0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PUB1205S1M

PUB1205S1M

  • 厂商:

    FLEX(伟创力)

  • 封装:

    SMD5 模块

  • 描述:

    隔离模块 直流转换器 1 输出 5V 200mA 10.8V - 13.2V 输入

  • 数据手册
  • 价格&库存
PUB1205S1M 数据手册
PUBLIC PRODUCT SPECIFICATION TABLE OF CONTENTS Prepared (also (Subject resp)responsible if other) Prepared subject No. No. SEC/S Marshall Wang jidgezou George Zou Approved Approved (Document resp) PUB-1MGeorge seriesZou DC/DC Converters jidgezou 11 (4) (1) 1/1301-BMR802 Technical Specification Checked Checked Isolated 1W Unregulated Single Output Date Date 2016-07-05 3/17/2023 Rev Rev Reference 28701-BMR802 A E Z Rev. E March 2023 © Flex Key Features • Industry standard SMD package 12.75 x 11.2 x 6.6 mm (0.5 x 0.441 x 0.26 in) for Single output 15.25 x 11.2 x 6.6 mm (0.6 x 0.441 x 0.26 in) for Dual output • High efficiency, typ. 81% at 5Vout full load • 3000 Vdc input to output isolation • Wide operating temperature from -40°C to 110°C • No minimum load required • Output short-circuit protection • 5 V, 12 V & 24 V input • 5 V output • MTBF 17.9 Mh General Characteristics • 1W output power • Safety Compliance to EN/UL 62368-1 • ISO 9001/14001 certified supplier Safety Approvals Meet Meet Design for Environment Meets requirements in hightemperature lead-free soldering processes. Contents Ordering Information General Information Safety Specification Absolute Maximum Ratings ............................................................. 2 ............................................................. 2 ............................................................. 3 ............................................................. 4 Electrical Specification 5-24 VI / 5 VO, 0.2 A / 1 W PUB-1M Series ..................................... 5 EMC Specification Operating Information Thermal Consideration Connections Mechanical Information Soldering Information Delivery Information Product Qualification Specification ........................................................... 10 ........................................................... 11 ........................................................... 12 ........................................................... 12 ........................................................... 13 ........................................................... 14 ........................................................... 14 ........................................................... 15 PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) No. jidgezou George Zou 2 (4) 1/1301-BMR802 Technical Specification Approved (Document resp) PUB-1MGeorge seriesZou DC/DC Converters jidgezou Checked Date 3/17/2023 Isolated 1W Unregulated Single Output Ordering Information Product PUB0505S1M PUB1205S1M PUB2405S1M 2 Nominal Input 5V 12 V 24 V n2 March 2023 © Flex Exemptions in the RoHS directive utilized in Flex products are found in the Statement of Compliance document. Output 5.0 V, 0.2 A / 1 W 5.0 V, 0.2 A / 1 W 5.0 V, 0.2 A / 1 W Product number and Packaging PUBX1X2X3X4n1n2n3* Options n1 Single/Dual output ο Rev 28701-BMR802 E Z Rev. E n3 Flex fulfills and will continuously fulfill all its obligations under regulation (EC) No 1907/2006 concerning the registration, evaluation, authorization and restriction of chemicals (REACH) as they enter into force and is through product materials declarations preparing for the obligations to communicate information on substances in the products. Quality Statement Options Description n1 S D Single Output Dual Output n2 1 1W The products are designed and manufactured in an industrial environment where quality systems and methods like ISO 9000, Six Sigma, and SPC are intensively in use to boost the continuous improvements strategy. Infant mortality or early failures in the products are screened out and they are subjected to an ATE-based final test. Conservative design rules, design reviews and product qualifications, plus the high competence of an engaged work force, contribute to the high quality of the products. n3 M SMD Warranty ο Output Power Form factor ο Example: a 24Vdc nominal input, single 5Vdc output, 1W SMD product would be PUB2405S1M. Warranty period and conditions are defined in Flex General Terms and Conditions of Sale. The products are delivered in tape and reel. See details in Delivery Package Information. Limitation of Liability * X1X2 = Nominal input voltage X3X4 = Output voltage General Information Flex does not make any other warranties, expressed or implied including any warranty of merchantability or fitness for a particular purpose (including, but not limited to, use in life support applications, where malfunctions of product can cause injury to a person’s health or life). Reliability © Flex 2023 The failure rate (λ) and mean time between failures (MTBF= 1/λ) is calculated at max output power and an operating ambient temperature (TA) of +25°C. Flex uses MIL-HDBK-217F, Notice 2 to calculate the mean steadystate failure rate. The information and specifications in this technical specification is believed to be correct at the time of publication. However, no liability is accepted for inaccuracies, printing errors or for any consequences thereof. Flex reserves the right to change the contents of this technical specification at any time without prior notice. In MIL-HDBK-217F, all part reliability models include the effects of environmental stresses through the environmental factor, πE. It encompasses the major areas of equipment use, here we use ground benign, GB. MTBF Mean steady-state failure rate, λ 55.6 nFailures/h 17.9 Mh Compatibility with RoHS requirements The products are compatible with the relevant clauses and requirements of the RoHS directive 2011/65/EU and have a maximum concentration value of 0.1% by weight in homogeneous materials for lead, mercury, hexavalent chromium, PBB and PBDE and of 0.01% by weight in homogeneous materials for cadmium. PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) No. jidgezou George Zou Approved (Document resp) PUB-1MGeorge seriesZou DC/DC Converters jidgezou 3 (4) 1/1301-BMR802 Technical Specification Checked Isolated 1W Unregulated Single Output Safety Specification General information Flex Power DC/DC converters and DC/DC regulators are designed in accordance with the safety standards IEC 62368-1, EN 62368-1 and UL 62368-1 Audio/video, information and communication technology equipment Part 1: Safety requirements IEC/EN/UL 62368-1 contains requirements to prevent injury or damage due to the following hazards: • • • • • • 3 Electrical shock Electrically-caused fire Injury caused by hazardous substances Mechanically-caused injury Skin burn Radiation-caused injury On-board DC/DC converters, Power interface modules and DC/DC regulators are defined as component power supplies. As components they cannot fully comply with the provisions of any safety requirements without “conditions of acceptability”. Clearance between conductors and between conductive parts of the component power supply and conductors on the board in the final product must meet the applicable safety requirements. Certain conditions of acceptability apply for component power supplies with limited stand-off (see Mechanical Information for further information). It is the responsibility of the installer to ensure that the final product housing these components complies with the requirements of all applicable safety standards and regulations for the final product. Component power supplies for general use shall comply with the requirements in IEC/EN/UL 62368-1. Product related standards, e.g. IEEE 802.3af Power over Ethernet, and ETS-300132-2 Power interface at the input to telecom equipment, operated by direct current (dc) are based on IEC/EN/UL 62368-1 with regards to safety. Flex Power DC/DC converters, Power interface modules and DC/DC regulators are UL 62368-1 recognized and certified in accordance with EN 62368-1. The flammability rating for all construction parts of the products meet requirements for V-0 class material according to IEC 60695-11-10, Fire hazard testing, test flames – 50 W horizontal and vertical flame test methods. Isolated DC/DC converters & Power interface modules The product may provide basic or functional insulation between input and output according to IEC/EN/UL 62368-1 (see Safety Certificate), different conditions shall be met if the output of a basic or a functional insulated product shall be considered as ES1 energy source. For basic insulated products (see Safety Certificate) the output is considered as ES1 energy source if one of the Date 3/17/2023 Rev 28701-BMR802 E Z Rev. E March 2023 © Flex following conditions is met: • The input source provides supplementary or double or reinforced