Data sheet
HERZ
Air heater type S36 from 1,8 to 3,3 KW
Air heater with external air supply by means of fan or compressed air.
CAUTION !!! Device is not pressure-resistant !!!
Function:
Configuration: Default: Temperature control with potentiometer (1 – 8)
- alternatively with external potentiometer (cable length 5 meter) or
- external control by control unit or SPS (cable length 5 meter)
The device is equipped with a reliable heating element protection. The integrated device
protection turns off the device when tripped and resets automatically after cooling down. A
reset is not required.
Special design with internal thermocouple (cable length 1 or 5 meter):
- for devices with electronic equipment max. supply air temperature 50°C122°F
- the unit is available without electronics (without heating element protection)
- for devices without electronic equipment max. supply air temperature
80°C/176°F
Features:
Power:
Voltage:
1,8 KW - 3,3 KW
120VAC, 230 VAC
Technical data:
Item number / Basic versions
Voltage
Frequency
Power
Current
Max. temperature
Min. air volume
Weight
Air intake
Air outlet
Heater tube
Dimensions
Potentiometer
external control
without electronic
VAC
Hz
KW
A
°C/°F
l/min
kg
Ø mm
Ø mm
Ø mm
mm (L x W x H)
5700122
on request
on request
5101436
on request
on request
5101428
5101429
5101410
120
1,8
15,0
5101426
5101382
5101434
230
50 / 60
2,2
18,3
2,3
10,0
14,3
on request
on request
5101440
400 (2Ph)
on request
on request
5101439
480 (2Ph)
3,3
8,3
6,9
650/1202
230
280
420
0,47
19
22
36 / 43
241 x 70 x 59
Conformity mark
Protection class II
DB S36 V20 R18 02_2021 GB.docx
Technical changes reserved
1
Data sheet
HERZ
Air heater type S36 from 1,8 to 3,3 KW
Product description:
Connection scheme:
6
Default with
potentiometer
External control
N, L1 =
Main connection
according to data plate
N, L1 =
Main connection
according to data plate
5
7
1
2
3
+/control cable
4
1. Cable fitting mains supply
2. Potentiometer 0-8 (control cable for ext. control);
(no Potentiometer for devices without electronic)
3. Mounting on bottom of housing M 4
(screw depth 7 mm)
4. Heating element pipe Ø36mm
5. Cover
6. Data plate
7. Air intake Ø19mm
DB S36 V20 R18 02_2021 GB.docx
Digital signal
(PWM max. 0,5Hz)
10-24VDC
+ = brown
- = white
Version without
electronics
N, L1 =
Main connection
according to data plate
Technical changes reserved
2
Data sheet
HERZ
Air heater type S36 from 1,8 to 3,3 KW
Avaiable Versions:
Item no.
5700122
5101436
5101428
5101429
5101410
5101426
5101382
5101434
5101440
5101439
Description
Air heater type S36 120 VAC 1,8 KW with potentiometer
Air heater type S36 120 VAC 2,2 KW with potentiometer
Air heater type S36 230 VAC 2,3 KW with potentiometer
Air heater type S36 230 VAC 2,3 KW externally controllable (PWM 12-24 VDC, 1 Hz) with 5.0m control cable (2-pin)
Air heater type S36 230 VAC 2,3 KW without electronics
Air heater type S36 230 VAC 3,3 KW with potentiometer
Air heater type S36 230 VAC 3,3 KW externally controllable (PWM 12-24 VDC, 1 Hz) with 5.0m control cable (2-pin)
Air heater type S36 230 VAC 3,3 KW without electronics
Air heater type S36 400 VAC (2Ph) 3,3 KW without electronics
Air heater type S36 480 VAC (2Ph) 3,3 KW without electronics
Available modifications:
Artikelnummer
Typ
5005005.1
S02
5005021.3
5005010.3
5005007
S05
S06
S12
5005019
S13
5005036.2
5700141
S23
S31
DB S36 V20 R18 02_2021 GB.docx
Modifikation
The basic device for this modification is
External potentiometer for heating including 5m control line; 3 pole;
always standard with a potentiometer
Potentiometer is soldered to the end of the cable; including potentiometer knob red;
Internal PID control via internal potentiometer without digital display;
Internal thermocouple including 2m compensation cable with open ends green (+) white (-);
A push-in nipple for air hose 8/6mm is mounted on the air connection
Instead of the potentiometer for devices WITHOUT electronics, a 1/4 "compressed air hose connection 6/4mm is installed;
This is used to monitor the pressure in the housing;
Device with tube adapter without protective tube; Standard is with protective tube;
100% heating output with heating element protection for type S/M (for basic device without electronics);
Technical changes reserved
3
Data sheet
HERZ
Air heater type S36 from 1,8 to 3,3 KW
Accessories:
Item no.
