Type MOCB2-PL3
Modified Reset Circuit Breaker
Automotive Type II
Plug-In Type
Specifications:
Modified Reset Type Circuit Breaker
Voltage: Up to 12V
Amperage: 5A, 6A, 8A, 10A, 15A, 20A, 25A, 30A
Conforms to American National Standard SAE J553
Operating Temperature: -20º C ~ 65º C
Storage Temperature: -30º C ~ 90º C
Current Rating:
Rating
100% ± 1.5%
135% ± 1.5%
200% ± 1.5%
Open Time
www.optifuse.com
Part Number
MOCB2-PL3-5A
MOCB2-PL3-6A
MOCB2-PL3-8A
MOCB2-PL3-10A
MOCB2-PL3-15A
MOCB2-PL3-20A
MOCB2-PL3-25A
MOCB2-PL3-30A
(619) 593-5050
Amperage
5A
6A
8A
10A
15A
20A
25A
30A
> 30 Min
< 30 Min
< 1 Min
Mechanical Dimensions: Inches [mm]
Warning:
-Operation beyond the specified maximum ratings or improper use may result in damage and possible electrical
arcing and/or flame.
-Device are intended for occasional overcurrent protection. Application for repeated overcurrent condition
and/or prolonged trip are not anticipated.
-Avoid contact of device with chemical solvent. Prolonged contact may damage the device performance.
Note: All specifications subject to change without notice.