Power Products
Wireless Charging Receiver Coil, Low
Profile
Features
•
•
•
•
•
•
•
Wireless Charging Receiver Coil
12uH inductance
Compact 20.0mm diameter
Thin 0.8mm profile
High permeability shielding
Industrial operating temperature -25°C to +85°C
RoHS / RoHS2 Compliant
RCC-2020-RX-NL
Applications
•
•
•
•
•
•
IoT, Wearables
Portable Electronics
Consumer Electronics
Smart Phone Charging
Portable Audio
Industrial Electronics
Electrical Specifications
Part Number
RCC-2020-RX-NL
Inductance
12uH ±10%
DC Resistance
275mΩ ±20%
Q
20 ±30%
Test Conditions: Ambient Temperature: 25 ±10˚C, RH: 60% ±20%.
Maximum Ratings
Item
Operating Temperature Range
Storage Temperature Range
Value
-25° to 85°C, RH ≤ 90%
-25° to 85°C, RH ≤ 70%
Mechanical Specifications
REF
Spec
A
20.0
B
20.0
C
18.2
D
18.2
E
6.5
F
6.5
G
15.0 ±2
H
3.0 ±1
I
1.0
Dimensions are in mm
Tolerances are ±0.2mm, unless otherwise specified
Wave Soldering Profile: Not suitable for wave soldering
Manual Soldering: 350°C Max, 3secs
Packaging: Box, 100pcs MOQ
Number
of Coils
1
Wire
Diameter
0.2
RDI, Inc.
www.rdiusa.com
Number
of Turns
24
Inductance
12uH ±15%
+1-914-773-1000
333 N. Bedford Rd., Suite 135, Mount Kisco, NY 10549
Page 1 of 2
sales@rdiusa.com
Power Products
Wireless Charging Receiver Coil, Low
Profile
Notes
RCC-2020-RX-NL
1. The parts are manufactured in accordance with this specification. If other conditions and
specifications which are required for this specification, please contact RDI for more information.
2. RDI will supply the parts in accordance with this specification unless we receive a written request
to modify prior to an order placement.
3. In no case shall RDI be liable for any product failure from in appropriate handling or operation of
the item beyond the scope of this specification.
4. When changing your production process, please notify RDI immediately.
5. RDI products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial
and Consumer Applications. RDI’s products are not specifically designed for Military, Aviation,
Aerospace, Life-dependent Medical applications or any application requiring high reliability where
component failure could result in loss of life and/or property. For applications requiring high
reliability and/or presenting an extreme operating environment, written consent and
authorization from RDI is required. Please contact RDI for more information.
6. All specifications and Marking will be subject to change without notice.
RDI, Inc.
www.rdiusa.com
+1-914-773-1000
333 N. Bedford Rd., Suite 135, Mount Kisco, NY 10549
Page 2 of 2
sales@rdiusa.com