Ordering information
DC-DC Converters Power Module type
DAS50
DA
1
S
2
O
50
3
4
05
5
1Series name
2Single output
3Output wattage
4Input voltage
F :DC88 - 370V
48 :DC36 - 72V
5Output voltage
R
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
DAS50F05
50
5V 10A
DAS50F12
50.4
12V 4.2A
DAS50F24
50.4
24V 2.1A
DAS504805
50
5V 10A
DAS504812
50.4
12V 4.2A
SPECIFICATIONS
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
DAS
ENVIRONMENT
SAFETY
OTHERS
MODEL
VOLTAGE[V]
CURRENT[A]
EFFICIENCY[%]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +85C *1
RIPPLE[mVp-p]
-10 - 0C *1
0 to +85C *1
RIPPLE NOISE[mVp-p]
-10 - 0C *1
0 to +85C
TEMPERATURE REGULATION[mV]
-10 to +85C
*2
DRIFT[mV]
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CASE SIZE/WEIGHT
COOLING METHOD
DAS50F05
DAS50F12
DAS50F24
DC88 - 370
0.5typ (DCIN 130V, Io=100%) 0.25typ (DCIN 260V, Io=100%)
82typ
82typ
82typ
0.3max (By UL, CSA, VDE and DEN-AN)
5
12
24
10
4.2
2.1
20max
48max
96max
40max
100max
150max
80max
120max
120max
140max
160max
160max
150max
200max
200max
190max
230max
230max
85max
204max
408max
95max
228max
456max
20max
48max
96max
200max (DCIN 88V, Io=100%)
Fixed (TRM pin open)t10% adjustable by external VR
DAS504805
DAS504812
DC36 - 72
1.30typ (DCIN 48V, Io=100%) 1.28typ (DCIN 48V, Io=100%)
80typ
82typ
5
10
20max
40max
80max
140max
150max
190max
85max
95max
20max
200max (DCIN 36V,
4.85 - 5.35
11.4 - 12.6
22.8 - 25.2
4.85 - 5.35
11.4 - 12.6
Works over 105% of rating and recovers automatically
Works at 115 - 140% of rating
Provided
Between RC and -side of input:short - 1.2V ---output ON, 2.4 - 5.5V(or open)---output OFF, Compatible TTL
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA max, DC500V 50MW min (At Room Temperature)
-10 to +85C (Aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-40 to +85C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN Complies with UL60950-1, CSA C22.2 No.60950-1 and EN60950-1
58X12.7X115mm (WXHXD) / 120g max
Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 Measured by attaching the electrolytic capacitor of 220mF at output.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
* Parallel operation with other model is not possible.
DAS-2
12
4.2
48max
100max
120max
160max
200max
230max
210max
230max
48max
Io=100%)
June 29, 2011
DAS50
External view
- V
- V
- S
NC
¶Recomending size for processing PCB
5.08 15.24 5.08
Name Plate
22.86
104.14
(4.1)
102.87
(4.05)
7.62
DC IN
3.5 ±0.5
Input/Output Pin
1.2
t = 0.5
2- º4.5
12- º1.7
5.08
5.08
(0.2) 15.24 (0.2)
5.08 (0.6) 5.08
(0.2)
(0.2)
5.08
5.08
(0.2)
(0.2)
RC
-
Outline
1.2
7.62
+ +
7.62 22.86 7.62
(0.3) (0.9) (0.3)
2-M4(Depth:6mm)
Mounting Hole for FG
0.5
2-M3(Depth:6mm)
Mounting Hole
for Heat Sink
(TOP VIEW)
104.14
102.87
104.14
115 ±1
58 ±0.5
12.7±0.5 3.5 ±0.5
3† 5.08
= 15.24
5.3 ±1
5.3 ±1
3† 5.08
= 15.24
5.3 ±1
Name Plate
TRM
+S
+V
+V
DC OUT
¶Weight: 120g or less.
¶Tolerance: ± 0.3
¶Case: PBT
¶Base Plate: Aluminum
¶Dimensions in mm.
