THEO-P173
Host-based V2X transceiver module
Data Sheet
Abstract
This technical data sheet describes the THEO-P173 Wi-Fi 802.11p
module designed for applications such as traffic safety, intelligent
traffic management and entertainment. This host-based module
includes an integrated MAC/LLC/Baseband processor and required
RF front-end components. The module can be connected to a host
processor through the USB interface.
www.u-blox.com
UBX-15023940 - R02
THEO-P173 - Data Sheet
Document Information
Title
THEO-P173
Subtitle
Host-based V2X transceiver module
Document type
Data Sheet
Document number
UBX-15023940
Revision and date
R02
Document status
Advance Information
30-Nov-2016
Document status explanation
Objective Specification
Document contains target values. Revised and supplementary data will be published later.
Advance Information
Document contains data based on early testing. Revised and supplementary data will be published later.
Early Production Information
Document contains data from product verification. Revised and supplementary data may be published later.
Production Information
Document contains the final product specification.
This document applies to the following products:
Product name
Type number
Firmware version
PCN / IN reference
THEO-P173
THEO-P173-01A-00
-
N/A
u-blox reserves all rights to this document and the information contained herein. Products, names, logos and designs described herein may in
whole or in part be subject to intellectual property rights. Reproduction, use, modification or disclosure to third parties of this document or
any part thereof without the express permission of u-blox is strictly prohibited.
The information contained herein is provided “as is” and u-blox assumes no liability for the use of the information. No warranty, either
express or implied, is given, including but not limited, with respect to the accuracy, correctness, reliability and fitness for a particular purpose
of the information. This document may be revised by u-blox at any time. For most recent documents, visit www.u-blox.com.
Copyright © 2016, u-blox AG.
u-blox® is a registered trademark of u-blox Holding AG in the EU and other countries. ARM® is the registered trademark of ARM Limited in
the EU and other countries.
UBX-15023940 - R02
Advance Information
Contents
Page 2 of 25
THEO-P173 - Data Sheet
Contents
Contents.............................................................................................................................. 3
1
Functional description.................................................................................................. 5
1.1
Overview .............................................................................................................................................. 5
1.2
1.3
Applications .......................................................................................................................................... 5
Product features ................................................................................................................................... 5
1.4
Block diagram....................................................................................................................................... 6
1.5
1.6
Product description ............................................................................................................................... 6
Supported features ............................................................................................................................... 6
1.6.1
1.7
2
3
MAC addresses..................................................................................................................................... 7
Host interfaces ............................................................................................................. 8
2.1
USB interface ........................................................................................................................................ 8
2.2
SPI interface.......................................................................................................................................... 8
Pin definition ................................................................................................................ 9
3.1
4
Compliance ................................................................................................................................... 7
Pin assignment ..................................................................................................................................... 9
Electrical specification ................................................................................................ 12
4.1
Absolute maximum ratings ................................................................................................................. 12
4.2
Operating conditions .......................................................................................................................... 12
4.3
4.4
Digital pad ratings .............................................................................................................................. 12
Peak power consumption ................................................................................................................... 13
4.5
Power consumption ............................................................................................................................ 13
4.6
4.7
Radio specifications ............................................................................................................................ 14
Example circuit ................................................................................................................................... 16
5
Environmental specification ...................................................................................... 17
6
Mechanical specifications .......................................................................................... 18
6.1
7
Dimensions ......................................................................................................................................... 18
Qualification and approvals ...................................................................................... 19
7.1
Approvals ........................................................................................................................................... 19
7.1.1
7.2
8
FCC compliance .......................................................................................................................... 19
FCC ID ................................................................................................................................................ 19
Product handling ........................................................................................................ 20
8.1
Packaging ........................................................................................................................................... 20
8.2
Shipment, storage and handling ......................................................................................................... 20
8.2.1
Moisture sensitivity levels ............................................................................................................. 20
8.2.2
Mounting process and soldering recommendations ..................................................................... 20
UBX-15023940 - R02
Advance Information
Contents
Page 3 of 25
THEO-P173 - Data Sheet
8.2.3
9
ESD handling precautions ............................................................................................................ 20
Labeling and ordering information........................................................................... 21
9.1
Product labeling.................................................................................................................................. 21
9.2
9.3
Explanation of codes........................................................................................................................... 21
Ordering codes ................................................................................................................................... 22
Appendix .......................................................................................................................... 23
A Glossary ...................................................................................................................... 23
Related documents........................................................................................................... 24
Revision history ................................................................................................................ 24
Contact .............................................................................................................................. 25
UBX-15023940 - R02
Advance Information
Contents
Page 4 of 25
THEO-P173 - Data Sheet
1 Functional description
1.1 Overview
The THEO-P173 module is a compact, embedded transceiver module from u-blox that facilitates development of
electronics for Vehicle-to-Everything (V2X) communication systems. This module can be used for applications
such as traffic safety, intelligent traffic management, and entertainment.
