EB3C Relay Barriers
EB3L Lamp Barriers
EB3N Safety Relay Barriers
EB3C Relay Barriers
EB3L Lamp Barriers
EB3N
Safety Relay Barriers
Intrinsically Safe Explosion-proof System
Output
Common
wiring
Relay output
1NO
Without auxiliary
output
Transistor
output
Power Supply
Separate wiring·
Common wiring
AC
EB3C-∗∗AN
Relay barrier
Page 4
DC
EB3C-∗∗DN
Relay barrier
Page 4
Auto
reset
EB3N-A2∗DN
With auxiliary
output
Reset
Wiring condition
Wiring condition
Safety input
equipment need
to be installed.
Page 24
Manual
reset
EB3N-M2∗DN
Page 24
EB3C∗∗AN
Common
wiring
Transistor output
Source input
Sink input
Power Supply
Relay output
Input/Output
Illuminated
switch needs to
be installed.
Page 4
AC
Wiring condition
Zone 0
Zone 1
Zone 2
Relay barrier
Lamp barrier
In an hazardous area....
Contacts
need to be
installed.
Safety relay barrier
Zone 0
Zone 1
Zone 2
Relay barrier
In order to establish an intrinsically safe explosion-proof system, a barrier must be selected depending on the type of device (such as) pushbutton,
pilot light, and proximity switch that are installed in the hazardous area. See the selection chart below.
EB3L∗∗AN
Page 12
EB3C∗∗DN
DC
Page 4
EB3L∗∗DN
2
Common
wiring
LED pilot light
Buzzer (note)
Power Supply
Separate wiring·
Common wiring
Pilot Light
Buzzer
needs to be
installed.
Wiring condition
Pilot light
needs to be
installed.
Lamp barrier
Page 12
AC
EB3L-S∗AN
DC
EB3L-S∗DN
Lamp barrier
Page 12
Lamp barrier
Page 12
Relay Barrier / Lamp Barrier Selection
Relay Barrier
EB3C- AN
Model
EB3C- DN
EB3N- D
Shape
Explosion Protection
FM: Class I, II, III Div1 / Group A, B, C, D, E, F, G
Class I, Zone 0 / AEx [ia] II C
UL:
Class I, II, III Div1 / Group A, B, C, D, E, F, G
Class I, Zone 0 / AEx [ia] II C
PTB (ATEX, IECEx): [Exia] II C, Exia] III C
CQST:
[Exia Ga] II C
TIIS:
[Exia] II C
KCS:
[Exia] II C
NK:
[Exia] II C
KR:
[Exia] II C
Relay Barrier: [Exia] II C
Degree of Protection
IP20
IP20
IP20
No. of Channels
1, 2, 3, 5, 6, 8, 10, 16
1, 2, 3, 5, 6, 8, 10, 16
EB3N-£2ND:
EB3N-£2R5D:
Power Voltage
100 to 240V AC
24V DC
24V DC
Output
Relay
Transistor
(Sink/Source)
Relay
Transistor
(Sink/Source)
Relay
Connection
Screw Terminal
Screw Terminal, Connector
Screw Terminal
Mounting
35-mm-wide DIN rail
Panel mounting
35-mm-wide DIN rail
Panel mounting
35-mm-wide DIN rail / Panel mounting
Size
(excluding projections)
42W×75H×77.5D (1 channel)
65W×75H×77.5D (2, 3 channels)
110.5W×75H×77.5D (5, 6, 8 channels (common))
171.5W×75H×77.5D (8, 10, 16 channels (common))
42W×75H×77.5D (1 channel)
65W×75H×77.5D (2, 3 channels)
110.5W×75H×77.5D (5, 6, 8 channels (common))
171.5W×75H×77.5D (8, 10, 16 channels (common))
65.0W×75.0H×77.5D
(EB3N-£2ND)
110.5W×75.0H×77.5D
(EB3N-£2R5D)
Weight (approx.)
0.38kg (EB3C-R10AN)
0.39kg (EB3C-R16CDN)
220g (EB3N-£2ND)
300g (EB3N-£2R5D)
2 safety circuits
2 safety circuits,
5 auxiliary circuits
4
Page
24
Lamp Barrier
EB3L- AN
Model
EB3L- DN
Shape
Explosion Protection
FM: Class I, II, III Div1 / Group A, B, C, D, E, F, G
Class I, Zone 0 / AEx [ia] II C
UL:
Class I, II, III Div1 / Group A, B, C, D, E, F, G
Class I, Zone 0 / [AEx ia] II C
PTB (ATEX, IECEx): [Exia] II C, Exia] III C
CQST:
[Exia Ga] II C
TIIS:
[Exia] II C
KCS:
[Exia] II C
NK:
[Exia] II C
KR:
[Exia] II C
Degree of Protection
IP20
IP20
No. of Channels
1, 2, 3, 5, 6, 8, 10
1, 2, 3, 5, 6, 8, 10, 16
Power Voltage
100 to 240V AC
24V DC
Input/Output
Transistor input (sink)
Transistor input (source)
Transistor input (sink)
Transistor input (source)
Connection
Screw Terminal
Screw Terminal, Connector
Mounting
35-mm-wide DIN rail
Panel mounting
35-mm-wide DIN rail
Panel mounting
Size
(excluding projections)
42W×75H×77.5D (1 channel)
65W×75H×77.5D (2, 3 channels)
110.5W×75H×77.5D (5, 6, 8 channels (common))
171.5W×75H×77.5D (8, 10 channels)
42W×75H×77.5D (1 channel)
65W×75H×77.5D (1 channel)
110.5W×75H×77.5D (5, 6, 8 channels (common))
171.5W×75H×77.5D (8, 10, 16 channels (common))
Weight (approx.)
0.36kg (EB3L-S10SAN)
Page
0.36kg (EB3L-S16CSDN)
12
3
EB3C Relay Barriers
Input contacts can be used in any explosive gas and Zone 0/Class I Div. 1 areas.
Explosion
protection
Relay Barrier:
Switch (EB9Z-A):
Switch (EB9Z-A1):
[Exia] II C
Exia II CT6
Exia II BT6
••IEC60079 compliant.
••Wide variety of models ranging from 1-circuit to 16 circuit models.
••8- and 16-channel are available in common wiring, ideal for connection to
PLCs. 16-circuit also available with a connector.
••No grounding required.
••IDEC’s original spring-up terminal minimizes wiring time.
••35-mm-wide DIN rail mounting or direct screw mounting.
••Global usage
IECEx
USA:
FM, UL
Europe: CE marking, ATEX
China: CQST
Korea: KCS
Taiwan TS
Japan: TIIS
••Ship class: NK (Japan), KR (Korea)
Connector Model
Relay Barriers
Power
Voltage
Connection to
Non-intrinsically
Safe Circuit
Input Wiring Method
Number of
Channels
Output
Separate/Common
Wiring Compatible
Relay
Common Wiring Only
100 to 240V AC
Separate/Common
Wiring Compatible
Transistor (Sink/Source)
Transistor (Sink)
Common Wiring Only
Transistor (Source)
Screw Terminal
Separate/Common
Wiring Compatible
Relay
Common Wiring Only
24V DC
Separate/Common
Wiring Compatible
Transistor (Sink/Source)
Sink
Common Wiring Only
Connector
4
Transistor
Source
Sink
Source
1
2
3
5
6
8
10
8
1
2
3
5
6
8
10
8
16
8
16
1
2
3
5
6
8
10
8
16
1
2
3
5
6
8
10
8
16
8
16
16
Part No.
Weight (g)
EB3C-R01AN
EB3C-R02AN
EB3C-R03AN
EB3C-R05AN
EB3C-R06AN
EB3C-R08AN
EB3C-R10AN
EB3C-R08CAN
EB3C-T01AN
EB3C-T02AN
EB3C-T03AN
EB3C-T05AN
EB3C-T06AN
EB3C-T08AN
EB3C-T10AN
EB3C-T08CKAN
EB3C-T16CKAN
EB3C-T08CSAN
EB3C-T16CSAN
EB3C-R01DN
EB3C-R02DN
EB3C-R03DN
EB3C-R05DN
EB3C-R06DN
EB3C-R08DN
EB3C-R10DN
EB3C-R08CDN
EB3C-R16CDN
EB3C-T01DN
EB3C-T02DN
EB3C-T03DN
EB3C-T05DN
EB3C-T06DN
EB3C-T08DN
EB3C-T10DN
EB3C-T08CKDN
EB3C-T16CKDN
EB3C-T08CSDN
EB3C-T16CSDN
EB3C-T16CKD-CN
EB3C-T16CSD-CN
150
180
190
260
270
300
380
280
140
170
180
250
260
320
340
260
260
260
260
130
170
180
250
260
260
360
270
390
120
160
170
240
250
250
320
250
350
250
350
330
330
EB3C Relay Barrriers
Accessories
Name
Part No.
BAA1000
BAP1000
BNL6
EB9Z-N1
DIN Rail
End Clip
Static Electricity Caution Plate
Ordering No.
BAA1000PN10
BAP1000PN10
BNL6PN10
EB9Z-N1PN10
Explosion-Protection and Electrical Specifications
Explosion Protection
Degree of Protection
Installation Location
Relay Barrier
Switch
Non-intrinsically Safe Circuit
Maximum Voltage (Um)
Intrinsically Safe Circuits
Wiring Method
Rated Operating Voltage
Rated Operating Current
Maximum Output Voltage (Uo)
Maximum Output Current (lo)
Maximum Output Power (Po)
Maximum External
Capacitance (Co) (Note 1)
Maximum External
Inductance (Lo)
(Note 2)
Allowable Wiring Resistance (Rw)
Maximum Channels per
Common Line
Contact Configuration
Rated Insulation Voltage (Ui)
Thermal Current (lth)
Resistive Load
Contact
Allowable
Inductive Load
Power
Relay Output
Inductive Load
Minimum Applicable Load
Contact Resistance
Turn ON Time
Turn OFF Time
Mechanical Life
Electrical Life
Transistor Output
Non-intrinsically Safe Circuits
Resistive Load
Rated Load
Short-circuit Protection
Rated Voltage
Maximum Voltage
Maximum Current
Leakage Current
Voltage Drop
Clamping Voltage
Inrush Current
Turn ON Time
Turn OFF Time
Short-circuit Protection
Package Quantity
10
10
10
10
Certification No.
Intrinsic safety type
IP20 (IEC60529)
Safe indoor place
(safe area: non-hazardous area)
For zone 0, 1, 2 hazardous areas
Certification
Organization
250V AC
c-UL
FM
1-channel
Separate Wiring
12V DC ±10%
10 mA DC ±20%
13.2V DC
14.2 mA
46.9 mW
16-channel
Common Wiring
227.2 mA
750 mW
CQST
KCs
470 nF (470 nF)
490 nF (365 nF)
TIIS
87.5 mH (87.5 mH)
0.6 mH (0.425 mH)
300Ω
600/(N+1)Ω
(N = number of
common channels)
—
PTB (ATEX)
PTB (IECEx)
16
1NO
250V AC, 125V DC
3A (common terminal: 8A)
AC: 750 VA, DC: 72W
AC: 750 VA (cos ø = 0.3 to 0.4)
DC: 48W (L/R = 7 ms)
250V AC 3A, 24V DC 3A
250V AC 3A (cos ø = 0.3 to 0.4)
24V DC 2A (L/R = 7 ms)
0.1V DC, 0.1 mA (reference value)
50 mΩ maximum (initial value)
12 ms maximum (rated voltage)
10 ms maximum (rated voltage)
20,000,000 operations minimum
(at 18,000 operations/hour, without load)
100,000 operations minimum
(at 1,800 operations/hour, rated load)
None
24V DC
30V DC
100 mA (connector model: 15 mA)
0.1 mA maximum
1.5 V maximum
33V (1W)
0.5A maximum (1 sec)
0.1 ms maximum (resistive load)
0.4 ms (typical) (resistive load)
None
Note: Values in ( ) are those approved by TIIS (Technology Institution of Industrial Safety,
Japan).
Description
Aluminum (1m long)
Steel (1m long)
For fastening EB3C units on the DIN rail.
Polyester 20 (W) x 6 (H) mm
NK
KR
Explosion Protection
Class I, II, III Div. 1
Group A, B, C, D, E, F, G
Class I, Zone 0 AEx [ia] II C
Class I, II, III, Div. 1
Group A, B, C, D, E, F, G
Class I, Zone 0 AEx [ia] II C
[Exia] II C: Gas, Vapour
[Exia] III C: Dust
[Exia] II C: Gas, Vapour
[Exia] III C: Dust
[Exia Ga] II C
[Exia] II C
Relay barrier: [Exia] II C
Switch (EB9Z-A): Exia II CT6
Switch (EB9Z-A1): Exia II BT6
[Exia] II C
[Exia] II C
Certification No.
FM16US0364X
E234997
PTB09 ATEX2046
IECEx PTB10.0015
CNEx14.0047
14-AV4B0-0373
TC20539
TC15758
TC15961
TA18437M
TYK17821-EL003
Note: For details about switches, see “Switch Explosion-Protection Specifications” on page
6 and “3. Switches in the Hazardous Area” on page 10.