insulation from the AC mains according to IEC/EN/UL 62368-1. • The input source provides functional or basic insulation from the AC mains and the product’s output is reliably connected to protective earth according to IEC/EN/UL 62368-1. For functional insulated products (see Safety Certificate) the output is considered as ES1 energy source if one of the following conditions is met: • The input source provides double or reinforced insulation from the AC mains according to IEC/EN/UL 62368-1. • The input source provides basic or supplementary insulation from the AC mains and the product’s output is reliably connected to protective earth according to IEC/EN/UL 62368-1. • The input source is reliably connected to protective earth and provides basic or supplementary insulation according to IEC/EN/UL 62368-1 and the maximum input source voltage is 60 Vdc. Galvanic isolation between input and output is verified in an electric strength test and the isolation voltage (Viso) meets the voltage strength requirement for basic insulation according to IEC/EN/UL 62368-1. It is recommended to use a slow blow fuse at the input of each DC/DC converter. If an input filter is used in the circuit the fuse should be placed in front of the input filter. In the rare event of a component problem that imposes a short circuit on the input source, this fuse will provide the following functions: • Isolate the fault from the input power source so as not to affect the operation of other parts of the system • Protect the distribution wiring from excessive current and power loss thus preventing hazardous overheating Non - isolated DC/DC regulators The DC/DC regulator output is ES1 energy source if the input source meets the requirements for ES1 according to IEC/EN/UL 62368-1. Prepared (Subject resp) 1 (7) No. jidgezou George Zou Approved (Document resp) 4 PUBLIC PRODUCT SPECIFICATION 2/1301-BMR802Technical Specification Checked PUB-1M series Zou DC/DC Converters jidgezou George Isolated 1W Unregulated Single Output Date 3/17/2023 Rev March 2023 28701-BMR802 Rev. E D © Flex Absolute Maximum Ratings Characteristics min max Unit TP1 Operating Temperature (see Thermal Consideration section) -40 typ +110 °C TS Storage temperature -55 +125 °C VI Input voltage Range (base on nominal input voltage) -10 +10 % Viso Isolation voltage (input to output test voltage in 1minute) 3000 Vdc Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the Electrical Specification section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Fundamental Circuit Diagram 5 PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) 2 (7) No. jidgezou George Zou 2/1301-BMR802Technical Specification Approved (Document resp) Checked Date PUB-1M series Zou DC/DC Converters jidgezou George Isolated 1W Unregulated Single Output Rev March 2023 28701-BMR802 Rev. E D 3/17/2023 © Flex Electrical Specification PUB-1M series Typical values given at: TP1 = +25°C, unless otherwise specified under Conditions. Input Voltage (±10%) V Output Voltage V Output Current mA Efficiency (typ.) half of max IO % Efficiency (typ.) max IO % Capacitive Load note 1 µF PUB0505S1M 5 5 200 67.5 76 470 PUB1205S1M 12 5 200 75 81 470 PUB2412S1M 24 5 200 65 75 470 Part Number Characteristics CI Internal input capacitance PO Output power CISO Isolation capacitance RISO Isolation resistance VOi Conditions min typ max 1 µF 1 95 TP1 = +25°C , IO = max IO -5 Minimum load TP1 = +25°C 0 Line regulation VLL to VHL, max IO Load regulation VO = 5 V , ILL - IHL, at typ. Vin fs Switching frequency 0-100 % of max IO VOac Output ripple & noise 20 MHz bandwidth limit, see Note 2 Note 1: The maximum capacitive load is test by normal input and constant resistive load. Note 2: The Output ripple & noise is under nominal Vin and max IO with 0.1 µF /50 V MLCC W pF 10 Voltage accuracy Unit GΩ +5 %VO 1.2 1.3 %VO 7.5 10 %VO 100 mVp-p A 20 kHz 6 PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) 3 (7) No. jidgezou George Zou 2/1301-BMR802Technical Specification Approved (Document resp) Checked Date PUB-1M series Zou DC/DC Converters jidgezou George Isolated 1W Unregulated Single Output 3/17/2023 Rev March 2023 28701-BMR802 Rev. E D © Flex Typical Characteristics PUB-1M series 100% 100% 80% 80% Efficiency Efficiency Efficiency Efficiency 60% 4.5Vin 40% 5.0Vin 20% 0% 10 20 30 40 50 60 70 80 10.8Vin 40% 12.0Vin 20% 5.5Vin 0 60% 