The THEO-P173 module includes an integrated MAC/LLC/Baseband processor and the required RF front-end
components. It is connected to a host processor through the USB interface. The THEO-P173 module is currently
offered as version 1.
1.2 Applications
•
•
•
•
•
Vehicle to vehicle communication
Intelligent Transport System
Vehicle Safety Services
Vehicle to Infrastructure Communication
Commercial transactions via cars
1.3 Product features
Table 1: THEO-P173 main features summary
UBX-15023940 - R02
Advance Information
Functional description
Page 5 of 25
THEO-P173 - Data Sheet
1.4 Block diagram
The block diagram of the THEO-P173 is shown in Figure 1.
5.0V
THEO-P173
SPI
FLASH
SPI
USB
ANT1
RF
FRONTEND
ANT2
TRANSCEIVER
BASEBAND
CONTROLLER
GPIOs
RF
FRONTEND
GPS1PPS_1.8V
M_RST_N
TCXO
POWER SUPPLY
3.3V
5.0V
Figure 1: THEO-P173 block diagram
1.5 Product description
Model
Description
THEO-P173
Dual-antenna diversity and single channel
1.6 Supported features
The features supported in THEO-P173 are listed below:
Feature
Description
Standards
IEEE 802.11p – 2010
ETSI ES 202 663
IEEE 1609.4 – 2010
Frequency bands
5.850 – 5.925 GHz (channels 172, 174, 176, 178, 180, 182, 184)
Transmit power
5.9 GHz: -10 to +23 dBm
5.9 GHz: Class C
Receive sensitivity
5.9 GHz: -97 dBm @ 3 Mbps
Antenna diversity - 5.9 GHz only
CDD Transmit Diversity
MRC Receive Diversity
Channel bandwidth
10, 20 MHz1
Supported data rates
3, 4.5, 6, 9, 12, 18, 24, 27 Mbps for 10 MHz bandwidth signal
Power supply
3.3 V and 5.0 V
Power consumption
4W (Maximum, Average)
Operating temperature
-40 °C to +85 °C
Dimensions
30.0 x 40.0 x 4.0 mm
1
20 MHz channel bandwidth is not supported by the firmware.
UBX-15023940 - R02
Advance Information
Functional description
Page 6 of 25
THEO-P173 - Data Sheet
1.6.1 Compliance
•
•
Compliance with WAVE and ETSI ITS G5 for US and Europe operations
Radio type approvals for the United States (FCC)
1.7 MAC addresses
The THEO-P173 module does not store any MAC address internally, as the unique MAC address is not required
for V2X application. The THEO-P173 serial number can be used as a unique MAC address if the modules are
configured to operate in IEEE 802.11a networks.
UBX-15023940 - R02
Advance Information
Functional description
Page 7 of 25
THEO-P173 - Data Sheet
2 Host interfaces
2.1 USB interface
THEO-P173 module supports a USB 2.0 high-speed interface. The THEO-P173 module uses the USB interface for
firmware loading (booting) and high speed data transfer (> 200 Mbps). The USB interface of the module is
powered with 3.3 V supply voltage. The module acts as a device on the USB bus.
See THEO-P173 System Integration Manual [2] for more information about the USB interface.
2.2 SPI interface
The THEO-P173 does not support an SPI interface for booting and data transfer.
Contact u-blox support for your area, as listed in the Contact section for more information.