General Specifications
Power Voltage
Rated Power Voltage
Allowable Voltage Range
Rated Frequency
Inrush Current
Dielectric Strength
(1 minute, 1 mA)
Operating Temperature
Storage Temperature
Operating Humidity
Atmosphere
Pollution Degree
Insulation Resistance
Vibration Resistance
(damage limits)
Shock Resistance
(damage limits)
Terminal Style
Mounting
Power Consumption
(approx.)
AC Power
DC Power
100 to 240V AC
24V DC
–15 to +10%
±10%
50/60 Hz
—
(allowable range: 47 to 63 Hz)
10A (100V AC)
10A
20A (200V AC)
Between intrinsically safe circuit and non-intrinsically safe
circuit: 1526.4V AC
Between AC power and output terminal: 1500V AC
Between DC power and transistor output terminal:
1000V AC (screw terminal model only)
–20 to +60°C (no freezing)
–20 to +60°C (no freezing)
45 to 85% RH (no condensation)
800 to 1100 hPa
2 (IEC60664)
10 MΩ minimum (500V DC megger, between the same poles
as the dielectric strength)
Panel mounting: 10 to 55 Hz, amplitude 0.75 mm
DIN rail mounting: 10 to 55 Hz, amplitude 0.35 mm
Panel mounting: 500 m/s2 (3 times each on X, Y, Z)
DIN rail mounting: 300 m/s2 (3 times each on X, Y, Z)
M3 screw terminal
35-mm-wide DIN rail or panel mounting (M4 screw)
9.6 VA (EB3C-R10AN at 200V AC)
4.8W (EB3C-R16CDN at 24V DC)
5
EB3C Relay Barrriers
Switch Explosion-Protection Specifications (Japan only)
Simple apparatuses in accordance with relevant standards of each country can be installed in the hazardous area and connected to the EB3C located in the safe area.
In Japan, any switches, though regarded as simple apparatuses, must be certified for explosion-proof devices. EB9Z-A and EB9Z-A1 are IDEC’s generic Part No. of
any single apparatuses certified by TIIS for use with the EB3C, therefore simple apparatuses with specifications shown below can be used as those approved by the
Japanese explosion-proof certification.
Switch Part No.
Explosion Proof (Note 1)
Operating Temperature
Operating Humidity
Degree of Protection
Dielectric Strength
Intrinsic Safety Ratings and Parameters
EB9Z-A
EB9Z-A1
Exia II CT6
Exia II BT6
–20 to +60°C (no freezing)
45 to 85% RH (no condensation)
IP20
500V AC, 1 mA
1-channel Separate Wiring
16-channel Common Wiring
Maximum input voltage (Ui):
13.2V
Maximum input voltage (Ui):
13.2V
Maximum input current (Ii): 14.2 mA
Maximum input current (Ii): 227.2 mA
Maximum input power (Pi): 46.9 mW
Maximum input power (Pi): 750 mW
Internal capacitance (Ci): ≤ 2 nF
Internal capacitance (Ci): ≤ 32 nF
Internal inductance (Li): ≤ 5 µH
Internal inductance (Li): ≤ 80 µH
Metallic: Magnesium content must be 7.5% or less (steel and aluminum are acceptable)
Caution
Plastic: Switch operator exposed area
IIC: 20 cm2 maximum
IIB: 100 cm2 maximum
When the switch has a wider exposed area, attach a caution label as
shown at right.
Enclosure Material
To prevent electrostatic
charges, do not rub the
switch surface during
operation. Use a soft cloth
dipped with water for
cleaning.
Caution Label Example
Contact rating:
Ui, Ii minimum
Contact resistance:
0.5Ω maximum
Cross sectional area of wire:
0.000962 mm2 minimum
Printed circuit board:
Thickness 0.5 mm minimum
Copper foil width 0.15 mm minimum
Thickness 18 µm minimum one/both side(s)
A resistor to prevent contact welding and an LED can be connected to 1-channel separate wiring circuits.
Consult IDEC for details.
Switch Ratings (Note 2)
Note 1: See “Precautions for Operation” on page 10.
Note 2: For details, see “3. Switches in the Hazardous Area” on page 10.
Internal Circuit Block Diagram
AC Power, Relay Output
DC Power, Transistor Output
Connector Wiring, Sink Output
Hazardous Area
••••••••
P1 N1 P2 N2 P3 N3
P1 N1 P2 N2 P3 N3
Green
Yellow
Yellow
Yellow
Green
Yellow
Yellow
N
+
A1 C1 A2 C2 A3 C3
Yellow
Green
~
~
~
~
L
Yellow
P1 • • • • P16 N1
N2
Safe Area
(Non-hazardous Area)
Yellow
~
~
~
–
A1 C1 A2 C2 A3 C3
+
–
A1 • • • • A16 C1 C2
Dimensions
Connector Model
EB3C-T16C-CN
M3
ø6
Applicable Crimping Terminal
75
ø3.2 min.
6 max.
4-ø4.4 hole
65
171.5
3 max.
5.4 min.
Stripping the Wire End
Solid Wire
(4)
83.5
77.5
65
6 to 8 mm
4-M4
or
4-4.5 holes
Stranded Wire (Ferrule)
6
6 to 8 mm
10
97
6
10
97
Mounting Hole Layout
All dimensions in mm.
EB3C Relay Barrriers
EB3C-∗03N
EB3C-∗02N
110.5
77.5
171.5
65
65
EB3C-∗10N
EB3C-∗08N
EB3C-∗16CN
61
75
42
EB3C-∗06N
EB3C-∗05N
EB3C-∗08CN
ø4.4
Screw Terminal
EB3C-∗01N
4
6
77.5
(4)
M3
ø6 hole
10
10
10
10
10
Mounting Hole Layout (Screw Mounting)
2-M4 tapped or
2-ø4.5 mounting holes
28
2-M4 tapped or
2-ø4.5 mounting holes
51
4-M4 tapped or
4-ø4.5 mounting holes
97
65
65
2-M4 tapped or
2-ø4.5 mounting holes
97
External Wiring Examples
Transistor Output
(Ex.: EB3C-T06AN)
P5
P6
P7
P8
N1
N2
A1
A2
A3
A4
A5
A6
A7
A8
C1
C2
P1
P2
P3
P4
P5
P6
P7
P8
N1
N2
24V DC
+
–
A1
A2
A3
A4
A5
A6
A7
A8
C1
C2
Load Power
24V DC
P1
P2
P3
P4
P5
P6
P7
P8
N1
N2
P9 P10 P 11 P12 P13 P14 P15 P16 N3
N4
A1
A2
A3
A4
A5
A6
A7
A8
C1
C2
A9 A10 A 11 A12 A13 A14 A15 A16 C3
C4
24V DC
Load
Load
Power
24V DC
–
Load
Load
Load
Load
Load
Load
Load
P4
C6
+
100 to
240V AC
P3
Load
A6
P2
Load
C5
P1
Load
A5
N6
Load
C4
P6
Load
A4
N5
Load
C3
P5
Load
A3
N4
Transistor Source Output
(Ex.: EB3C-T08CSDN)
Load
C2
P4
Load
A2
N3
Load
C1
P3
Load
A1
N2
Load
N
P2
Load
L
N1
Load
P1
Transistor Sink Output
(Ex.: EB3C-T08CKDN)
Load Power
24V DC
Note: On the sink/source transistor output model, terminals
A can be used as a positive common line.
Relay Output Common Wiring
(Ex.: EB3C-R16CDN)
Relay Output
(Ex.: EB3C-R06AN)
–
24V DC
Load
Load
Load
Load
Load
100 to
240V AC
Load
+
Load
Load
Power
AC/DC
Load
C6
Load
A6
Load
C5
Load
A5
N6
Load
C4
P6
Load
A4
N5
Load
C3
P5
Load
A3
N4
Load
C2
P4
Load
A2
N3
Load
C1
P3
Load
A1
N2
Load
N
P2
Load
L
N1
Load
P1
Load
Power
AC/DC
7
EB3C Relay Barrriers
Connector Model Output Wiring Diagram
EB3C-T16CKD-CN (Sink)
Wiring Example with IDEC’s MicroSmart PLC Input Modules
EB3C-T16CKD-CN
CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16
A9
A10 A11 A12 A13 A14 A15 A16
NC
NC
CHn
19
1
20
2
A1
A2
A3
A4
A5
A6
A7
A8
C1
C2
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
+V
COM
EB3C
PLC
COM
Internal Circuit
Internal Circuit
+V (C1)
+
–
COM
+
An
A1-A16
Input
I0-I15
COM (C2)
EB3C-T16CSD-CN (Source)
CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16
A9
A10 A11 A12 A13 A14 A15 A16
NC
NC
19
1
20
2
A1
A2
A3
A4
A5
A6
A7
A8
C1
C2
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
–V
COM
EB3C
CHn
–
An
+
COM
PLC
FC4A-N16B3
Input
Terminal
Terminal
Output
Input
Terminal
20
A1
I0
20
20
A1
I0
20
19
A9
I10
19
19
A9
I10
19
18
A2
I1
18
18
A2
I1
18
17
A10
I11
17
17
A10
I11
17
16
A3
I2
16
16
A3
I2
16
15
A11
I12
15
15
A11
I12
15
14
A4
I3
14
14
A4
I3
14
13
A12
I13
13
13
A12
I13
13
12
A5
I4
12
12
A5
I4
12
11
A13
I14
11
11
A13
I14
11
10
A6
I5
10
10
A6
I5
10
9
A14
I15
9
9
A14
I15
9
8
A7
I6
8
8
A7
I6
8
7
A15
I16
7
7
A15
I16
7
6
A8
I7
6
6
A8
I7
6
5
A16
I17
5
5
A16
I17
5
4
+V
COM
4
4
–V
COM
4
3
NC
COM
3
3
NC
COM
3
2
COM
NC
2
2
COM
NC
2
1
NC
NC
1
1
NC
NC
1
Input
I0-I15
Internal Circuit
Internal Circuit
A1-A16
EB3C-T16CSD-CN
Output
Note: The wiring in dashed line does not affect the operation of the EB3C.
Applicable connector is IDEC’s JE1S-201.
Input power for PLC inputs is supplied by the EB3C, therefore the PLC input does not
need an external power supply.
COM (C2)
+
FC4A-N16B3
Terminal
COM
Wiring Example of Intrinsically Safe External Inputs
1. Common Wiring (Maximum 16 circuits)
P1
N1
P2
N2
P3
N3
P4
N4
P5
N5
P6
N6
L
N
A1
C1
A2
C2
A3
C3
A4
C4
A5
C5
A6
C6
N
N
N
P1
P2
P3
P4
P5
P6
P7
P8
N1
N2
P1
N1
P2
N2
P3
N3
L
N
A1
C1
A2
C2
A3
C3
N
L
N
A1
A2
A3
A4
A5
A6
A7
A8
C1
C2
P1
N1
N2
L
N
A1
C1
C2
N
L
N
A1
P1
C1
N1
A2
P2
C2
N2
A3
P3
C3
N3
A4
P4
C4
N4
A5
P5
C5
N5
A6
P6
C6
N6
A7
P7
C7
N7
A8
P8
C8
N8
A9
P9
C9
N9
A10 P10
C10 N10
P1
P2
P3
P4
P5
P6
P7
P8
N1
N2
P9
P10
P11
P12
P13
P14
P15
P16
N3
N4
L
N
A1
A2
A3
A4
A5
A6
A7
A8
C1
C2
A9
A10
A11
A12
A13
A14
A15
A16
C3
C4
All input lines are wired to a common line inside the intrinsically safe switch (one common line per intrinsically safe circuit).
N
N
N
N
P1
P2
P3
P4
P5
P6
P7
P8
N1
N2
L
N
A1
A2
A3
A4
A5
A6
A7
A8
C1
C2
P1
N1
P2
N2
P3
N3
P4
N4
P5
N5
P6
N6
L
N
A1
C1
A2
C2
A3
C3
A4
C4
A5
C5
A6
C6
N
L
N
A1
P1
C1
N1
A2
P2
C2
N2
A3
P3
C3
N3
A4
P4
C4
N4
A5
P5
C5
N5
A6
P6
C6
N6
A7
P7
C7
N7
A8
P8
C8
N8
A9
P9
C9
N9
A10 P10
C10 N10
P1
N1
P2
N2
P3
N3
P1
N1
N2
L
N
A1
C1
C2
N
L
N
A1
C1
A2
C2
A3
C3
P1
P2
P3
P4
P5
P6
P7
P8
N1
N2
P9
P10
P11
P12
P13
P14
P15
P16
N3
N4
L
N
A1
A2
A3
A4
A5
A6
A7
A8
C1
C2
A9
A10
A11
A12
A13
A14
A15
A16
C3
C4
Some input lines are wired to a common line inside the intrinsically safe switches, while others are outside switches
(one common line per intrinsically safe circuit).
N
P1
N1
P2
N2
P3
N3
P4
N4
P5
N5
P6
N6
L
N
A1
C1
A2
C2
A3
C3
A4
C4
A5
C5
A6
C6
N
2. Separate Wiring
Each input line of the EB3C makes up one independent intrinsically safe circuit.
