60.0%
40.0%
9
8.5
8
20.0%
0.0%
5
15
25
35
45
55
65
75
85
95
105
7.5
5
15
25
35
45
Junction Temperature (ºC)
0.015
0.015
0.01
0.01
0.005
0.005
0
0
Δy
0.02
-0.005
-0.005
-0.01
-0.01
-0.015
-0.015
-0.02
15
25
35
45
55
65
75
Junction Temperature (ºC)
11
PDS-002350 Rev 04
65
75
85
95
105
Change in CIEy vs. Junction Temp. (3000K, 80CRI)
0.02
5
55
Junction Temperature (ºC)
Change in CIEx vs. Junction Temp. (3000K, 80CRI)
Δx
9
Forward Voltage (V)
© 2015 Luminus Devices, Inc. - All Rights Reserved
85
95
105
-0.02
5
15
25
35
45
55
65
Junction Temperature (ºC)
75
85
95
105
CLM-6 Product Datasheet
Preliminary
CLM-6 Optical & Electrical Characteristics
Typical Spectrum
120.00%
100.00%
Relative Intensity
80.00%
Warm White
60.00%
Neutral White
Cool White
40.00%
3000K-90CRI
3000K-97CRI
20.00%
0.00%
400
450
500
-20.00%
550
600
650
700
750
800
Wavelength (nm)
Typical Polar Radiation Pattern
Typical Angular Radiation Pattern
120%
100%
Relative Intensity (%)
80%
60%
40%
20%
0%
-80
-60
-40
-20
0
20
Anglular Displacement (Degrees)
12
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
40
60
80
CLM-6 Product Datasheet
Preliminary
Mechanical Dimensions
Shipping Container
Each bag is boxed for
easier storage/stacking
•
•
•
Trays are sealed in an
anti-static bag
Label
Customer
Part Number
Lot ID
Quantity
13
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
5 trays are stacked together
with one tray as a cover
CLM-6 Product Datasheet
Preliminary
Handling Notes for XNova COBs
XNova products are designed for robust performance in general lighting application. However, care must be taken when handling and
assembling the LEDs into their fixtures. To avoid damaging XNova COBs please follow these guide lines.
The following is an overview of the application notes detailing some of the practices to follow when working with these devices. More
detailed information is available on the Luminus web site at www.luminus.com.
General Handling
Electrical Contact
Devices are made to be lifted or carried with tweezers on two
adjacent corners opposite the contact pads. At no time should
the devices be handled by or should anything come in contact
with the light emitting surface (LES) area. This area includes the
yellow colored circular area and the ring surrounding it. There
are electrical connections under the LES which if damaged will
cause the device to fail.
XNova COBs are designed with contact pads on their top
surface. These pads are clearly marked with + and – polarity.
Wires can be soldered to the contact pads for electrical
connections or other solderless connector products are
available.
In addition, the ring frame itself should not be used for moving,
lifting or carrying the device. Also do not attach any optics or
mechanical holders to the ring as it is not capable to handle the
mechanical stress.
If wires are being soldered to the COB product, we recommend
attaching these wires prior to mounting the devices to a heat
sink. Please contact Luminus for specific recommendations on
how to solder wires if not familiar with the standard practice.
Luminus can also offer design recommendations for jigs to
allow easily soldering multiple products in rapid succession.
Static Electricity
Chemical Compatibility
XNova COBs are electronic devices which can be damaged by
electrostatic discharge (ESD). Please use appropriate measures
to assure the devices do not experience ESD during their
handling and or storage. ESD protection guidelines should be
used at all times when working with XNova COBs.
The resin material used to form the LES can getter hydrocarbons
from the surrounding environment. As a results, certain
chemical compounds are not recommended for use with the
XNova products. Use of these compounds can cause damage to
the light output of the device and may permanently damage
the device. Please refer to www.luminus.com for a list of the
compounds not recommended for use with the XNova COB
products.
Storage: XNova products are delivered in ESD shielded bags
and should be stored in these bags until used.
Assembly: Individuals handling XNova COBs during assembly
should be trained in ESD protection practices. Assemblers
should maintain constant conductive contact with a path to
ground by means of a wrist strap, ankle straps, mat or other ESD
protection system.
Transporting: When transporting the devices from one
assembly area to another, ESD shielded carts and carriers should
be used.
