0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
5102176

5102176

  • 厂商:

    HAPCO

  • 封装:

  • 描述:

    HEATER TYPE L62, 400-440-480V/8.

  • 数据手册
  • 价格&库存
5102176 数据手册
Data sheet HERZ Air heater type L62 to 9,0 KW Function: Air heater with external air supply by means of fan or compressed air. CAUTION !!! Device is not pressure-resistant !!! Configuration: Default: Temperature control with potentiometer (1 – 9) alternatively with external potentiometer (cable length 5 meter) or external control by control unit or SPS (cable length per meter) Device is equipped with a reliable heating element protection. The integrated device protection turns off the device when tripped, the fault must be with a "reset" reset again. Features: Special designs with internal thermocouple (cable length 1 or 5 meter) for devices with electronic equipment max. supply air temperature 50°C/122°F the unit is available without electronics (without heating element and device protection) for devices without electronic equipment max. supply air temperature 80°C/176°F (Special design up to max. 100°C/212°F) Power: Voltages: 4,3 KW - 9,0 KW 230 VAC, 400-480 VAC (2Ph), 400-480 VAC Technical Data: Item number / Basic versions Voltage Potentiometer external control without electronic 5102156 5102157 5102160 5102169 5102165 5102173 VAC 230 400 - 480 (2Ph) Frequency Hz Power KW 4,4 5,8 - 8,4 A 19,1 14,5 - 17,5 300 520 Current Max. temperature Min. air volume Weight Air intake Air outlet Heater tube Dimensions °C/°F l/min kg Ø mm Ø mm Ø mm mm (L x W x H) 5102183 5102176 5109138* 400 – 440 (2Ph) (480 (2Ph))* on request on request 5102155 5102161 5102162 5102164 5102171 5113725 5102177 5202092 5202090 5202091 230 (3PH) 5102175 5102178 5102168 5102084 5700067 on request 400 - 480 50 / 60 8,6 – 10,5 (12,4)* 21,6 – 23,9 (25,8)* 600 6,6 8,1 4,4 - 6,3 6,1 – 9,0 7,6 – 11,0 9,0 – 13,0 16,6 20,3 6,3 - 7,6 8,8 – 10,8 11,0 – 13,2 13,9 – 15,6 450 580 710 680 620 700/1292 740 2,9 38 55 62 / 74 360 x 123 x 124 Conformity mark Protection class I DB L62 V20 R18 02_2021 GB.doc Technical changes reserved 1 Data sheet HERZ Air heater type L62 to 9,0 KW Product description: Connection scheme: 6 3 2 1 L1 L2 L3 8 7 4 5 1. Cable fitting mains supply 2. Cable fitting control cable for external control 3. Potentiometer 0-9 (no Potentiometer for devices without electronic and external control) 4. Mounting on bottom of housing M 8 (screw depth 16 mm) 5. Heating element pipe (type L= 62mm; type XL = 92 mm) 6. Cover 7. Data plate 8. Air intake Ø 38mm 1. L1, N or L1, L2 L1, L2, L3 Main connection according to data plate 2. earth 3. 1 – 3 potential-free changeover contact (230VAC, 1A) - 2  1 = close - 2  3 = open 4. +/- external control signal from for example SPS or Controller (PWM 12 – 24VDC max. 5,0Hz) or NOTE: In the execution of 400-440VAC (2Ph), only the terminals L1, L2 and PE(protective earth) occupied. The L3 terminal is blocked by a jumper. For devices without electronics, the terminals + / - and 1/2/3 not available! NOTE: After activation of the heating element and / or equipment protection is indicated on the devices with electronics has a relay contact this disorder. The built-in relay, will give the following model with the terminals 1-3 (3), a potential-free changeover contact. This signal can only be a "reset" back off, that is, the device must be energized. Measures in case the heating element and protection: Unit from the mains, after 3 seconds automatically reset the electronics. Check the air supply (air flow, pressure, fan filter). Restore power supply. DB L62 V20 R18 02_2021 GB.doc Technical changes reserved 2 Data sheet HERZ Air heater type L62 to 9,0 KW Avaiable versions: Item No. Description 5102156 Air heater type L62 230 VAC 4,4 KW with potentiometer 5102157 Air heater type L62 230 VAC 4,4 KW externally controllable (PWM 12-24 VDC, 1 Hz) 5102160 Air heater type L62 230 VAC 4,4 