8
N
N
P1
P2
P3
P4
P5
P6
P7
P8
N1
N2
P1
N1
P2
N2
P3
N3
L
N
A1
C1
A2
C2
A3
C3
N
L
N
A1
A2
A3
A4
A5
A6
A7
A8
C1
C2
P1
N1
N2
L
N
A1
C1
C2
N
L
N
A1
P1
C1
N1
A2
P2
C2
N2
A3
P3
C3
N3
A4
P4
C4
N4
A5
P5
C5
N5
A6
P6
C6
N6
A7
P7
C7
N7
A8
P8
C8
N8
A9
P9
C9
N9
A10 P10
C10 N10
P1
P2
P3
P4
P5
P6
P7
P8
N1
N2
P9
P10
P11
P12
P13
P14
P15
P16
N3
N4
L
N
A1
A2
A3
A4
A5
A6
A7
A8
C1
C2
A9
A10
A11
A12
A13
A14
A15
A16
C3
C4
All input lines are wired to a common line outside the intrinsically safe switch (one common line per intrinsically safe circuit).
N
P1
N1
P2
N2
P3
N3
P4
N4
P5
N5
P6
N6
L
N
A1
C1
A2
C2
A3
C3
A4
C4
A5
C5
A6
C6
P1
P2
P3
P4
P5
P6
P7
P8
N1
N2
P1
N1
P2
N2
P3
N3
L
N
A1
C1
A2
C2
A3
C3
N
L
N
A1
A2
A3
A4
A5
A6
A7
A8
C1
C2
P1
N1
N2
L
N
A1
C1
C2
N
N
L
N
A1
P1
C1
N1
A2
P2
C2
N2
A3
P3
C3
N3
A4
P4
C4
N4
A5
P5
C5
N5
A6
P6
C6
N6
A7
P7
C7
N7
A8
P8
C8
N8
A9
P9
C9
N9
A10 P10
C10 N10
P1
P2
P3
P4
P5
P6
P7
P8
N1
N2
P9
P10
P11
P12
P13
P14
P15
P16
N3
N4
L
N
A1
A2
A3
A4
A5
A6
A7
A8
C1
C2
A9
A10
A11
A12
A13
A14
A15
A16
C3
C4
N
EB3C Relay Barrriers
N
N
2. Separate Wiring
P1
N1
P2
N2
P3
N3
P1
N1
P2
N2
P3
N3
P4
N4
P5
N5
P6
N6
L
N
A1
C1
A2
C2
A3
C3
L
N
A1
C1
A2
C2
A3
C3
A4
C4
A5
C5
A6
C6
N
L
N
A1
P1
C1
N1
A2
P2
C2
N2
A3
P3
C3
N3
A4
P4
C4
N4
A5
P5
C5
N5
A6
P6
C6
N6
A7
P7
C7
N7
A8
P8
C8
N8
A9
P9
C9
N9
A10 P10
C10 N10
P1
N1
N2
L
N
A1
C1
C2
Each input line of the EB3C makes up one independent intrinsically safe circuit.
N
N
Diagram Symbols
N
Serial-Parallel Connection of Switches
Contacts in one switch
(EB9Z-A or EB9Z-A1)
L
N
A1
C1
C2
P1
N1
N2
One intrinsically safe circuit
(maximum 16 circuits)
Notes
• As shown in the diagram on the left, a required number of “contacts in one
switch” (3 contacts in the example at left) can be added to the “contacts in
one switch” connected to one input channel.
• Similarly, a required number of “contacts in one switch” can be added to a
common line connected to multiple input channels.
• The capacitance and inductance of the added “contacts in one switch”
must be included in the calculation of the wiring capacitance and inductance in “Precautions for Operation, 5. Wiring for Intrinsic Safety, (7)” on
page 11.
• In addition, a required number of contacts can be added in the enclosure of
“contacts in one switch.” In this case, however, do not include the capacitance and inductance in the calculation of the wiring capacitance and
inductance on page 11. Instead, make sure that the internal capacitance
(Ci) and internal inductance (Li) are within the values shown in the table
“Switch Explosion-Protection Specifications (Japan only)” on page 6.
Recommended Connector Cable for Connector Models
Description
No. of Poles
Length (m)
1
2
BX9Z-H200E4
3
BX9Z-H300E4
1
BX9Z-H100L
2
BX9Z-H200L
3
BX9Z-H300L
1
With Shield
2
I/O
Terminal
Cable
3
0.5
1
Without Shield
2
3
20
Cable with Crimping Terminal
Part No.
FC9Z-H050A20
FC9Z-H100A20
FC9Z-H200A20
FC9Z-H300A20
FC9Z-H050B20
FC9Z-H100B20
FC9Z-H200B20
FC9Z-H300B20
BX9Z-H100E4
0.5
Shape
Applicable Model
IDEC MicroSmart
I/O Module
IDEC MicroSmart
I/O Module
200
Screw Terminal
2
1
40-pin Cable for PLC
FC9Z-HA, FC9Z-HB
Internal Connection
Fujitsu Connecto
IDEC
Connector
FCN-367J024-AU/F
JE1S-201
19
20
17
18
15
13
16
14
11
12
9
10
7
8
5
6
3
1
4
2
(Connecting Side)
IDEC Connector
IDECJE1S-20111
Connector
JE1S-201
19
20
17
18
15
16
13
14
11
12
9
10
IDEC Connector
JE1S-201
IDEC Connector
JE1S-201
1
2
3
4
5
6
7
8
9
10
11 12
13 14
8
15 16
5
6
17 18
3
4
2
(Connecting Side)
19 20
0
Connector A
Mitsubishi A Series
Input Module
(positive common)
↓
EB3C-T16CKD-CN
BX9Z-HL Internal Connection
Y-shaped Compression
Terminal
Y-shaped
Compresion
(Marking
Tube No.) Terminal
1
3
5
7
9
11
13
15
17
19
Fujitsu Connector
FCN-367J040-AU/F
B A
1
1
2
2
3
3
2
4
4
4
5
5
6
6
6
7
7
8
8
9
9
(Marking Tube No.)
8
10
12
Connector A
IDEC
JE1S-201
14
2
1
16
4
3
18
6
5
20
8
7
10 9
(Connecting Side)
Connector B
10
BX9Z E4
Internal Connection
7
1
350
12 11
14 13
16 15
18 17
20 19
(Connecting Side)
Connector B
IDEC
JE1S-201
10 10
11 11
2
1
12 12
4
3
13 13
6
5
14 14
8
7
15 15
10 9
16 16
12 11
17 17
14 13
18 18
16 15
19 19
18 17
20 20
20 19
(Connecting Side)
(Connecting Side)
9
EB3C Relay Barrriers
Operating Instructions
1. Installation of EB3C Relay Barriers
Applicable Switches
(1) The EB3C can be installed in any direction.
(2) Install the EB3C relay barrier in a safe area (non-hazardous area) in
accordance with intrinsic safety ratings and parameters. To avoid
mechanical shocks, install the EB3C in an enclosure which suppresses
shocks.
Control
Switches
(3) When installing or wiring the EB3C, prevent electromagnetic and
electrostatic inductions in the intrinsically safe circuit. Also prevent the
intrinsically safe circuits from contacting with another intrinsically safe
circuit and any other circuits.
Maintain at least 50 mm clearance, or provide a metallic separating
board between the intrinsically safe circuit and non-intrinsically safety
circuit. When providing a metallic separating board, make sure that
the board fits closely to the enclosure (top, bottom, and both sides).
Allowable clearance between the enclosure and board is 1.5 mm at the
maximum.
Sensing
Switches
The clearance of 50 mm between the intrinsically safe circuit and
non-intrinsically safe circuit may not be sufficient when a motor circuit
or high-voltage circuit is installed nearby. In this case, provide a wider
clearance between the circuits referring to 5 (3) “Minimum Parallel
Distance between the Intrinsically Safe Circuit and Other Circuits.”
(4) In order to prevent contact between intrinsically safe circuits and nonintrinsically safe circuits, mount EB3C units with terminals arranged in
the same direction.
Intrinsically Safe Circuit
EB3C
Pushbutton, Foot, Trigger, Rocker, Grip
Twisting Switches
Rotary, Selector, Cam, Drum, Thumb wheel
Lever and Slide Switches
Toggle, Multidirectional, Wobble stick, Lever,
Slide switch
Displacement Switches
Microswitch, Limit, Magnetic proximity, Door,
Reed, Mercury
Level Switches
Liquid level
Others
Pressure, Temperature
Note: For installation in hazardous areas and connection to the EB3C, use switches which
are certified, approved, or considered to be simple apparatus in relevant standards in
each country.
(2) When the switch has internal wiring or lead wire, make sure that the
values of internal inductance (Li) and capacitance (Ci) are within the
certified values.
(3) Enclose the switch contact’s bare live part in an enclosure of IP20 or
higher protection.
(4) Depending on the explosion-protection specifications according to TIIS,
the exposed area of plastic switch operator is limited as follows:
• Exia II CT6 (EB9Z-A):
20 cm2 maximum
• Exia II BT6 (EB9Z-A1):
100 cm2 maximum
(5) Attach the certification mark supplied with the EB3C on the EB9Z-A or
EB9Z-A1 switch (for Japan application).
(6) When the switch operator of plastic enclosure has a wider exposed
area than the following limits, attach a caution label as shown below.
Caution
EB3C
EB3C
To prevent electrostatic charges, do
not rub the switch surface during
operation.
Use a soft cloth dipped with water
for cleaning.
2
II C: 20 cm maximum
II B: 100 cm2 maximum
EB3C
Non-intrinsically
Safe Circuit
Push-pull Switches
EB3C
Intrinsically Safe Circuit
(5) Maintain at least 6 mm (or 3 mm according to IEC60079-11: 1999)
clearance between the terminal of intrinsically safe circuit and the
grounded metal part of a metal enclosure, and between the relay
terminal block of an intrinsically safe circuit and the grounded metal
part of a metal enclosure.
(6) For installing the EB3C, mount on a 35-mm-wide DIN rail or directly
on a panel using screws. Make sure to install securely to withstand
vibration. When mounting on a DIN rail, push in the clamp completely.
Use the BNL6 end clips on both sides of the EB3C to prevent from
moving sideways.
Caution Label Example
(7) For the 1-circuit separate wiring, a resistor to prevent reed switch
contact welding and an LED miniature pilot lights can be connected in
series with the contact. See below. Use the terminal screw of M3 or
larger.
Applicable Resistor Ratings
Resistance
100Ω maximum
Rated Wattage
0.5 to 3W
Model
Metal (oxide) film resistors
R
(7) Excessive extraneous noise may cause malfunction and damage to
the EB3C. When extraneous noise activates the voltage limiting circuit
(thyristor), remove the noise source and restore the power.
Reed Switch
Terminal Block
2. Terminal Wiring
(1) Using a ø5.5 mm or smaller screw driver, tighten the terminal screws
(including unused terminal screws) to a torque of 0.6 to 1.0 N·m
(recommended value).
(2) Make sure that IP20 is achieved when wiring. Use insulation tubes on
bare crimping terminals.
(3) To prevent disengaged wires from contacting with other intrinsically
safe circuits, bind together the wires of one intrinsically safe circuit.
(4) When the adjacent terminal is connected to another intrinsically safe
circuit, provide an insulation distance of at least 6 mm.
10
EB3C
Applicable LED
IDEC’s IPL1 series LED miniature pilot lights. See pages 14 and 17.
EB3C Relay Barrriers
Operating Instructions
4. Output Specifications
(1) When wiring the output from the EB3C, connect the non-intrinsically
safe circuit to terminals A and C. The EB3C output circuit is not
equipped with short-circuit protection. If required, provide a protection
in the external circuit.
(2) Relay Output
Some types of loads generate reverse emf (such as solenoids) or cause
a large inrush current (incandescent lamps), resulting in a shorter
operation life of output relay contacts. The operation life of contacts
can be extended by preventing the reverse emf using a diode, RC, or
varistor, or by suppressing the inrush current using a resistor or RL.
Voltage and Current of Other
Circuits
Over 440V
440V or less
220V or less
110V or less
60V or less
Over 100A
100A or less 50A or less
2000
2000
2000
2000
2000
2000
600
600
600
500
10A or less
2000
600
600
500
300
2000
600
500
300
150
(4) When identifying intrinsically safe circuits by color, use light blue
terminal blocks and cables.
Contacts are made of gold-clad silver. When using at a small current
and a low voltage (reference value: 0.1 mA, 0.1V), test the contact on
the actual circuit in advance.
(5) When using two or more EB3C’s to set up one intrinsically safe circuit
in the common wiring configuration, interconnect two neutral terminals
(N1 through N10) on each EB3C between adjacent EB3C’s in parallel.
(3) Transistor Output
When connecting a small load, the load may not turn off because of a
leakage current, even though the transistor output is turned off. If this
is the case, connect a resistor in parallel with the load to bypass the
leakage current.
When an excessively high voltage (clamps at 33V, 1W) or a reverse
voltage is applied to the output terminals, the clamping circuit or output
transistor may be damaged.
(6) Make sure that the power of the EB3C and contact are turned off before
starting inspection or replacement.
(7) When wiring the intrinsically safe circuit, determine the distance to
satisfy the wiring parameters shown below. Note that parameters are
different between separate wiring and common wiring.
When driving an inductive load, be sure to connect a diode across the
load to absorb reverse emf.
An
Load
∗
Cn
∗: Surge Absorber
Example of Overvoltage Absorption Circuit
(4) In the common wiring only models, the output terminals are not isolated
from each other.
(5) When connecting the connector model EB3C’s in parallel, use one
power supply to power the EB3C’s. Do not connect any wiring to the C1
and C2 terminals.
