1000 Eaton Boulevard
Cleveland, OH 44122
United States
14.4kW 208V 3PH Switched PDU - LX Interface,
Gigabit, 18 Outlets, Hubbell 50A CS8365C Input,
Outlet Monitoring, LCD, 1.8 m Cord, 0U 1.8 m
Height, TAA
Highlights
●
6 C13 and 12 C19 208V outlets
distribute AC power to
connected equipment
●
Pre-installed GbE-capable
WEBCARDLX with latest
version of PADM20 for IP-based
Auto Probe feature
●
Remote power monitoring and
control reduces on-site visits
and maintenance costs
●
1.8 m power cord with Hubbell
50A CS8365C (3P+E) 3-phase
input connects to AC power
source
●
Color touchscreen LCD provides
current levels, environmental
data and network info
MODEL NUMBER: PDU3EVSR6H50A
Applications
●
Power mission-critical rack
equipment in a data center,
computer room or high-density
network closet
●
Monitor power loads from
various computers, switches,
servers and other networking
equipment
●
Maintain a computer network in
a government, commercial or
industrial facility
●
Manage multiple rack devices
by rebooting or shutting down
individual outlets as needed
3-phase switched PDU distributes, monitors and manages power in a medium/large data center or
network installation.
Features
3-Phase PDU Distributes, Monitors and Manages Network-Grade PowerRecommended for data
centers, server rooms and high-density network closets, this switched PDU provides advanced network
control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each
outlet. You can more efficiently manage network power consumption and remotely reboot locked network
items without having to visit the site. Reducing the number of on-site visits can help lower the cost of data
center maintenance, thus lowering the 0U PDU's total cost of ownership.
18 Outlets Dispense AC Power to Connected EquipmentDuring normal operation, 18 individually
controllable outlets—six C13 and 12 C19—in six separately breakered load banks distribute AC power to
rack equipment. Each 208V outlet is accompanied by an LED that illuminates when the outlet is ramped
up and ready to be used. The outlets and banks can be individually monitored to ensure proper load
balance and prevent downtime. Plug-lock insert sleeves are included to prevent connected cables from
becoming accidentally dislodged.
Built-In GbE-Capable Network Management Card Allows Remote Access 24/7The built-in
WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides
enhanced remote management capabilities, including customizable dashboard graphs to fit user
preferences. The PADM20 upgrade and PowerAlert Element Manager (PAEM) software form a powerful
tool for expanding maintenance functions in large installations, including firmware update checks and
backup and restoration of device configurations. PADM20’s Auto Probe feature allows a PDU with
switched loads to automatically reboot devices if a network communication failure is detected. This
preserves uptime and minimizes the time and expense associated with on-site support.
Color Touchscreen LCD Offers Important Data at a GlanceAn easy-to-navigate color touchscreen LCD
reports network data, input current level per phase, and output current per load bank and per outlet with
±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 3-phase
PDU via mobile device. If an EnviroSense2 module is connected to the PDU, the LCD also displays its
status and environmental data, such as temperature and humidity.
1/4
Package Includes
●
PDU3EVSR6H50A 14.4kW 3Phase Switched PDU
●
Built-in LX Platform interface
●
Configuration cable
●
(18) Plug-lock insert sleeves
●
Rack-mounting hardware
●
Spare mounting buttons
●
PDUMVROTATEBRKT
mounting bracket accessory
●
Owner’s manual
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Easy to Install Vertically in an EIA-Standard 19 in. RackThe 70-inch 0U PDU mounts vertically using
the pre-installed toolless mounting buttons or the included brackets. Spare buttons are also included. Use
the included PDUMVROTATEBRKT kit to install the Hubbell PDU with outlets facing the rear for better
airflow or equipment access. A 6-ft. (1.83 m) cord with Hubbell 50A CS8365C (3P+E) 3-phase input
connects the switched PDU to a compatible AC power source, generator or protected UPS.
TAA-Compliant for GSA Schedule PurchasesThe PDU3EVSR6H50A is compliant with the Federal
Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule
and other federal procurement contracts.
2-Year WarrantyThe PDU3EVSR6H50A is backed by a 2-year warranty, ensuring reliability and
performance.
Specifications
OVERVIEW
UPC Code
037332206763
PDU Type
Switched
INPUT
Input Phase
3-Phase
PDU Input Voltage
208
Recommended Electrical Service
Three-phase 50A 208V service
Maximum Input Amps
40
Maximum Input Amps Details
Agency de-rated to 40A continuous
PDU Plug Type
HUBBELL CS8365C 50A
Input Cord Details
6GA (SOOW)
Input Cord Length (ft.)
