SiT3822
220-625 MHz High Performance Differential VCXO
The Smart Timing Choice
The Smart Timing Choice
Features
Applications
■ Any frequency between 220 MHz and 625 MHz accurate to 6 decimal
places
■ Ideal for SONET, Video, Instrumentation, Satellite applications
■ Widest pull range options: ±25, ±50, ±100, ±150, ±200, ±400, ±800,
±1600 ppm
■ Telecom, networking, broadband
■ Superior pull range linearity of ≤ 1%, 10 times better than quartz
■ < 1ps RMS phase jitter (random) over 12 kHz to 20 MHz bandwidth
■ Industrial and extended commercial temperature ranges
■ Industry-standard packages: 3.2 mm x 2.5 mm, 5.0 mm x 3.2 mm and
7.0 mm x 5.0 mm
■ For frequencies higher than 220 MHz, refer to SiT3821 datasheet
Electrical Characteristics
Parameter and Conditions
Symbol
Min.
Typ.
Max.
Unit
Condition
LVPECL and LVDS, Common AC Characteristics
Output Frequency Range
Frequency Stability
f
F_stab
Operating Temperature Range
T_use
Start-up Time
Duty Cycle
T_start
DC
Pull Range
PR
Upper Control Voltage
VC_U
Lower Control Voltage
Linearity
Frequency Change Polarity
220
-10
–
–
625
+10
MHz
ppm
-25
–
+25
ppm
-50
–
+50
ppm
-40
-20
–
45
–
–
–
–
+85
+70
10
55
°C
°C
ms
%
Industrial
Extended Commercial
40
–
60
%
f = 420 to 500 MHz
±25, ±50, ±100, ±150,
±200, ±400, ±800, ±1600
f = 220 to 312.5 MHz and f = 525 to 625 MHz
See the last page for Absolute Pull Range, APR table
3
–
3.1
V
2.25
–
2.3
V
Vdd = 2.5V, Voltage at which maximum deviation is guaranteed
VC_L
0
–
0.1
V
Voltage at which maximum deviation is guaranteed
Lin
–
0.2
1
%
–
Control Voltage Bandwidth (-3dB)
ppm
For frequency coverage see last page
Inclusive of initial tolerance, operating temperature, rated power,
supply voltage and load change
V_BW
Positive Slope
Vdd = 3.3V, Voltage at which maximum deviation is guaranteed
–
–
8
–
kHz
Contact SiTime for 16 kHz bandwidth
1-year Aging
-1
–
+1
ppm
First year @25°C
10-year Aging
-5
–
+5
ppm
LVPECL, DC and AC Characteristics
Supply Voltage
Vdd
2.97
2.25
–
–
–
3.3
2.5
61
–
–
3.63
2.75
69
35
1
V
V
mA
mA
A
Current Consumption
OE Disable Supply Current
Output Disable Leakage Current
Idd
I_OE
I_leak
Maximum Output Current
I-driver
–
–
30
mA
VOH
Vdd-1.1
–
Vdd-0.7
V
See Figure 1
Output High Voltage
Output Low Voltage
Excluding Load Termination Current, Vdd = 3.3V or 2.5V
OE = GND
OE = GND
Maximum average current drawn from OUT+ or OUT-
VOL
Vdd-1.9
–
Vdd-1.5
V
See Figure 1
V_Swing
600
800
1000
mV
See Figure 1
Rise/Fall Time
Tr, Tf
100
300
500
ps
20% to 80%
OE Enable/Disable Time
RMS Period Jitter
T_oe
T_jitt
RMS Phase Jitter (random)
T_phj
–
–
–
–
–
–
1
1
1
0.5
105
1.7
1.7
1.7
0.75
ns
ps
ps
ps
ps
f = 220 MHz - For other frequencies, T_oe = 100ns + 3 period
f = 100 MHz, Vdd = 3.3V or 2.5V
f = 156.25 MHz, Vdd = 3.3V or 2.5V
f = 212.5 MHz, Vdd = 3.3V or 2.5V
f = 156.25 MHz, Integration bandwidth = 12 kHz to 20 MHz, all
Vdds
Pk-Pk Output Voltage Swing
SiTime Corporation
Rev. 1.3
990 Almanor Avenue
Sunnyvale, CA 94085
(408) 328-4400
www.sitime.com
Revised October 6, 2014
SiT3822
220-625 MHz High Performance Differential VCXO
The Smart Timing Choice
The Smart Timing Choice
Electrical Characteristics
Parameter and Conditions
Symbol
Min.