5. Wiring for Intrinsic Safety
(1) The voltage applied on the general circuit connected to the nonintrinsically safe circuit terminals of the EB3C relay barrier must be
250V AC, 50/60Hz, or 250V DC at the maximum under any conditions,
including the voltage of the input power and the internal circuit.
(2) When wiring, take into consideration the prevention of electromagnetic
and electrostatic charges on intrinsically safe circuits. Also, prevent
intrinsically safe circuits from contacting with other circuits.
(3) The intrinsically safe circuits must be separated from non-intrinsically
safe circuits. Contain intrinsically safe circuits in a metallic tube or duct,
or separate the intrinsically safe circuits referring to the table below.
Note: Cables with a magnetic shield, such as a metallic sheath, prevent
electromagnetic induction and electrostatic induction, however, a nonmagnetic shield prevents electrostatic induction only. For non-magnetic
shields, take a preventive measure against electromagnetic induction.
Finely twisted pair cables prevent electromagnetic induction. Adding
shields to the twisted pair cables provides protection against electrostatic
induction.
a) Wiring capacitance Cw ≤ Co – (Ci + N × 2 nF)
Co: Maximum external capacitance of the EB3C
Ci: Internal capacitance of the switch
N: The number of switches connected in series or parallel (the
number is infinite)
b) Wiring inductance Lw ≤ Lo – (Li + N × 5 µH)
Lo: Maximum external inductance of the EB3C
Li: Internal inductance of the switch
N: The number of switches connected in series or parallel (the
number is infinite)
c) Wiring resistance ≤ Rw
Rw: Allowable wiring resistance
d) Allowable wiring distance D (km) is the smallest value of those
calculated from the capacitance, inductance, and resistance.
D ≤ Cw/C
D ≤ Lw/L
D ≤ Rw/2R
C (nF/km): Capacitance of cable per km
L (mH/km): Inductance of cable per km
R (Ω/km):
Resistance of cable per km
Note: For the details of wiring the intrinsically safe circuits, refer to a relevant test
guideline for explosion-proof electric equipment in each country.
(8) Applicable Wire Size
0.5 to 2.0 mm2 (AWG20 to AWG14): two wires
However, one wire for 2.0 mm2 (AWG14)
Mounting Bracket
The following mounting brackets can be used to install the EB3C relay barriers
and EB3L lamp barriers on the mounting holes of IBRC contact signal transducer,
IBPL pilot relay barrier, and IBZ buzzer.
No. of Channels
Part No.
1
2
3
5
6
10
EB9Z-K01
EB9Z-K02
EB9Z-K03
EB9Z-K05
EB9Z-K06
EB9Z-K10
A
28.0
51.0
51.0
97.0
97.0
97.0
Dimension (mm)
B
C
44.0
61.0
59.5
76.0
75.0
91.5
105.0
122.0
120.0
137.0
181.0
198.0
Dimensions
C
B
A
7
ø5 (four)
M4
(two or four)
∗
140
126
90
65
Minimum Parallel Distance between the Intrinsically Safe Circuit and
Other Circuits (mm)
∗
∗: EB9Z-K10 only
All dimensions in mm.
11
EB3L Lamp Barriers
126 types of pilot lights and buzzers can be connected and used in Zone 0 areas.
Illuminated pushbuttons and illuminated selector switches can be connected
by combining with the EB3C relay barrier.
Lamp Barrier
Pilot Light (separate wiring)
Pilot Light (common wiring)
Illuminated Pushbutton
Illuminated Selector Switch
Buzzer (separate wiring)*
Explosion protection
[Exia] II C
Exia II CT6
Exia II CT4
Exia II CT4
Exia II CT4
Exib II CT6
• IEC60079 compliant.
• 8- and 16-channel are available in common wiring, ideal for connection
to PLCs. 16-circuit also available with a connector.
• Universal AC power voltage (100 to 240V AC)
• No grounding required.
• IDEC’s original spring-up terminal minimizes wiring time.
• Installation
35-mm-wide DIN rail mounting or direct screw mounting.
• ø6, ø8, ø10, ø22 and ø30 pilot lights available.
• Illuminated pushbuttons and illuminated selector switches can be connected by combining with the EB3C relay barrier.
Illumination colors: Amber, blue, green, red, white, and yellow (pushlock
turn reset: red only)
• Buzzers are available in intermittent and continuous sounds. ø30 mountConnector Model
ing hole.
• Global usage
IECEx
USA:
FM, UL
Europe: CE marking, ATEX
* Buzzers are certified by TIIS only. Other ex-proof
certifications pending.
China: CQST
* Buzzers cannot be used in Zone 0 areas.
Korea: KCS
Taiwan: TS
Japan: TIIS
• Ship class: NK (Japan), KR (Korea)
12
EB3L Lamp Barrriers
Lamp Barriers
Power Voltage
Connection to
Non-intrinsically
Safe Circuit
Input
Source
100 to 240V AC
Input Wiring Method
(Note)
Number of
Channels
Separate/Common
Wiring Compatible
Common Wiring Only
Screw Terminal
Sink
Separate/Common
Wiring Compatible
Common Wiring Only
Source
Separate/Common
Wiring Compatible
Common Wiring Only
Screw Terminal
24V DC
Sink
Separate/Common
Wiring Compatible
Common Wiring Only
Connector
Source
Sink
Common Wiring Only
Part No.
Weight (g)
1
EB3L-S01SAN
150
2
EB3L-S02SAN
180
3
EB3L-S03SAN
190
5
EB3L-S05SAN
250
6
EB3L-S06SAN
260
8
EB3L-S08SAN
330
10
EB3L-S10SAN
360
8 (∗)
1
EB3L-S08CSAN
260
EB3L-S01KAN
150
2
EB3L-S02KAN
180
3
EB3L-S03KAN
190
5
EB3L-S05KAN
250
6
EB3L-S06KAN
260
8
EB3L-S08KAN
330
10
EB3L-S10KAN
360
8 (∗)
1
EB3L-S08CKAN
260
EB3L-S01SDN
130
2
EB3L-S02SDN
160
3
EB3L-S03SDN
170
5
EB3L-S05SDN
240
6
EB3L-S06SDN
250
8
EB3L-S08SDN
310
10
EB3L-S10SDN
250
8 (∗)
EB3L-S08CSDN
340
16 (∗)
1
EB3L-S16CSDN
350
EB3L-S01KDN
130
2
EB3L-S02KDN
160
3
EB3L-S03KDN
170
5
EB3L-S05KDN
240
6
EB3L-S06KDN
250
8 (∗)
10
EB3L-S08KDN
310
EB3L-S10KDN
340
8
EB3L-S08CKDN
250
16 (∗)
EB3L-S16CKDN
350
16 (∗)
EB3L-S16CSD-CN
350
16 (∗)
EB3L-S16CKD-CN
350
∗ Buzzers cannot be connected in common wiring.
Note: Source input model can be connected with sink output PLC. Sink input model can be connected with source output PLC.
Accessories
Name
DIN Rail
End Clip
Part No.
BAA1000
BAP1000
BNL6
Ordering No.
BAA1000PN10
BAP1000PN10
BNL6PN10
Package Quantity
10
10
10
Description
Aluminum (1m long)
Steel (1m long)
For fastening EB3L units on the DIN rail.
13
EB3L Lamp Barrriers
Pilot Lights, Illuminated Pushbuttons, Illuminated Selector Switches, and Buzzers
Unit
Series
(Note 1)
Size
ø30
N
Pilot Light
TW
ø22
HW
Miniature Pilot Light
LW
ø10
ø8
UP
ø6
ø30
N
Shape
Dome
Square
Rectangular w/Metal Bezel
Dome w/Diecast Sleeve
Flush
Flush (Marking Type)
Dome
Square Flush (Marking Type)
Round Flush
Dome
Square Flush
Round
Square
Round w/Square Bezel
Extended
Coned
Flush
Extended
Coned
Flush
Extended
Coned
Illuminated Pushbutton
HW
Round
Round
LW
Square
Buzzer
Illuminated Selector Switch
(Note 3)
ø30
N
Round
TW
Round
HW
Round
LW
Round
Round w/Square Bezel
—
—
ø22
ø30
Ordering No. (Note 2)
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
EB3P-LAN1-∗
EB3P-LUN3B-∗
EB3P-LUN4-∗
EB3P-LAD1-∗
EB3P-LAW1-∗
EB3P-LAW1B-∗
EB3P-LAW2-∗
EB3P-LUW1B-∗
EB3P-LHW1-∗
EB3P-LHW2-∗
EB3P-LHW4-∗
EB3P-LLW1-∗
EB3P-LLW2-∗
EB3P-LLW3-∗
IPL1-18-∗
IPL1-19-∗
IPL1-87-∗
IPL1-88-∗
IPL1-89-∗
IPL1-67-∗
IPL1-68-∗
IPL1-69-∗
Momentary
1NO-1NC
EB3P-LBAN211-∗
Maintained
1NO-1NC
EB3P-LBAON211-∗
Pushlock Turn Reset
1NO-1NC
EB3P-LBAVN311-R
Momentary
1NO-1NC
EB3P-LBAW211-∗
Maintained
1NO-1NC
EB3P-LBAOW211-∗
Pushlock Turn Reset
Momentary
Maintained
Momentary
Maintained
Momentary
Maintained
2-position
3-position
2-position
2-position, return from right
3-position
3-position, return from right
3-position, return from left
3-position, 2-way return
2-position
3-position
2-position
3-position
1NO-1NC
1NO
1NO
DPDT
DPDT
DPDT
DPDT
1NO-1NC
2NO
1NO-1NC
1NO-1NC
2NO
2NO
2NO
2NO
1NO-1NC
2NO
DPDT
DPDT
Continuous sound
—
EB3P-LBH1W110-∗
EB3P-LBHA1W110-∗
EB3P-LBL1W1C2-∗
EB3P-LBLA1W1C2-∗
EB3P-LBL2W1C2-∗
EB3P-LBLA2W1C2-∗
EB3P-LSAN211-∗
EB3P-LSAN320-∗
EB3P-LSAW211-∗
EB3P-LSAW2111-∗
EB3P-LSAW320-∗
EB3P-LSAW3120-∗
EB3P-LSAW3220-∗
EB3P-LSAW3320-∗
EB3P-LSHW211-∗
EB3P-LSHW320-∗
EB3P-LSL1W2C2-∗
EB3P-LSL3W3C2-∗
EB3P-ZUN12CN
Intermittent sound (approx. 3 Hz)
—
EB3P-ZUN12FN
Extended
Mushroom
ø22
Contact
Extended
Mushroom
TW
Operation Mode
EB3P-LBAVW411-R
Lens Color/
Illumination
Color Code∗
Operation
A: Amber
G: Green
R: Red
S: Blue
W: White
Y: Yellow
—
A: Amber
G: Green
R: Red
W: White
Y: Yellow
—
A: Amber
G: Green
R: Red
S: Blue
W: White
Y: Yellow
Red only
A: Amber
G: Green
R: Red
S: Blue
W: White
Y: Yellow
Red only
A: Amber
G: Green
R: Red
S: Blue
W: White
Y: Yellow
—
—
(Note 3)
(Note 4)
(Note 5)
(Note 3)
(Note 4)
(Note 5)
(Note 3)
(Note 4)
(Note 3)
(Note 4)
(Note 3)
(Note 4)
Maintained
Maintained
Maintained
Spring return from right
Maintained
Spring return from right
Spring return from left
2-way spring return
Maintained
Maintained
Maintained
Maintained
Approx. 3 Hz
Note 1:
Codes N, TW, HW, LW, and UP are the series names of IDEC’s switches and pilot lights.
Note 2:
Specify a color code in place of ∗.
Note 3:
Momentary operation mode—the contact operates when the button is pressed. When the button is released, the contact goes back to the original position.
Note 4:
Maintained operation mode—the contact operates when the button is pressed, and maintains the position even when the button is released.
Re-pressing the button releases the contact.
Note 5:
Pushlock turn reset operation mode—the button is held depressed when pressed, and released by turning clockwise.
Note 6:
Illuminated selector switches have a knob operator.
Note 7:
Lamp barrier and relay barrier need to be connected when using the illuminated pushbutton and illuminated selector switch.
Accessories
Name
Ordering No.
Package Quantity
Remarks
LED Lamp
EB9Z-LDS1-∗
1
Specify a color code in place of ∗ in the Ordering No.
A: amber, G: green, R: red, S: blue, W: white
Static Electricity Caution Plate
EB9Z-N1PN10
10
Polyester 20 (W) x 6 (H) mm
Note: Use a pure white (PW) LED lamp for yellow (Y) illumination.