KW without electronic 5102169 Air heater type L62 400-480 VAC 2Ph 5,8-8,4 KW with potentiometer 5102165 Air heater type L62 400-480 VAC 2Ph 5,8-8,4 KW externally controllable (PWM 12-24 VDC, 1 Hz) 5102173 Air heater type L62 400-480 VAC 2Ph 5,8-8,4 KW without electronic 5102183 Air heater type L62 400-440 VAC 2Ph 8,6-10,5 KW with potentiometer 5102176 Air heater type L62 400-480 VAC 2Ph 8,6-10,5 KW externally controllable (PWM 12-24 VDC; 1 Hz) 5109138 Air heater type L62 400-480 VAC 2Ph 8,6-12,4 KW without electronic 5102155 Air heater type L62 230 VAC 3Ph 6,6 KW without Elektronik 5102161 Air heater type L62 230 VAC 3PH 8,1 KW with potentiometer 5102162 Air heater type L62 230 VAC 3Ph 8,1 KW externally controllable (PWM 12-24 VDC, 1 Hz) 5102164 Air heater type L62 230 VAC 3Ph 8,1 KW without electronic 5102171 Air heater type L62 400-480 VAC 4,4-6,3 KW with potentiometer 5113725 Air heater type L62 400-480 VAC 4,4-6,3 KW externally controllable (PWM 12-24 VDC, 1 Hz) 5102177 Air heater type L62 400-480 VAC 4,4-6,3 KW without electronic 5202092 Air heater type L62 400-480 VAC 6,1-9,0 KW with potentiometer 5202090 Air heater type L62 400-480 VAC 6,1-9,0 KW externally controllable (PWM 12-24 VDC, 1 Hz) 5202091 Air heater type L62 400-480 VAC 6,1-9,0 KW without electronic 5102175 Air heater type L62 400-480 VAC 7,6-11,0 KW with potentiometer 5102178 Air heater type L62 400-480 VAC 7,6-11,0 KW externally controllable (PWM 12-24 VDC, 1 Hz) 5102168 Air heater type L62 400-480 VAC 7,6-11,0 KW without electronic 5102084 Air heater type L62 400-480 VAC 9-13 KW with potentiometer 5700067 Air heater type L62 400-480 VAC 9-13 KW externally controllable (PWM 12-24 VDC; 1 Hz) DB L62 V20 R18 02_2021 GB.doc Technical changes reserved 3 Data sheet HERZ Air heater type L62 to 9,0 KW Available modifications: Item number Type 5005014 S02 5005021.6 5005010.6 5005017 S05 S06 S17 5005033 S20 5005036.5 S23 DB L62 V20 R18 02_2021 GB.doc Modification The basic device for this modification is always External potentiometer for heating including 5m control line; 3 pole; Potentiometer is soldered to the end of the cable; including potentiometer knob red; standard with a potentiometer Internal PID control via internal potentiometer without digital display; Internal thermocouple including 2m compensation cable with open ends green (+) white (-); Device with 2m silicone connection cable. Open ended cables; the ends are marked; Inlet temperature max. 100°C/212°F; The device has no electronics but has a built-in solid state relay; there is a 2-pole connection terminal for connecting the control line; exclusive control cable; Device with tube adapter without protective tube; Standard is with protective tube; Technical changes reserved 4 Data sheet HERZ Air heater type L62 to 9,0 KW Accessories: Item No. Description 5107246 Flange connector, slideable 5107245 Round nozzle ø 40 mm, slideable 5107265 Angled nozzle, length 120 x 112mm 5107247 Extension tube 200 x 40 mm, slideable 5107253 Tubular nozzle 700 x 550 x 1.7 mm (L1 x L2 x W) 5107260 Wide slot nozzle 85 x 15mm 5107259 Wide slot nozzle 150 x 12mm 5105977 Wide slot nozzle 200 x 9mm 5107263 Wide slot nozzle 250 x 12mm 5107262 Wide slot nozzle 300 x 4mm 5105991 Wide slot nozzle 500 x 4mm 5106177 Shrinking reflector 50 x 400mm; socket mounted on the side DB L62 V20 R18 02_2021 GB.doc Technical changes reserved 5 Data sheet HERZ Air heater type L62 to 9,0 KW Combination possibilities for devices WITH electronic *: Measuring point: Hose length: Air supply: Air flow: 3.0 mm after the air outlet pipe adapter – without nozzle, measured at the hottest point 1,0 mr Blower 400 Volt, 50 Hz (HD = High pressure blower, MD = Medium pressure blower) Nl / min = standard liters per minute according to DIN 1343 CAUTION: Air flow and temperature are indicative which can change due to external influences and changes air hose diameter and length! Blower