Typ.
Max.
Unit
Condition
Vdd
2.97
3.3
3.63
2.25
2.5
2.75
V
Idd
–
47
55
mA
OE Disable Current
I_OE
–
–
35
mA
OE = Vdd
Output Disable Leakage Current
I_leak
–
–
1
A
OE = Vdd
VOD
Tr, Tf
200
–
1.125
–
360
350
–
1.2
–
495
500
50
1.375
50
380
mV
mV
V
mV
ps
See Figure 4
See Figure 4
See Figure 4
See Figure 4
20% to 80%
T_oe
T_jitt
–
–
–
1.2
105
1.7
ns
ps
f = 220 MHz - For other frequencies, T_oe = 100ns + 3 period
f = 100 MHz, Vdd = 3.3V or 2.5V
–
1.2
1.7
ps
f = 156.25 MHz, Vdd = 3.3V or 2.5V
–
1.2
1.7
ps
f = 212.5 MHz, Vdd = 3.3V or 2.5V
–
0.5
0.75
ps
f = 156.25 MHz, Integration bandwidth = 12 kHz to 20 MHz, all
Vdds
LVDS, DC, and AC Characteristics
Supply Voltage
Current Consumption
Differential Output Voltage
VOD Magnitude Change
Offset Voltage
VOS Magnitude Change
Rise/Fall Time
VOD
VOS
VOS
OE Enable/Disable Time
RMS Period Jitter
RMS Phase Jitter (random)
T_phj
V
Excluding Load Termination Current, Vdd = 3.3V or 2.5V
Pin Description
Pin
Map
1
VIN
Input
Control Voltage
NC
Input
No Connect (only for 3225 package)
OE
Input
H or Open: specified frequency output
L: output is high impedance (only for 7050 and 5032 packages)
2
Functionality
Top View
3
GND
Power
VDD Power Supply Ground
4
OUT+
Output
Oscillator Output
5
OUT-
Output
Complementary Oscillator Output
6
VDD
Power
Power Supply Voltage
VIN
1
6
VDD
NC/OE
2
5
OUT-
GND
3
4
OUT+
Absolute Maximum
Attempted operation outside the absolute maximum ratings may cause permanent damage to the part. Actual performance of
the IC is only guaranteed within the operational specifications, not at absolute maximum ratings.
Min.
Max.
Unit
Storage Temperature
Parameter
-65
150
°C
VDD
-0.5
4
V
–
2000
V
–
260
°C
1,000+
–
years
Electrostatic Discharge
Soldering Temperature (follow standard Pb free soldering guidelines)
Program Retention over -40 to 125°C, Process, VDD (0 to 3.65V)
Thermal Consideration
Package
JA, 4 Layer Board
(°C/W)
JC, Bottom
(°C/W)
7050, 6-pin
142
27
5032, 6-pin
97
20
3225, 6-pin
109
20
Environmental Compliance
Parameter
Condition/Test Method
Mechanical Shock
MIL-STD-883F, Method 2002
Mechanical Vibration
MIL-STD-883F, Method 2007
Temperature Cycle
JESD22, Method A104
Solderability
MIL-STD-883F, Method 2003
Moisture Sensitivity Level
MSL1 @ 260°C
Rev. 1.3
Page 2 of 7
www.sitime.com
SiT3822
220-625 MHz High Performance Differential VCXO
The Smart Timing Choice
The Smart Timing Choice
Termination Diagrams
LVPECL:
VDD
Z 0 = 50
OUT+
D+
Receiver Device
D rive D ev ice
Z0 = 5 0
OUT-
D50
50
V T T = V D D – 2.0 V
Figure 1. LVPECL Typical Termination
VDD
R1 = 100 to 150
OUT+
100 nF
Z0 = 50
D+
Receiver Device
Drive Device
100 nF
Z0 = 50
OUTR1
R1
D50
50
VTT
Figure 2. LVPECL AC Coupled Termination
VDD = 3.3V => R1 = R3 = 133 and
R2 = R4 = 82
VDD = 2.5V => R1 = R3 = 250 and
R2 = R4 = 62.5
VDD
R1
VDD
OUT+
R3
Z0 = 50
D+
Receiver
Device
Drive Device
OUT-
Z0 = 50
DR2
R4
Figure 3. LVPECL with Thevenin Typical Termination
Rev. 1.3