90 0% 100 Load (%) 13.2Vin 0 10 PUB0505S1M Efficiency vs. load current at TP1 = +25°C. Efficiency 50 60 70 Load (%) 80 90 100 Load (%) 100 80% 80 60% 60 21.6Vin 40% 40 24.0Vin 20% 0.5 m/s 20 26.4Vin 0 10 20 30 40 50 Load (%) 60 70 80 90 0 100 Nat. Conv. -40 -20 PUB2405S1M Efficiency vs. load current at TP1 = +25°C. 0 20 40 60 80 100 120 [°C] Available load vs. ambient air temperature and airflow. See Thermal Consideration section. Output Voltage Accuracy Output Voltage Accuracy 30% 30% 4.5Vin 5.0Vin 20% 10% 10.8Vin 12.0Vin 13.2Vin 20% 5.5Vin Accuracy Accuracy 40 Operating Ambient Temperature Curve 100% 0% -10% -20% 30 PUB1205S1M Efficiency vs. load current at TP1 = +25°C. Efficiency 0% 20 10% 0% -10% 0 10 20 30 40 50 60 70 80 90 Load (%) PUB0505S1M Output voltage accuracy vs. load current at TP1 = +25°C. 100 -20% 0 10 20 30 40 50 60 70 80 90 Load (%) PUB1205S1M Output voltage accuracy vs. load current at TP1 = +25°C. 100 7 PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) 4 (7) No. jidgezou George Zou 2/1301-BMR802Technical Specification Approved (Document resp) Checked Date PUB-1M series Zou DC/DC Converters jidgezou George Isolated 1W Unregulated Single Output Rev March 2023 28701-BMR802 Rev. E D 3/17/2023 © Flex Typical Characteristics PUB-1M series Output Voltage Accuracy Load Regulation 21.6Vin 24.0Vin 26.4Vin Accuracy 20% 10% 0% 15% 10 20 30 40 50 60 Load (%) 70 80 90 100 10% Regulation 30 40 50 60 70 80 12.0Vin 13.2Vin 5% 0% 30 40 50 60 Load (%) 70 80 90 100 PUB1205S1M Output voltage with load variation vs. load current at TP1 = +25°C. Output Ripple & Noise Output voltage ripple at: TP1 = +25°C, VI = 5 V, VO = 5 V IO = 200 mA resistive load. 15% 90 100 21.6Vin 24.0Vin 10% Regulation 10.8Vin 20 20 Load Regulation 15% 10 10 PUB0505S1M Output voltage with load variation vs. load current at TP1 = +25°C. Load Regulation 0 0 Load (%) PUB2405S1M Output voltage accuracy vs. load current at TP1 = +25°C. -5% 5.5Vin 0% -5% 0 5.0Vin 5% -10% -20% 4.5Vin 10% Regulation 30% 26.4Vin 5% 0% -5% 0 10 20 30 40 50 60 Load (%) 70 80 90 100 PUB2405S1M Output voltage with load variation vs. load current at TP1 = +25°C. Output Ripple & Noise Trace: output voltage (50 mV/div.). Time scale: (10 µs/div.). 20 MHz bandwidth filter +0.1 µF Output voltage ripple at: TP1 = +25°C, VI = 12 V, VO = 5 V IO = 200 mA resistive load. Trace: output voltage (50 mV/div.). Time scale: (10 µs/div.). 20 MHz bandwidth filter +0.1 µF Prepared (Subject resp) 5 (7) No. jidgezou George Zou Approved (Document resp) 8 PUBLIC PRODUCT SPECIFICATION 2/1301-BMR802Technical Specification Checked PUB-1M series Zou DC/DC Converters jidgezou George Isolated 1W Unregulated Single Output Date 3/17/2023 Rev 28701-BMR802 Rev. E D March 2023 © Flex Typical Characteristics PUB-1M series Output Ripple & Noise Output voltage ripple at: TP1 = +25°C, VI = 24 V, VO = 5 V IO = 200 mA resistive load. Trace: output voltage (50 mV/div.). Time scale: (10 µs/div.). 20 MHz bandwidth filter +0.1 µF Start-up Start-up, enabled by connecting VI at: TP1 = +25°C, VI = 5 V, VO = 5 V IO = 200 mA resistive load. Shut-down Top trace: Input voltage (2 V/div.). Bottom trace: Output voltage (2 V/div.). Time scale: (1 ms/div.). Start-up Start-up, enabled by connecting VI at: TP1 = +25°C, VI = 12 V, VO = 5 V IO = 200 mA resistive load. Shut-down, closed by disconnecting VI at: TP1 = +25°C, VI = 5 V, VO = 5 V IO = 200 mA resistive load. Top trace: Input voltage (2 V/div.). Bottom trace: Output voltage (2 V/div.). Time scale: (2 ms/div.). Shut-down Top trace: Input voltage (5 V/div.). Bottom trace: Output voltage (2 V/div.). Time scale: (1 ms/div.). Shut-down, closed by disconnecting VI at: TP1 = +25°C, VI = 12 V, VO = 5 V IO = 200 mA resistive load. Top trace: Input voltage (5 V/div.). Bottom trace: Output voltage (2 V/div.). Time scale: (2 ms/div.). Prepared (Subject resp) 2/1301-BMR802Technical Specification Checked PUB-1M series Zou DC/DC Converters jidgezou George Isolated 1W Unregulated Single Output Date 3/17/2023 Rev 28701-BMR802 Rev. E D March 2023 © Flex Typical Characteristics PUB-1M series Start-up Start-up, enabled by connecting VI at: TP1 = +25°C, VI = 24 V, VO = 5 V IO = 200 mA resistive load. 6 (7) No. jidgezou George Zou Approved (Document resp) 9 PUBLIC PRODUCT SPECIFICATION Shut-down Top trace: Input voltage (10 V/div.). Bottom trace: Output voltage (2 