14
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
Thermal Interface Material (TIM)
Proper thermal management is critical for successful operation
of any LED system. Excess operating temperature can reduce
the light output of the device. And excessive heating can cause
permanent damage to the device. Proper TIM material is a
crucial component for effective heat transfer away from the LED
during normal operation. Please refer to www.luminus.com for
specific recommendations for TIM solutions.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Luminus Devices:
CLM-6-50-80-18-AA00-F2-3 CLM-6-50-80-18-AA00-F2-5 CLM-6-30-90-18-AA00-F2-2 CLM-6-30-80-18-AA00-F2-2
CLM-6-40-90-18-AA00-F2-3 CLM-6-40-80-18-AA00-F2-3 CLM-6-40-90-18-AA00-F2-2 CLM-6-40-80-18-AA00-F2-2
CLM-6-30-95-27-AA00-F2-2 CLM-6-30-80-18-AA00-F2-3 CLM-6-30-95-27-AA00-F2-3 CLM-6-30-90-18-AA00-F2-3
CLM-6-27-95-27-AA00-F2-2 CLM-6-40-80-27-AA00-F2-3 CLM-6-40-90-27-AA00-F2-3 CLM-6-35-90-18-AA00-F2-3
CLM-6-27-95-27-AA00-F2-3 CLM-6-35-80-18-AA00-F2-2 CLM-6-30-80-9-AA02-F2-3 CLM-6-35-80-18-AA00-F2-3
CLM-6-35-90-18-AA00-F2-2 CLM-6-30-80-9-AA02-F2-2 CLM-6-40-90-27-AA00-F2-2 CLM-6-40-80-27-AA00-F2-2
CLM-6-27-95-18-AA00-F2-2 CLM-6-27-95-18-AA00-F2-3 CLM-6-50-80-27-AA00-F2-3 CLM-6-65-80-18-AA00-F2-3
CLM-6-50-80-9-AA00-F2-3 CLM-6-50-80-27-AA00-F2-5 CLM-6-30-80-18-AA02-F2-3 CLM-6-27-80-9-AA00-F2-2
CLM-6-30-90-9-AA00-F2-2 CLM-6-30-90-9-AA00-F2-3 CLM-6-30-80-18-AA02-F2-2 CLM-6-35-90-9-AA00-F2-2 CLM6-35-90-9-AA00-F2-3 CLM-6-65-80-9-AA00-F2-3 CLM-6-65-80-9-AA00-F2-5 CLM-6-40-80-9-AA00-F2-3 CLM-6-3090-27-AA00-F2-3 CLM-6-50-80-9-AA00-F2-5 CLM-6-30-80-27-AA00-F2-3 CLM-6-30-80-27-AA00-F2-2 CLM-6-30-9027-AA00-F2-2 CLM-6-27-80-9-AA00-F2-3 CLM-6-40-80-9-AA00-F2-2 CLM-6-30-95-18-AA00-F2-3 CLM-6-27-80-27AA00-F2-3 CLM-6-27-90-27-AA00-F2-3 CLM-6-30-95-9-AA00-F2-3 CLM-6-35-90-27-AA00-F2-3 CLM-6-35-80-27AA00-F2-3 CLM-6-30-80-27-AA02-F2-3 CLM-6-27-80-27-AA00-F2-2 CLM-6-27-90-27-AA00-F2-2 CLM-6-30-95-18AA00-F2-2 CLM-6-35-90-27-AA00-F2-2 CLM-6-30-80-27-AA02-F2-2 CLM-6-30-95-9-AA00-F2-2 CLM-6-35-80-27AA00-F2-2 CLM-6-27-95-9-AA00-F2-3 CLM-6-35-80-9-AA00-F2-3 CLM-6-30-80-9-AA00-F2-3 CLM-6-40-90-9-AA00F2-2 CLM-6-27-90-18-AA00-F2-2 CLM-6-65-80-27-AA00-F2-3 CLM-6-65-80-27-AA00-F2-5 CLM-6-27-80-18-AA00F2-2 CLM-6-27-80-18-AA00-F2-3 CLM-6-27-90-18-AA00-F2-3 CLM-6-27-95-9-AA00-F2-2 CLM-6-35-80-9-AA00-F2-2
CLM-6-30-80-9-AA00-F2-2 CLM-6-40-90-9-AA00-F2-3 CLM-6-27-90-9-AA00-F2-2 CLM-6-65-80-18-AA00-F2-5
CLM-6-27-90-9-AA00-F2-3