0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
5102602

5102602

  • 厂商:

    HAPCO

  • 封装:

  • 描述:

    HOT AIR BLOWER TYPE COMPACT 230V

  • 数据手册
  • 价格&库存
5102602 数据手册
Data sheet HERZ Hot air blower COMPACT max. 6’100W Function: Configuration: Features: Power: Voltage: Hot air blowers for industrial use small dimensions great power Default: Temperature control with potentiometer (0 - 9) alternatively with external potentiometer (cable length 5 meters) or external control by controller or PLC (cable length 5 meters) The unit is equipped with a reliable heating element, the integrated device protection turns off the device when tripped and restore itself back after cooling. No reset is required. Default: Variable air volume control with potentiometer (0 - 9) alternatively with external potentiometer (cable length 5 meters) or external control by controller or PLC (cable length 5 meters) Custom design with internal thermocouple (cable length 1 or 5 meters) For devices with electronics maximum air temperature 50°C/122°F The unit is available without electronics For devices without electronics maximum air temperature 80°C/176°F Special design with internal temperature control Evaluating the fan speed via "open collector" 2,3 KW - 6,1 KW 230 / 400VAC (2Ph) Technical data Item number / Basic version Voltage Frequency Power Current Max. temperatuer Min. air quantiry Max. air quantity at 20°C Max. Temperature with full air quantity Static pressure Sound pressure levell (LpA) Intake opening Air outlet Heating element tube Dimensions (L x W x H) Weight incl. Cable Conformity mark VAC Hz kW A °C/°F l/min l/min °C/°F Pa db Ø mm Ø mm Ø mm mm kg Power curve 5102586 5102602 230 2,3 10,0 650/1202 400 940 260/500 3,1 13,5 800/1472 350 800 520/968 325x136x180 2,8 5102581 50 / 60 3,7 16,0 5102605 5102599 400 (2Ph+N) 4,7 11,8 650/1202 6,1 15,3 400 550 930 960 950 440/824 480/896 630/1166 450 73 (at 1m distance) 102,5 55 62 / 74 365x136x180 325x136x180 365x136x180 3,1 2,8 3,1 Protection class II DB Compact V20 R17 02_2021 GB.docx technical Subject to change 1 Data sheet HERZ Hot air blower COMPACT max. 6’100W 2 3 4 5 6 7 8 1. Power cable Connection diagram for 400VAC version: L1 = black - L2 = brown - N = blue 2. Heating ON- OFF (only if the fan switch (3) is ON) 3. Fan ON – OFF 4. Handle, pushed laterally (fixed with two screws) 5. Potentiometer for speed/air volume - Cable gland for control line for external control (Option) 6. Heating control potentiometer - Cable gland for control line for external control (Option) 7. Label (rear panel) 8. Heater tube 9. Intake 10. Temperature controller (optional) - Cable gland for signal line for pulse output (option) 11. 6 threaded inserts M5 for mounting the unit during installation (dimensions on the device base) 1 9 10 Control cable for external temperature control digital signal (PWM 10-24 VDC, 0.5 Hz) Control cable for external speed control: digital rpm = 15VDC, I/max = 10mA; PWM/1-10KHz/50-100% (50% = minimum amount of air) analog 5-10 VDC (5 VDC = minimum amount of air) 11 + = brown - = white Control cable with external potentiometer for temperature- or speed control: Red / brown + = green - = white Black / white Blue /green WARNING. "Must be guaranteed at analog or digital control of the speed that the minimum amount of air-flow is brought forward when the heat is on!" Signal line for external speed display: 1 pulse per turn Open collector output DB Compact V20 R17 02_2021 GB.docx + = brown - = white Compensation line with internal thermocouple type K ': technical Subject to change + = green - = white 2 Data sheet HERZ Hot air blower COMPACT max. 6’100W Available modifications: Item number Type 5005006 S01 5005005.2 S02 5005005.3 S29 5005009 S04 5005021.8 5005021.9 5005010.3 5005010.8 S05 S06 5005018 S07 5005020 5005016.1 5005016.3 5700128 5000120 S08 S09 S30 S10 5005004 S11 5005022 S18 5005034 S21 5700017 S24 5700161 S32 DB Compact V20 R17 02_2021 GB.docx Modification External heating control incl. 5 meter 2-wire control cable; PWM signal (5-24VDC, maximum cycle time 1Hz); control cable 2-wire: brown (+) white (-); cable ends are marked; External potentiometer for heating incl. 5 meter control cable; 3-wire; potentiometer is soldered to the end of the cable; incl. potentiometer knob red; The basic device for this modification is always standard with a potentiometer External potentiometer for blower