Type FSF/FSF-P
Fast Acting Glass Tube Fuse
3.6 x 10 mm
www.optifuse.com
(619) 593-5050
Agency Standards and Listings:
Physical Specifications:
Fuse Type: 3.6 Ø x 10mm
Materials:
Ceramic Body / Nickel Brass Caps
Lead Wire:
Diameter Ø 0.6mm – 8A and less
Diameter Ø 0.8mm – 10A to 15A
Electrical Characteristics
Rated
100%
200%
Current
Min
Max
100mA ~ 15A
4h
60s
Interrupting Ratings
50A at 250V AC
Operating Temperatures
-55C to +125C
Dimensions: Inches [mm]
Note: All specifications subject to change without notice.
Cartridge
Part Number
FSF-100mA
FSF-125mA
FSF-150mA
FSF-160mA
FSF-200mA
FSF-250mA
FSF-300mA
FSF-315mA
FSF-350mA
FSF-375mA
FSF-400mA
FSF-500mA
FSF-600mA
FSF-630mA
FSF-750mA
FSF-800mA
FSF-1A
FSF-1.2A
FSF-1.25A
FSF-1.5A
FSF-1.6A
FSF-2A
FSF-2.25A
FSF-2.5A
FSF-3A
FSF-3.15A
FSF-3.5A
FSF-4A
FSF-5A
FSF-6A
FSF-6.3A
FSF-7A
FSF-8A
FSF-9A
FSF-10A
FSF-12A
FSF-15A
Axial Lead
Part Number
FSF-P-100mA
FSF-P-125mA
FSF-P-150mA
FSF-P-160mA
FSF-P-200mA
FSF-P-250mA
FSF-P-300mA
FSF-P-315mA
FSF-P-350mA
FSF-P-375mA
FSF-P-400mA
FSF-P-500mA
FSF-P-600mA
FSF-P-630mA
FSF-P-750mA
FSF-P-800mA
FSF-P-1A
FSF-P-1.2A
FSF-P-1.25A
FSF-P-1.5A
FSF-P-1.6A
FSF-P-2A
FSF-P-2.25A
FSF-P-2.5A
FSF-P-3A
FSF-P-3.15A
FSF-P-3.5A
FSF-P-4A
FSF-P-5A
FSF-P-6A
FSF-P-6.3A
FSF-P-7A
FSF-P-8A
FSF-P-9A
FSF-P-10A
FSF-P-12A
FSF-15A
Ampere
Rating
100mA
125mA
150mA
160mA
200mA
250mA
300mA
315mA
350mA
375mA
400mA
500mA
600mA
630mA
750mA
800mA
1A
1.2A
1.25A
1.5A
1.6A
2A
2.25A
2.5A
3A
3.15A
3.5A
4A
5A
6A
6.3A
7A
8A
9A
10A
12A
15A
I2 T
Reference
(A2 Sec.)
0.001375
0.001763
0.004396
0.004689
0.005861
0.01093
0.07196
0.08236
0.09546
0.11720
0.13890
0.09975
0.1354
0.1422
0.1956
0.2463
0.3606
0.5181
0.5728
0.8601
1.115
2.189
2.463
1.911
3.420
3.83
5.155
5.891
9.401
16.34
20.59
26.03
30.86
46.89
59.32
92.27
243.7
Rev B 12/2015 - Page: 1/2
Code: H01-01H
Type FSF/FSF-P
Fast Acting Glass Tube Fuse
3.6 x 10 mm
www.optifuse.com
(619) 593-5050
PART NUMBER FSF/FSF-P
TIME CURRENT CURVES
Warning:
-Operation beyond the specified maximum ratings or improper use may result in damage and possible electrical
arcing and/or flame.
-Fuses are intended for occasional overcurrent protection. Application for repeated overcurrent condition
and/or prolonged trip are not anticipated.
-Avoid contact of Fuse device with chemical solvent. Prolonged contact may damage the device performance.
Note: All specifications subject to change without notice.
Rev B 12/2015 - Page: 2/2
Code: H01-01H
很抱歉,暂时无法提供与“FSF-500MA”相匹配的价格&库存,您可以联系我们找货
免费人工找货