0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PUA2412S1A

PUA2412S1A

  • 厂商:

    FLEX(伟创力)

  • 封装:

    SIP-4

  • 描述:

    隔离模块 直流转换器 1 输出 12V 84mA 21.6V - 26.4V 输入

  • 数据手册
  • 价格&库存
PUA2412S1A 数据手册
PUBLIC PRODUCT SPECIFICATION TABLE OF CONTENTS (Subject resp)responsible if other) Prepared (also subject 1/1301-BMR801 Technical Specification SEC/S Marshall Wang jidgezou George Zou Approved (Document resp) PUA-1AGeorge series Zou DC/DC Converters jidgezou 11 (4) (1) No. Checked Isolated 1W Unregulated Single Output Date Rev 2016-07-05 3/14/2023 Reference 28701-BMR801 Rev. F A D March 2023 © Flex Key Features • Industry standard SIP-4 package 11.6 x 6 x 10.2 mm (0.46 x 0.24 x 0.4 in) • High efficiency, typ. 84% at 15VO full load • 2000 Vdc input to output isolation • Wide operating temperature from -40°C to 100°C • No minimum load required • Output short-circuit protection • 3.3 V, 5 V, 12 V & 24 V input • 3.3 V, 5 V, 12 V & 15 V output • MTBF 13.1 Mh General Characteristics • 1 Watt output power • Safety Compliance to EN/UL 62368-1 • ISO 9001/14001 certified supplier Safety Approvals Meet Meet Design for Environment Meets requirements in hightemperature lead-free soldering processes. Contents Ordering Information General Information Safety Specification Absolute Maximum Ratings ............................................................. 2 ............................................................. 2 ............................................................. 3 ............................................................. 4 Electrical Specification 3.3-24 VI / 3.3-15 VO, 0.07-0.3 A / 1 W PUA-1A Series ..................................... 5 EMC Specification Operating Information Thermal Consideration Connections Mechanical Information Soldering Information Delivery Information Product Qualification Specification ........................................................... 11 ........................................................... 12 ........................................................... 13 ........................................................... 13 ........................................................... 14 ........................................................... 15 ........................................................... 15 ........................................................... 16 PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) 2 (4) No. 1/1301-BMR801 Technical Specification jidgezou George Zou Approved (Document resp) PUA-1AGeorge series Zou DC/DC Converters jidgezou Checked Date 3/14/2023 Isolated 1W Unregulated Single Output Rev 28701-BMR801 Rev. F D March 2023 © Flex Compatibility with RoHS requirements Ordering Information Product PUA0303S1A PUA0305S1A PUA0312S1A PUA0503S1A PUA0505S1A PUA0512S1A PUA1203S1A PUA1205S1A PUA1212S1A PUA2403S1A PUA2405S1A PUA2412S1A PUA2415S1A 2 Nominal Input 3.3 V 3.3 V 3.3 V 5V 5V 5V 12 V 12 V 12 V 24 V 24 V 24 V 24 V The products are compatible with the relevant clauses and requirements of the RoHS directive 2011/65/EU and have a maximum concentration value of 0.1% by weight in homogeneous materials for lead, mercury, hexavalent chromium, PBB and PBDE and of 0.01% by weight in homogeneous materials for cadmium. Output 3.3 V, 0.303 A / 1 W 5 V, 0.2 A / 1 W 12 V, 0.084 A / 1 W 3.3 V, 0.303 A / 1 W 5.0 V, 0.2 A / 1 W 12 V, 0.084 A / 1 W 3.3 V, 0.303 A / 1 W 5.0 V, 0.2 A / 1 W 12 V, 0.084 A / 1 W 3.3 V, 0.303 A / 1 W 5.0 V, 0.2 A / 1 W 12 V, 0.084 A / 1 W 15 V, 0.067 A / 1 W Product number and Packaging PUAX1X2X3X4n1n2n3* Options n1 Single output ο Exemptions in the RoHS directive utilized in Flex products are found in the Statement of Compliance document. Flex fulfills and will continuously fulfill all its obligations under regulation (EC) No 1907/2006 concerning the registration, evaluation, authorization and restriction of