14
EB3L Lamp Barrriers
Explosion-Protection and Electrical
Specifications of Lamp Barrier
Lamp Barrier
Safe indoor place (non-hazardous area)
Pilot Light, Illuminated Switch
For zone 0, 1, 2 hazardous areas
Buzzer
For zone 1, 2 hazardous areas
250V AC 50/60Hz, 250V DC
Operation
Input ON, Output ON (1:1)
Intrinsically Safe Circuits (Output)
Non-intrinsically Safe Circuit
Maximum Voltage (Um)
Wiring Method
1-channel
Separate Wiring
Rated Operating Voltage
12V DC
Rated Operating Current
10 mA DC ±20%
Maximum Output Voltage (Uo)
13.2V DC
16-channel
Common Wiring
Maximum Output Current (lo)
14.2 mA
227.2 mA
Maximum Output Power (Po)
46.9 mW
750 mW
470 (470) nF
490 (365) nF
87.5 (87.5) mH
0.6 (0.425) mH
Maximum External
Capacitance (Co) (Note)
Maximum External
Inductance (Lo)
(Note)
Allowable Wiring
Resistance (Rw)
Maximum Channels per
Common Line
Voltage and Current when
Connecting Control Units
Non-intrinsically Safe Circuits
(Signal Input)
200/(n+1)Ω
(n = number of common channels)
8 (16 maximum)
Pilot light:
3.5V, 8.5 mA
Miniature pilot light: 2V, 10 mA
Illuminated switch: 3.5V, 8.5 mA
Buzzer:
6.5V, 5.5 mA
Rated voltage: 24V DC
Rated current: 5 mA (connector model: 4 mA)
Note: Values in ( ) are those approved by TIIS (Technology Institution of Industrial Safety,
Japan).
General Specifications of Lamp Barrier
Power Voltage Type
AC Power
DC Power
Rated Power Voltage
100 to 240V AC
(–15 to +10%)
24V DC (±10%)
Allowable Voltage Range
85 to 264V AC
21.6 to 26.4V DC
Rated Frequency
Inrush Current
Dielectric Strength
(1 minute, 1 mA)
50/60 Hz
—
(allowable range: 47 to 63 Hz)
10A (100V AC)
10A
20A (200V AC)
Between AC power and signal input: 1500V AC
Between intrinsically safe circuit and non-intrinsically safe
circuit: 1526.4V AC (except for DC power and signal input)
Operating Temperature
–20 to +60°C (no freezing)
Storage Temperature
–20 to +60°C (no freezing)
Operating Humidity
45 to 85% RH (no condensation)
Atmosphere
800 to 1100 hPa
Pollution Degree
2 (IEC60664)
Insulation Resistance
Vibration Resistance
(damage limits)
10 MΩ minimum (500V DC megger, between the same poles
as the dielectric strength)
Panel mounting: 10 to 55 Hz, amplitude 0.75 mm
(2 hours each on X, Y, Z)
DIN rail mounting: 10 to 55 Hz, amplitude 0.35 mm
(2 hours each on X, Y, Z)
–20 to +60°C (no freezing)
45 to 85% RH (no condensation)
EB3P: 1000V AC
Dielectric Strength
IPL1: 500V AC
(1 mA, 1 minute)
(between intrinsically safe circuit and dead parts)
10 MΩ minimum (500V DC megger, between the same
Insulation Resistance
poles as the dielectric strength)
IP65 (IEC60529) (except for terminals)
Degree of Protection
EB3P-LU/IPL1: IP40
Pilot light: Amber, blue, green, red, white, yellow
Lens/Illumination Color
Miniature pilot light: Amber, green, red, white, yellow
1-channel Separate Wiring
Maximum input voltage (Ui): 13.2V
Maximum input current (Ii): 14.2 mA
Maximum input power (Pi): 46.9 mW
Internal capacitance (Ci): ≤ 2 nF
Intrinsic Safety
Internal inductance (Li):
≤ 5 µH
Ratings and
16-channel Common Wiring
Parameters
Maximum input voltage (Ui): 13.2V
Maximum input current (Ii): 227.2 mA
Maximum input power (Pi): 750 mW
Internal capacitance (Ci): ≤ 32 nF
Internal inductance (Li):
≤ 80 µH
IP65 (IEC60529) (except for terminals)
Degree of Protection
EB3P-LSAW∗∗: IP54
Illumination Color
Amber, blue, green, red, white, yellow
Contact
12V DC ±10%, 10 mA ±20%
Voltage/Current
(when connecting to the EB3C)
16-channel Common Wiring
Maximum input voltage (Ui): 13.2V
Intrinsic Safety
Maximum input current (Ii): 227.2 mA
Ratings and
Maximum input power (Pi): 750 mW
Parameters
Internal capacitance (Ci): ≤ 32 nF
Internal inductance (Li):
≤ 80 µH
Degree of Protection
IP20 (IEC60529) (except for terminals)
Sound Volume
75 dB minimum (at 1 m)
Sound Source
Piezoelectric oscillator (continuous or intermittent)
1-channel Separate Wiring
Maximum input voltage (Ui): 13.2V
Intrinsic Safety Ratings Maximum input current (Ii): 14.2 mA
and Parameters
Maximum input power (Pi): 46.9 mW
Internal capacitance (Ci): ≤260 nF
Internal inductance (Li):
≤80 mH
Weight
100g
Pilot Light and Miniature Pilot Light
Operating Temperature
Operating Humidity
Illuminated Switch
IP20 (IEC60529)
Buzzer
Intrinsic safety type
Degree of Protection
Installation
Location
Explosion Protection
General Specifications of Pilot Light, Illuminated
Pushbutton, Illuminated Selector Switch, and Buzzer
Note: Connect buzzers in separate wiring. Buzzers cannot be used in common wiring.
Certification No.
Certification Organization
FM
c-UL
PTB (ATEX)
PTB (IECEx)
CQST
KCs
Panel mounting: 500 m/s2 (3 times each on X, Y, Z)
Shock Resistance
(damage limits)
DIN rail mounting: 300 m/s2 (3 times each on X, Y, Z)
Terminal Style
M3 screw terminal
Mounting
35-mm-wide DIN rail or panel mounting (M4 screw)
Power Consumption
(approx.)
8.8 VA (EB3L-S10SAN at 200V AC)
5.2 W (EB3L-S16CSDN at 24V DC)
TIIS
NK
KR
Explosion Protection
Class I, II, III Div. 1
Group A, B, C, D, E, F, G
Class I, Zone 0 AEx [ia] II C
Class I, II, III Div. 1
Group A, B, C, D, E, F, G
Class I, Zone 0 [AEx ia] II C
Lamp barrier: [Exia] II C
Buzzer:
Exib II CT6
Lamp barrier: [Exia] II C
Lamp barrier: [Exia Ga] II C
Buzzer:
Exib II CT6
Lamp barrier: [Exia] II C
Buzzer:
Exib II CT6
Lamp barrier: [Exia] II C
Pilot light/Miniature pilot light:
(separate wiring:) Exia II CT6
Pilot light/Miniature pilot light:
(common wiring:) Exia II CT4
Illuminated switch: Exia II CT4
Buzzer:
Exib II CT6
Lamp barrier: [Exia] II C
Buzzer:
Exib II CT6
Lamp barrier: [Exia] II C
Buzzer:
Exib II CT6
Certification No.
FM16US0364X
E234997
(except buzzer)
PTB09 ATEX2046
15 ATEX 6163X
IECEx PTB10.0015
CNEx 14.0047
CNEx 15.2108X
14-AV4B0-0375
17-AV4B0-0355X
TC20541
TC16361
TC16360
TC16362
TC20797
TA18437M
TA17025M
TYK17821-EL003
TYK17821-EL002
Note: Illuminated switches, pilot lights, and miniature pilot lights are certified by TIIS and
NK only. Other certification organizations regard these units as simple apparatus, and
require no certification.
Buzzers are certified by TIIS only. Other ex-proof certifications pending.
15
EB3L Lamp Barrriers
Internal Circuit Block Diagram
AC Power
Source Input
DC Power
Sink Input
Connector Wiring
Source Input
Hazardous Area
P1 N1 P2 N2 P3 N3
Yellow
Green
Yellow
P1 N1 P2 N2 P3 N3
Yellow
Green
–
Yellow
Yellow
Yellow
L
+–
+–
N S1 C1 S2 C2 S3 C3
+
Safe Area
(Non-hazardous Area)
Yellow
–
~
~
~
+–
N2
–
–
–
P16 N1
Yellow
Green
–
–
~
P1
–+
–
–+
~
~
~
–+
S1 C1 S2 C2 S3 C3
+
–
S1
S16 C1 C2
Dimensions
Terminal
EB3L–S01 N
65
EB3L–S08 N
EB3L–S10 N
EB3L–S16C N
110.5
Intrinsic Safety Side:
Light Blue
77.5
171.5
61
75
65
42
EB3L–S05 N
EB3L–S06 N
EB3L–S08C N
N
N
ø4.4
EB3L–S02
EB3L–S03
(4)
ø6 hole
4
6
77.5
Non-Intrinsic Safety Side:
Yellow
10
10
10
10
10
2-M4 tapped or
2-ø4.5 mounting holes
28
2-M4 tapped or
2-ø4.5 mounting holes
4-M4 tapped or
4-ø4.5 mounting holes
97
97
51
65
2-M4 tapped or
2-ø4.5 mounting
holes
65
Mounting Hole Layout (Screw Mounting)
Connector
EB3L-S16C-CN
Applicable Crimping Terminal
ø3.2 min.
3 max.
4-M4 or 4-ø4.5 holes
5.4 min.
65
75
4- ø4.4 holes
65
6 max.
M36
ø
171.5
Stripping the Wire End
Solid Wire
(4)
83.5
97
Mounting Hole Layout
6 to 8 mm
77.5
Stranded Wire (Ferrule)
6
6 to 8 mm
10
16
97
10
All dimensions in mm.
EB3L Lamp Barrriers
28.5
34.3
13
17
30
28.5
34.3
13
17
Panel Thickness 0.8 to 6
Gasket
Locking Ring
Flush
Dome
36
52.2
34
ø40
13
25
M3.5
Terminal
Screw
28.5
34.3
30
13
16
30
Marking Plate:
22
Panel Thickness 0.8 to 6
Gasket
7.2
Square
Round/Dome
EB3P-LUW1B
ø22
Terminal Cover (supplied)
Panel Thickness 1 to 6
APS-PVL
EB3P-LLW1/EB3P-LLW2/EB3P-LLW3
ø22
Terminal cover attached.
M3.5 Terminal Screw
28.5
34.3
30
Marking Plate: ø15.5
40
44
37
M3.5
Terminal
Screw
EB3P-LHW1/EB3P-LHW2/EB3P-LHW4
ø22
EB3P-LAW2
ø22
20
23
40
Terminal Cover (supplied)
Panel Thickness 1 to 6
APS-PVL
37
M3.5
Terminal
Screw
37
ø29
ø24
M3.5
Terminal
Screw
EB3P-LAW1B
ø22
Terminal Cover (supplied)
APS-PVL
Panel Thickness 1 to 6
Terminal Cover (supplied)
APS-PVL
Panel Thickness 1 to 6
9
21.4
29.8
Panel Thickness 0.8 to 5.5
25
30
EB3P-LAW1
ø22
40
44
10.5
Terminal Cover: APN-PVL
(sold separately)
M3 Terminal
Screw
37
29.5
40
ø29
23.5
Panel Thickness 0.8 to 7.5
36
52.2
34×40
36
ø35
21.5
M3.5 Terminal
Screw
Panel Thickness 0.8 to 4.5
EB3P-LUN3B
ø30
Terminal Cover: APD-PVL
(sold separately)
ø24.8
ø35
M3 Terminal
Screw
Panel Thickness 0.8 to 7.5
EB3P-LAD
ø30
Terminal Cover: APN-PVL
(sold separately)
ø24
M3 Terminal
Screw
EB3P-LUN4
ø30
Terminal Cover: APN-PVL
(sold separately)
ø23.6
ø29
Pilot Lights
EB3P-LAN1
ø30
Square Round w/square bezel
Round
Locking Ring
9
ø2
IPL1-89
20.3
11.5
2.5
4.6
Terminal cover: N-VL4 (2 pcs.) (sold separately)
M3.5 Terminal Screw
M3.5 Terminal Screw
5.5
30
ø22
M3.5 Terminal
Screw
Adjustment
Ring
Panel Thickness
1 to 6
ø22
Terminal cover: LW-VL2M (sold separately)
Panel Thickness 0.8 to 6
36
Panel Thickness 0.8 to 6
Locking Ring
LO
CK
Lever Stop
9
ø2
49.4
13
29.4
EB3P-LBL2W1C2/LBLA2W1C2
Terminal cover: LW-VL2M (sold separately)
Panel Thickness 0.8 to 6
23.2
23.2
K
K
C
C
LO
M3 Terminal
Screw
M3.5 Terminal
Screw
13
22.5
R18
EB3P-LBL1W1C2/LBLA1W1C2
R18
ø40
37
ø24
ø29
69.4
LO
M3 Terminal
Screw
13
19.5
30
Reset 75°
EB3P-LBH1W110/LBHA1W110
Terminal cover attached.
41.4
Panel Thickness
1 to 6
EB3P-LBAVW411-R
Terminal cover attached.
25
ø22
ø2
Adjustment
Ring
40
23.5
37
EB3P-LBAW211/LBAOW211
69.4
ø22
23
63
Terminal cover attached.
