Type MOCB-12-V / MOCB-24-V
Modified Reset Circuit Breaker
Automotive Type II
Metal With Vertical Bracket
www.optifuse.com
(619) 593-5050
Specifications:
Modified Reset Type Circuit Breaker. Modified reset circuit breakers are devices that
are opened by over-current and remain open as long as the power is on to the affected
circuit or until load is removed
Voltage: 12V or 24V
Amperage: 10A, 15A, 20A, 25A, 30A, 35A, 40A, 50A
Terminals: Battery – Copper Plate (0.58”), Auxiliary – Zinc Plate (0.66”)
Conforms to American National Standard SAE J553
Cover Material: Metal
Operating Temperature: -10º F ~ 150º F
Storage Temperature: -20º F ~ 200º F
Current Rating:
Rating
100% ± 1.5%
135% ± 1.5%
200% ± 1.5%
Open Time
> 30 Min
< 30 Min
< 1 Min
Mechanical Dimensions: Inches [mm]
Warning:
-Operation beyond the specified maximum ratings or improper use may result in damage and possible electrical
arcing and/or flame.
-Device are intended for occasional overcurrent protection. Application for repeated overcurrent condition
and/or prolonged trip are not anticipated.
-Avoid contact of device with chemical solvent. Prolonged contact will damage the device performance.
Note: All specifications subject to change without notice.
Rev C 07/2012 - Page: 1/1
Code Y01-02D
很抱歉,暂时无法提供与“MOCB-24-V-10A”相匹配的价格&库存,您可以联系我们找货