chemicals (REACH) as they enter into force and is through product materials declarations preparing for the obligations to communicate information on substances in the products. Quality Statement Options Description n1 S Single Output The products are designed and manufactured in an industrial environment where quality systems and methods like ISO 9000, Six Sigma, and SPC are intensively in use to boost the continuous improvements strategy. Infant mortality or early failures in the products are screened out and they are subjected to an ATE-based final test. Conservative design rules, design reviews and product qualifications, plus the high competence of an engaged work force, contribute to the high quality of the products. n2 1 1W Warranty n3 A SIP4 Warranty period and conditions are defined in Flex General Terms and Conditions of Sale. n2 n3 ο Output Power ο Form factor Example: a 24Vdc nominal input, single 5Vdc output, 1W SIP4 product would be PUA2405S1A. * X1X2 = Nominal input voltage X3X4 = Output voltage Limitation of Liability Flex does not make any other warranties, expressed or implied including any warranty of merchantability or fitness for a particular purpose (including, but not limited to, use in life support applications, where malfunctions of product can cause injury to a person’s health or life). General Information © Flex 2023 Reliability The information and specifications in this technical specification is believed to be correct at the time of publication. However, no liability is accepted for inaccuracies, printing errors or for any consequences thereof. Flex reserves the right to change the contents of this technical specification at any time without prior notice. The failure rate (λ) and mean time between failures (MTBF= 1/λ) is calculated at max output power and an operating ambient temperature (TA) of +25°C. Flex uses MIL-HDBK-217F, Notice 2 to calculate the mean steadystate failure rate. In MIL-HDBK-217F, all part reliability models include the effects of environmental stresses through the environmental factor, πE. It encompasses the major areas of equipment use, here we use ground benign, GB. Mean steady-state failure rate, λ MTBF 76.3 nFailures/h 13.1 Mh PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) PUA-1AGeorge series Zou DC/DC Converters jidgezou 1/1301-BMR801 Technical Specification Checked Isolated 1W Unregulated Single Output Safety Specification General information Flex Power DC/DC converters and DC/DC regulators are designed in accordance with the safety standards IEC 62368-1, EN 62368-1 and UL 62368-1 Audio/video, information and communication technology equipment Part 1: Safety requirements IEC/EN/UL 62368-1 contains requirements to prevent injury or damage due to the following hazards: • • • • • • 3 (4) No. jidgezou George Zou Approved (Document resp) 3 Electrical shock Electrically-caused fire Injury caused by hazardous substances Mechanically-caused injury Skin burn Radiation-caused injury On-board DC/DC converters, Power interface modules and DC/DC regulators are defined as component power supplies. As components they cannot fully comply with the provisions of any safety requirements without “conditions of acceptability”. Clearance between conductors and between conductive parts of the component power supply and conductors on the board in the final product must meet the applicable safety requirements. Certain conditions of acceptability apply for component power supplies with limited stand-off (see Mechanical Information for further information). It is the responsibility of the installer to ensure that the final product housing these components complies with the requirements of all applicable safety standards and regulations for the final product. Component power supplies for general use shall comply with the requirements in IEC/EN/UL 62368-1. Product related