NU SERIES
1W~2W UNREGULATED
FEATURES
UP TO 1W~2W UNREGULATED OUTPUT
POWER
100% BURN IN
HIGH EFFICIENCY
SMD TECHNOLOGY
LOW COST
UL 94V-0 PACKAGE MATERIAL
CUSTOM SOLUTIONS AVAILABLE
MTBF>2,000,000 HOURS
RoHS COMPLIANT
2 YEARS WARRANTY
OUTPUT SPECIFICATIONS
Voltage Set-point Accuracy
Temperature Coefficient
Ripple & Noise(20MHz BW)
1
INPUT SPECIFICATIONS
+/-2% max Input Voltage Range
Capacitor Type
100mVp-p max Protection
Fuse Recommended
Line Regulation
2
+/-1.2% max
Line Regulation
3
+/-1.5% max
Load Regulation
4
Load Regulation
5
Minimum Load
Short Circuit Protection
GENERAL SPECIFICATIONS
+/-8% max Efficiency
Humidity
Cooling
6
1000 VDC min
9
10% of Full Load Isolation Resistance
10 ohms min
Momentary Isolation Capacitance
80pF max
Switching Frequency
100KHz Typ
ENVIRONMENTAL SPECIFICATIONS
Storage Temperature
70%-79%
+/-12% max Isolation Voltage
7
>2,000,000 Hours
Weight
3g Typ
MTBF
Operating Temperature
+/-10% max
+/-0.03%/°C Input Filter
-40 °C to +71°C Case Material
-55°C to +125°C Case Size A
95% max
B
Free-Air Convection Conducted Emissions
Radiated Emissions
Non-Conductive Plastic
13.8mm*12.8mm*9.3mm
25.4mm*12.8mm*9.3mm
EN55022 Class A
EN55022 Class A
ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD , AND 25 °C UNLESS OTHERWISE NOTED.
1
2
3
4
5
6
7
Measured with 1uF ceramic capacitor connect to the output pins.
Line Regulation is for a 1% change in input voltage.
Line Regulation is for a 1% change in input voltage when input voltage is 3V and 3.3V.
Load Regulation is for output load current change from 20% to 100%.
Load Regulation is for output load current change from 20% to 100% when input voltage is 3V and 3.3V.
For 10 seconds.
MIL-HDBK-217F@25°C, Ground Benign.
DANUBE
http://www.danube.com.tw
1
2014/04/28
SELECTION GUIDE(1)
0.25W~0.5W 1000VDC ISOLATION
INPUT
MODEL
NUMBER
OUTPUT
OUTPUT
8
INPUT
VOLTAGE VOLTAGE CURRENT CURRENT(mA) EFF ISOLATION
(VDC)
NUS-03.305A-0.25W
(VDC)
3.3
(mA)
5
50
FULL
NO
LOAD
LOAD
125
35
9
PACKAGE
(%)
(VDC)
61
1000
A
Note: Other input to output voltages may be available. Please contact factory.
SELECTION GUIDE(2)
1W 1000VDC ISOLATION
INPUT
MODEL
NUMBER
OUTPUT
OUTPUT
10
INPUT
VOLTAGE VOLTAGE CURRENT CURRENT(mA) EFF ISOLATION
(VDC)
NUS-03.303.3A
(VDC)
(mA)
FULL
NO
LOAD
LOAD
11
PACKAGE
(%)
(VDC)
3.3
3.3
303
425
45
71
1000
A
NUS-0505A
5
5
200
283
35
71
1000
A
NUS-0509A
5
9
111
257
25
78
1000
A
NUS-0512A
5
12
84
257
25
78
1000
A
NUS-0515A
5
15
67
253
28
79
1000
A
NUS-1203.3A
12
3.3
300
112
13
74
1000
A
NUS-1205A
12
5
200
112
14
74
1000
A
NUS-1209A
12
9
111
107
11
78
1000
A
NUS-1212A
12
12
84
102
10
82
1000
A
NUS-1215A
12
15
67
102
12
82
1000
A
NUS-2405A-0.75W
24
5
150
41
11
76
1000
A
NUS-2405A
24
5
200
54
11
76
1000
A
NUS-2412A
24
12
84
54
11
76
1000
A
NUS-2415A
24
15
67
54
11
76
1000
A
Note: Other input to output voltages may be available. Please contact factory.