UBX-15023940 - R02
Advance Information
Host interfaces
Page 8 of 25
THEO-P173 - Data Sheet
3 Pin definition
3.1 Pin assignment
The pin definition for the THEO-P173 module is provided in Figure 2. All pins marked as NC or begin with “#”
should be soldered for mechanical strength with no further electrical connections.
Figure 2: THEO-P173 pin assignment - Transparent top view
UBX-15023940 - R02
Advance Information
Pin definition
Page 9 of 25
THEO-P173 - Data Sheet
Pin
Assignment
1
# M_TMS
Pin direction
Description
Remarks
JTAG TMS
Leave unconnected
2
2
M_RST_N
I
Module Reset (1.8V)
3
3V3_DIG1
P
3.3V Power Supply
4
3V3_DIG2
P
3.3V Power Supply
5
GND
P
Ground
6
# PS_EN
This pin is internally pulled to pin 3 and 4, the 3.3V supply
lines. This should not be shorted or pulled to ground.
SeeTHEO-P173 System Integration Manual [2].
7
# PCB_LOAD0
Configuration pin
Leave unconnected
8
# PCB_LOAD1
Configuration pin
Leave unconnected
9
# PCB_LOAD2
Configuration pin
Leave unconnected
10
# I2C_1_SDA
I2C_1 SDA
Leave unconnected
11
# I2C_1_SCL
I2C_1 SCL
Leave unconnected
12
GND
P
Ground
13
5V0_PA1
P
5.0 V Power Supply (RF Ant 1)3
14
# GPIO2_11
GPIO (baseband controller)
Leave unconnected
15
# GPIO2_12
GPIO (baseband controller)
Leave unconnected
16
GND
17
# EXT_PD
18
GND
P
Ground
19
RF5G_ANT1
O
5.9 GHz RF Port (Ant 1)
20
GND
P
Ground
21
N/C
22
GND
P
Ground
23
N/C
24
GND
P
Ground
25
GND
P
Ground
26
N/C
27
GND
P
Ground
28
N/C
29
GND
P
Ground
30
RF5G_ANT2
RF
5 GHz RF Port (Ant 2)
31
GND
P
Ground
32
GND
P
Ground
33
# GPIO2_14
GPIO (baseband controller)
Leave unconnected
34
# GPIO2_13
GPIO (baseband controller)
Leave unconnected
35
GND
P
Ground
Leave unconnected
ADC input
P
Ground
2
This pin should be driven by an open drain/collector device. It is internally pulled high to 3.3 V by 10 k. During reset, it should be below
0.2 V.
3
The 5V0_PAn pins should have bypass caps located at the pin. These are NOT connected internally and each supply is isolated to its own
PA. Provide supply whenever the module main supply is powered.
UBX-15023940 - R02
Advance Information
Pin definition
Page 10 of 25
THEO-P173 - Data Sheet
Pin
Assignment
Pin direction
Description
Remarks
3
36
5V0_PA2
P
5.0 V Power Supply (RF Ant 2)
37
GND
P
Ground
38
M_SPI_MOSI
O
Module SPI Bus (1.8V)4
39
M_SPI_SCK
O
Module SPI Bus (1.8V)
40
GND
P
Ground
41
M_SPI_MISO
I
Module SPI Bus (1.8V)
4
42
M_SPI_CS
O
Module SPI Bus (1.8V)
4
43
MOD_IO_SPARE
O
General Purpose IO (1.8 V)5
44
GND
P
Ground
45
M_USB_D_N
BI
Module USB Bus6
46
M_USB_D_P
BI
Module USB Bus6
47
GND
P
Ground
48
M_USB_VBUS
P
Module USB Bus (5.0V)6
49
# UART1_RX
UART1 RX
Leave unconnected
50
# UART1_TX
UART1 TX
Leave unconnected
51
GND
P
Ground
52
GPS_1PPS_1V8
I
1PPS Input (1.8v)7
53
GND
P
Ground
54
# UART2_RX
UART2 RX
Leave unconnected
55
# BOOT2/UART2_TX
BOOT mode selection / UART2 TX
Leave unconnected
56
# BOOT0
BOOT mode selection
Leave unconnected
57
# BOOT1
BOOT mode selection
Leave unconnected
58
# M_TDO
JTAG TDO
Leave unconnected
59
# M_TDI
JTAG TDI
Leave unconnected
60
GND
61
# M_TCLK
JTAG TCLK
Leave unconnected
62
# M_TRSTN
JTAG TRSTN
Leave unconnected
P
4
Ground
Table 2: THEO-P173 pin-out
Pin direction:
P=Power
I=Input
O=Output
BI=Bidirectional
RF=Radio Frequency
4
The SPI bus is nominally an output on all modules. Internally, depending upon the version of module, there may be a flash memory on this
bus. Direction of these lines may be swapped on some versions of the module depending upon customer requirements. Always check your
modules’ model and version with the THEO-P173 System Integration Manual [2].