standards, e.g. IEEE 802.3af Power over Ethernet, and ETS-300132-2 Power interface at the input to telecom equipment, operated by direct current (dc) are based on IEC/EN/UL 62368-1 with regards to safety. Flex Power DC/DC converters, Power interface modules and DC/DC regulators are UL 62368-1 recognized and certified in accordance with EN 62368-1. The flammability rating for all construction parts of the products meet requirements for V-0 class material according to IEC 60695-11-10, Fire hazard testing, test flames – 50 W horizontal and vertical flame test methods. Isolated DC/DC converters & Power interface modules The product may provide basic or functional insulation between input and output according to IEC/EN/UL 62368-1 (see Safety Certificate), different conditions shall be met if the output of a basic or a functional insulated product shall be considered as ES1 energy source. For basic insulated products (see Safety Certificate) the output is considered as ES1 energy source if one of the Date 3/14/2023 Rev 28701-BMR801 Rev. F D March 2023 © Flex following conditions is met: • The input source provides supplementary or double or reinforced insulation from the AC mains according to IEC/EN/UL 62368-1. • The input source provides functional or basic insulation from the AC mains and the product’s output is reliably connected to protective earth according to IEC/EN/UL 62368-1. For functional insulated products (see Safety Certificate) the output is considered as ES1 energy source if one of the following conditions is met: • The input source provides double or reinforced insulation from the AC mains according to IEC/EN/UL 62368-1. • The input source provides basic or supplementary insulation from the AC mains and the product’s output is reliably connected to protective earth according to IEC/EN/UL 62368-1. • The input source is reliably connected to protective earth and provides basic or supplementary insulation according to IEC/EN/UL 62368-1 and the maximum input source voltage is 60 Vdc. Galvanic isolation between input and output is verified in an electric strength test and the isolation voltage (Viso) meets the voltage strength requirement for basic insulation according to IEC/EN/UL 62368-1. It is recommended to use a slow blow fuse at the input of each DC/DC converter. If an input filter is used in the circuit the fuse should be placed in front of the input filter. In the rare event of a component problem that imposes a short circuit on the input source, this fuse will provide the following functions: • Isolate the fault from the input power source so as not to affect the operation of other parts of the system • Protect the distribution wiring from excessive current and power loss thus preventing hazardous overheating Non - isolated DC/DC regulators The DC/DC regulator output is ES1 energy source if the input source meets the requirements for ES1 according to IEC/EN/UL 62368-1. 4 PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) 2/1301-BMR801 Technical Specification jidgezou George Zou Approved (Document resp) PUA-1AGeorge series Zou DC/DC Converters jidgezou 1 (8) No. Checked Isolated 1W Unregulated Single Output Date 3/14/2023 Rev March 2023 28701-BMR801 Rev. F D © Flex Absolute Maximum Ratings Characteristics min TP1 Operating Temperature (see Thermal Consideration section) -40 TCASE Max. case temperature TS Storage temperature -55 VI Input voltage Range (base on nominal input voltage) -10 Viso Isolation voltage (input to output test voltage in 1minute) typ max Unit +100 °C +110 °C +125 °C +10 % 2000 Vdc Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the Electrical Specification section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Fundamental Circuit Diagram 5 PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) 2 (8) No. 2/1301-BMR801 Technical Specification jidgezou George Zou Approved (Document resp) PUA-1AGeorge series Zou DC/DC Converters jidgezou Checked Isolated 1W Unregulated Single Output Date Rev March 2023 28701-BMR801 Rev. F D 3/14/2023 © Flex Electrical Specification Typical values given at: TP1 = +25°C, unless otherwise specified under Conditions. Part Number Input Voltage (±10%) V Output Voltage V Output Current mA Efficiency (typ.) half of max IO % Efficiency (typ.) max IO % Capacitive Load note 1 µF 3.3 3.3 303 71 75 1500 76 1500 PUA0303S1A PUA0305S1A 3.3 5 200 72 PUA0312S1A 3.3 12 84 70 77 470 PUA0503S1A 5 3.3 303 70 74 1500 PUA0505S1A 5 5 200 71 78 1500 PUA0512S1A 5 12 84 70 78 470 PUA1203S1A 12 3.3 303 72 79 1500 PUA1205S1A 12 5 200 74 82 1500 PUA1212S1A 12 12 84 70 80 470 PUA2403S1A 24 3.3 303 71 78 1500 PUA2405S1A 24 5 200 70 79 1500 80 470 84 220 PUA2412S1A 24 12 84 71 PUA2415S1A 24 15 67 72 Characteristics CI Internal input capacitance PO Output power CISO Isolation capacitance RISO Isolation resistance Conditions min typ max 1 µF 1 20 GΩ 10 TP1 = +25°C, IO = max IO -5 Minimum load TP1 = +25°C 0 Line regulation VLL to VHL, max IO 1.2 1.3 Load regulation ILL - IHL, at typ. Vin VO = 3.3 / 5 V 10 15 VO = 12 - 15 V 7.5 10 fs Switching frequency 100 % of max IO (at Nominal Vin) VOac Output ripple & noise 20MHz bandwidth limit, see Note 2 Note 1: The maximum capacitive load is test by normal input and constant resistive load. Note 2: The Output ripple & noise is under nominal Vin and max IO with 0.1 µF/50 V MLCC W pF Voltage accuracy VOi Unit +5 % % 50 % % kHz 100 mVp-p 6 PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) 3 (8) No. 2/1301-BMR801 Technical Specification jidgezou George Zou Approved (Document resp) PUA-1AGeorge series Zou DC/DC Converters jidgezou Checked Isolated 1W Unregulated Single Output Date Rev March 2023 28701-BMR801 Rev. F D 3/14/2023 © Flex Typical Characteristics PUA-1A series 100% 100% 80% 80% 60% 60% PUA0303S1A 40% PUA0305S1A 20% Efficiency Efficiency Efficiency Efficiency 0 10 20 30 40 50 60 Load (%) 70 80 PUA0505S1A 20% PUA0312S1A 0% PUA0503S1A 40% 0% 90 100 PUA0512S1A 0 PUA03-1A Efficiency vs. load current at TP1 = +25°C. 100% 80% 80% 60% PUA1203S1A PUA1205S1A 0% PUA1212S1A Efficiency 100% Efficiency Efficiency 20% 10 20 30 40 50 60 Load (%) 70 80 30 40 50 60 Load (%) 70 80 90 100 60% PUA2403S1A 40% PUA2405S1A PUA2412S1A 20% 0% 0 20 PUA05-1A Efficiency vs. load current at TP1 = +25°C. Efficiency 40% 10 90 100 PUA12-1A Efficiency vs. load current at TP1 = +25°C. PUA2415S1A 0 10 20 30 40 50 60 Load (%) 70 80 90 100 PUA24-1A Efficiency vs. load current at TP1 = +25°C. Operating Ambient Temperature Curve Load (%) Load (%) 100 100 80 80 60 60 40 40 20 Nat. Conv. 0 20 Nat. Conv. 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 [°C] PUA03-1A, PUA05-1A, PUA12-1A Available load vs. ambient air temperature. See Thermal Consideration section. -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 [°C] PUA24-1A Available load vs. ambient air temperature. See Thermal Consideration section. 7 PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) 4 (8) No. 2/1301-BMR801 Technical Specification jidgezou George Zou Approved (Document resp) PUA-1AGeorge series Zou DC/DC Converters jidgezou Checked Date Rev Isolated 1W Unregulated Single Output March 2023 28701-BMR801 Rev. F D 3/14/2023 © Flex Typical Characteristics PUA-1A series Output Voltage Accuracy Output Voltage Accuracy 30% 30% 2.97Vin 3.3Vin 20% 4.5Vin 5Vin 20% 5.5Vin Accuracy Accuracy 3.63Vin 10% 0% -10% 10% 0% -10% -20% 0 10 20 30 40 50 60 70 80 90 -20% 100 0 10 20 30 40 Load (%) PUA03-1A Output voltage accuracy vs. load current at TP1 = +25°C. 60 70 80 100 Output Voltage Accuracy 30% 30% 10.8Vin 12Vin 21.6Vin 24Vin 20% 13.2Vin 10% 0% -10% Accuracy 20% 26.4Vin 10% 0% -10% -20% -20% 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 Load (%) 40 50 60 70 80 90 100 Load (%) PUA12-1A Output