type HD140 HD240 MD10 MD14 HD140 HD240 MD10 MD14 HD140 HD240 DB L62 V20 R18 02_2021 GB.doc Quantity, air heater type; voltage; power 1 x L62; 400VAC(2Ph); 5,8KW 2 x L62; 400VAC(2Ph); 5,8KW 4 x L62; 400VAC(2Ph); 5,8KW 6 x L62; 400VAC(2Ph); 5,8KW 1 x L62; 400VAC(2Ph); 5,8KW 2 x L62; 400VAC(2Ph); 5,8KW 4 x L62; 400VAC(2Ph); 5,8KW 1 x L62; 400VAC(2Ph); 5,8KW 2 x L62; 400VAC(2Ph); 5,8KW 4 x L62; 400VAC(2Ph); 5,8KW 1 x L62; 400VAC(2Ph); 8,6KW 2 x L62; 400VAC(2Ph); 8,6KW 4 x L62; 400VAC(2Ph); 8,6KW 1 x L62; 400VAC(2Ph); 8,6KW 2 x L62; 400VAC(2Ph); 8,6KW 4 x L62; 400VAC(2Ph); 8,6KW 1 x L62; 400VAC(2Ph); 8,6KW 2 x L62; 400VAC(2Ph); 8,6KW 4 x L62; 400VAC(2Ph); 8,6KW 1 x L62; 400VAC; 7,6KW 2 x L62; 400VAC; 7,6KW 4 x L62; 400VAC; 7,6KW Air flow at 50 Hz with heating [Nl / min.] 1300 2 x 730 4 x 1000 6 x 700 720 2 x 640 4 x 590 860 2 x 770 4 x 750 1370 2 x 750 4 x 1020 840 2 x 800 4 x 660 1000 2 x 960 4 x 840 1320 2 x 750 4 x 1000 Technical changes reserved Maximum temperature at 50 Hz [°C/°F] 340/644 530/986 410/770 550/1022 570/1058 580/1076 600/1112 490/914 500/932 500/932 380/716 600/1112 480/896 570/1058 570/1058 620/1148 500/932 500/932 530/986 450/842 690/1274 550/1022 6 Data sheet HERZ Air heater type L62 to 9,0 KW Combination possibilities for devices WITH electronic *: Measuring point: Hose length: Air supply: Air flow: 3.0 mm after the air outlet pipe adapter – without nozzle, measured at the hottest point 1,0 mr Blower 400 Volt, 50 Hz (HD = High pressure blower, MD = Medium pressure blower) Nl / min = standard liters per minute according to DIN 1343 CAUTION: Air flow and temperature are indicative which can change due to external influences and changes air hose diameter and length! Blower type MD10 MD14 HD140 HD240 MD10 MD14 Quantity, air heater type; voltage; power 1 x L62; 400VAC; 7,6KW 1 x L62; 400VAC; 7,6KW 2 x L62; 400VAC; 7,6KW 4 x L62; 400VAC; 7,6KW 1 x L62; 400VAC; 4,4KW 2 x L62; 400VAC; 4,4KW 4 x L62; 400VAC; 4,4KW 1 x L62; 400VAC; 4,4KW 1 x L62; 400VAC; 4,4KW 2 x L62; 400VAC; 4,4KW 4 x L62; 400VAC; 4,4KW Air flow at 50 Hz with heating [Nl / min.] 660 790 2 x 750 4 x 690 1380 2 x 750 4 x 1010 830 990 2 x 960 4 x 810 Maximum temperature at 50 Hz [°C/°F] 660/1220 630/1166 660/1220 680/1256 280/536 440/824 350/662 420/788 370/698 370/698 410/770 *Data without guarantee DB L62 V20 R18 02_2021 GB.doc Technical changes reserved 7 Data sheet HERZ Air heater type L62 to 9,0 KW DB L62 V20 R18 02_2021 GB.doc Technical changes reserved 8 Data sheet HERZ Air heater type L62 to 9,0 KW HERZ GmbH HERZ GmbH Kunststoff- & Wärmetechnologie Biberweg 1 DE – 56566 Neuwied Tel.: +49 (0)2622-8855-0 Fax: +49 (0)2622-8855-135 Fax: +49 (0)2622-8855-136 www.herz-gmbh.com info@herz-gmbh.com Kunststoff- & Wärmetechnologie Am Arenberg 26A DE – 86456 Gablingen Tel.: +49 (0)8230-85085 Fax: +49 (0)8230-85087 www.herz-gmbh.com robert.einberger@herz-gmbh.com HERZ Austria GmbH HERZ Austria GmbH Kunststoff- & Wärmetechnologie Gleinser Weg 27 AT – 6141 Schönberg / Tirol Tel.: +43 (0)5225-63113 Fax: +43 (0)5225-6311385 www.herz-austria.at herz.schoenberg@herz-gmbh.com Kunststoff- & Wärmetechnologie Johann-Galler-Str. 20 IZ – NÖ – Nord AT – 2120 Wolkersdorf i. Weinviertel Tel.: +43 (0)2245-82494-0 Fax: +43 (0)2245-82494-9 www.herz-austria.at herz.wolkersdorf@herz-gmbh.com HERZ Hungária Kft. HERZ Polska Sp.z o. o. Technologie obróbki tworzyw sztucznych Ul. Kostrzyńska 30 PL – 02-979 Warzawa Tel.: +48 (0)22-8428583 Fax: +48 (0)22-8429700 www.herz-polska.pl herz@herz-polska.pl Műanyag- es hőlégtechnika Pesti út 284 HU – 2225 Üllö Tel.: +36 (06)29-522400 Fax: +36 (06)29-522410 www.herz-hungaria.hu herz@herz-hungaria.hu HERZ Bulgaria OOD Boul. Assen Yordanov 10 BG – 1592 Sofia Tel.: +359 (0)2-9790351 www.herz-bulgaria.com office@herz-bulgaria.com © by HERZ GmbH DB L62 V20 R18 02_2021 GB.doc Technical changes reserved 9
5102176 价格&库存

很抱歉,暂时无法提供与“5102176”相匹配的价格&库存,您可以联系我们找货

免费人工找货