M3.5 Terminal
Screw
ø40
ø40
40
23.5
4
ø22
ø35
ø24
9
63
Panel Thickness 0.8 to 7.5
M3 Terminal Screw
Panel Thickness 0.8 to 7.5
23
3
EB3P-LBAVN311-R
ø30
Terminal cover: N-VL4 (2 pcs.) (sold separately)
5.5
Panel Thickness 0.6 to 4
7
11.3
19.8
3.5
18.5
Illuminated Pushbuttons
EB3P-LBAN211/LBAON211
ø30
M3 Terminal Screw
M6 P0.75
+ Terminal
7
10
4.6
4.6
7
11.8
5
4.5
IPL1-69
ø6
Panel Thickness 0.6 to 4
M6 P0.75
+ Terminal
9.2
11.5
6.1
9
11.8
19.8
IPL1-68
ø6
Panel Thickness 0.6 to 4
M6 P0.75
+ Terminal
ø8.1
ø10
+ Terminal
IPL1-67
ø6
Panel Thickness 0.6 to 4
M8 P0.75
3
9.2
ø8
21.8
5
9
11.5
19.5
9.2
5.5
20
9
13.8
6.1
12.8
20.8
Panel Thickness 0.6 to 4
M8 P0.75
+ Terminal
ø12
13.8
7
ø12
13.8
7
9
9
12
25.8
IPL1-88
ø8
Panel Thickness 0.6 to 4
M8 P0.75
+ Terminal
ø9.9
+ Terminal
+ Terminal
IPL1-87
ø8
Panel Thickness 0.6 to 4
25.8
ø6
ø7.5
M10 P1.0
Panel Thickness 0.6 to 4
6.1
P1.0
ø7.5
M10
9
11.5
Miniature Pilot Lights (Terminal cover not available)
ø10
ø10
IPL1-18
IPL1-19
19
26.8
7.7
ø10
M3 Terminal
Screw
29.6
ø10
17.5
7
ø7.5
0.5
43.3
5.8
X1
ø2
4.5
X2
5.
9
ø2
53.5
8
8.5 11.7
25.4
8.5 11.7
25.4
53.5
25.8
9
All dimensions in mm.
17
EB3L Lamp Barrriers
Illuminated Selector Switches
Terminal cover: N-VL4 (2 pcs.) (sold separately)
M3.5 Terminal
Screw
Terminal cover attached
M3.5 Terminal
Screw
Panel Thickness 0.8 to 7.5
Panel Thickness 1 to 6
69.4
40
9
Panel Thickness
0.8 to 6
K
ø2
Terminal cover: LW-VL2M (sold separately)
M3 Terminal
Screw
23.2
41.4
25
CK
.8
LO
C
LO
Panel Thickness
0.8 to 6
30
EB3P-LSL1W2C2/EB3P-LSL3W3C2
ø22
Terminal cover attached
25
ø2
5
28
EB3P-LSHW211/EB3P-LSHW320
M3.5 Terminal
Screw
37
13
9
63
R18
23
ø24
ø25
ø35
5.5
ø29
9
M3 Terminal
Screw
ø22
EB3P-LSAW
ø22
EB3P-LSAN211/EB3P-LSAN320
ø40
ø30
8.5 11.7
25.4
7
69.4
9
17.5
21
Buzzer
ø30
53.5
29.4
LED Lamp
EB3P-ZUN12CN/EB3P-ZUN12FN
Terminal cover: AZ-VL5 (sold separately)
EB9Z-LDS1
Panel Thickness
0.8 to 3.5
20.4
Illumination Color
10.6
IDEC Exi
ø50
M3.5 Terminal Screw
Intrinsic Safety Identification: Light Blue
35.5
Illumination color is marked on the terminal.
Polarity Identification
Panel Cut-out
Pilot Lights/Illuminated Pushbuttons/Illuminated
Selector Switches
Positive terminal:
X1
Negative terminal: X2
Pilot Lights/Illuminated Pushbuttons/Illuminated
Selector Switches/Buzzers
ø22
R0.8 max.
0.5
R0.8 max.
∗4.8
+0.2
0
∗3.2
ø22
+0
0 .5
.3
33
Pin Terminals
+0.4
0
+0.2
0
24.1
Long pin terminal
Short pin terminal
ø3
+0.5
0
Miniature Pilot Lights
Positive terminal:
Negative terminal:
ø30
+0.4
0
41
Positive Terminal
Light Blue Marking
Negative Terminal
Buzzer
Positive terminal:
Negative terminal:
Miniature Pilot Lights
ø10
ø8
+
–
LED Lamp
1
8.
1
0.
ø1
.3
+0 0
.3
+0 0
ø
ø6
.3
+0 0
.1
ø6
+ Positive
− Negative
∗ The 4.8 or 3.2 recess is needed only when using an anti-rotation
ring or a nameplate with an anti-rotation projection.
EB3P-LHW does not have an anti-rotation groove.
Lamp Test
When checking the lamp lighting without using the EB3L lamp barrier,
first make sure that the atmosphere is free from explosive gases.
Connect a 12V DC power supply and a protection resistor of 1 kΩ in
series to turn on the pilot light.
18
1 kΩ
Pilot Light
12V DC
EB3L Lamp Barrriers
Non-intrinsically Safe External Input Wiring Examples
6-channel Source
(Ex.: EB3L-S06SAN)
8-channel Common Wiring, Source
(Ex.: EB3L-S08CSDN)
P1 N1 P2 N2 P3 N3 P4 N4 P5 N5 P6 N6
+
L
N
–
+ –
+ –
+
–
+
–
+
+
–
+
100 to
240V AC
+
+
+
+
+
+
+
+
L
S1 S2 S3 S4 S5 S6 S7 S8 C1 C2
P2
P3
P4
+
+
+
+
S1
S2
S3
S4
P5
P6
P7
P8
+
+
+
+
S5 S6
S7
S8
N
+
+
+
+
+
S1 C1 S2 C2 S3 C3 S4 C4 S5 C5 S6 C6
100 to
240V AC
24V DC
16-channel Common Wiring, Source
(Ex.: EB3L-S16CSDN)
+
P1 N1 P2 N2 P3 N3 P4 N4 P5 N5 P6 N6
P1 P2 P3 P4 P5 P6 P7 P8 N1 N2
S1 C1 S2 C2 S3 C3 S4 C4 S5 C5 S6 C6
P1
6-channel Sink
(Ex. EB3L-S06KAN)
16-channel Common Wiring, Sink
(Ex.: EB3L-S16CKDN)
N1
N2
P9 P10 P11 P12 P13 P14 P15 P16 N3
C1
C2
S9 S10 S11 S12 S13 S14 S15 S16 C3
+
+
+
+
+
+
+
N4
P1
P2
P3
P4
P5
P6
P7
P8
S1
S2
S3
S4
S5 S6
S7
S8
+
N1
+
+
C4
C1
N2
P9 P10 P11 P12 P13 P14 P15 P16 N3
+
N4
+
C2
+
S9 S10 S11 S12 S13 S14 S15 S16 C3
C4
24V DC
24V DC
Note: Source input model can be connected to PLC sink output model
C terminal is the negative common line.
Note: Sink input model can be connected to PLC source output model
C terminal is the positive common line.
Connector Wiring Terminal Arrangement
Wiring Example with IDEC’s MicroSmart PLC Output Modules
EB3L-S16CSD-CN
CH9
S9
FC6A-T16K3
CH10 CH11 CH12 CH13 CH14 CH15 CH16
S10
S11
S12
S13
S14
S15
S16
NC
Terminal
NC
19
1
20
2
S1
S2
S3
S4
S5
S6
S7
S8
C1
C2
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
COM
+V
EB3L
CHn
Sn COM
–
+
PLC
+
Output
Q0-Q15
S1-S16
Internal Circuit
Internal Circuit
+V (C2)
COM (C1)
COM
EB3L-S16CKD-CN
S9
CH10 CH11 CH12 CH13 CH14 CH15 CH16
S10
S11
S12
S13
S14
S15
S16
NC
NC
19
1
20
2
S1
S2
S3
S4
S5
S6
S7
S8
C1
C2
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
COM
–V
EB3L
PLC
Internal Circuit
COM (C1)
+
CHn
Sn COM
+
–
COM
S1-S16
Output
Q0-Q15
Internal Circuit
CH9
Output
EB3L-S16CSD-C
FC6A-T16P3
Input
Terminal
Terminal
Output
EB3L-S16CKD-C
Input
Terminal
20
Q0
S1
20
20
Q0
S1
20
19
Q10
S9
19
19
Q10
S9
19
18
Q1
S2
18
18
Q1
S2
18
17
Q11
S10
17
17
Q11
S10
17
16
Q2
S3
16
16
Q2
S3
16
15
Q12
S11
15
15
Q12
S11
15
14
Q3
S4
14
14
Q3
S4
14
13
Q13
S12
13
13
Q13
S12
13
12
Q4
S5
12
12
Q4
S5
12
11
Q14
S13
11
11
Q14
S13
11
10
Q5
S6
10
10
Q5
S6
10
9
Q15
S14
9
9
Q15
S14
9
8
Q6
S7
8
8
Q6
S7
8
7
Q16
S15
7
7
Q16
S15
7
6
Q7
S8
6
6
Q7
S8
6
5
Q17
S16
5
5
Q17
S16
5
4
COM (–)
COM
4
4
COM (+)
COM
4
3
COM (–)
NC
3
3
COM (+)
NC
3
2
+V
+V
2
2
–V
–V
2
1
+V
NC
1
1
–V
NC
1
Note: The wiring in dashed line does not affect the operation of the EB3L.
Applicable connector is IDEC’s JE1S-201.
Output power for PLC outputs is supplied by the EB3L, therefore the PLC output does not
need an external power supply.
19
EB3L Lamp Barrriers
Wiring Example of Intrinsically Safe External Outputs
1. Common Wiring (Maximum 16 circuits) (Buzzers cannot be wired in a common line.)
N
N
N
(+)(–)
P1
P2
P3
P4
P5
P6
P7
P8
N1
N2
(+)(–)
L
N
S1
S2
S3
S4
S5
S6
S7
S8
C1
C2
L
N
P1
S1
N1
C1
P2
S2
N2
C2
P3
S3
N3
C3
P4
S4
N4
C4
P5
S5
C5
N5
S6
P6
C6
N6
P7
S7
C7
N7
S8
P8
C8
N8
S9
P9
C9
N9
S10 P10
C10 N10
S3
C3
S4
C4
S5
C5
S6
C6
P1
N1
P2
N2
P3
N3
P4
N4
P5
N5
P6
N6
(+)(–)
L
N
S1
C1
S2
C2
L
N
(+)(–)
S1
C1
S2
C2
S3
C3
P1
N1
P2
N2
P3
N3
P1
N1
N2
S1
C1
C2
(+)(–)
L
N
L
N
S1
S2
S3
S4
S5
S6
S7
S8
C1
C2
S9
S10
S11
S12
S13
S14
S15
S16
C3
C4
(+)(–)
P1
P2
P3
P4
P5
P6
P7
P8
N1
N2
P9
P10
P11
P12
P13
P14
P15
P16
N3
N4
All output lines are wired to a common line inside the intrinsically safe equipment (one common line per intrinsically safe circuit).
N
N
N
N
N
(+)(–)
N
2. Separate Wiring
P1
N1
P2
N2
P3
N3
P4
N4
P5
N5
P6
N6
(+)(–)
N
N
L
N
P1
S1
N1
C1
P2
S2
N2
C2
P3
S3
N3
C3
P4
S4
N4
C4
P5
S5
C5
N5
S6
P6
C6
N6
P7
S7
C7
N7
S8
P8
C8
N8
S9
P9
C9
N9
S10 P10
C10 N10
(+)(–)
L
N
S1
C1
S2
C2
S3
C3
L
N
S1
C1
C2
(+)(–)
L
N
S1
C1
S2
C2
S3
C3
S4
C4
S5
C5
S6
C6
P1
N1
N2
P1
N1
P2
N2
P3
N3
Each output line of the EB3L makes up one independent intrinsically safe circuit of a pilot light or buzzer.
(+)(–)
N
(A maximum of 16 channels of EB3L and EB3C can be wired to a common line.)
The following example illustrates the wiring for a total of 10 contacts used by three illuminated
pushbuttons (LB1 to LB3) and three illuminated selector switches (LS1 to LS3).
LS1
LS2
LS3
L
N
S1
C1
S2
C2
S3
C3
S4
C4
S5
C5
S6
C6
(+)(ñ)
N
20
LB1
LB2
LB3
LS1
LS2
LS3
L
N
P1
A1
N1
C1
P2
A2
N2
C2
P3
A3
N3
C3
P4
A4
N4
C4
P5
A5
C5
N5
A6
P6
C6
N6
P7
A7
C7
N7
A8
P8
C8
N8
A9
P9
C9
N9
A10 P10
C10 N10
LB3
P1
N1
P2
N2
P3
N3
P4
N4
P5
N5
P6
N6
LB2
P1
P2
P3
P4
P5
P6
P7
P8
N1
N2
N
Note:
When using two or more EB3L's
to set up one intrinsically safe circuit
in the common wiring configuration,
interconnect two neutral terminals
(N1 through N10) on each EB3L
between adjacent EB3L's in parallel.
N
3. Wiring Illuminated Pushbuttons and Illuminated Selector Switches
LB1
N
(+)(–)
L
N
S1
S2
S3
S4
S5
S6
S7
S8
C1
C2
L
N
P1
S1
N1
C1
P2
S2
N2
C2
P3
S3
N3
C3
P4
S4
N4
C4
P5
S5
C5
N5
S6
P6
C6
N6
P7
S7
C7
N7
S8
P8
C8
N8
S9
P9
C9
N9
S10 P10
C10 N10
(+)(–)
L
N
S1
C1
S2
C2
S3
C3
S4
C4
S5
C5
S6
C6
L
N
S1
C1
S2
C2
S3
C3
N
P1
N1
P2
N2
P3
N3
P4
N4
P5
N5
P6
N6
P1
N1
P2
N2
P3
N3
(+)(–)
(+)(–)
L
N
S1
C1
C2
L
N
S1
S2
S3
S4
S5
S6
S7
S8
C1
C2
S9
S10
S11
S12
S13
S14
S15
S16
C3
C4
(+)(–)
P1
N1
N2
P1
P2
P3
P4
P5
P6
P7
P8
N1
N2
P9
P10
P11
P12
P13
P14
P15
P16
N3
N4
All input lines are wired to a common line outside the intrinsically safe equipment (one common line per intrinsically safe circuit).