voltage accuracy vs. load current at TP1 = +25°C. PUA24-1A Output voltage accuracy vs. load current at TP1 = +25°C. Load Regulation Load Regulation 20% 20% 2.97Vin 4.5Vin 3.3Vin 5Vin 15% 3.63Vin 10% 5% Regulation 15% Regulation 90 PUA05-1A Output voltage accuracy vs. load current at TP1 = +25°C. Output Voltage Accuracy Accuracy 50 Load (%) 5.5Vin 10% 5% 0% 0% 0 10 20 30 40 50 60 70 80 90 100 Load (%) 0 10 20 30 40 50 60 70 80 90 100 Load (%) PUA03-1A PUA05-1A Output voltage with load variation vs. load current at TP1 = +25°C Output voltage with load variation vs. load current at TP1 = +25°C 8 PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) 5 (8) No. 2/1301-BMR801 Technical Specification jidgezou George Zou Approved (Document resp) PUA-1AGeorge series Zou DC/DC Converters jidgezou Checked Date Rev Isolated 1W Unregulated Single Output March 2023 28701-BMR801 Rev. F D 3/14/2023 © Flex Typical Characteristics PUA-1A series Load Regulation Load Regulation 20% 20% 10.8Vin 12Vin 24Vin 15% 13.2Vin 10% 5% Regulation 15% Regulation 21.6Vin 26.4Vin 10% 5% 0% 0 10 20 30 40 50 60 70 80 90 100 Load (%) 0% 0 10 20 30 40 50 60 Load (%) 70 80 90 100 PUA12-1A PUA24-1A Output voltage with load variation vs. load current at TP1 = +25°C Output voltage with load variation vs. load current at TP1 = +25°C Output Ripple & Noise Output voltage ripple at: TP1 = +25°C, VI = 3.3 V, VO = 5 V IO = 200 mA resistive load. Output Ripple & Noise Trace: output voltage (50 mV/div.). Time scale: (10 µs/div.). 20 MHz bandwidth filter +0.1 µF Output Ripple & Noise Output voltage ripple at: TP1 = +25°C, VI = 12 V, VO = 5 V IO = 200 mA resistive load. Output voltage ripple at: TP1 = +25°C, VI = 5 V, VO = 5 V IO = 200 mA resistive load. Trace: output voltage (50 mV/div.). Time scale: (10 µs/div.). 20 MHz bandwidth filter +0.1 µF Output Ripple & Noise Trace: output voltage (50 mV/div.). Time scale: (10 µs/div.). 20 MHz bandwidth filter +0.1 µF Output voltage ripple at: TP1 = +25°C, VI = 24 V, VO = 5 V IO = 200 mA resistive load. Trace: output voltage (50 mV/div.). Time scale: (10 µs/div.). 20 MHz bandwidth filter +0.1 µF 9 PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) 2/1301-BMR801 Technical Specification jidgezou George Zou Approved (Document resp) PUA-1AGeorge series Zou DC/DC Converters jidgezou Checked Isolated 1W Unregulated Single Output Date 3/14/2023 Rev 28701-BMR801 Rev. F D PUA-1A series Start-up Shut-down Top trace: Input voltage (2 V/div.). Bottom trace: + Output voltage (2 V/div.). Time scale: (1 ms/div.). Start-up Start-up, enabled by connecting VI at: TP1 = +25°C, VI = 5 V, VO = 5 V IO = 200 mA resistive load. Shut-down, closed by disconnecting VI at: TP1 = +25°C, VI = 3.3 V, VO = 5 V IO = 200 mA resistive load. Top trace: Input voltage (2 V/div.). Bottom trace: + Output voltage (2 V/div.). Time scale: (2 ms/div.). Shut-down Top trace: Input voltage (2 V/div.). Bottom trace: + Output voltage (2 V/div.). Time scale: (1 ms/div.). Start-up Start-up, enabled by connecting VI at: TP1 = +25°C, VI = 12 V, VO = 5 V IO = 200 mA resistive load. March 2023 © Flex Typical Characteristics Start-up, enabled by connecting VI at: TP1 = +25°C, VI = 3.3 V, VO = 5 V IO = 200 mA resistive load. 6 (8) No. Shut-down, closed by disconnecting VI at: TP1 = +25°C, VI = 5 V, VO = 5 V IO = 200 mA resistive load. Top trace: Input voltage (2 V/div.). Bottom trace: + Output voltage (2 V/div.). Time scale: (2 ms/div.). Shut-down Top trace: Input voltage (5 V/div.). Bottom trace: + Output voltage (2 V/div.). Time scale: (1 ms/div.). Shut-down, closed by disconnecting VI at: TP1 = +25°C, VI = 12 V, VO = 5 V IO = 200 mA resistive load. Top trace: Input voltage (5 V/div.). Bottom trace: + Output voltage (2 V/div.). Time scale: (2 ms/div.). 