CABLE 234 RF-0300-A-1 数据手册
°
°
Test Type
Test Standard
Methodology
Electrical
Performance
GradConn
Standard
Electrical
Performance
Specification
Implement 2-port full calibration of the device
under test (DUT) with a Vector Network
Analyser (VNA), firmly locking the SMA
connectors into both sides of the DUT.
Activate measurement function and select
response menu for all S-Parameters.
Salt Spray
Thermal
Shock
IPX7
BS EN 60068-211-1999
BS EN 60068-214-2009
IEC 60529:2013
Device under test consisting of a mounted
connector on an enclosure is placed within a
salt spray chamber. Test conditions as follows:
1) Temperature of the chamber 35°C
2) Temperature of the saturation 47°C
3) Salt Solution: 5%NaCl (by weight)
4) Volume of salt solution collected
1~2ml/h*80cm2
5) Test duration: 100 hours
Example Device Under
Test/Equipment Images
Parameters & Results from Cycle 5
(Full test reports available on requests)
Parameters
1GHz
2GHz
3GHz
Requirements
Insertion Loss
(dB)
0.385
0.392
0.478