¶Mounting torque
• Mounting Hole for Heat Sink:
0.4N·m( 5.0kgf·cm)max
• Mounting Hole for FG:
1.2N·m(12.8kgf·cm)max
mm
(inch)
¶Div.0.2inch
¶Unit :
Performance data
¡STATIC CHARACTERISTICS (DAS50F05)
¡RISE TIME & FALL TIME (DAS50F05)
¡OVERCURRENT CHARACTERISTICS (DAS50F05)
¡DERATING CURVE
OUTPUT VOLTAGE V
6.0
5.0
DAS
4.0
Input Voltage
3.0
88V
370V
2.0
1.0
0
5
10
15
OUTPUT CURRENT A
June 29, 2011
DAS-3
Ordering information
DC-DC Converters Power Module type
DAS100
DA
1
S
2
O
100
3
4
05
5
1Series name
2Single output
3Output wattage
4Input voltage
F :DC88 - 370V
48 :DC36 - 72V
5Output voltage
R
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
DAS100F05
100
5V 20A
DAS100F12
102
12V 8.5A
DAS100F24
100.8
24V 4.2A
DAS1004805
100
5V 20A
DAS1004812
102
12V 8.5A
SPECIFICATIONS
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
DAS
ENVIRONMENT
SAFETY
OTHERS
MODEL
VOLTAGE[V]
CURRENT[A]
EFFICIENCY[%]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +85C *1
RIPPLE[mVp-p]
-10 - 0C *1
0 to +85C *1
RIPPLE NOISE[mVp-p]
-10 - 0C *1
0 to +85C
TEMPERATURE REGULATION[mV]
-10 to +85C
*2
DRIFT[mV]
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CASE SIZE/WEIGHT
COOLING METHOD
DAS100F05
DAS100F12
DAS100F24
DC88 - 370
1.0typ (DCIN 130V, Io=100%) 0.5typ (DCIN 260V, Io=100%)
82typ
82typ
82typ
0.3max (By UL, CSA, VDE and DEN-AN)
5
12
24
20
8.5
4.2
20max
48max
96max
40max
100max
150max
80max
120max
120max
140max
160max
160max
150max
200max
200max
190max
230max
230max
85max
204max
408max
95max
228max
456max
20max
48max
96max
200max (DCIN 88V, Io=100%)
Fixed (TRM pin open)t10% adjustable by external VR
DAS1004805
DAS1004812
DC36 - 72
2.60typ (DCIN 48V, Io=100%) 2.59typ (DCIN 48V, Io=100%)
80typ
82typ
5
20
20max
40max
80max
140max
150max
190max
85max
95max
20max
200max (DCIN 36V,
4.85 - 5.35
11.4 - 12.6
22.8 - 25.2
4.85 - 5.35
11.4 - 12.6
Works over 105% of rating and recovers automatically
Works at 115 - 140% of rating
Provided
Between RC and -side of input:short - 1.2V ---output ON, 2.4 - 5.5V(or open)---output OFF, Compatible TTL
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA max, DC500V 50MW min (At Room Temperature)
-10 to +85C (Aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-40 to +85C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN Complies with UL60950-1, CSA C22.2 No.60950-1 and EN60950-1
58X12.7X130mm (WXHXD) / 150g max
Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 Measured by attaching the electrolytic capacitor of 220mF at output.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,with the input voltage held constant at the rated input/output.
* Parallel operation with other model is not possible.
DAS-4
12
8.5
48max
100max
120max
160max
200max
230max
210max
230max
48max
Io=100%)
June 29, 2011
DAS100
External view
- V
- V
- S
CB
7.62 22.86 7.62
(0.3) (0.9) (0.3)
118.11
119.38
5.3 ±1
5.08 15.24 5.08
(TOP VIEW)
119.38
(4.7)
118.11
(4.65)
12.7±0.5 3.5 ±0.5
119.38
130 ±1
58 ±0.5
¶Recomending size for processing PCB
3†5.08
=15.24
5.3 ±1
3†5.08
=15.24
5.3 ±1
Name Plate
TRM
+S
+V
+V
DC OUT
Outline
2-º4.5
2-M4(Depth:6mm)
Mounting Hole for FG
5.08
5.08
(0.2) 15.24 (0.2)
5.08 (0.6) 5.08
(0.2)
(0.2)
5.08
5.08
(0.2)
(0.2)
0.5
2-M3(Depth:6mm)
Mounting Hole
for Heat Sink
12-º1.7
1.2
Name Plate
22.86
-
+ +
7.62
RC
7.62
Input/Output Pin
3.5 ±0.5
DC IN
1.2
t = 0.5
¶Weight: 150g or less.
¶Tolerance: ± 0.3
¶Case: PBT
¶Base Plate: Aluminum
¶Dimensions in mm.
¶Mounting torque
• Mounting Hole for Heat Sink:
0.4N·m( 5.0kgf·cm)max
• Mounting Hole for FG:
1.2N·m(12.8kgf·cm)max
mm
(inch)
¶Div.0.2inch
¶Unit :
Performance data
¡STATIC CHARACTERISTICS (DAS100F05)
¡RISE TIME & FALL TIME (DAS100F05)
¡OVERCURRENT CHARACTERISTICS (DAS100F05)
¡DERATING CURVE
DAS
June 29, 2011
Powered by TCPDF (www.tcpdf.org)