(+)(ñ)
N
Diagram Symbols
EB3P consisting of one
enclosure
One intrinsically safe circuit
One intrinsically safe circuit is a connection
consisting of one or more illuminated units
connected to a common line.
EB3L Lamp Barrriers
Recommended Connector Cable for Connector Models
Description
No. of Poles
Length (m)
Part No.
1
FC9Z-H050A20
FC9Z-H100A20
FC9Z-H200A20
FC9Z-H300A20
FC9Z-H050B20
FC9Z-H100B20
FC9Z-H200B20
FC9Z-H300B20
BX9Z-H100E4
2
BX9Z-H200E4
3
BX9Z-H300E4
1
BX9Z-H100B
2
BX9Z-H200B
3
BX9Z-H300B
0.5
1
With Shield
2
I/O
Terminal
Cable
3
0.5
1
Without Shield
2
20
Cable with Crimping Terminal
3
Shape
Applicable Model
IDEC MicroSmart
I/O Module
IDEC MicroSmart
I/O Module
200
Screw Terminal
2
1
40-pin Cable for PLC
350
Connector B
Mitsubishi A Series
Output Module (sink)
↓
EB3L-S16CSD-CN
10
0
BX9Z-HB Internal Connection
FC9Z-HE
Internal Connection
Fujitsu Connector
FCN-367J040-AU/F
IDEC Connector
JE1S-201
B A
Connector A
IDEC
JE1S-201
2
1
4
3
6
5
8
7
10 9
12 11
14 13
16 15
18 17
20 19
(Connecting Side)
Connector A
1
1
2
2
1 2
3
3
3 4
4
4
5 6
5
5
7 8
6
6
9 10
7
7
8
8
9
9
Connector B
IDEC
JE1S-201
10 10
5
7
9
11
11 12
13
15
15 16
2
1
17 18
12 12
4
3
19 20
13 13
6
5
14 14
8
7
15 15
10 9
16 16
12 11
17 17
14 13
18 18
16 15
19 19
18 17
20 20
20 19
(Connecting Side)
1
3
13 14
11 11
(Connecting Side)
Y-shaped Crimping Terminal
(marking tube number)
17
19
(Connecting Side)
2
4
6
8
10
12
14
16
18
20
(Connecting Side)
(Straight wire connection BX9Z-H B: number of
cable with crimping terminal)
FC9Z-HA, FC9Z-HB
Internal Connection
IDEC Connector
JE1S-201
19
20
17
18
15
16
13
14
11
12
9
10
7
8
5
6
3
4
1
2
(Connecting Side)
IDEC Connector
JE1S-201
19
20
17
18
15
16
13
14
11
12
9
10
7
8
5
6
3
4
1
2
(Connecting Side)
21
EB3L Lamp Barrriers
Operating Instructions
1. Installation of EB3L Lamp Barriers
2. Terminal Wiring
(1) The EB3L can be installed in any direction.
(2) Install the EB3L lamp barrier in a safe area (non-hazardous area)
in accordance with intrinsic safety ratings and parameters. To
avoid mechanical shocks, install the EB3L in an enclosure which
suppresses shocks.
(3) When installing or wiring the EB3L, prevent electromagnetic
and electrostatic inductions in the intrinsically safe circuit. Also
prevent the intrinsically safe circuits from contacting with another
intrinsically safe circuit and any other circuits.
Maintain at least 50 mm clearance, or provide a metallic separating
board between the intrinsically safe circuit and non-intrinsically
safety circuit. When providing a metallic separating board, make
sure that the board fits closely to the enclosure (top, bottom, and
both sides). Allowable clearance between the enclosure and board
is 1.5 mm at the maximum.
The clearance of 50 mm between the intrinsically safe circuit and
non-intrinsically safe circuit may not be sufficient when a motor
circuit or high-voltage circuit is installed nearby. In this case,
provide a wider clearance between the circuits referring to 6. (3)
“Minimum Parallel Distance between the Intrinsically Safe Circuit
and Other Circuits.”
(4) In order to prevent contact between intrinsically safe circuits and
non-intrinsically safe circuits, mount EB3L units with terminals
arranged in the same direction.
(1) Using a ø5.5 mm or smaller screw driver, tighten the terminal
screws (including unused terminal screws) to a torque of 0.6 to 1.0
N·m (recommended value).
(2) Make sure that IP20 is achieved when wiring. Use insulation tubes
on bare crimping terminals.
(3) To prevent disengaged wires from contacting with other intrinsically
safe circuits, bind together the wires of one intrinsically safe circuit.
(4) When the adjacent terminal is connected to another intrinsically
safe circuit, provide an insulation distance of at least 6 mm.
Intrinsically Safe Circuit
EB3L
EB3L
EB3L
EB3L
Non-intrinsically
Safe Circuit
EB3L
Intrinsically Safe Circuit
(5) Maintain at least 6 mm (or 3 mm according to IEC60079-11: 1999)
clearance between the terminal of intrinsically safe circuit and the
grounded metal part of a metal enclosure, and between the relay
terminal block of an intrinsically safe circuit and the grounded
metal part of a metal enclosure.
(6) For installing the EB3L, mount on a 35-mm-wide DIN rail or directly
on a panel using screws. The EB3L can be installed in any direction.
Make sure to install securely to withstand vibration. When mounting
on a DIN rail, push in the clamp completely. Use the BNL6 end clips
on both sides of the EB3L to prevent from moving sideways.
(7) Excessive extraneous noise may cause malfunction and damage
to the EB3L. When extraneous noise activates the voltage limiting
circuit (thyristor), remove the noise source and restore the power.
22
3. Signal Input
(1) Connect the EB3L to the switches or output equipment which have
a low leakage current (0.1 mA maximum).
(2) The EB3L is equipped with power supply. Do not apply external
power to the EB3L.
(3) When connecting the EB3L’s of connector model in parallel, make
sure that the same power supply is used. When using C1 and C2
terminals to supply power to outside equipment, maintain the
current at 50 mA maximum.
4. Power Voltage
(1) Do not apply an excessive power voltage, otherwise the EB3L may
be damaged.
(2) The EB3L of AC power type may operate at a low voltage (approx.
20V).
5. Pilot Lights, Illuminated Switches, and Buzzers in the
Hazardous Area
(1) EB3P and IPL1 units shown on page 14 can be used with the EB3L.
Buzzers cannot be connected in common wiring.
(2) Install the EB3P and IPL1 units on enclosures of IP20 or higher
protection. Use a metallic enclosure with magnesium content of
7.5% or less (steel and aluminum are acceptable).
(3) When wiring, make sure of correct polarities of the EB3P and IPL1.
(4) Certification mark is supplied with the units. Attach it on the visible
area of the EB3P or IPL1 (for Japan application).
(5) When connecting illuminated switches to the EB3L lamp barrier
and the EB3C relay barrier, a maximum of 16 channels can be
connected in common wiring.
EB3L Lamp Barrriers
Operating Instructions
6. Wiring for Intrinsic Safety
(1) The voltage applied on the general circuit connected to the nonintrinsically safe circuit terminals of the EB3L lamp barrier must
be 250V AC, 50/60Hz, or 250V DC at the maximum under any
conditions, including the voltage of the power line and the internal
circuit.
(2) When wiring, take into consideration the prevention of
electromagnetic and electrostatic charges on intrinsically safe
circuits. Also, prevent intrinsically safe circuits from contacting with
other circuits.
(3) The intrinsically safe circuits must be separated from nonintrinsically safe circuits. Contain intrinsically safe circuits in a
metallic tube or duct, or separate the intrinsically safe circuits
referring to the table at right.
Note: Cables with a magnetic shield, such as a metallic sheath,
prevent electromagnetic induction and electrostatic induction,
however, a non-magnetic shield prevents electrostatic induction
only. For non-magnetic shields, take a preventive measure
against electromagnetic induction.
Finely twisted pair cables prevent electromagnetic induction.
Adding shields to the twisted pair cables provides protection
against electrostatic induction.
Minimum Parallel Distance between the Intrinsically Safe Circuit and
Other Circuits (mm)
Voltage and Current
of Other Circuits
Over 100A
100A or less
50A or less
10A or less
Over 440V
2000
2000
2000
2000
440V or less
2000
600
600
600
220V or less
2000
600
600
500
110V or less
2000
600
500
300
60V or less
2000
500
300
150
(7) When wiring the intrinsically safe circuit, determine the distance to
satisfy the wiring parameters shown below. Note that parameters
are different between separate wiring and common wiring and
depend on the connected units, such as pilot lights, illuminated
pushbuttons, and buzzers.
a) Wiring capacitance Cw ≤ Co – Ci
Co: Maximum external capacitance of the EB3L
Ci: Internal capacitance of the connected unit
b) Wiring inductance Lw ≤ Lo – Li
Lo: Maximum external inductance of the EB3L
Li: Internal inductance of the connected unit
c) Wiring resistance ≤ Rw
Rw: Allowable wiring resistance
d) Allowable wiring distance D (km) is the smallest value of those
calculated from the capacitance, inductance, and resistance.
D ≤ Cw/C C (nF/km): Capacitance of cable per km
D ≤ Lw/L L (mH/km):
Inductance of cable per km
D ≤ Rw/2R R (Ω/km): Resistance of cable per km
Note: For the details of wiring the intrinsically safe circuits, refer to a
relevant test guideline for explosion-proof electric equipment in
each country.
(4) When identifying intrinsically safe circuits by color, use light blue
terminal blocks and cables.
(5) When using two or more EB3L’s to set up one intrinsically safe
circuit in the common wiring configuration, interconnect two
neutral terminals (N1 through N10) on each EB3L between adjacent
EB3L’s in parallel.
(6) Make sure that the power of the EB3L, pilot lights, and other
connected units are turned off before starting inspection or
replacement.
Safety Precautions
• Do not use the EB3C Relay Barrier and EB3L Lamp Barrier for other than explosion protection purposes.
• Read the user’s manual to make sure of correct operation before starting installation, wiring, operation, maintenance, and inspection of the EB3C
Relay Barrier and EB3L Lamp Barrier.
23
EB3N
Barriers
EB3N Safety
Safety Relay
Relay Barriers
Build a safety system in an explosive atmosphere.
Safety relay barrier
Switch (EB9Z-A)
Switch (EB9Z-A1)
Explosion
Protection
[Exia] II C
Exia II CT6
Exia II BT6
Safety
Performance
Performance level e
Category 4
• Ensures explosion protection safety and machine safety in an explosive
atmosphere.
• Machine safety system can be built in compliance with ISO13849-1 Category
4, Performance level e.
• Safety input devices applicable in any explosive gas and hazardous areas are
available.
• Available with auxiliary inputs (5 points) used to monitor the operating status
of safety input devices.
• A wide variety of Japan TIIS-rated emergency stop switches and interlock
switches are available.
• Global usage
Explosion protection: Japan (TIIS), USA (UL), Europe (ATEX),
China (CQST),IEC Ex
Machine safety:
TÜV Rheinland
• No grounding required.
IEC Ex
Safety Relay Barriers
Safety Input Points
Safety Output
Points
Auxiliary Input Points
(Note 1)
Auxiliary Output Points
(Relay Output)
2
2NO
Without
Without
2
2NO
5 (1 common)
5NO (1 common)
Reset (Start)
(Note 2, Note 3)
Auto reset (Auto start)
Manual reset (Manual start)
Auto reset (Auto start)
Manual reset (Manual start)
Part No.
EB3N-A2ND
EB3N-M2ND
EB3N-A2R5D
EB3N-M2R5D
Note 1: A maximum of five monitor contacts from safety input devices can be connected to the auxiliary input terminals. In addition, non-safety input devices can also be connected to the
auxiliary input terminals.
Note 2: On auto reset (auto start) models, when the safety condition is met (two safety inputs are both on), safety outputs are turned on automatically.
Connect the reset (start) input terminals Y1 and Y2 together except for the following cases:
When connecting a contactor or force guided relay to the safety output of the EB3N, connect the NC contacts of the contactor or force guided relay to the reset (start) input terminals
Y1 and Y2 of the EB3N for use as a backcheck input signal.
Note 3: On manual reset (manual start) models, while the safety condition is met (two safety inputs are both on), safety outputs are turned on at the falling edge of the reset switch (start
switch) signal (OFF ON OFF) (start off check).
Manual reset (manual start) models have a monitoring function of reset switch contacts (detection of welded contacts). Use NO contacts of a momentary switch for the reset (start)
input. When connecting a contactor or force guided relay to the safety output of the EB3N, connect the NC contacts of the contactor or force guided relay to the reset (start) input
terminals Y1 and Y2 of the EB3N for use as a backcheck input signal.
Selection Guide
1. Selecting the reset (start) function
Auto reset (auto start):
Select this model when connecting safety control devices, such as safety relay modules or safety controllers, to the EB3N safety outputs to set up a safety
system, using the reset (start) function of the safety control device.