V/div.). Time scale: (1 ms/div.). Shut-down, closed by disconnecting VI at: TP1 = +25°C, VI = 24 V, VO = 5 V IO = 200 mA resistive load. Top trace: Input voltage (10 V/div.). Bottom trace: Output voltage (2 V/div.). Time scale: (2 ms/div.). PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) 10 1 (4) No. 3/1301-BMR802 Technical Specification jidgezou George Zou Approved (Document resp) PUB-1MGeorge seriesZou DC/DC Converters jidgezou Checked Isolated 1W Unregulated Single Output Date 3/31/2020 Rev 28701-BMR802 Rev. E C March 2023 © Flex EMC Specification Conducted EMI measured according to EN55032, CISPR 32 and FCC part 15J (see test set-up). See Design Note 029 for further information. The minimum switching frequency is 20 kHz. The EMI characteristics below is measured at normal input and max IO. Optional external filter for class B Suggested external input filter in order to meet class B in EN 55032, CISPR 32 and FCC part 15J. PUB0505S1M Test set-up Layout recommendations The radiated EMI performance of the product will depend on the PWB layout and ground layer design. It is also important to consider the stand-off of the product. If a ground layer is used, it should be connected to the output of the product and to the equipment ground or chassis. A ground layer will increase the stray capacitance in the PWB and improve the high frequency EMC performance. EMI external circuit Series L1 C1 PUB05-1M 4.7µH 10µF PUB12-1M 4.7µH 10µF PUB24-1M 22µH 10µF Output ripple and noise Output ripple and noise is measured according to figure below. See Design Note 022 for detailed information. Based on different applications or PCB layout conditions, the EMI requirement may be varied. Recommend to reserve Cy1 for better EMI performance. Depending on the different requirement of end users, the value of Cy1 could be adjusted from 33pF to 470pF. Output ripple and noise test setup PUB0505S1M EMI with filter PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) PUB-1MGeorge seriesZou DC/DC Converters jidgezou 2 (4) No. 3/1301-BMR802 Technical Specification jidgezou George Zou Approved (Document resp) 11 Checked Isolated 1W Unregulated Single Output Operating Information Input Voltage Converter with 10% input voltage range, mainly for isolated power in industrial applications. For example, the input voltage range 4.5 to 5.5 Vdc meets requirement of general industrial used for 5Vdc system. The input voltage should never exceed the absolute voltage of the converter, and the ambient temperature must be limited to absolute max +110°C. The output voltage related to input voltage. Take 5Vin and 5Vo product as an example, if input voltage above 5V, the output voltage will higher than 5V. Below 5V and the output voltage starts to track the input voltage. Short duration transient disturbances can occur on the DC distribution and input of the product when a short circuit fault occurs on the equipment side of a protective device (fuse or circuit breaker). The voltage level, duration and energy of the disturbance are dependent on the particular DC distribution network characteristics and can be sufficient to damage the product unless measures are taken to suppress or absorb this energy. The transient voltage can be limited by capacitors and other energy absorbing devices like Zener diodes connected across the positive and negative input conductors at a number of strategic points in the distribution network. The end-user must secure that the transient voltage will not exceed the value stated in the Absolute maximum ratings. ETSI TR 100 283 examines the parameters of DC distribution networks and provides guidelines for controlling the transient and reduce its harmful effect. Turn-off Input Voltage The products do not have under voltage lock-out function. Please make sure the input voltage of each module is correct working range. Input and Output Impedance The impedance of both the input source and the load will interact with the impedance of the product. It is important that the input source has low characteristic impedance.The product are designed for stable operation without external capacitors. With a 10µF capacitors connected to the input could reduce the input noise cause by parasitic inductance. External Decoupling Capacitors When powering loads with significant dynamic current requirements, the voltage regulation at the