GR EEN POW ER
Power Supplies
L6R18 Series
18W Wall Mount Power Supply
•
DOE Level VI Efficiency Rating
•
Universal Input: 90 ~ 264Vac, 47/63 Hz
•
Safety Approvals: UL/cUL, CE
•
Corded Output Connection
•
Lightweight & Compact
Load (A)
Model No.*
Application
Output
Connector
Output
Voltage
Peak
Voltage
Accuracy
Ripple
Noise
Line
Reg.
Load
Reg.
Min
Rated
L6R18-050
ITE
Corded Plug
+5.0V
0
2.1
—
±5%
50mVpp
± 1%
±5%
L6R18-090
ITE
Corded Plug
+9.0V
0
2.1
—
±5%
90mVpp
± 1%
± 5%
L6R18-120
ITE
Corded Plug
+12.0V
0
1.5
—
±5%
120mVpp
± 1%
± 5%
L6R18-150
ITE
Corded Plug
+15.0V
0
1.2
—
±5%
150mVpp
± 1%
± 5%
L6R18-180
ITE
Corded Plug
+18.0V
0
1.0
—
±5%
180mVpp
± 1%
± 5%
L6R18-240
ITE
Corded Plug
+24.0V
0
0.8
—
±5%
240mVpp
± 1%
± 5%
L6R18-300
ITE
Corded Plug
+30.0V
0
0.6
—
±5%
240mVpp
± 1%
± 5%
L6R18-360
ITE
Corded Plug
+36.0V
0
0.5
—
±5%
240mVpp
± 1%
± 5%
* Model No. format: L6R18-YYY, where YYY=050 to 360 representing output voltage. Output voltages from 5.0Vdc to 36Vdc are available for Level VI compliance in increments of
0.1V. Please contact Tri-Mag, LLC for the part number and specifications for your output voltage and/or specific output connector requirements and application.
•
•
•
•
•
Output voltage is verified to specification at 60% rated load condition.
Line Regulation is defined by changing ± 10% of input voltage from nominal line at rated load.
Load Regulation is defined by changing ± 40% of measured output load from 60% rated load.
The ripple and noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 10 μF electrolytic and a 0.1 μF capacitor at rated load
and nominal line.
Efficiency is measured at rated load and nominal line.
1601 N. Clancy Ct. • Visalia, CA 93291 • (559) 651-2222 • FAX (559) 651-0188 • sales@tri-mag.com • tri-mag.com
Power Supplies
L6R18 Series
Economical and dependable whether powering
stationary or portable devices.
choose from: 5.0Vdc to 36Vdc (in increments of
0.1V), to match your specific need.
This DOE Level VI compliant power supply/charger is
rated up to 19W, with plenty of voltage levels to
Call us (800-657-0853) for the part number to match
your particular need.
Specifications
Input
Input Voltage
Input Frequency
No Load Input Power
Input Current
Inrush Current
Leakage Current
Input Connection
Warranty
•
•
•
•
•
•
•
90 VAC ~ 264 Vac
47 Hz to 63 Hz
≤ 0.1W
1.2A Max.
40A Max.
0.25mA Max.
US (others available)
Output Voltage Range
Output Current Range
Minimum Load
Line Regulation
•
•
•
•
Load Regulation
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
•
•
•
•
•
5.0 ~ 36Vdc
500 - 2100mA, 19.2W Max.
No min. load required.
± 1% at rated load across input
voltage range.
± 5%
240mV p-p Max.
Auto recovery
Auto recovery
Auto recovery
•
•
•
50MΩ Min.
Level VI compliant
50,000 Hrs to MIL-HDBK-217F at +25°C
•
•
•
0°C to 40°C
5% - 95% RH, Non-Condensing
-20°C to +80°C
•
•
•
cULus: UL60950-1
CE
FCC
Output
Warranty Period
•
1 year
Dimensions
Tolerance
Size
•
•
Weight
Connectors
± 0.2mm
71.2 x 43.2 x 29.0 mm
2.80 x 1.70 x 1.14 Inches
• Approx. 125g (4.4 oz.)
• AC input, US 2-prong inlet plug
• DC output, standard 5.5mm x 2.1mm x
x 9.5mm corded dc output plug or per
customer specification.
Cord length
•
1500 ± 20 mm (59 ± .8”)
Mechanical Drawing
General
Insulation Resistance
Efficiency
MTBF
Environmental
Operating Temperature
Operating Humidity
Storage Temperature
EMC & Safety
Safety Approvals
EMC Approvals:
2017-06
1601 N. Clancy Ct. • Visalia, CA 93291 • (559) 651-2222 • FAX (559) 651-0188 • sales@tri-mag.com • tri-mag.com
很抱歉,暂时无法提供与“L6R18-090”相匹配的价格&库存,您可以联系我们找货
免费人工找货