5
This line is optionally a SPI CS line. In other cases, it may be used as a GPIO. Please check the model number against HW documentation for
information on how to use this pin in your application.
6
The USB interface is only between the module and host processor for short impedance controlled traces. The data and VBUS signals should
be applied to these pins only when the module has power applied otherwise damage may occur.
7
This input, as with all inputs, should not be driven in to the device when the power is not supplied to the module. Otherwise damage will
occur. Contact u-blox support for your area for further information.
UBX-15023940 - R02
Advance Information
Pin definition
Page 11 of 25
THEO-P173 - Data Sheet
4 Electrical specification
Stressing the device above one or more of the ratings listed in the Absolute Maximum Rating
section may cause permanent damage. These are stress ratings only. Operating the module at
these or at any conditions other than those specified in the Operating conditions section of this
document should be avoided. Exposure to absolute maximum rating conditions for extended
periods may affect device reliability.
Operating condition ranges define those limits within which the functionality of the device is guaranteed.
Where application information is given, it is advisory only and does not form part of the specification.
4.1 Absolute maximum ratings
Symbol
Description
Min.
Max.
Units
3V3_DIG1
3V3_DIG2
Power supply voltage 3.3 V
-0.3
3.9
V
5V0_PA1
5V0_PA2
Power supply voltage 5.0 V
-0.3
6.0
V
TSTORAGE
Storage temperature
-40
+85
ºC
Table 3: Absolute maximum ratings
The product is not protected against overvoltage or reversed voltages. If necessary, voltage
spikes exceeding the power supply voltage specification, given in table above, must be limited
to values within the specified boundaries by using appropriate protection devices.
4.2 Operating conditions
Symbol
Parameter
Min.
Typ
Max.
Units
3V3_DIG1
3V3_DIG2
5V0_PA1
5V0_PA2
Power supply voltage 3.3 V
3.0
3.3
3.6
V
Power supply voltage 5.0 V
4.5
5.0
5.5
V
TA
Ambient operating temperature
-40
-
+85
ºC
Ripple Noise
Peak-to-peak voltage ripple on 3V3_DIGx and 5VO_PAx
supply lines.
-
-
TBD
mV
Min.
Max.
Units
Table 4: Operating conditions
4.3 Digital pad ratings
Symbol
Parameter
Conditions
VIH
Input high voltage
0.8*1V8
1V8+0.3
V
VIL
Input low voltage
-0.3
0.3*1V8
V
mV
VHYS
Input hysteresis
180
-
VOH
Output high voltage
IOmax = 5 mA
1V8-0.4
-
V
VOH
Output low voltage
IOmax = -5 mA
-
0.4
V
Table 5: Digital pad ratings
UBX-15023940 - R02
Advance Information
Electrical specification
Page 12 of 25
THEO-P173 - Data Sheet
4.4 Peak power consumption
Peak current8 (mA)
Operation Mode
RX
5.9 GHz
TX
5.9 GHz
3V3_DIG1 +
3V3_DIG2
5V0_PA1
5V0_PA2
700 mA
0
0
+23 dBm
700 mA
500 mA
500 mA
+15 dBm
700 mA
TBD
TBD
+10 dBm
700 mA
TBD
TBD
+0 dBm
700 mA
TBD
TBD
Table 6: Peak power consumption
4.5 Power consumption
Power consumption for different operation modes - TBD
8
Peak values are shown. The average current for full operation mode (not a power save mode) strongly depends on RX/TX time ratio and
remains within the range between the peak values of RX and TX.
