PRD SERIES
1W REGULATED
FEATURES
SINGLE IN LINE PACKAGE
UP TO 1W REGULATED OUTPUT POWER
100% BURNED IN
EFFICIENCY UP TO 60%
INTERNAL SMD TECHNOLOGY
NO EXTERNAL COMPONENTS REQUIRED
LOW COST
1500VDC ISOLATION
UL 94V-0 PACKAGE MATERIAL
CUSTOM SOLUTIONS AVAILABLE
RoHS COMPLIANT
3 YEARS WARRANTY
OUTPUT SPECIFICATIONS
Voltage Setpoint Accuracy
+/-3% max Input Voltage Range
Temperature Coefficient
Ripple & Noise(20MHz BW)
Line Regulation
1
2
+/-10% max
+/-0.05%/°C Input Filter
Capacitor Typ
100mVp-p max Protection
Fuse Recommended
+/-2% max
3
Load Regulation
+/-2% max
Minimum Load
GENERAL SPECIFICATIONS
10% of Full Load Efficiency
Short Circuit Protection
Short Circuit Restart
Transient Response
INPUT SPECIFICATIONS
5
Current Limit Protection Isolation Voltage
Humidity
Cooling
9
10 ohms min
100uS max Isolation Capacitance
80pF max
Switching Frequency
100KHz min
ENVIRONMENTAL SPECIFICATIONS
Storage Temperature
1500VDC min
Automatic Isolation Resistance
MTBF
Operating Temperature
50% min
4
6
>1,800,000 Hours
Weight
-25 °C to +71 °C Case Material
-55 °C to +125 °C Case Size
2.3g Typ
Non-Conductive Plastic
19.6mm*7.5mm*10.2mm
95% max Conducted Emissions
Free-Air Convection Radiated Emissions
EN55022 Class A
EN55022 Class A
ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD , AND 25°C UNLESS OTHERWISE NOTED.
1
2
3
4
5
6
Measured with 1uF ceramic capacitor connect to the output pins.
High Line to Low Line.
Load Regulation is for output load current change from 10% to 100%.
1500VDC for 10 seconds
25% Step Load Change.
MIL-HDBK-217F @25 °C , Ground Benign.
DANUBE
http://www.danube.com.tw
5-1
2015/11/30
SELECTION GUIDE
1W OUTPUT 1500VDC ISOLATION
MODEL
NUMBER
INPUT
OUTPUT
OUTPUT
VOLTAGE VOLTAGE CURRENT
(VDC)
(VDC)
(mA)
INPUT
CURRENT(mA) EFF ISOLATION
FULL
NO
LOAD
LOAD
(%)
(VDC)
OUTPUT
POWER
(Watt)
PRD-0505G
4.5-5.5
+/-5
+/-100
350
35
57
1500
1
PRD-0512G
4.5-5.5
+/-12
+/-42
350
50
57
1500
1
PRD-0515G
4.5-5.5
+/-15
+/-34
350
60
57
1500
1
PRD-1205G
10.8-13.2
+/-5
+/-100
141
20
59
1500
1
PRD-1215G
10.8-13.2
+/-15
+/-34
134
30
62
1500
1
PRD-2405G
21.6-26.4
+/-5
+/-100
70
5
60
1500
1
PRD-2412G
21.6-26.4
+/-12
+/-42
70
40
60
1500
1
Note: Other input to output voltages may be available. Please contact factory.
DANUBE
http://www.danube.com.tw
5-2
2015/11/30
MECHANICAL DIMENSIONS &
RECOMMENDED FOOTPRINT DETAILS
PACKAGE ”G”
19.6[0.77]
FRONT
VIEW
PIN
DUAL
1
+Vin
2
-Vin
5
-Vout
6
Common
7
+Vout
10.2[0.40]
3.81[0.15]
5.08[0.20]
2.54[0.10]
7.5[0.30]
NOTE : All Dimensions In mm(Inches)
BOTTOM VIEW
1 2
1. Pin Size is 0.50x0.30mm[0.02x0.01”]
5 6 7
2.18[0.086]
2. Pin is Tolerance .XX= ±0.05mm
3. Tolerance .X
1.2[0.05]
or
.XX= ±0.5mm
All dimensions are in mm[inches]
SIMPLIFIED SCHEMATIC
TYPICAL APPLICATIONS
INPUT
+Vin
REGULATOR
+Vout
OSCILLATOR
DRIVER
+Vin
REGULATOR
Common
DC-DC
CONVERTER
-Vin
DANUBE
+Vout
LOAD1
Com.
-Vout
-Vin
OUTPUT
LOAD2
-Vout
http://www.danube.com.tw
5-3
2015/11/30
TYPICAL PERFORMANCE CUREVES
Specifications typical at ta=25 °C,nominal input voltage , rated output current unless otherwise specified.
EFFICIENCY VS LOAD
125%
EFFICIENCY(%)
OUTPUT POWER(%)
DERATING CURVE
100%
SAFE
OPERATING
AREA
75%
50%
25%
80.0
60.0
40.0
20.0
0%
0.0
-25
0
25
50
70
100
0
TA(degree C)
20
40
60
80
100
%OF RATED LOAD(%)
INPUT FUSE SELECTION GUIDE
4.5-5.5V
10.8-13.2V
21.6-26.4V
INPUT VOLTAGE(VDC)
INPUT VOLTAGE(VDC)
INPUT VOLTAGE(VDC)
500mA Slow-Blow Type
250mA Slow-Blow Type
INPUT
100mA Slow-Blow Type
OUTPUT
Fuse
+Vin
+Vout
DC-DC
CONVERTER
-Vin
-Vout
Note: Certain applications may require the installation of external fuse in front of the input.
DANUBE
http://www.danube.com.tw
5-4
2015/11/30
PRD SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS:
No external capacitance is required for operation of the PRD series.
To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm
from DC to 250KHz is required.
External output capacitance is not required for operation, however it is recommended that 10uF
tantalum and 0.1uF ceramic capacitance be selected for reduced system noise.
Additional output capacitance may be added for increased filtering, but should not exceed 100uF.
We Can Offer EMC-Filter According To EN55011/22 Class B.
Negative Outputs:
A negative output voltage may be obtained by connecting the +OUT to circuit ground and
connecting –OUT as the negative output.
FOR MORE INFORMATION CALL:
Danube Enterprise Co., Ltd.
Tel: 886-7-3755165
Fax: 886-7-3755330
Home Page
http://www.danube.com.tw
DANUBE
E-mail: danube@ms10.hinet.net
http://www.danube.com.tw
5-5
2015/11/30
很抱歉,暂时无法提供与“PRD-2412G”相匹配的价格&库存,您可以联系我们找货
免费人工找货