0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ISOBLOCK I-ST-1C (20A 10V)

ISOBLOCK I-ST-1C (20A 10V)

  • 厂商:

    VERIVOLT

  • 封装:

  • 描述:

    电流变送器 0 ~ 20A 输入 ±10V 输出 9 ~ 28VDC DIN 轨道

  • 数据手册
  • 价格&库存
ISOBLOCK I-ST-1C (20A 10V) 数据手册
IsoBlock I-ST Single-Channel High Performance Shunt Current Measuring Module OVERVIEW The IsoBlock I-ST is a sensor designed for high-quality isolated current measurements up to 80 Amperes. The IsoBlock I-ST module provides 1500V primary-to-secondary sustained isolation, which allows users to monitor a miscellaneous of currents at different potentials. The IsoBlock I-ST uses shunt methodology to measure the current flowing through the input conductor. In essence, this technique works by placing a high performance low impedance resistor along the current path (primary), while a galvanic isolation separates primary and secondary sides. The input current is then obtained by amplifying the voltage induced across the shunt resistor. This is followed by an anti-aliasing filter and a conditioning stage to output a ±10V signal. The compact form factor of the IsoBlock I-ST module allows users to setup high channel density monitoring systems, making it ideal for deployed and portable systems. SPECIFICATION IsoBlock I-ST External Shunt 5A 10A 30A Bandwidth (-3dB point) DC - 1MHz Integrated sensor noise (Referenced to output) ±2000V Output Offset Voltage ±5000V < ±0.01% / °C Mechanical Outer Dimensions 80A Performance Accuracy (percentage of reading) Mounting Type 50A N/A Eletrical Thermal drift gain 40A Output impedance Common mode impedance Differential Input impedance < ±500µV indication of input, output and power of the IsoBlock I-ST The IsoBlock module is designed to mount on standard NS-35 or NS-32 DIN rails with minimal preparation, providing users ease of use and flexibility. 100Ω > 2 GΩ || 4pF > 1 MΩ Environmental DIN Rail 3.5” x 2.5” x 1.5” Operating temperature – 25 to 65 °C Storage temperature – 40 to 70 °C 205 g (7.2 oz) Installation on DIN rail IsoBlock I-ST block diagram. 650 Washington St, San Francisco, CA 94111 (708) 374-8658 1 MERCHANICAL DIMENSIONS HARDWARE CONFIGURATION A. Connect external power source to power the unit. For proper functioning the power supply should provide a voltage as specified with at least 0.2A of continuous current and 0.4A surge during module start-up. A Standards and Certifications ● CE B. Securely connect one end of a twisted pair to the output terminals, and the other end to the inputs of your data acquisition unit C. Pass conductor through aperture and observe orientation for proper signal polarity. C B Warning THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage. 2
ISOBLOCK I-ST-1C (20A 10V) 价格&库存

很抱歉,暂时无法提供与“ISOBLOCK I-ST-1C (20A 10V)”相匹配的价格&库存,您可以联系我们找货

免费人工找货