UBX-15023940 - R02
Advance Information
Electrical specification
Page 13 of 25
THEO-P173 - Data Sheet
4.6 Radio specifications
The THEO-P173 modules support 802.11p in the 5.9 GHz band. The radio specifications for THEO-P173 modules
are provided in the table below.
Parameter
Operation Mode
Specification
RF Frequency Range
802.11p
5.85 – 5.925 GHz
OFDM
Modulation
802.11p
Supported Data Rates
802.11p
3, 4.5, 6, 9, 12, 18, 24, 27 Mbps
Supported Bandwidth
802.11p
10 MHz
Maximum Transmit Power
802.11p
23 dBm ± 2 dB
Minimum Transmit Power
802.11p
Receiver sensitivity
802.11p
-10 dBm
10 MHz,
no multipath,
25 °C
10 MHz,
NLoS (Non-line-of-sight),
25 °C
3 Mbps
-98 dBm typ., -95 dBm min.
4.5 Mbps
-96 dBm typ., -93 dBm min.
6 Mbps
-95 dBm typ., -92 dBm min.
9 Mbps
-93 dBm typ., -90 dBm min.
12 Mbps
-90 dBm typ., -87 dBm min.
18 Mbps
-86 dBm typ., -83 dBm min.
24 Mbps
-82 dBm typ., -79 dBm min.
27 Mbps
-80 dBm typ., -77 dBm min.
3 Mbps
-95 dBm typ., -92 dBm min.
4.5 Mbps
-92 dBm typ., -89 dBm min.
6 Mbps
-88 dBm typ., -85 dBm min.
9 Mbps
-86 dBm typ., -83 dBm min.
12 Mbps
-85 dBm typ., -82 dBm min.
18 Mbps
-82 dBm typ., -79 dBm min.
24 Mbps
na
27 Mbps
Receiver maximum operating input level
802.11p
RSSI accuracy
802.11p
Centre frequency and symbol clock tolerance
802.11p
Transmitter spectral flatness
802.11p
na
-20 dBm
Over tempearature range
+/-2 dB
+/-10 ppm
All modulation modes
< +/-2 dB
Transmitter centre frequency leakage
802.11p
< -15 dB
Transmit power control step size
802.11p
0.5 dB
Transmit power control accuracy
802.11p
Over tempearature range
+/-2 dB
Table 7: Radio specifications
Table 8 shows the Highway NLoS (Non-line-of-sight) channel parameters that are used to obtain the receiver
sensitivity values in Table 7. This channel was used in RF testing at the third ETSI Plug test (CMS3).
Each tap is faded using Pure Doppler, but the second antenna has a Doppler increased by 11 Hz, which prevents
phase synchronization of channels. The RX Power listed in Table 7 refers to the power of Tap 0.
The values presented are typical values, measured at +25 °C.
Tap#
Relative Power (dB)
Delay (ns)
Doppler Frequency (Hz)
0
0
0
0
1
-2
200
689
2
-5
433
-492
3
-7
700
886
Table 8: Highway NLoS channel parameters
UBX-15023940 - R02
Advance Information
Electrical specification
Page 14 of 25
THEO-P173 - Data Sheet
The adjacent and non-adjacent channel rejection measurements are provided in Table 9 and Table 10
respectively.
