1000 Eaton Boulevard
Cleveland, OH 44122
United States
SmartPro 750VA 600W 120V Line-Interactive Sine
Wave UPS - 6 Outlets, Extended Run,
WEBCARDLXE, LCD, USB, DB9, 2U Rack/Tower
MODEL NUMBER: SMART750RMXL2UN
Highlights
●
Protects equipment against
blackouts, brownouts,
overvoltages, surges and line
noise
●
Keeps AC power running during
blackouts to allow time for file
saves and safe shutdown
●
Maintains continuous 120V
nominal output during
brownouts and overvoltages
●
Pre-installed WEBCARDLX
network interface supports Auto
Probe feature
●
Easy-to-read LCD allows realtime monitoring of voltage,
battery status and other data
Applications
●
Protect your small network
server and other network
components against power
surges, line noise, brownouts,
overvoltages and blackouts
Line-interactive UPS offers complete power protection for small network applications, including telecom,
security and digital signage.
●
Operate essential equipment
during short-term power outages
using battery backup power
Features
●
Shut down desktop PCs and
other equipment without data
loss during long-term power
outages
●
Connect high-end security
systems, casino gaming
machines or digital signage in a
small network
750VA/750W/120V Battery Backup for Distributed IT, Telecom or Enterprise Deployments
The series SmartPro rack-mount line-interactive UPS system provides reliable battery backup and AC
power protection against blackouts, brownouts, surges and line noise that can damage your valuable IT
equipment or destroy data. The SMART750RMXL2U is ideal power management for high-end in-rack
networking equipment, including servers, VoIP phones, data storage and PoE switches. Unity power
factor ensures the most watts possible at each power rating, so you can connect more
equipment.Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power
failures and give you enough time to safely save files and shut down your system in case of a prolonged
blackout. Switchover from line to battery power happens within milliseconds to maintain continuous
operation of connected equipment without interruption or rebooting. Extra runtime is available by
connecting up to four optional extended battery modules (BP48VRM2U, sold separately).Pre-Installed LX
Platform Network Management Card Allows Remote Access 24/7
The WEBCARDLXE network interface enables full remote configuration and management, including load
shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature
ensures continuous network uptime by communicating with other network devices, detecting lost
connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO
and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control
options.NEMA 5-15R Outlets Protect Your Connected Components
Eight managed 5-15R outlets provide connected equipment with pure sine wave AC output and allow you
to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to
protect connected equipment against damaging surges and line noise. Four outlets are grouped into two
programmable load banks that let you shed non-critical loads to extend runtime for critical loads. Front
and rear cooling fans help protect equipment from overheating.Automatic Voltage Regulation (AVR)
Corrects Low- and High-Voltage Conditions
AVR protects your equipment from incremental hardware damage, data loss and performance problems
caused by brownouts. The SMART750RMXL2UN maintains regulated 120V nominal output during
brownouts and overvoltages from 80V to 151V while keeping the battery fully charged and ready to take
over in case of power failure.Premium Protection from EMI/RFI Line Noise Helps Your Equipment
Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict
hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform
1/6
Package Includes
●
SMART750RMXL2UN 120V
750VA 750W Line-Interactive
UPS
●
WEBCARDLXE network
management card
●
USB cable
●
DB9 cable
●
Rack-mounting kit
●
Tower stand support kit
●
Safety Card
●
Advanced Owner's Manual
1000 Eaton Boulevard
Cleveland, OH 44122
United States
better and last longer.ENERGY STAR-Certified to Help You Save Money and Protect the
Environment
By meeting strict U.S. Department of Energy and U.S. Environmental Protection Agency requirements,
this ENERGY STAR 2.0 UPS system provides high operational efficiency to signal a reduction in BTU
emissions, save on utility and cooling costs and help protect the environment.Intuitive Front-Panel
Interface for Convenient UPS Operation and Monitoring
The two-line front-panel LCD monitoring screen features 10 selectable screens that allow quick access to
a wide range of detailed UPS and site power information. LEDs show UPS status: a green light means
utility power is on, an orange light means the UPS is in battery mode and a red light indicates an active
alarm or fault. The control panel rotates to accommodate both rack-mount and tower
configurations.Advanced Communications Ports Allow for Automatic Saves and Shutdowns
RS-232 and USB ports connect to a device for a variety of communication options (cables are included). A
dry-contact relay port can be programmed through the LCD to provide reliable communications to
automation and industrial components. The RPO/ROO port permits emergency shutdown or remote
restart of all connected equipment.Versatile Installation Options
You can mount the SMART750RMXL2UN in just 2U of space in an EIA-standard 19-inch rack using the
included hardware. You can also adapt it for tower installation using the included support stands. The 6foot power cord with NEMA 5-15P plug connects to a compatible AC outlet.