load can be improved by addition of decoupling capacitors at the load. The most effective technique is to locate low ESR ceramic and electrolytic capacitors as close to the load as possible, using several parallel capacitors to lower the effective ESR. The ceramic capacitors will handle high-frequency dynamic load Date 3/31/2020 Rev 28701-BMR802 Rev. E C March 2023 © Flex changes while the electrolytic capacitors are used to handle low frequency dynamic load changes. It is equally important to use low resistance and low inductance PWB layouts and cabling. External decoupling capacitors will become part of the product’s control loop. The control loop is optimized for a wide range of external capacitance and the maximum and minimum recommended value that could be used without any additional analysis is found in the Electrical specification. The ESR of the capacitors is a very important parameter. Stable operation is guaranteed with a verified ESR value of >1 mΩ across the output connections. For further information please contact your local Flex Power Modules representative. Parallel Operation This product is not designed for paralleling without using external current sharing circuits. See Design Note 006 for detailed information. Over Current Protection (OCP) The products include current limiting circuitry for protection at continuous overload. The OCP works in a hiccup mode and will make continous attempts to start up and will resume normal operation automatically after removal of the over current condition. The load distribution should be designed for the specified maximum output short circuit current. PUBLIC PRODUCT SPECIFICATION Prepared (Subject resp) 3/1301-BMR802 Technical Specification PUB-1MGeorge seriesZou DC/DC Converters jidgezou Checked Isolated 1W Unregulated Single Output Date Rev 28701-BMR802 Rev. E C 3/31/2020 © Flex Connections Thermal Consideration General The products are designed to operate in different thermal environments and sufficient cooling must be provided to ensure reliable operation. For products mounted on a PWB without a baseplate attached, cooling is achieved mainly by conduction, from the pins to the host board, and convection, which is dependant on the airflow across the product. Increased airflow enhances the cooling of the product. The Output Current Derating graph found in the Output section for each model provides the available output current vs. ambient air temperature and air velocity. The product is tested on a 95 x 85 mm, 35 µm (1 oz), 2-layer test board mounted horizontally in a space with a volume of 300(L) x 300(W) x 200(H) mm. Bottom View PUBxxxxS1M series Pin 1 Designation -Vin Function Negative Input 2 +Vin Positive Input 4 -Vo Negative Output 5 +Vo Positive Output 8 NC No-connect Connections Definition of product operating temperature The temperature at the positions P1, P2 (TP1, TP2) should not exceed the maximum temperatures in the table below. The number of measurement points may vary with different thermal design and topology. Temperatures above maximum measured at the reference point P1, P2 are not allowed and may cause permanent damage. Position Description Max Temp. P1 Driver, Reference point TP1=110ºC P2 PWB TP2=110ºC Pin side (baseplate module) 3 (4) No. jidgezou George Zou Approved (Document resp) 12 Bottom View PUBxxxxD1M series Pin 1 Designation -Vin Function Negative Input 2 +Vin Positive Input 4 COM Common 5 -Vo Negative Output 7 +Vo Positive Output 10 NC No-connect March 2023 PUBLIC PRODUCT SPEC. MECHANICAL Prepared (Subject resp) No. jidgezou George Zou 4/1301-BMR802 Technical Specification Date Rev PUB-1M series DC/DC Converters jidgezou George Zou Isolated 1W Unregulated Single Output Approved (Document resp) Checked 3/24/2020 28701-BMR802 Rev. E B 13 1 (2) March 2023 © Flex Mechanical Information - Surface Mounting Version PUBxxxxS1M PUBxxxxD1M All component placements – whether shown as physical components or symbolical outline – are for reference only and are subject to change throughout the product’s life cycle, unless explicitly described and dimensioned in this drawing. 