Bit rate
Target ACR (dB)
Target opt. enc. ACR (dB)
THEO-P173 typical ACR (dB)
3 Mbps (1/2BPSK)
16
28
37
4.5 Mbps (3/4BPSK)
15
27
33
6 Mbps (1/2QPSK)
13
25
35
9 Mbps (3/4QPSK)
11
23
29
12 Mbps (1/2QAM16)
8
20
29
18 Mbps (3/4QAM16)
4
16
25
24 Mbps (2/3QAM64)
0
12
22
27 Mbps (3/4QAM64)
-1
11
20
Table 9: Adjacent channel rejection
Bit rate
Target ACR (dB)
Target opt. enc. ACR (dB)
THEO-P173 typical ACR (dB)
3 Mbps (1/2BPSK)
32
42
51
4.5 Mbps (3/4BPSK)
31
41
48
6 Mbps (1/2QPSK)
29
39
48
9 Mbps (3/4QPSK)
27
37
45
12 Mbps (1/2QAM16)
24
34
42
18 Mbps (3/4QAM16)
20
30
38
24 Mbps (2/3QAM64)
16
26
34
27 Mbps (3/4QAM64)
15
25
32
Table 10: Non-adjacent channel rejection
UBX-15023940 - R02
Advance Information
Electrical specification
Page 15 of 25
THEO-P173 - Data Sheet
4.7 Example circuit
Figure 3: Example circuit around THEO-P173 module
Designator
Part description
Manufacturer
Manufacturer Part #
C1
CAP CER .1UF 16V X7R 0402
Murata
GRM155R71C104KA88D
C2, C3, C4, C5, C6, C7
CAP CER 47uF 10V X5R 1206 +/-20%
Taiyo Yuden
LMK316BJ476ML-T
R1
RES CHIP 43k OHM 1/16W 0402 +/-1%
Yageo
RC0402FR-0743KL
Q1A
TRANS NPN/NPN BC846BS,115 NXP SOT363
NXP
BC846BS
Table 11: Example circuit Bill of Materials
UBX-15023940 - R02
Advance Information
Electrical specification
Page 16 of 25
THEO-P173 - Data Sheet
5 Environmental specification
The performance of the THEO-P173 module will be valid over a temperature range of -40 °C to +85 °C (PCB
ambient temperature). Table 12 provides a summary of the environmental requirements for the THEO-P173
module.
Item
Standard
Vibration
ISO 16750
Mechanical shock
DIN EN 60068
Damp heat
IEC 60068
Drop test
ISO16750-3:2007
DIN EN 60068-2-32:1995
Table 12: THEO-P173 module environmental requirements
UBX-15023940 - R02
Advance Information
Environmental specification
Page 17 of 25
THEO-P173 - Data Sheet
6 Mechanical specifications
6.1 Dimensions
The physical dimension of the THEO-P173 module is provided in Figure 4. The module is a rectangular unit with
dimensions of 30.0 mm x 40.0 mm and a height of approximately 4.0 mm.
Figure 4: Physical dimensions of THEO-P173
Figure 5: Recommended footprint
UBX-15023940 - R02
Advance Information
Mechanical specifications
Page 18 of 25
THEO-P173 - Data Sheet
7 Qualification and approvals
7.1 Approvals
Products marked with this lead-free symbol on the product label comply with the
"Directive 2002/95/EC of the European Parliament and the Council on the Restriction of
Use of certain Hazardous Substances in Electrical and Electronic Equipment" (RoHS).
THEO-P173 transceiver modules are RoHS compliant.
7.1.1 FCC compliance
The THEO-P173 module complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired
operation.
Non authorized modification could void authority to use this equipment. The internal / external antenna(s) used
for this module must provide a separation distance of at least 20 cm from all persons and must not be
co-located or operating in conjunction with any other antenna or transmitter.
These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the manufacturer’s instructions, may cause harmful interference to radio
communications.
The outside of final product that contains the THEO-P173 module must display in a user accessible area a
label referring to the enclosed module. This exterior label can use wording such as the following:
“Contains Transmitter Module FCC ID: XPYTHEOP173” or “Contains FCC ID: XPYTHEOP173”.
7.2 FCC ID
Model name
FCC ID
THEO-P173
XPYTHEOP173
Table 13: FCC ID for THEO-P173
UBX-15023940 - R02
Advance Information
Qualification and approvals
Page 19 of 25
THEO-P173 - Data Sheet
8 Product handling
8.1 Packaging
The THEO-P173 modules are delivered on trays. For more information about packaging, see the u-blox Package
Information Guide [1].
8.2 Shipment, storage and handling
For more information regarding shipment, storage and handling see the u-blox Package Information Guide [1].
8.2.1 Moisture sensitivity levels
The THEO-P173 modules are Moisture Sensitive Devices (MSD) in accordance with the IPC/JEDEC
specification.