6
Input Cord Length (m)
1.83
OUTPUT
Output Capacity Details
14.4kW (208V) total capacity; 20A max per breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet
Frequency Compatibility
50 / 60 Hz
Output Receptacles
(6) C13; (12) C19
Output Nominal Voltage
208V
Overload Protection
Six 20A circuit breakers, 1 per outlet bank
Customized Load Management
Receptacles
Each outlet is individually controllable via remote interface
USER INTERFACE, ALERTS & CONTROLS
Reported Load Segments
Supports monitoring of current per input phase (L1, L2, L3), output current per load bank (Banks 1-6) and per output
receptacle (1-18); Outlets are color-coded and labeled for phase and load bank identification; L1-L2 powers black
outlets (Banks 1&4); L2-L3 powers dark-gray outlets (Banks 2&5); L3-L1 powers light-gray outlets (Banks 3&6)
2/4
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Front Panel LCD Display
Touchscreen LCD reports NETWORK DATA (IP address, Subnet Mask, Gateway, MAC Address, Device Name,
Model, Serial Number), INPUT PHASE DATA (Amperage, Wattage, Voltage per phase, plus Unbalance
percentage), LOAD BANK DATA (Amperage, Wattage, Voltage per load bank, plus total PDU output in watts),
CONFIGURATION DATA (Listing of current configuration settings), ENVIRONMENTAL DATA (Reports data and
status of E2 sensor modules; Sensor options are available for temperature and humidity, plus input and output dry
contacts), MOBILE ACCESS (Generates a unique QR code to view reported PDU details on a mobile device)
Front Panel LEDs
One LED for each output receptacle offers power availability information: GREEN (Power ON), YELLOW (Warning
condition), RED (Critical condition). Network Activity (Green): Flashes for network activity. Link/Network Speed
(Yellow): On steady for any speed.
Switches
LX Platform Interface: Recessed reset switch for interface reboot and factory reset
Current Measurement Accuracy
(Amps)
+/-1%
Voltage Measurement Accuracy
(Volts)
+/-1%
Power Measurement Accuracy
(Watts)
+/-1%
SURGE / NOISE SUPPRESSION
Automatic Shut-Off
No
PHYSICAL
Material of Construction
Metal
Form Factors Supported
Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in buttonmount compatible racks
PDU Form Factor
Vertical (0U)
Shipping Dimensions (hwd / in.)
7.09 x 9.65 x 75.87
Shipping Weight (kg)
12.51
Unit Dimension Details
Chassis dimensions shown; See submittal drawing for further detail
Unit Dimensions (hwd / in.)
70.000 x 2.170 x 2.490
Unit Dimensions (hwd / cm)
177.8 x 5.5 x 5.406
Unit Weight (lbs.)
20.57
Unit Weight (kg)
9.33
ENVIRONMENTAL
Operating Temperature Range
32° to 104°F (0° to 40°C)
Storage Temperature Range
-22° to 122°F (-30° to 50°C)
Relative Humidity
5% to 95% non-condensing
Operating Elevation (ft.)
0-10,000
Operating Elevation (m)
0-3000
COMMUNICATIONS
PowerAlert Software
LX Platform Interface: PowerAlert Device Manager
Communications Cable
USB B-to-USB A Configuration/Console Access cable
3/4
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Network Monitoring Port
RJ45 Network port, RJ45 Config/Console Access port; 2x USB A ports supports a variety of Envirosense2
environmental and control modules. See Accessories>Management Hardware section for more information about
these modules. USB B port (Configuration & Console Access)
SNMP Compatibility
SNMP V1, V2c, V3
Network Compatibility
10 Mbps; 100 Mbps (Fast Ethernet); 1 Gbps (Gigabit)
Communications Interface
Pre-installed network card; RS-232; USB
FEATURES & SPECIFICATIONS
High Availability PDU Features
Auto Probe Monitoring and Reboot (included); Auto Load Shedding
STANDARDS & COMPLIANCE
Product Certifications
CAN/CSA-C22.2 No. 60950-1 (Canada); NOM (Mexico); UL 60950-1
Product Compliance
RoHS; FCC Part 15 Class A (USA); Trade Agreements Act (TAA)
WARRANTY & SUPPORT
Product Warranty Period
(Worldwide)
2-year limited warranty
© 2023 Eaton. All Rights Reserved.
Eaton is a registered trademark. All other trademarks
are the property of their respective owners.
4/4