Specifications
OVERVIEW
UPC Code
037332256409
UPS Type
Line-Interactive
INPUT
Input Phase
Single-Phase
Rated input current (Maximum Load)
12A
Nominal Input Voltage(s) Supported
120V AC
UPS Input Connection Type
5-15P
UPS Input Cord Length (ft.)
6
UPS Input Cord Length (m)
1.8
Recommended Electrical Service
15A 120V
OUTPUT
Output Capacity (VA)
750
Output Capacity (kVA)
0.75
Output Capacity (Watts)
750
Output Capacity (kW)
0.75
Power Factor
1
Nominal Voltage Details
120v nominal output in battery mode
Frequency Compatibility
50 / 60 Hz
Output Voltage Regulation (Line
Mode)
-10% ,6%
2/6
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Output Voltage Regulation (Battery
Mode)
+/- 5%
Load Management Receptacles
Two switchable two-outlet 5-15R load banks
Output AC Waveform (AC Mode)
Sine wave
Output AC Waveform (Battery
Mode)
Pure Sine wave
Nominal Output Voltage(s)
Supported
100V; 110V; 120V; 125V
Output Receptacles
(8) 5-15R
Individually Controllable Load Banks
Yes
BATTERY
Battery Type
Valve Regulated Lead Acid (VRLA)
Runtime Full Load (min.)
9 min. (750W)
Runtime Half Load (min.)
23 min. (375W)
Expandable Runtime
Yes
External Battery Pack Compatibility
BP48VRM2U (limit 4)
DC System Voltage (VDC)
48
Battery Recharge Rate (Included
Batteries)
Less than 4.5 hours from 10% to 90% (typical, full load discharge)
Battery Access
Front panel battery access door
Internal UPS Replacement Battery
Cartridge
744-A3296
Battery Replacement Description
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 80 to 151
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display
Front panel rotatable LCD information and configuration screen offers detailed UPS and site power status and
operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional
options (see manual for detailed LCD configuration and monitoring options)
Switches
5 pushbutton switches control OFF / ON power status, ENTER, UP, and DOWN selection and ESC control
functions. LX Platform Interface: Recessed reset switch for interface reboot and factory reset
Alarm Cancel Operation
Press the ESC (Escape) button on the front panel display to silence the alarm. Check the alarm condition and
perform the applicable action to resolve the condition. If the alarm status changes, the alarm beeps again, overriding
the previous alarm silencing.
Audible Alarm
Press the ESC (Escape) button on the front panel display to silence the alarm. Check the alarm condition and
perform the applicable action to resolve the condition. If the alarm status changes, the alarm beeps again, overriding
the previous alarm silencing.
LED Indicators
UPS Mode On (Solid Green); Battery Mode (Solid Orange)/ Battery Below Warning Level (Flashing Orange);
Fault/Alarm (Solid Red). Network Link/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10
Mbps (Flashing), 100 Mbps (On steady). LX Platform Interface Status: Normal Operation (Solid Green); Software
Update (Alternating Green/Orange ~1/sec); Factory Reset (Alternating Green/Orange ~2/sec).