8
NOMINAL INPUT VOLTAGE.
NOMINAL INPUT VOLTAGE, FULL LOAD.
10
NOMINAL INPUT VOLTAGE.
11
NOMINAL INPUT VOLTAGE, FULL LOAD.
9
DANUBE
http://www.danube.com.tw
2
2014/04/28
SELECTION GUIDE(3)
1.8W 1000VDC ISOLATION
INPUT
MODEL
NUMBER
OUTPUT
OUTPUT
12
INPUT
VOLTAGE VOLTAGE CURRENT CURRENT(mA) EFF ISOLATION
(VDC)
(VDC)
(mA)
FULL
NO
LOAD
LOAD
13
PACKAGE
(%)
(VDC)
NUS-0505B
5
5
360
500
70
72
1000
B
NUS-0509B
5
9
200
480
70
75
1000
B
NUS-0512B
5
12
150
467
70
77
1000
B
NUS-0515B
5
15
120
467
70
77
1000
B
NUS-1205B
12
5
360
206
40
73
1000
B
NUS-1209B
12
9
200
197
40
76
1000
B
NUS-1212B
12
12
150
192
40
78
1000
B
NUS-1215B
12
15
120
192
40
78
1000
B
Note: Other input to output voltages may be available. Please contact factory.
SELECTION GUIDE(4)
2W 1000VDC ISOLATION
14
INPUT
MODEL
NUMBER
INPUT
OUTPUT
OUTPUT
CURRENT(mA) EFF ISOLATION
VOLTAGE VOLTAGE CURRENT
(VDC)
(VDC)
(mA)
FULL
NO
LOAD
LOAD
15
PACKAGE
(%)
(VDC)
NUS-0505B2
5
5
400
520
50
77
1000
B
NUS-0509B2
5
9
222
506
50
79
1000
B
NUS-0512B2
5
12
167
500
50
80
1000
B
NUS-0515B2
5
15
133
488
50
82
1000
B
NUS-1205B2
12
5
400
214
20
78
1000
B
NUS-1209B2
12
9
222
214
20
78
1000
B
NUS-1212B2
12
12
167
200
20
83
1000
B
NUS-1215B2
12
15
133
196
20
85
1000
B
NUS-2405B2
24
5
400
107
15
78
1000
B
NUS-2409B2
24
9
222
107
15
78
1000
B
NUS-2412B2
24
12
167
104
15
80
1000
B
NUS-2415B2
24
15
133
104
15
80
1000
B
Note: Other input to output voltages may be available. Please contact factory.
12
13
14
15
NOMINAL INPUT VOLTAGE.
NOMINAL INPUT VOLTAGE, FULL LOAD.
NOMINAL INPUT VOLTAGE.
NOMINAL INPUT VOLTAGE, FULL LOAD.