speed; incl. 5 meter control cable; 3-wire; potentiometer is soldered to the end of the cable; incl. potentiometer knob blue; External control for blower speed incl. 5 meter control cable; control signal analogue: 0-10VDC; control signal digital: PWM 1-10kHz; 12-24VDC; Imax. 10mA; control cable 3-wire; green (+) white (-) brown (not used); cable ends are marked; Internal PID control of the temperature without visualization for basic units with potentiometer; Internal PID control of the temperature without visualization for basic units with potentiometer; !!! For Compact L !!! Internal thermocouple with 2 meter compensation lin with open cable ends green (+) white (-); Internal thermocouple with 2 meter compensation lin with open cable ends green (+) white (-);!!! For Compact L !!! Compact 230VAC with 3-pin connection cable with open ends; black (heating), brown (blower), blue (neutral); the double rocker switch is replaced by a double control lamp; The fan speed is fixed and cannot be adjusted from the outside; 230 VAC version Compact with internal thermocouple and digital controller; 400 VAC version Compact 230 VAC with internal thermocouple, digital controller and potential-free alarm output; Compact also has a handle on the back of the housing to hold the device with two hands; With the Compact 400VAC, the blower is separated from the heater via a separate connection; the double rocker switch is replaced by a double control lamp; Delivery standard is without connection cable; Alternatively, the device is available with a 4-pin connection cable: Terminal: N + L1 (blower 230VAC) L2 + L3 (heater 400VAC); Cable: blue (N) black (L1) brown (L2) gray (L3); Instead of the kink protection spiral, a normal cable gland is screwed inside the Compact; the cable outlet is milled out in a funnel shape to avoid a cable break; the handle is omitted; Compact with 5m control line for evaluating the fan speed; Control cable: brown (+) white (-); Signal: 1 pulse/turn; The heating output is fixed and cannot be adjusted from the outside; Please specify the desired heating output in% when ordering! Klixon receives another assembly position ref. 2 .. technical Subject to change 3 Data sheet HERZ Hot air blower COMPACT max. 6’100W Accessories DB Compact V20 R17 02_2021 GB.docx Description Item-No. Flange connection Round nozzle Ø 40mm 5107246 5107245 Angled nozzle Ø 62mm; length 120 x 112mm 5107265 Extension tube Ø 40mm; length = 200mm 5107247 Tubular nozzle 700 x 550 x 1,7mm 5107253 Wide slot nozzle 85 x 15mm 5107260 Wide slot nozzle 150 x 12mm 5107259 Wide slot nozzle 200 x 9mm Wide slot nozzle 250 x 12mm Wide slot nozzle 300 x 4mm Wide slot nozzle 500 x 4mm 5105977 5107263 5107262 5105991 Shrinking reflector 50 x 400mm; nozzle laterally mounted 5106177 Stainless steel filter for COMPACT suction side 5107248 technical Subject to change 4 Data sheet HERZ Hot air blower COMPACT max. 6’100W DB Compact V20 R17 02_2021 GB.docx technical Subject to change 5 Data sheet HERZ Hot air blower COMPACT max. 6’100W HERZ GmbH HERZ GmbH Kunststoff- & Wärmetechnologie Biberweg 1 DE – 56566 Neuwied Tel.: +49 (0)2622-8855-0 Fax: +49 (0)2622-8855-135 Fax: +49 (0)2622-8855-136 www.herz-gmbh.com info@herz-gmbh.com Kunststoff- & Wärmetechnologie Am Arenberg 26A DE – 86456 Gablingen Tel.: +49 (0)8230-85085 Fax: +49 (0)8230-85087 www.herz-gmbh.com robert.einberger@herz-gmbh.com HERZ Austria GmbH HERZ Austria GmbH Kunststoff- & Wärmetechnologie Gleinser Weg 27 AT – 6141 Schönberg / Tirol Tel.: +43 (0)5225-63113 Fax: +43 (0)5225-6311385 www.herz-austria.at herz.schoenberg@herz-gmbh.com Kunststoff- & Wärmetechnologie Johann-Galler-Str. 20 IZ – NÖ – Nord AT – 2120 Wolkersdorf i. Weinviertel Tel.: +43 (0)2245-82494-0 Fax: +43 (0)2245-82494-9 www.herz-austria.at herz.wolkersdorf@herz-gmbh.com HERZ Hungária Kft. HERZ Polska Sp.z o. o. Technologie obróbki tworzyw sztucznych Ul. Kostrzyńska 30 PL – 02-979 Warzawa Tel.: +48 (0)22-8428583 Fax: +48 (0)22-8429700 www.herz-polska.pl herz@herz-polska.pl Műanyag- es hőlégtechnika Pesti út 284 HU – 2225 Üllö Tel.: +36 (06)29-522400 Fax: +36 (06)29-522410 www.herz-hungaria.hu herz@herz-hungaria.hu HERZ Bulgaria OOD Boul. Assen Yordanov 10 BG – 1592 Sofia Tel.: +359 (0)2-9790351 www.herz-bulgaria.com office@herz-bulgaria.com © by HERZ GmbH DB Compact V20 R17 02_2021 GB.docx technical Subject to change 6
5102602 价格&库存

很抱歉,暂时无法提供与“5102602”相匹配的价格&库存,您可以联系我们找货

免费人工找货