The Moisture Sensitivity Level (MSL) relates to the required packaging and handling precautions. The THEO-P173
modules are rated at moisture sensitivity level 4. See the u-blox Package Information Guide [1] for more
information regarding moisture sensitivity levels, labeling, and storage.
For MSL standard, see IPC/JEDEC J-STD-020, which can be downloaded from www.jedec.org.
8.2.2 Mounting process and soldering recommendations
The castellated edges of the THEO-P173 module shall be individually soldered to the host board. A visual
inspection after reflow should allow for immediate confirmation whether the solder was successful. Solder mask
and reflow profiles are explained in the THEO-P173 System Integration Manual [2].
8.2.3 ESD handling precautions
THEO-P173 modules are Electrostatic Sensitive Devices (ESD). Observe precautions for handling!
Failure to observe these precautions can result in severe damage to the Wi-Fi receiver!
Wi-Fi transceivers are Electrostatic Sensitive Devices (ESD) and require special precautions when handling.
Particular care must be exercised when handling patch antennas, due to the risk of electrostatic charges. In
addition to standard ESD safety practices, the following measures should be taken into account whenever
handling the receiver:
• Unless there is a galvanic coupling between the local GND (i.e. the work table)
and the PCB GND, then the first point of contact when handling the PCB must
always be between the local GND and PCB GND.
• Before mounting an antenna patch, connect ground of the device.
• When handling the RF pin, do not come into contact with any charged
capacitors and be careful when contacting materials that can develop charges
(e.g. patch antenna ~10 pF, coax cable ~50-80 pF/m, soldering iron, …)
• To prevent electrostatic discharge through the RF input, do not touch any
exposed antenna area. If there is any risk that such exposed antenna area is
touched in non ESD protected work area, implement proper ESD protection
measures in the design.
• When soldering RF connectors and patch antennas to the receiver’s RF pin,
make sure to use an ESD safe soldering iron (tip).
UBX-15023940 - R02
Advance Information
Product handling
Page 20 of 25
THEO-P173 - Data Sheet
9 Labeling and ordering information
9.1 Product labeling
The labels of THEO-P173 include important product information as described in this section. The data matrix
code includes a serial number.
Figure 6 illustrates the sample label of THEO-P173 and includes: pin1 marking, u-blox logo, product name
(model), type number, serial number, FCC certification number and date of unit production encoded YYWW
(year/week).
Figure 6: THEO-P173 – Sample label
9.2 Explanation of codes
Two different product code formats are used. The Product Name is used in documentation such as this data
sheet and identifies all u-blox products, independent of packaging and quality grade. The Ordering Code
includes options and quality, while the Type Number includes the hardware and firmware versions. Table 14
below details these three different formats:
Format
Structure
Product Name
PPPP-TGVV
Ordering Code
PPPP-TGVV-TTQ
Type Number
PPPP-TGVV-TTQ-XX
Table 14: Product code formats
Table 15 explains the parts of the product code.
Code
Meaning
Example
PPPP
Form factor
THEO
TG
Platform
T – Dominant technology, For example, W: Wi-Fi, B: Bluetooth
G - Generation
P1
VV
Variant based on the same platform; range [00…99]
73
TT
Major Product Version
00
Q
Quality grade
A: Automotive
B: Professional
C: Standard
A
XX
Minor product version (not relevant for certification)
00
Table 15: Part identification code
UBX-15023940 - R02
Advance Information
Labeling and ordering information
Page 21 of 25
THEO-P173 - Data Sheet
9.3 Ordering codes
Ordering Code
Product name
Product
THEO-P173-01A
THEO-P173
THEO-P173 module
Table 16: Product ordering code
Product changes affecting form, fit or function are documented by u-blox. For a list of Product Change
Notifications (PCNs) see our website.