Select this model when connecting contactors or force guided relays to the EB3N safety outputs to set up a safety system, and a risk assessment on the entire
system has not found any safety problem in using auto reset (auto start).
Manual reset (manual start): Select this model when connecting contactors or force guided relays to the EB3N safety outputs to set up a safety system, and a risk assessment on the entire
system has found that manual reset (manual start) is necessary.
2. Selecting the auxiliary outputs
Without auxiliary outputs: Select this model when the operating status of safety input devices are not monitored.
With auxiliary outputs: Select this model when the operating status of safety input devices are monitored or when non-safety input devices are also connected.
General Specifications
Explosion-Protection Specifications
Rated Power Voltage
Power Voltage Range
Operating Temperature
Operating Humidity
Power
Consumption
Safety
Output
Auxiliary
Output
Without auxiliary output
With auxiliary output
13-14,
Contacts
23-24
Resistive
Rated Load
Inductive
Turn on
Response
(rated voltage) Turn off
Contacts
A* - C1
Rated Load
Resistive
Response
(rated voltage)
Turn on
Turn off
Mounting
*: Channel Nos. 1 to 5
24
24V DC
20.4 to 26.4V DC
–20 to +60°C (no freezing)
UL: –20 to +40°C
(no freezing)
45 to 85% RH
(no condensation)
5.5W maximum
7.0W maximum
2NO
30V DC, 1A
DC-13, 24V, 1A
100 ms maximum
20 ms maximum
5NO/1 common
24V DC, 3A,
common terminal 5A max.
15 ms maximum
10 ms maximum
DIN rail or panel mounting
Explosion Protection
Non-intrinsically Safe Circuit Maximum Voltage
(Um)
Intrinsically Safe Circuit Maximum Voltage (Uo)
Intrinsically Safe Circuit Maximum Current (Io)
Intrinsically Safe Circuit Maximum Power (Po)
Intrinsically Safe Circuit Allowable Capacitance (Co)
[Exia] II C
250V (UL: 125V)
13.2V
227.2 mA
750 mW
0.49 µF (TIIS: 0.28 μF)
0.60 mH
Intrinsically Safe Circuit Allowable Inductance (Lo)
(TIIS: 0.56 mH)
Safety circuit
(Note 1)
Intrinsically Safe Circuit
Wiring Resistance (Rw)
Auxiliary circuit
(Note 2)
Note 1: 10Ω maximum (500m maximum using a 1.25 mm2 cable)
Note 2: 600/(N+1)Ω maximum, where N = the number of common channels
Safety Specifications
Category
4
Performance Level (PL)
e
Mean Time to Dangerous Failure (MTTFd)
100 years
Diagnostic Range
99% minimum
Calculation conditions for MTTFd
tcycle: Mean operation cycle = 1 hour
hop: Mean operation hours per day = 24 hours
dop: Mean operation days per year = 365 days
Note: When tcycle is shorter than 1 hour, MTTFd will decrease.
EB3N Safety Relay Barrriers
Certification No.
Certification
Organization
Explosion Protection
Certification No.
Safety Relay Barriers [Exia] II C
Switch (EB9Z-A)
[Exia] II CT6
Switch (EB9Z-A1)
[Exia] II BT6
[Exia] II C, [Exia D]
II (1) G [Exia] II C
II (1) D [Exia D]
[Exia] II C
Class I, Zone 0, [AExia] II C
Class I, II, III, Div. 1, Grps A, B, C, D, E, F and G
TIIS
PTB
CQST
UL
TC18753
TC15758
T15961
IEC Ex PTB 10.0015
PTB 09 ATEX 2046
CNEx 11.0038
E234997
Dimensions
Terminal Functions
EB3N-A2ND
EB3N-M2ND
M3
24V DC
110.5
M3
Y1-Y2
77.5
11-12
21-22
N1, N2
P*-N3
13-14
23-24
A*-C1
75.0
75.0
65.0
EB3N-A2R5D
EB3N-M2R5D
Mounting Hole Layout
*: 1 to 5
2-M4 tapped or
2-ø4.5 drilled holes
65
2-M4 tapped or
2-ø4.5 drilled holes
EB3N-A2R5D
EB3N-M2R5D
65
EB3N-A2ND
EB3N-M2ND
Power
Reset input
(Start input)
Safety input 1
Safety input 2
Signal ground
Auxiliary input
Safety output 1
Safety output 2
Auxiliary output
97
51
EB3N System Configuration Examples
1:1 connection with a safety input device, compliant with Category 4
Hazardous Area
Safety Input Device
Non-hazardous Area
EB3N-A2ND
Barrier Safety Output
Safety Control Device
Safety Output
Safety Contactor
• A safety relay module or safety controller is used
to set up a safety circuit, using the reset (start)
function of the safety relay module or safety
controller.
Backcheck Input
Reset (Start) Input
Safety Input Device
EB3N-M2ND
Barrier Safety Output
• The reset (start) function is used to set up a
safety circuit, without using a safety relay module
or safety controller.
Safety Contactor
Backcheck Input
Reset (Start) Input
Connection with multiple safety input devices, capable of monitoring up to 5 contact operations, compliant with Category 3
For monitoring operating statuses of safety input devices located in a non-hazardous area
Hazardous Area
Non-hazardous Area
Safety Control Device
Safety Output
Barrier Safety Output
EB3N-A2R5D
Safety Input Devices
Connected in Series
Backcheck Input
Safety Contactor
• A safety relay module or safety controller is used
to set up a safety circuit, using the reset (start)
function of the safety relay module or safety
controller.
PLC
…
Barrier Safety Output
Safety Input Devices
Connected in Series
Reset (Start) Input
Auxiliary Output
(Monitor Output)
Monitor
Safety Contactor
EB3N-M2R5D
Backcheck Input
Reset (Start) Input
…
Monitor
• The manual reset (manual start) function of the
EB3N is used to set up a safety circuit, without
using a safety control device.
PLC
Auxiliary Output
(Monitor Output)
25
EB3N Safety Relay Barrriers
Installing a reset switch in a hazardous area, using auxiliary input and output
Hazardous Area
Non-hazardous Area
Barrier Safety Output
Safety Input Devices
Safety Control Device
…
Safety Output
Safety Contactor
EB3N-A2R5D
Reset (Start) Switch
Reset (Start) Output
Backcheck Input
PLC
Other Input Device
Other Output
Barrier Safety Output
Safety Input Devices
Safety Contactor
EB3N-M2R5D
Reset (Start) Switch
Backcheck Input
PLC
Reset (Start) Input
Other Input Device
Other Output
Safety Input Devices Connectable to Safety Input Terminals (Examples)
Emergency stop switch: (Non-illuminated) XW1E-BV402MFRH, XN4E-BL412MRH
Safety switch:
HS6B-02B05, HS1B-02R
Operating Instructions
Notes for Operation
1. Do not disassemble, repair, or modify the EB3N safety relay barrier,
otherwise the safety characteristics may be impaired.
2. Use the EB3N within its specification values.
3. The EB3N can be mounted in any direction.
4. Mount the EB3N on a 35-mm-wide DIN rail or directly on a panel surface
using screws. When mounting on a DIN rail, push in the clamp and use end
clips to secure the EB3N. When mounting on a panel surface, tighten the
screws firmly.
5. Excessive noise may cause malfunction or damage to the EB3N. When the
internal voltage limiting circuit (thyristor) has shut down the power due to
noise, remove the cause of the noise before powering up again.
6. The internal power circuit contains an electronic fuse to suppress
overcurrents. When the electronic fuse has tripped, shut down the power,
remove the cause of the overcurrent before powering up again.
7. Use crimping terminals with insulation sheath for wiring. Tighten the terminal
screws, including unused terminal screws, to a recommended tightening
torque of 0.6 to N·m using a screwdriver of ø5.5 mm in diameter.
8. Before inspecting or replacing the EB3N, turn off the power.
Notes for Machine Safety
1. Operate the safety input device to check the EB3N functionality everyday.
2. For safety input devices, such as safety switches or emergency stop
switches, connected to the EB3N, use safety standard-compliant devices
with direct opening action and 2NC contacts.
3. Do not use the auxiliary input as a safety input.
4. For safety control devices connected with the EB3N, use machine safety
standard-compliant devices with a disparity detection function.
5. Use safety inputs and safety outputs in a circuit configuration compliant
with safety requirements.
6. To calculate the safety distance, take into consideration the response time
of all devices comprising the system, such as the EB3N and safety devices
connected to the EB3N.
7. Separate the input and output wiring from power lines and motor lines.
8. When using multiple EB3N safety relay barriers, do not connect one switch
to more than one EB3N. Use separate switches for each EB3N.
9. To ensure EMC, use shielded cables for safety inputs and auxiliary inputs.
Connect the shield to the FG of the control panel on which the EB3N is
mounted.
10. For protection against overcurrents, connect an IEC60127-2-compliant 2A
fast-blow fuse (5 × 20 mm).
11. Evaluate the ISO 13849-1 category and performance level in consideration
of the entire system.
Notes for Explosion Protection Safety
1. Install the EB3N in an enclosure capable of protecting against mechanical
shocks at a hazardous location in accordance with intrinsic safety ratings
and parameters.
2. Install and wire the EB3N so that the EB3N is not subject to electromagnetic
and electrostatic induction and does not contact with other circuits.
For example, keep a minimum spacing of 50 mm between intrinsically safe
and non-intrinsically safe circuits, or provide a metallic separating board
between the intrinsically safe circuit and non-intrinsically safe circuit. When
providing a metallic separating board, make sure that the board fits closely
to the enclosure (top, bottom, and both sides). Allowable clearance between
the board and the enclosure is 1.5 mm at the maximum.
When a motor circuit or high-voltage circuit is installed nearby, keep a wider
spacing than 50 mm between intrinsically safe and non-intrinsically safe
circuits.
3. Keep a minimum spacing of 3 mm between the terminal or relay terminal
block of the intrinsically safe circuit and the grounded metal parts of the
metal enclosure.
4. Connect the terminals so that IP20 is ensured.
5. To prevent disengaged wires from contacting with other intrinsically safe
circuits, bind together the end of wires.
6. Make sure that the voltage of the power supply for the devices connected
to the non-intrinsically safe circuit or the internal voltage of such devices
does not exceed 250V AC/DC 50/60 Hz or 250V DC under any normal and
abnormal conditions.
7. Make sure that the wiring of intrinsically safe circuits does not contact
with other circuits or is not subject to electromagnetic and electrostatic
inductions, otherwise explosion protection is not ensured.
8. When identifying intrinsically safe circuits by color, use light blue terminal
blocks and cables.
9. When wiring the intrinsically safe circuit, determine the distance to satisfy
the wiring parameters shown below.
a) Wiring capacitance Cw ≤ Co – Ci
Co: Intrinsically safe circuit allowable capacitance
Ci: Internal capacitance of switches
b) Wiring inductance Lw ≤ Lo – Li
Lo: Intrinsically safe circuit allowable inductance
Li: Internal inductance of switches
c) Wiring resistance ≤ Rw
Rw: Allowable wiring resistance
Switches in the Hazardous Area
1. A switch contains the switch contact, enclosure, and internal wiring. A
switch contact refers to an ordinary switching device which consists of
contacts only.
2. When the switch has internal wiring or lead wire, make sure that the values
of internal capacitance (Ci) and inductance (Li) are within the certified
values.
3. Enclose the bare live part of the switch contact in an enclosure of IP20 or
higher protection.
4. Depending on the explosion-protection specifications of TIIS, the exposed
area of plastic switch operator, when installed in Japan, is limited as
follows:
Certification
Explosion Protection
Exposed Area
TC15758
TC15961
26
Exia II CT6
Exia II BT6
20 cm2 maximum
100 cm2 maximum
EB3N Safety Relay Barrriers
27
www.idec.com
Head Office
6-64, Nishi-Miyahara-2-Chome, Yodogawa-ku, Osaka 532-0004, Japan
USA
Germany
Singapore
Thailand
Australia
Taiwan
IDEC Corporation
APEM GmbH
IDEC Izumi Asia Pte. Ltd.
IDEC Asia (Thailand) Co., Ltd
IDEC Australia Pty. Ltd.
IDEC Taiwan Corporation
Tel: +1-408-747-0550
Tel: +49-40-25 30 54 - 0
Tel: +65-6746-1155
Tel: +66-2-392-9765
Tel: +61-3-8523-5900
Tel: +886-2-2698-3929
opencontact@idec.com
service@eu.idec.com
info@sg.idec.com
sales@th.idec.com
sales@au.idec.com
service@tw.idec.com
Specifications and other descriptions in this brochure are subject to change without notice.
Information in this catalog is current as of November, 2018.
2018 IDEC Corporation, All Rights Reserved.
EP1597-2
Hong Kong
China/Shanghai
China/Shenzhen
China/Beijing
Japan
IDEC Izumi (H.K.) Co., Ltd.
IDEC (Shanghai) Corporation
IDEC (Shenzhen) Corporation
IDEC (Beijing) Corporation
IDEC Corporation
Tel: +852-2803-8989
Tel: +86-21-6135-1515
Tel: +86-755-8356-2977
Tel: +86-10-6581-6131
Tel: +81-6-6398-2527
info@hk.idec.com
idec@cn.idec.com
idec@cn.idec.com
idec@cn.idec.com
marketing@idec.co.jp