3/6
1000 Eaton Boulevard
Cleveland, OH 44122
United States
SURGE / NOISE SUPPRESSION
EMI / RFI AC Noise Suppression
Yes
PHYSICAL
Primary Form Factor
Rackmount; Tower
Rack Height
2U
Cooling Method
Fan
Included Mounting Accessory
Description
Included mounting bracket enables installation in 4 post racks. Two ABS mounting stands enables the UPS to be
configured in an upright tower orientation.
Installation Form Factors Supported
with Included Accessories
4 post 19 inch rackmount; Tower
Installation Form Factors Supported
with Optional Accessories
2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail
rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 29USTAND ); Wallmount ( 2POSTRMKITWM )
Minimum Required Rack Depth (cm)
50.80
Minimum Required Rack Depth
(inches)
20
Optional Mounting Accessory Notes
Optional 2POSTRMKITWM enables wall-mount
installation; 4POSTRAILKITWM enables installation in 4-post
short-depth racks from 14.5 to 23.5 inches (368 to 597mm)
Primary UPS Depth (mm)
447
Primary UPS Height (mm)
86
Primary UPS Width (mm)
437
Shipping Dimensions (hwd / in.)
9.45 x 19.61 x 23.03
Shipping Weight (kg)
25.20
UPS Housing Material
Steel
UPS Power Module Dimensions
(hwd, in.)
3.4 x 17.2 x 17.6
UPS Power Module Weight (kg)
20.18
UPS Power Module Weight (lbs.)
44.5
Unit Dimensions (hwd / in.)
3.400 x 17.200 x 17.600
Unit Weight (lbs.)
44.500
Unit Weight (kg)
20.18
ENVIRONMENTAL
Operating Temperature Range
32° to 104°F (0° to 40°C)
4/6
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Storage Temperature Range
5° to 122°F (-15° to 50°C)
Relative Humidity
20 to 95%, non-condensing
AC Mode Efficiency Rating (100%
Load)
96%
Audible Noise
40 dBA maximum, front side 1m
COMMUNICATIONS
Network Management Cards
WEBCARDLXE
Network Monitoring Port Description
Pre-installed WEBCARDLXE network management card; Supports detailed monitoring of UPS and site power
conditions
PowerAlert Software
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Office software at
https://tripplite.eaton.com/products/power-alert
Communications Cable
USB, Micro-USB, and DB9 cabling included
Network Management Card
Description
Network management card included
Communications Interface
Contact closure; DB9 Serial; EPO (emergency power off); Micro-USB; Pre-installed network card; USB (HID
enabled); USB-A
Emergency Power Off
(EPO)/Remote On-Off (ROO)
Yes
LINE / BATTERY TRANSFER
Transfer Time
1-4ms for normal mode, >5ms for sensitive mode
Low Voltage Transfer to Battery
Power (Setpoint)
80
High Voltage Transfer to Battery
Power (Setpoint)
151
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode
During a Power Failure)
Cold-start operation supported
High Availability UPS Features
Auto Probe Monitoring and Reboot (included); Automatic Voltage Regulation (AVR); Hot swappable batteries;
Remote management; Surge/noise protection
Grounding Details
Back panel grounding lug
APPLICATIONS
UPS Applications
Large Network; High-End Desktop/Small Network
STANDARDS & COMPLIANCE
Product Certifications
CSA (Canada); CAN/CSA-C22.2 No. 107.3 (Canada); NOM (Mexico); UL 1778
Product Compliance
CE (Europe); ENERGY STAR Qualified; FCC Part 15 Class A (USA); RoHS
WARRANTY & SUPPORT
5/6
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Product Warranty Period
(Worldwide)
2-year warranty, 3 year with registration. Note: Registration is required for 3-year
warranty.
Connected Equipment Insurance
(U.S., Canada & Puerto Rico)
$250,000 Ultimate Lifetime
Insurance
© 2023 Eaton. All Rights Reserved.
Eaton is a registered trademark. All other trademarks
are the property of their respective owners.
6/6