DANUBE
http://www.danube.com.tw
3
2014/04/28
MECHANICAL DIMENSIONS &
RECOMMENDED FOOTPRINT DETAILS (1)
PACKAGE ”A”
7 .62(0 .3)
0.6(0.0 235)
2.54(0.1)
9.3(0.366 )
PIN
SINGLE
1
-Vin
2
+Vin
4
-Vout
5
+Vout
NOTE : All Dimensions In mm(Inches)
1. Pin Size is 0.55mx0.30mm[0.022x0.01”]
10.5(0.413 5)
13.8(0.543 )
2. Pin is Tolerance .XX= ±0.07mm
3. Tolerance .X
12.8(0.504)
or
.XX= ±0.5mm
2.54mm
Unit:mm(inch)+/-0.25(0.010)
1.54[0.06]
13.1[0.52]
14.63[0.58]
2.54mm
5
TOP VIEW
1 2
4
1.54[0.06]
2.54[0.1]
DANUBE
http://www.danube.com.tw
4
2014/04/28
MECHANICAL DIMENSIONS &
RECOMMENDED FOOTPRINT DETAILS (2)
PACKAGE ”B”
1 7.78(0.700)
0.6(0.0 235 )
2.54(0 .100)
9.3(0.3 66)
10.5 0(0.41 35)
SINGLE
1
-Vin
3
+Vin
7
+Vout
8
-Vout
NOTE : All Dimensions In mm(Inches)
1. Pin Size is 0.55x0.30mm[0.022x0.01”]
12.8 (0.504 )
25.4 (1.000 )
PIN
2. Pin is Tolerance .XX= ±0.07mm
3. Tolerance .X
or
.XX= ±0.5mm
2.54mm
Unit: mm(inch)+/-0.25(0.010)
13.1[0.52]
14.63[0.58]
2.54mm
16
14
10 9
TOP VIEW
1
7 8
1.54[0.06]
2.54[0.1]
1.54[0.06]
REFLOW SOLDERING CURVE
Remark:The curve applies only to the hot air reflow soldering.
DANUBE
http://www.danube.com.tw
5
2014/04/28
SIMPLIFIED SCHEMATIC
TYPICAL APPLICATIONS
INPUT
+Vin
OUTPUT
+Vin
+Vout
+Vout
OSCILLATOR
DRIVER
LOAD
DC-DC
CONVERTER
-Vout
-Vin
-Vin
DERATING CURVES
-Vout
EFFICIENCY VS LOAD
EFFICIENCY(%)
% OF RATED
LOAD(%)
125%
100%
75%
SAFE
50%
OPERATING
25%
AREA
0%
-40 -20 0
80.0
60.0
40.0
20.0
0.0
30 70 100 120
0
20
40
60
80
100
% OF RATED LOAD(%)
TA(degree C)
INPUT FUSE SELECTION GUIDE(1)
1W 1000VDC ISOLATION
4.5-5.5V
10.8-13.2V
21.6-26.4V
INPUT VOLTAGE(VDC)
INPUT VOLTAGE(VDC)
INPUT VOLTAGE(VDC)
750mA Slow-Blow Type
300mA Slow-Blow Type
INPUT
150mA Slow-Blow Type
OUTPUT
Fuse
+Vin
+Vout
DC-DC
CONVERTER
-Vin
-Vout
Note: Certain applications may require the installation of external fuse in front of the input.
INPUT FUSE SELECTION GUIDE(2)
1.8W~2W 1000VDC ISOLATION
4.5-5.5V
10.8-13.2V
21.6-26.4V
INPUT VOLTAGE(VDC)
INPUT VOLTAGE(VDC)
INPUT VOLTAGE(VDC)
1500mA Slow-Blow Type
600mA Slow-Blow Type
INPUT
300mA Slow-Blow Type
OUTPUT
Fuse
+Vin
+Vout
DC-DC
CONVERTER
-Vin
-Vout
Note: Certain applications may require the installation of external fuse in front of the input.
DANUBE
http://www.danube.com.tw
6
2014/04/28
NU SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS:
Output filtering is required for operation. A minimum of 10uF is needed. Output capacitance may be
increased for additional filtering, not to exceed 220uF.
To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm
from DC to 250KHz is required.
We Can Offer EMC-Filter According To EN55011/22 Class B.
Negative Outputs:
A negative output voltage may be obtained by connecting the +OUT to circuit ground and
connecting –OUT as the negative output.
FOR MORE INFORMATION CALL:
Danube Enterprise Co., Ltd.
Tel: 886-7-3755165
Fax: 886-7-3755330
Home Page
http://www.danube.com.tw
DANUBE
E-mail: danube@ms10.hinet.net
http://www.danube.com.tw
7
2014/04/28
很抱歉,暂时无法提供与“NUS-2405A”相匹配的价格&库存,您可以联系我们找货
免费人工找货