Description
5107250
Flange connector, push fit on the protective tube
5107155
Tubular nozzle ø 5mm
5107003
Angle nozzle 90°, ø 12mm
5107251
Extension tube 210 x 36,5mm
5107261
Wide slot nozzle 70 x 4mm
Combination possibilities for devices WITH electronic*:
Measuring point:
Hose length:
Air supply:
Air flow:
3.0 mm after the air outlet pipe adapter – without nozzle, measured at the hottest point
1,0 mr
Blower 400 Volt, 50 Hz (HD = High pressure blower, MD = Medium pressure blower)
Nl / min = standard liters per minute according to DIN 1343
CAUTION:
Air flow and temperature are indicative which can change due to external influences and changes air hose diameter and length!
Blower type
HD140
HD140
HD240
Quantity, air heater type,
voltage, power
1 x S36; 230VAC; 2,3KW
2 x S36; 230VAC; 2,3KW
4 x S36; 230VAC; 2,3KW
1 x S36; 230VAC; 3,3KW
2 x S36; 230VAC; 3,3KW
4 x S36; 230VAC; 3,3KW
Air flow at 50 Hz with heating [Nl / min.]
680
2 x 500
4 x 310
630
2 x 480
4 x 660
Maximum temperature
at 50 Hz [°C/°F]
340/644
400/752
540/104
450/842
520/968
380/716
*Data without guarantee
DB S36 V20 R18 02_2021 GB.docx
Technical changes reserved
4
Data sheet
HERZ
Air heater type S36 from 1,8 to 3,3 KW
DB S36 V20 R18 02_2021 GB.docx
Technical changes reserved
5
Data sheet
HERZ
Air heater type S36 from 1,8 to 3,3 KW
HERZ GmbH
HERZ GmbH
Kunststoff- & Wärmetechnologie
Biberweg 1
DE – 56566 Neuwied
Tel.: +49 (0)2622-8855-0
Fax: +49 (0)2622-8855-135
Fax: +49 (0)2622-8855-136
www.herz-gmbh.com
info@herz-gmbh.com
Kunststoff- & Wärmetechnologie
Am Arenberg 26A
DE – 86456 Gablingen
Tel.: +49 (0)8230-85085
Fax: +49 (0)8230-85087
www.herz-gmbh.com
robert.einberger@herz-gmbh.com
HERZ Austria GmbH
HERZ Austria GmbH
Kunststoff- & Wärmetechnologie
Gleinser Weg 27
AT – 6141 Schönberg / Tirol
Tel.: +43 (0)5225-63113
Fax: +43 (0)5225-6311385
www.herz-austria.at
herz.schoenberg@herz-gmbh.com
Kunststoff- & Wärmetechnologie
Johann-Galler-Str. 20 IZ – NÖ – Nord
AT – 2120 Wolkersdorf i. Weinviertel
Tel.: +43 (0)2245-82494-0
Fax: +43 (0)2245-82494-9
www.herz-austria.at
herz.wolkersdorf@herz-gmbh.com
HERZ Hungária Kft.
HERZ Polska Sp.z o. o.
Technologie obróbki tworzyw sztucznych
Ul. Kostrzyńska 30
PL – 02-979 Warzawa
Tel.: +48 (0)22-8428583
Fax: +48 (0)22-8429700
www.herz-polska.pl
herz@herz-polska.pl
Műanyag- es hőlégtechnika
Pesti út 284
HU – 2225 Üllö
Tel.: +36 (06)29-522400
Fax: +36 (06)29-522410
www.herz-hungaria.hu
herz@herz-hungaria.hu
HERZ Bulgaria OOD
Boul. Assen Yordanov 10
BG – 1592 Sofia
Tel.: +359 (0)2-979035
www.herz-bulgaria.com
office@herz-bulgaria.com
© by HERZ GmbH
DB S36 V20 R18 02_2021 GB.docx
Technical changes reserved
6