10 PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) 2/1301-BMR801 Technical Specification jidgezou George Zou Approved (Document resp) PUA-1AGeorge series Zou DC/DC Converters jidgezou Checked Isolated 1W Unregulated Single Output Date 3/14/2023 Rev 28701-BMR801 Rev. F D March 2023 © Flex Typical Characteristics PUA-1A series Start-up Start-up, enabled by connecting VI at: TP1 = +25°C, VI = 24 V, VO = 5 V IO = 200 mA resistive load. 7 (8) No. Shut-down Top trace: Input voltage (10 V/div.). Bottom trace: + Output voltage (2 V/div.). Time scale: (1 ms/div.). Shut-down, closed by disconnecting VI at: TP1 = +25°C, VI = 24 V, VO = 5 V IO = 200 mA resistive load. Top trace: Input voltage (10 V/div.). Bottom trace: + Output voltage (2 V/div.). Time scale: (2 ms/div.). PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) 11 1 (4) No. 3/1301-BMR801 Technical Specification jidgezou George Zou Approved (Document resp) PUA-1AGeorge series Zou DC/DC Converters jidgezou Checked Isolated 1W Unregulated Single Output Date 3/27/2020 Rev 28701-BMR801 Rev. F C March 2023 © Flex EMC Specification Conducted EMI measured according to EN55032, CISPR 32 and FCC part 15J (see test set-up). See Design Note 029 for further information. The minimum switching frequency is 50 kHz. The EMI characteristics below is measured at max IO. Optional external filter for class B Suggested external input filter in order to meet class B in EN 55032, CISPR 32 and FCC part 15J. Test set-up Layout recommendations The radiated EMI performance of the product will depend on the PWB layout and ground layer design. It is also important to consider the stand-off of the product. If a ground layer is used, it should be connected to the output of the product and to the equipment ground or chassis. A ground layer will increase the stray capacitance in the PWB and improve the high frequency EMC performance. EMI external circuit Series L1 C1 PUA03-1A 47μH 4.7μF PUA05-1A 47μH 10μF PUA12-1A 22μH 4.7μF PUA24-1A 47μH 4.7μF Output ripple and noise Output ripple and noise is measured according to figure below. See Design Note 022 for detailed information. Based on different applications or PCB layout conditions, the EMI requirement may be varied. Recommend to reserve Cy1 for better EMI performance. Depending on the different requirement of end users, the value of Cy1 could be adjusted from 33pF to 470pF. Output ripple and noise test setup PUA0505S1A EMI with filter PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) PUA-1AGeorge series Zou DC/DC Converters jidgezou 2 (4) No. 3/1301-BMR801 Technical Specification jidgezou George Zou Approved (Document resp) 12 Checked Isolated 1W Unregulated Single Output Operating Information Input Voltage Converter with 10% input voltage range, mainly for isolated power in industrial applications. For example, the input voltage range 4.5 to 5.5 Vdc meets requirement of general industrial used for 5Vdc system. The input voltage should never exceed the absolute voltage of the converter, and must be limited to absolute max +100°C. The output voltage related to input voltage. Take 5Vin and 5Vo product as an example, if input voltage above 5V, the output voltage will higher than 5V. Below 5V and the output voltage starts to track the input voltage. Short duration transient disturbances can occur on the DC distribution and input of the product when a short circuit fault occurs on the equipment side of a protective device (fuse or circuit breaker). The voltage level, duration and energy of the disturbance are dependent on the particular DC distribution network characteristics and can be sufficient to damage the product unless measures are taken to suppress or absorb this energy. The transient voltage can be limited by capacitors and other energy absorbing devices like Zener diodes connected across the positive and negative input conductors at a number of strategic points in the distribution network. The end-user must secure that the transient voltage