VBA-240-ALA

VBA-240-ALA

  • 厂商:

    MUELLERELECTRIC

  • 封装:

  • 描述:

    电压检测 AC 240VAC

  • 数据手册
  • 价格&库存
VBA-240-ALA 数据手册
STYLE "A" OPERATION With normal operating voltage applied, the internal relay will energize (PICK-UP). When the voltage falls outside the preset Over/Under trip points for longer than the release delay, the relay will de-energize (DROP-OUT). When line conditions return to normal, the VBA Series automatically resets and the internal relay energizes. The HYSTERESIS in each unit on the Under and Over limits provides a differential between the PICK-UP and DROP-OUT trip points. VBA Series The VBA Series offers protection to SINGLE PHASE equipment that is required to operate between two voltage limits. Supply voltage is monitored for a preselected UNDER and OVER voltage limit. STYLE "N" WIRING E55826 Style A only Single Phase Voltage Band Monitor POWER REQUIRED Models Up To 110 VDC: 3 Watts, Max. Models Up To 300 VAC: 5 VA, Max. OUTPUT RATING Style A Style N DPDT, 5A @ 240 VAC, Resistive; 211 VA @ 240 VAC SPDT, 10A @ 240 VAC, Resistive; 180 VA, @ 120 VAC RESPONSE TIMES Operate Release 50 mSEC (approx.) (500 mSEC on 12 VDC units) 0.5 SEC (approx.) TEMPERATURE RATING Operate Storage 32° to +131°F (0° to +55°C) -49° to 185°F (-45° to +85°C) WEIGHT 5 oz. PHASE VOLTAGE MONITORS SPECIFICATIONS RB-08 or PF083A MODEL NOMINAL PICK-UP UNDER PICK-UP OVER HYSTERESIS VOLTAGE VOLTAGE VOLTAGE VOLTAGE VOLTAGE VBA-24-A*A 24 VAC VBA-120-A*A 120 VAC VBA-208-A*A 208 VAC VBA-240-A*A 240 VAC VBA-12-D*A 12 VDC VBA-24-D*A 24 VDC VBA-28-D*A 28 VDC VBA-48-D*A 48 VDC VBA-110-D*A 110 VDC VBA-24-AFN 24 VAC VBA-120-AFN 120 VAC VBA-208-AFN 208 VAC VBA-220-AFN 208/240 VAC VBA-230-AFN 230 VAC VBA-240-AFN 240 VAC *Adjustments - F = Fixed K = Knob L = Locknut Diversified Electronics 19-24 90-120 185-208 200-240 10-12 19-24 22-28 38-48 85-110 21.6 108 187 198 207 216 24-29 120-150 208-240 240-270 12-15 24-29 28-34 48-58 110-135 26.4 132 229 242 253 264 800.727.5646 atcdiversified.com 2 5 8 10 1 1 1 2 5 0 0 0 0 0 0 167 Applications PHASE VOLTAGE MONITORS APPLICATION NOTES – WIRING DIAGRAMS SLA-XXX-ALE SLD-XXX-ALE SLE-XXX-ALE SLH-XXX-ALE SLM-XXX-ALE PBE-XXX-ASE (Delta Connection) PBE-XXX/XXX-ALE 168 Diversified Electronics 800.727.5646 atcdiversified.com Applications APPLICATION NOTES – WIRING DIAGRAMS PHASE VOLTAGE MONITORS SLA-XXX-AFN PBE-XXX-ASE Diversified Electronics 800.727.5646 atcdiversified.com 169
VBA-240-ALA 价格&库存

很抱歉,暂时无法提供与“VBA-240-ALA”相匹配的价格&库存,您可以联系我们找货

免费人工找货