14 PUBLIC PRODUCT SPEC. Prepared (Subject resp) 1 (3) No. jidgezou George Zou 5/1301 - BMR802 Technical Specification Approved (Document resp) PUB-1MGeorge seriesZou DC/DC Converters jidgezou Checked Date 3/17/2023 Isolated 1W Unregulated Single Output Soldering Information - Surface Mounting The surface mount product is intended for forced convection or vapor phase reflow soldering in SnPb and Pb-free processes. The reflow profile should be optimised to avoid excessive heating of the product. It is recommended to have a sufficiently extended preheat time to ensure an even temperature across the host PWB and it is also recommended to minimize the time in reflow. Rev 28701-BMR802 Rev. E C March 2023 © Flex Pb-free solder processes For Pb-free solder processes, the product is qualified for MSL 1 according to IPC/JEDEC standard J-STD-020C. During reflow TPRODUCT must not exceed 250 °C at any time. Thermocouple Attachment Top of PWB near front center for measurement of maximum product temperature, TPRODUCT A no-clean flux is recommended to avoid entrapment of cleaning fluids in cavities inside the product or between the product and the host board, since cleaning residues may affect long time reliability and isolation voltage. General reflow process specifications Pb-free Average ramp-up (TPRODUCT) 3°C/s max Typical solder melting (liquidus) temperature TL Minimum reflow time above TL 221°C Pin near the tail for measurement of minimum pin (solder joint) temperature, TPIN 60 s Minimum pin temperature TPIN 235°C Peak product temperature TPRODUCT 250°C Average ramp-down (TPRODUCT) 6°C/s max Maximum time 25°C to peak 8 minutes Delivery Package Information The products are delivered in antistatic tape & reel. Temperature Tape reel Specifications – SMD TPRODUCT maximum TPIN minimum Pin profile TL Time in preheat / soak zone Time 25°C to peak Time in reflow Product profile Material Antistatic PS Surface resistance 105 < Ohm/square < 1012 6.7 kg full reel for PUBxxxxS1M 5.4 kg full reel for PUBxxxxD1M 1.4 g / pc Tape reel weight Module weight PUB-1M series Time Minimum Pin Temperature Recommendations Pin near the tail is chosen as reference location for the minimum pin temperature recommendation since this will likely be the coolest solder joint during the reflow process. Lead-free (Pb-free) solder processes For Pb-free solder processes, a pin temperature (TPIN) in excess of the solder melting temperature (TL, 217 to 221°C for SnAgCu solder alloys) for more than 60 seconds and a peak temperature of 245°C on all solder joints is recommended to ensure a reliable solder joint. Maximum Product Temperature Requirements Top of the product PWB near front center is chosen as reference location for the maximum (peak) allowed product temperature (TPRODUCT) since this will likely be the warmest part of the product during the reflow process. 1Tape Reel = 500 converters for PUBxxxxS1M 1Tape Reel = 400 converters for PUBxxxxD1M All dimensions in mm Note: pick up positions refer to center of pocket. See mechanical drawing for exact location on product. 15 PUBLIC PRODUCT SPEC. Prepared (Subject resp) 2 (3) No. jidgezou George Zou 5/1301 - BMR802 Technical Specification Approved (Document resp) PUB-1MGeorge seriesZou DC/DC Converters jidgezou Checked Isolated 1W Unregulated Single Output Date 3/17/2023 Rev 28701-BMR802 Rev. E C © Flex Product Qualification Specification Characteristics External visual inspection IPC-A-610 Change of temperature (Temperature cycling) MI-STD-202G, method 107G Temperature range Number of cycles Dwell/transfer time -55 to 125°C 1000 30 min/0-1 min Cold (in operation) IEC 60068-2-1 Ad Temperature TA Duration -45°C 72 h Damp heat MIL-STD-202G, Method 103B Temperature Humidity Duration 85°C 95 % RH 1000 hours Dry heat IEC 60068-2-2 Bd Temperature Duration 125°C 1000 h Electrostatic discharge susceptibility IEC 61000-4-2 Air model Contact model 8000 V 6000 V Mechanical shock MIL-STD-202G, method 213B Peak acceleration Duration 100 g 6 ms Moisture reflow sensitivity 1 J-STD-020C Level 1 (Pb Free) 250°C Operational life test MIL-STD-202G, method 108A Duration 1000 h Robustness of terminations IEC 60068-2-21 Test Ua1 IEC 60068-2-21 Test Ue1 Through hole mount products Surface mount products All leads All leads Solderability J-STD-002 Preconditioning Temperature, Pb-free Steam ageing 8 h 245°C Vibration MIL-STD-202G, method 201A Frequency Displacement Duration 10 to 55 Hz 0.06 inch 2 h in each direction Notes 1 Only for products intended for reflow soldering (surface mount products) March 2023
PUB1205S1M 价格&库存

很抱歉,暂时无法提供与“PUB1205S1M”相匹配的价格&库存,您可以联系我们找货

免费人工找货