will not exceed the value stated in the Absolute maximum ratings. ETSI TR 100 283 examines the parameters of DC distribution networks and provides guidelines for controlling the transient and reduce its harmful effect. Turn-off Input Voltage The products do not have under voltage lock-out function. Please make sure the input voltage of each module is correct working range. Input and Output Impedance The impedance of both the input source and the load will interact with the impedance of the product. It is important that the input source has low characteristic impedance.The product are designed for stable operation without external capacitors. With a 10μF capacitors connected to the input could reduce the input noise cause by parasitic inductance. External Decoupling Capacitors When powering loads with significant dynamic current requirements, the voltage regulation at the load can be improved by addition of decoupling capacitors at the load. The most effective technique is to locate low ESR ceramic and electrolytic capacitors as close to the load as possible, using several parallel capacitors to lower the effective ESR. The ceramic capacitors will handle high-frequency dynamic load changes while the electrolytic capacitors are used to handle Date 3/27/2020 Rev 28701-BMR801 Rev. F C March 2023 © Flex low frequency dynamic load changes. It is equally important to use low resistance and low inductance PWB layouts and cabling. External decoupling capacitors will become part of the product’s control loop. The control loop is optimized for a wide range of external capacitance and the maximum and minimum recommended value that could be used without any additional analysis is found in the Electrical specification. The ESR of the capacitors is a very important parameter. Stable operation is guaranteed with a verified ESR value of >1 mΩ across the output connections. For further information please contact your local Flex Power Modules representative. Parallel Operation This product is not designed for paralleling without using external current sharing circuits. Over Current Protection (OCP) The products include current limiting circuitry for protection at continuous overload. The OCP works in a hiccup mode and will make continous attempts to start up and will resume normal operation automatically after removal of the over current condition. The load distribution should be designed for the specified maximum output short circuit current. PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) 3/1301-BMR801 Technical Specification PUA-1AGeorge series Zou DC/DC Converters jidgezou Checked Isolated 1W Unregulated Single Output Thermal Consideration Date Definition of product operating temperature The temperature at the positions P1 (TP1) should not exceed the maximum temperatures in the table below. The number of measurement points may vary with different thermal design and topology. Temperatures above maximum measured at the reference point P1 are not allowed and may cause permanent damage. Position Description Max Temp. Pin side (baseplate module) © Flex Bottom View PUAxxxxS1A series \ Case Rev 28701-BMR801 Rev. F C 3/27/2020 Connections General The products are designed to operate in different thermal environments and sufficient cooling must be provided to ensure reliable operation. For products mounted on a PWB without a baseplate attached, cooling is achieved mainly by conduction, from the pins to the host board, and convection, which is dependant on the airflow across the product. Increased airflow enhances the cooling of the product. The Output Current Derating graph found in the Output section for each model provides the available output current vs. ambient air temperature and air velocity. The product is tested on a 95 x 85 mm, 35 µm (1 oz), 2layer test board mounted horizontally in a space with a volume of 300(L) x 