UBX-15023940 - R02
Advance Information
Labeling and ordering information
Page 22 of 25
THEO-P173 - Data Sheet
Appendix
A Glossary
Name
Definition
CS
Chip select
DSRC
Dedicated Short-Range Communications
ESD
Electrostatic Sensitive Devices
ETSI
European Telecommunications Standards Institute
EVM
Earned Value Management
FCC
Federal Communications Commission
GPIO
General-purpose input/output
HD
High Definition
IC
Industry Canada
IEEE
Institute of Electrical and Electronics Engineers
ITS
Intelligent Transport Systems
LLC
Logical Link Control
MAC
Media Access Control
nACR
Non-adjacent channel rejection
NLoS
Non Line of Sight
OBU
On Board Unit
OFDM
Orthogonal frequency-division multiplexing
PCB
Printed Circuit Board
PER
Packet error rate
PPS
Pulse per second
PSDU
PLCP service data unit
RF
Radio Frequency
RoHS
Restriction of Hazardous Substances
SAR
Specific absorption rate
SPI
Serial Peripheral Interface
USB
Universal Serial Bus
UTC
Coordinated Universal Time
V2X
Vehicle-to-Everything
Table 17: Explanation of abbreviations and terms used
UBX-15023940 - R02
Advance Information
Appendix
Page 23 of 25
THEO-P173 - Data Sheet
Related documents
[1]
u-blox Package Information Guide, document number UBX-14001652
[2]
THEO-P173 System Integration Manual, document number UBX-15029954
For regular updates to u-blox documentation and to receive product change notifications please register
on our homepage.
Revision history
Revision
Date
Name
Status / Comments
R01
8-Feb-2016
vdyk, kgom
Converted version 1.5 of the CohdaMobility MK5 Module Data Sheet to u-blox
THEO-P1 Data Sheet. Product name changed from Cohda MK5 to THEO-P1. Initial
release.
R02
30-Nov-2016
este, kgom
Updated Figure 3. Changed the product name as “THEO-P173” and the product
grade as Professional. Modified Table 1.
UBX-15023940 - R02
Advance Information
Related documents
Page 24 of 25
THEO-P173 - Data Sheet
Contact
For complete contact information visit us at www.u-blox.com.
u-blox Offices
North, Central and South America
u-blox America, Inc.
Phone:
E-mail:
+1 703 483 3180
info_us@u-blox.com
Regional Office West Coast:
Phone:
+1 408 573 3640
E-mail:
info_us@u-blox.com
Headquarters
Europe, Middle East, Africa
Asia, Australia, Pacific
u-blox AG
Phone:
E-mail:
Support:
Phone:
E-mail:
Support:
+41 44 722 74 44
info@u-blox.com
support@u-blox.com
Technical Support:
Phone:
E-mail:
+1 703 483 3185
support_us@u-blox.com
u-blox Singapore Pte. Ltd.
+65 6734 3811
info_ap@u-blox.com
support_ap@u-blox.com
Regional Office Australia:
Phone:
+61 2 8448 2016
E-mail:
info_anz@u-blox.com
Support: support_ap@u-blox.com
Regional Office China (Beijing):
Phone:
+86 10 68 133 545
E-mail:
info_cn@u-blox.com
Support: support_cn@u-blox.com
Regional Office China (Chongqing):
Phone:
+86 23 6815 1588
E-mail:
info_cn@u-blox.com
Support: support_cn@u-blox.com
Regional Office China (Shanghai):
Phone:
+86 21 6090 4832
E-mail:
info_cn@u-blox.com
Support: support_cn@u-blox.com
Regional Office China (Shenzhen):
Phone:
+86 755 8627 1083
E-mail:
info_cn@u-blox.com
Support: support_cn@u-blox.com
Regional Office India:
Phone:
+91 80 4050 9200
E-mail:
info_in@u-blox.com
Support: support_in@u-blox.com
Regional Office Japan (Osaka):
Phone:
+81 6 6941 3660
E-mail:
info_jp@u-blox.com
Support: support_jp@u-blox.com
Regional Office Japan (Tokyo):
Phone:
+81 3 5775 3850
E-mail:
info_jp@u-blox.com
Support: support_jp@u-blox.com
Regional Office Korea:
Phone:
+82 2 542 0861
E-mail:
info_kr@u-blox.com
Support: support_kr@u-blox.com
Regional Office Taiwan:
Phone:
+886 2 2657 1090
E-mail:
info_tw@u-blox.com
Support: support_tw@u-blox.com
UBX-15023940 - R02
Advance Information
Contact
Page 25 of 25