Ex position switch
Ex EM 97 TKK-11 -60°C
Material number: 1450769
Features/Options:
• Ex zone 1 and 21
• Thermoplastic enclosure
• Cold-resistant down to -60 °C, return of TKK spring rod actuator
is restricted at temperatures < -20 °C
• High degree of protection IP 66 / IP 67 / IP 69
•
•
•
•
Design to EN 50047
Wiring compartment
Double insulated X
Actuator: Plastic spring rod TKK (insensitive to soiling)
Notes
• 1 Ex"e" cable gland M20x1.5 included in delivery
Dimensions
Technical data
Applied standards
EN 60947-5-1, EN 60079-0, EN
60079-1, EN 60079-7, EN
60079-31
Enclosure
thermoplastic, glass-fibre
reinforced, impact resistant, selfextinguishing UL 94 V-0
Cover
thermoset, glass-fibre reinforced,
impact resistant, selfextinguishing UL 94 V-0
Sealing
silicone
Tightening torque
cover screws: 0.4 … 0.45 Nm
connecting thread of cable gland:
max. 2 Nm
cap nut of cable gland: max. 5 Nm
Degree of protection
IP 66 to EN 60079-0 + IEC/EN
60529 (... -60 °C)
IP 67 to EN 60079-0 + IEC/EN
60529 (... -20 °C)
IP 67 / IP 69 to IEC/EN 60529
IP 69K to ISO 20653
Switch insert
1 x 8080/1-2
Contact material
Silver, nickel-plated
Switching system
snap action
Switching elements
1 NC/1 NO contact, type Zb
Connection
screw connection terminals
Cable cross-section
min. 0,75 mm² / AWG 18, max.
1,5 mm² / AWG 16, incl.
conductor ferrules
Cable entry
M20 x 1,5; screwing depth max. 9
mm; use only Ex approved and
certified cable glands with min.
degree of protection IP 66 and
suitable for the specified ambient
temperature range
Utilisation category
AC-15
Errors and omissions excepted.
steute Technologies
GmbH & Co. KG
Brückenstraße 91
32584 Löhne, Deutschland
Telefon +49 (0) 5731 745-0
Telefax +49 (0) 5731 745-200
info@steute.com
www.steute.com
Page: 1 / 2
Printed: 18.05.2021
Ex position switch
Ex EM 97 TKK-11 -60°C
Material number: 1450769
Technical data
Rated operating current Ie
max. 2 A or 4 A X
Rated operating voltage Ue
max. 500 VAC, max. 250 VAC for
unequal potential
Degree of pollution
3
Mechanical life
> 1 million operations
Impact energy
max. 7 J
Temperature class
T6
Ambient temperature
–60 °C … +55 °C max. 4 A, +60 °
C max. 2 A
Short-circuit protection
2 A / 4 A gG/gN fuse
Ex marking
L II 2G Ex db eb IIC T6 Gb,
L II 2D Ex tb IIIC T80 °C Db
IECEx Ex db eb IIC T6 Gb,
Ex tb IIIC T80 °C Db
Approvals
BVS 16 ATEX E 052
IECEx BVS 16.0052
fd
Ö
Weight
Contact diagram
23
11
24
12
160 g
Switching diagram
25°
0°
16°
4,5°
16°
4,5°
25°
23-24
11-12
23-24
11-12
Switching angle
Ø7
Errors and omissions excepted.
steute Technologies
GmbH & Co. KG
Brückenstraße 91
32584 Löhne, Deutschland
Telefon +49 (0) 5731 745-0
Telefax +49 (0) 5731 745-200
info@steute.com
www.steute.com
Page: 2 / 2
Printed: 18.05.2021
很抱歉,暂时无法提供与“EX EM 97 TKK-11”相匹配的价格&库存,您可以联系我们找货