NU-E2K SERIES
2W UNREGULATED
FEATURES
UP TO 2W UNREGULATED OUTPUT POWER
100% BURN IN
HIGH EFFICIENCY
SMD TECHNOLOGY
LOW COST
UL 94V-0 PACKAGE MATERIAL
CUSTOM SOLUTIONS AVAILABLE
MTBF>888,000 HOURS
RoHS COMPLIANT
3 YEARS WARRANTY
OUTPUT SPECIFICATIONS
INPUT SPECIFICATIONS
Voltage Set-point Accuracy
+/-2% max. Input Voltage Range
Temperature Coefficient
+/-0.03%/°C Input Filter
Capacitor Type
150mVp-p max. Protection
Fuse Recommended
Ripple & Noise(20MHz BW) 1
Line Regulation
2
Load Regulation 3
Minimum Load
Short Circuit Protection
S-Suffix
+/-1.2% max.
+/-8% max.
Storage Temperature
GENERAL SPECIFICATIONS
10% of Full Load Efficiency
72%-83%
Momentary Isolation Voltage 4
3000 VDC min.
Continuous Isolation Resistance
10 ohms min.
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
+/-10% max.
9
Isolation Capacitance
80pF max.
Switching Frequency
100KHz max.
MTBF 5
>880,000 Hours
-40 °C to +85°C Weight
1.2g typ.
-55°C to +125°C Case Material
Humidity
95% max. Case Size
Cooling
Free-Air Convection Radiated Emissions
Non-Conductive Plastic
15.24mm*11.1mm*7.1mm
EN55032 Class A
ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD , AND 25°C UNLESS OTHERWISE NOTED.
1
2
3
4
5
Measured with 1uF ceramic capacitor connect to the output pins.
Line Regulation is for a 1.0% change in input Voltage.
Load Regulation is for output load current change from 20% to 100%.
For 3 seconds.
MIL-HDBK-217F@25°C, Ground Benign.
DANUBE
http://www.danube.com.tw
1
2018/06/26
SELECTION GUIDE
2W 3000VDC ISOLATION
INPUT
MODEL
NUMBER
OUTPUT
OUTPUT
INPUT 6
VOLTAGE VOLTAGE CURRENT CURRENT(mA) EFF
(VDC)
(VDC)
(mA)
FULL
NO
LOAD
LOAD
ISOLATION
PACKAGE
(%) 7
(VDC)
NUS-0505E2K(S)
5
5
400
513
60
78
3000
E
NUS-0512E2K(S)
5
12
167
500
60
80
3000
E
NUS-0515E2K(S)
5
15
133
488
60
81
3000
E
NUD-0505E2K(S)
5
+/-5
+/-200
513
60
78
3000
E
NUD-0512E2K(S)
5
+/-12
+/-84
500
60
80
3000
E
NUD-0515E2K(S)
5
+/-15
+/-67
488
60
81
3000
E
NUS-1205E2K(S)
12
5
400
208
30
80
3000
E
NUS-1212E2K(S)
12
12
167
203
30
81
3000
E
NUS-1215E2K(S)
12
15
133
198
30
83
3000
E
NUD-1205E2K(S)
12
+/-5
+/-200
208
30
80
3000
E
NUD-1212E2K(S)
12
+/-12
+/-84
203
30
81
3000
E
NUD-1215E2K(S)
12
+/-15
+/-67
198
30
83
3000
E
NUS-2405E2K(S)
24
5
400
107
15
78
3000
E
NUS-2412E2K(S)
24
12
167
104
15
79
3000
E
NUS-2415E2K(S)
24
15
133
102
15
90
3000
E
NUD-2405E2K(S)
24
+/-5
+/-200
107
15
78
3000
E
NUD-2412E2K(S)
24
+/-12
+/-84
104
15
79
3000
E
NUD-2415E2K(S)
24
+/-15
+/-67
102
15
80
3000
E
Note: Other input to output voltages may be available. Please contact factory.
6
7
NOMINAL INPUT VOLTAGE.
NOMINAL INPUT VOLTAGE, FULL LOAD.
DANUBE
http://www.danube.com.tw
2
2018/06/26
MECHANICAL DIMENSIONS &
RECOMMENDED FOOTPRINT DETAILS
PACKAGE ”E”
PIN
SINGLE
DUAL
1
-Vin
-Vin
2
+Vin
+Vin
3
NC
NC
5
-Vout
Com
6
NC
-Vout
7
NC
NC
8
+Vout
+Vout
10
NC
NC
11
NC
NC
12
NC
NC
NOTE : All Dimensions are in mm [inches]
1. Pin Size is 0.50x0.30mm[0.02x0.01”]
2. Pin is Tolerance .XX= ±0.07mm
3. Tolerance .X or .XX= ±0.5mm
DANUBE
http://www.danube.com.tw
3
2018/06/26
REFLOW SOLDERING CURVE
Remark:The curve applies only to the hot air reflow soldering.
SIMPLIFIED SCHEMATIC
SINGLE OUTPUT
DUAL OUTPUT
+Vin
+Vout
OSCILLATOR
DRIVER
+Vin
+Vout
OSCILLATOR
DRIVER
-Vout
-Vin
COMMON
-Vin
-Vout
TYPICAL APPLICATIONS
SINGLE OUTPUT
INPUT
DUAL OUTPUT
OUTPUT
+Vin
+Vout
OUTPUT
INPUT
+Vin
+Vout
LOAD1
DC-DC
CONVERTER
-Vin
LOAD
Common
DC-DC
CONVERTER
-Vin
-Vout
LOAD2
-Vout
TYPICAL PERFORMANCE CURVES
Specifications typical at ta=25 °C, nominal input voltage, rated output current unless otherwise specified.
OUTPUT LOAD VS EFFICIENCY
DANUBE
TEMPERATURE DERATING
http://www.danube.com.tw
4
2018/06/26
INPUT FUSE SELECTION GUIDE
2W 3000VDC ISOLATION
4.5-5.5V
10.8-13.2V
21.6-26.4V
INPUT VOLTAGE(VDC)
INPUT VOLTAGE(VDC)
INPUT VOLTAGE(VDC)
800mA Slow-Blow Type
300mA Slow-Blow Type
INPUT
170mA Slow-Blow Type
OUTPUT
+Vin
+Vout
Fuse
DC-DC
CONVERTER
-Vin
-Vout
Note: Certain applications may require the installation of external fuse in front of the input.
NU-E2K SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS:
Output filtering is required for operation. A minimum of 10uF is needed. Output capacitance may be
increased for additional filtering, not to exceed 220uF.
To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm
from DC to 250KHz is required.
We Can Offer EMC-Filter According To EN55032 Class B.
Negative Outputs:
A negative output voltage may be obtained by connecting the +OUT to circuit ground and
connecting –OUT as the negative output.
FOR MORE INFORMATION CALL:
Danube Enterprise Co., Ltd.
Tel: 886-7-3755165
Fax: 886-7-3755330
Home Page
http://www.danube.com.tw
DANUBE
E-mail: danube@ms10.hinet.net
http://www.danube.com.tw
5
2018/06/26
很抱歉,暂时无法提供与“NUS-2412E2K”相匹配的价格&库存,您可以联系我们找货
免费人工找货