0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NUS-2412C1

NUS-2412C1

  • 厂商:

    DIWELL

  • 封装:

    SMD5 模块

  • 描述:

    隔离模块 直流转换器 1 输出 12V 84mA 21.6V - 26.4V 输入

  • 数据手册
  • 价格&库存
NUS-2412C1 数据手册
NU-C1 SERIES 1W UNREGULATED FEATURES           UP TO 1W UNREGULATED OUTPUT POWER 100% BURN IN HIGH EFFICIENCY SMD TECHNOLOGY LOW COST UL 94V-0 PACKAGE MATERIAL CUSTOM SOLUTIONS AVAILABLE MTBF>880,000 HOURS RoHS COMPLIANT 3 YEARS WARRANTY OUTPUT SPECIFICATIONS INPUT SPECIFICATIONS Voltage Set-point Accuracy +/-2% max. Input Voltage Range Temperature Coefficient +/-0.03%/°C Input Filter Capacitor Type 100mVp-p max. Protection Fuse Recommended 1 Ripple & Noise(20MHz BW) Line Regulation2 3 Load Regulation Minimum Load Short Circuit Protection S-Suffix +/-1.2% max. +/-8% max. GENERAL SPECIFICATIONS 10% of Full Load Efficiency 70%-82% 4 Momentary Isolation Voltage 1500 VDC min. Continuous Isolation Resistance 10 ohms min. 80pF max. Switching Frequency 100KHz typ. MTBF ENVIRONMENTAL SPECIFICATIONS s-suffix Storage Temperature Humidity Cooling 9 Isolation Capacitance 5 Operating Temperature +/-10% max. Weight -40 °C to +85°C Case Material -40 °C to +100°C Case Size -55°C to +125°C Radiated Emissions >880,000 Hours 1.1g typ. Non-Conductive Plastic 12.9mm*10.9mm*7.1mm EN55032 Class B 95% max. Free-Air Convection ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD , AND 25°C UNLESS OTHERWISE NOTED. 1 2 3 4 5 Measured with 1uF ceramic capacitor connect to the output pins. Line Regulation is for a 1.0% change in input Voltage. Load Regulation is for output load current change from 20% to 100%. For 10 seconds. MIL-HDBK-217F@25°C, Ground Benign. DANUBE http://www.danube.com.tw 1 2018/01/02  SELECTION GUIDE 1W 1500VDC ISOLATION INPUT MODEL NUMBER OUTPUT OUTPUT INPUT6 VOLTAGE VOLTAGE CURRENT CURRENT(mA) EFF (VDC) (VDC) (mA) FULL NO LOAD LOAD ISOLATION PACKAGE (%)7 (VDC) NUS-03.303.3C1 3.3 3.3 300 406 40 74 1500 C NUS-0503.3C1(S) 5 3.3 300 267 35 75 1500 C NUS-0505C1(S) 5 5 200 260 35 77 1500 C NUS-0512C1(S) 5 12 84 257 25 78 1500 C NUS-0515C1(S) 5 15 67 253 28 79 1500 C NUS-1203.3C1(S) 12 3.3 300 111 14 75 1500 C NUS-1205C1(S) 12 5 200 107 14 78 1500 C NUS-1212C1(S) 12 12 84 103 10 81 1500 C NUS-1215C1(S) 12 15 67 102 12 82 1500 C NUS-2405C1(S) 24 5 200 54 11 76 1500 C NUS-2412C1(S) 24 12 84 54 11 76 1500 C NUS-2415C1(S) 24 15 67 54 11 76 1500 C Note: Other input to output voltages may be available. Please contact factory. 6 7 NOMINAL INPUT VOLTAGE. NOMINAL INPUT VOLTAGE, FULL LOAD. DANUBE http://www.danube.com.tw 2 2018/01/02  MECHANICAL DIMENSIONS & RECOMMENDED FOOTPRINT DETAILS PACKAGE ”C” PIN SINGLE 1 -Vin 2 +Vin 4 -Vout 5 +Vout 8 NC NOTE : All Dimensions are in mm [inches] 1. Pin Size is 0.50x0.30mm[0.02x0.01”] 2. Pin is Tolerance .XX= ±0.07mm 3. Tolerance .X or .XX= ±0.5mm  REFLOW SOLDERING CURVE Remark:The curve applies only to the hot air reflow soldering. DANUBE http://www.danube.com.tw 3 2018/01/02  SIMPLIFIED SCHEMATIC +Vin +Vout OSCILLATOR DRIVER -Vout -Vin  TYPICAL APPLICATIONS INPUT OUTPUT +Vin +Vout DC-DC CONVERTER -Vin LOAD -Vout  TYPICAL PERFORMANCE CURVES Specifications typical at ta=25 °C, nominal input voltage, rated output current unless otherwise specified. EFFICIENCY(%) OUTPUT LOAD VS EFFICIENCY TEMPERATURE DERATING 80.0 60.0 40.0 20.0 0.0 0 20 40 60 80 100 % OF RATED LOAD(%) DANUBE http://www.danube.com.tw 4 2018/01/02  INPUT FUSE SELECTION GUIDE 1W 1500VDC ISOLATION 4.5-5.5V 10.8-13.2V 21.6-26.4V INPUT VOLTAGE(VDC) INPUT VOLTAGE(VDC) INPUT VOLTAGE(VDC) 750mA Slow-Blow Type 300mA Slow-Blow Type 150mA Slow-Blow Type INPUT OUTPUT +Vin +Vout Fuse DC-DC CONVERTER -Vi n -Vout Note: Certain applications may require the installation of external fuse in front of the input. NU-C1 SERIES APPLICATION NOTES: EXTERNAL CAPACITANCE REQUIREMENTS: Output filtering is required for operation. A minimum of 10uF is needed. Output capacitance may be increased for additional filtering, not to exceed 220uF. To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm from DC to 250KHz is required. We Can Offer EMC-Filter According To EN55032 Class B. Negative Outputs: A negative output voltage may be obtained by connecting the +OUT to circuit ground and connecting –OUT as the negative output. FOR MORE INFORMATION CALL: Danube Enterprise Co., Ltd. Tel: 886-7-3755165 Fax: 886-7-3755330 Home Page http://www.danube.com.tw DANUBE E-mail: danube@ms10.hinet.net http://www.danube.com.tw 5 2018/01/02
NUS-2412C1 价格&库存

很抱歉,暂时无法提供与“NUS-2412C1”相匹配的价格&库存,您可以联系我们找货

免费人工找货