Page 3 of 7
www.sitime.com
SiT3822
220-625 MHz High Performance Differential VCXO
The Smart Timing Choice
The Smart Timing Choice
LVDS:
VDD
OUT+
Z0 = 50
D+
100
Drive Device
OUT-
Z0 = 50
Receiver Device
D-
Figure 4. LVDS Single Termination (Load Terminated)
Rev. 1.3
Page 4 of 7
www.sitime.com
SiT3822
220-625 MHz High Performance Differential VCXO
The Smart Timing Choice
The Smart Timing Choice
Dimensions and Patterns
Package Size – Dimensions (Unit: mm)[1]
Recommended Land Pattern (Unit: mm)[2]
3.2 x 2.5x 0.75 mm
3.2±0.05
2.20
#4
#2
#3
#4
#6
0.9
#1
#3
#2
1.00
0.7
YXXXX
2 .2 5
#5
1.6
#5
2.5±0.05
#6
#1
0.6
0.75±0.05
0 .6 5
1 .0 5
5.0 x 3.2 x 0.75 mm
#5
#4
#2
#3
#4
#5
#6
1.20
#6
YXXXX
#1
#3
#2
#1
0.75±0.05
7.0 x 5.0 x 0.90 mm
5.08
7.0±0.10
#6
#3
#3
#2
#1
1.60
#2
#5
1.10
YXXXX
#1
#4
3.80
#4
2.60
#5
5.0±0.10
#6
5.08
0.90 ±0.10
1.40
1.60
1. Top Marking: Y denotes manufacturing origin and XXXX denotes manufacturing lot number. The value of “Y” will depend on the assembly location of the device.
2. A capacitor of value 0.1 F between Vdd and GND is recommended.
Rev. 1.3
Page 5 of 7
www.sitime.com
SiT3822
220-625 MHz High Performance Differential VCXO
The Smart Timing Choice
The Smart Timing Choice
Ordering Information
SiT3822AC-1C2-33NH220.123456T
Packaging:
Part Family
“T”, “Y”, “X”, “D”, “E” or “G”
Refer to table below for packing
method
Leave Blank for Bulk
“SiT3822”
Revision Letter
“A” is the revision of Silicon
Frequency
220.000000 MHz to
625.000000 MHz
Temperature Range
“C” Extended Commercial, -20 to 70°C
“I” Industrial, -40 to 85°C
Pull Range Options
“M” for ±25 ppm
“B” for ±50 ppm
“E” for ±100 ppm
“G” for ±150 ppm
“H” for ±200 ppm
“X” for ±400 ppm
“Y” for ±800 ppm
“Z” for ±1600 ppm
Signalling Type
“1” = LVPECL
“2” = LVDS
Package Size
“B” 3.2 x 2.5 mm
“C” 5.0 x 3.2 mm
“D” 7.0 x 5.0 mm
Feature Pin
“E” for Output Enable
(only available for 7.0 x 5.0
and 5.0 x 3.0 packages)
Frequency Stability
“F” for ±10 ppm
“2” for ±25 ppm
“3” for ±50 ppm
“N” for No Connect
(for 3.2 x 2.5 package)
Voltage Supply
“25” for 2.5 V ±10%
“33” for 3.3 V ±10%
Frequencies Not Supported
Range 1: From 209.000001 MHz to 210.999999 MHz
Range 2: From 251.000001 MHz to 263.999999 MHz
Range 3: From 314.000001 MHz to 422.999999 MHz
Range 4: From 502.000001 MHz to 527.999999 MHz
APR Definition
Absolute pull range (APR) = Nominal pull range (PR) - frequency stability (F_stab) - Aging (F_aging)
APR Table
Frequency Stability
Nominal Pull Range
± 10
± 25
±50
APR (ppm)
± 25
± 10
—
± 50
± 35
± 20
—
—
± 100
± 85
± 70
± 45
± 150
± 135
± 120
± 95
± 200
± 185
± 170
± 145
± 400
± 385
± 370
± 345
± 800
± 785
± 770
± 745
± 1600
± 1585
± 1570
± 1545
Ordering Codes for Supported Tape & Reel Packing Method
Device Size
8 mm T&R
(3ku)
8 mm T&R
(1ku)
8 mm T&R
(250u)
12 mm T&R
(3ku)
12 mm T&R
(1ku)
12 mm T&R
(250u)
16 mm T&R
(3ku)
16 mm T&R
(1ku)
16 mm T&R
(250u)
7.0 x 5.0 mm
–
–
–
–
–
–
T
Y
X
5.0 x 3.2 mm
–
–
–
T
Y
X
–
–