300(W) x 200(H) mm. P1 3 (4) No. jidgezou George Zou Approved (Document resp) 13 TP1=110º C Pin 1 Designation -Vin Function Negative Input 2 +Vin Positive Input 3 -Out Negative Output 4 +Out Positive Output March 2023 PUBLIC PRODUCT SPEC. MECHANICAL Prepared (Subject resp) No. PUA-1A series DC/DC Converters Isolated 1W Unregulated Single Output Approved (Document resp) Checked Date 14 1 (2) Technical Specification Rev 28701-BMR801 Rev. F March 2023 © Flex Mechanical Information – Through Hole Mounting Recommended Footprint All component placements – whether shown as physical components or symbolical outline – are for reference only and are subject to change throughout the product’s life cycle, unless explicitly described and dimensioned in this drawing. PUBLIC PRODUCT SPEC. Prepared (Subject resp) 15 1 (3) No. 5/1301 - BMR801 Technical Specification jidgezou George Zou Approved (Document resp) PUA-1AGeorge series Zou DC/DC Converters jidgezou Checked Isolated 1W Unregulated Single Output Soldering Information - Hole Mounting The hole mounted product is intended for plated through hole mounting by wave or manual soldering. The pin temperature is specified to maximum to 260°C for maximum 5 seconds. A maximum preheat rate of 4°C/s and maximum preheat temperature of 150°C is suggested. When soldering by hand, care should be taken to avoid direct contact between the hot soldering iron tip and the pins for more than a few seconds in order to prevent overheating. A no-clean flux is recommended to avoid entrapment of cleaning fluids in cavities inside the product or between the product and the host board. The cleaning residues may affect long time reliability and isolation voltage. Delivery Package Information The products are delivered in antistatic tube. Tube Specifications – SIP Material Antistatic PS Surface resistance 105 < Ohm/square < 1012 Tube length 520 mm 20.47 [ inch] Tube capacity 41 products (36 full tubes/box) Tube weight 20.4 g empty, 85 g full tube Module weight 1.4 g / pc 1BOX = 41 (pcs/tube) * 12 (tube/bundle) * 3 (bundle) = 1476 pcs 1BOX = 1476 converters All dimensions in mm Note: pick up positions refer to center of pocket. See mechanical drawing for exact location on product. Date 3/14/2023 Rev 28701-BMR801 Rev. F C © Flex March 2023 16 PUBLIC PRODUCT SPEC. Prepared (Subject resp) 2 (3) No. 5/1301 - BMR801 Technical Specification jidgezou George Zou Approved (Document resp) PUA-1AGeorge series Zou DC/DC Converters jidgezou Checked Isolated 1W Unregulated Single Output Date 3/14/2023 Rev 28701-BMR801 Rev. F C © Flex Product Qualification Specification Characteristics External visual inspection IPC-A-610 Change of temperature (Temperature cycling) MI-STD-202G, method 107G Temperature range Number of cycles Dwell/transfer time -55 to 125°C 1000 30 min/0-1 min Cold (in operation) IEC 60068-2-1 Ad Temperature TA Duration -45°C 72 h Damp heat MIL-STD-202G, Method 103B Temperature Humidity Duration 85°C 95 % RH 1000 hours Dry heat IEC 60068-2-2 Bd Temperature Duration 125°C 1000 h Electrostatic discharge susceptibility IEC 61000-4-2 Air model Contact model 8000 V 6000 V Mechanical shock MIL-STD-202G, method 213B Peak acceleration Duration 100 g 6 ms Operational life test MIL-STD-202G, method 108A Duration 1000 h Resistance to soldering heat 1 MIL-STD-202G, method 210F Solder temperature Duration 260°C 10 s Robustness of terminations IEC 60068-2-21 Test Ua1 IEC 60068-2-21 Test Ue1 Through hole mount products Surface mount products All leads All leads Solderability J-STD-002 Preconditioning Temperature, Pb-free Steam ageing 8 h 245°C Vibration MIL-STD-202G, method 201A Frequency Displacement Duration 10 to 55 Hz 0.06 inch 2 h in each direction Notes 1 Only for products intended for wave soldering (plated through hole products) March 2023
PUA2412S1A 价格&库存

很抱歉,暂时无法提供与“PUA2412S1A”相匹配的价格&库存,您可以联系我们找货

免费人工找货