Type TMR
Time Lag Micro Fuse
Radial Leaded – Long Leaded
Designed to Meet UL/CSA Specifications
www.optifuse.com
(619) 593-5050
Agency Standards and Listings:
Voltage: 250V
Material
Body: Thermoplastic UL94V0
Pin: Copper Alloy, Tin plated
Element: Silver Alloy
Interrupt Ratings: 50A @ 250 VAC
Electrical Characteristics:
Rated Current 1.0 In
2.0 In
Carry 60 sec Max
50mA~10A
TMR-xxA
TMR-xxA-T
for Loose Fuses, Bulk, in a bag
for Taped Fuses, in a box
Mechanical Dimensions: Inches [mm]
Warning:
Cartridge
Catalog
Number
TMR-50mA
TMR-60mA
TMR-63mA
TMR-80mA
TMR-100mA
TMR-125mA
TMR-160mA
TMR-200mA
TMR-250mA
TMR-300mA
TMR-315mA
TMR-400mA
TMR-500mA
TMR-600mA
TMR-630mA
TMR-700mA
TMR-800mA
TMR-1A
TMR-1.25A
TMR-1.5A
TMR-1.6A
TMR-2A
TMR-2.5A
TMR-3A
TMR-3.15A
TMR-3.5A
TMR-4A
TMR-5A
TMR-6.3A
TMR-7A
TMR-8A
TMR-10A
Ampere
Rating
50mA
60mA
63mA
80mA
100mA
125mA
160mA
200mA
250mA
300mA
315mA
400mA
500mA
600mA
630mA
700mA
800mA
1A
1.25A
1.5A
1.6A
2A
2.5A
3A
3.15A
3.5A
4A
5A
6.3A
7A
8A
10A
Voltage
Rating
I2T
250VAC
0.0056
0.0075
0.009
0.014
0.025
0.044
0.058
0.1
0.17
0.22
0.26
0.32
0.58
0.67
0.75
0.85
0.98
2.8
3.8
4.8
5.2
7.5
14
19
22
24
27
59
100
122
160
220
-Operation beyond the specified maximum ratings or improper use may result in damage and possible electrical arcing and/or flame.
-Micro Fuse device are intended for occasional overcurrent protection. Application for repeated overcurrent condition and/or prolonged trip are
not anticipated.
-Avoid contact of Micro Fuse device with chemical solvent. Prolonged contact will damage the device performance.
Note: All specifications subject to change without notice.