–
3.2 x 2.5 mm
D
E
G
T
Y
X
–
–
–
Rev. 1.3
Page 6 of 7
www.sitime.com
SiT3822
220-625 MHz High Performance Differential VCXO
The Smart Timing Choice
The Smart Timing Choice
Revision History
Version
Release Date
1.0
6/12/12
Original
Change Summary
1.1
6/6/14
Included 3225 package
1.2
9/12/14
Corrected the “Frequencies Not Supported” section
1.3
10/6/14
Modified Thermal Consideration values
© SiTime Corporation 2014. The information contained herein is subject to change at any time without notice. SiTime assumes no responsibility or liability for any loss, damage or defect of a
Product which is caused in whole or in part by (i) use of any circuitry other than circuitry embodied in a SiTime product, (ii) misuse or abuse including static discharge, neglect or accident, (iii)
unauthorized modification or repairs which have been soldered or altered during assembly and are not capable of being tested by SiTime under its normal test conditions, or (iv) improper
installation, storage, handling, warehousing or transportation, or (v) being subjected to unusual physical, thermal, or electrical stress.
Disclaimer: SiTime makes no warranty of any kind, express or implied, with regard to this material, and specifically disclaims any and all express or implied warranties, either in fact or by
operation of law, statutory or otherwise, including the implied warranties of merchantability and fitness for use or a particular purpose, and any implied warranty arising from course of dealing or
usage of trade, as well as any common-law duties relating to accuracy or lack of negligence, with respect to this material, any SiTime product and any product documentation. Products sold by
SiTime are not suitable or intended to be used in a life support application or component, to operate nuclear facilities, or in other mission critical applications where human life may be involved
or at stake. All sales are made conditioned upon compliance with the critical uses policy set forth below.
CRITICAL USE EXCLUSION POLICY
BUYER AGREES NOT TO USE SITIME'S PRODUCTS FOR ANY APPLICATION OR IN ANY COMPONENTS USED IN LIFE SUPPORT DEVICES OR TO OPERATE NUCLEAR FACILITIES
OR FOR USE IN OTHER MISSION-CRITICAL APPLICATIONS OR COMPONENTS WHERE HUMAN LIFE OR PROPERTY MAY BE AT STAKE.
SiTime owns all rights, title and interest to the intellectual property related to SiTime's products, including any software, firmware, copyright, patent, or trademark. The sale of SiTime products
does not convey or imply any license under patent or other rights. SiTime retains the copyright and trademark rights in all documents, catalogs and plans supplied pursuant to or ancillary to the
sale of products or services by SiTime. Unless otherwise agreed to in writing by SiTime, any reproduction, modification, translation, compilation, or representation of this material shall be strictly
prohibited.
Rev. 1.3
Page 7 of 7
www.sitime.com