ISOBLOCK V-1C (500V 5V) 数据手册
IsoBlock V
Galvanicaly Isolated Differential Voltage Sensor
OVERVIEW
The IsoBlock V-1c has been designed to provide high-quality isolated differential voltage measurements for aplications requiring scaling of high voltages, as well as superior isolation.
Each IsoBlock V unit hosts an isolated channel that can be connected to separate measurement
sources while providing a range of functional coverage up to 1500V. The input has its own isolated
reference, and can be configured to suit user needs. The output signal from the IsoBlock unit is
referenced in respect to the ground channel of the user’s data acquisition system.
Verivolt designs its IsoBlock V modules with consideration for user great flexibility, and low power
consumption.
SPECIFICATION
IsoBlock V
50V
100V
200V
300V
Bandwidth (-3dB point)
500V
750V
1000V
1500V
50
75
100
150
500 V
750 V
1000 V
1500 V
1MHz
Gain
(Using 10V standard output voltage)
Differential input dynamic range
5
10
20
30
50V
100V
200 V
300 V
Channels per module
1
Eletrical
Performance
Accuracy (percentage of
reading)
Max total phase shift at 60Hz
Max Input delay (120kHz
versions)
Isolation voltage from primary
side to secondary side
±0.2%
(±0.1% Custom)
< 0.05°
< 2.8 μs
> ±1500 V
Input-Output non-linearity
Output voltage
Gain temperature drift
Common mode rejection
at 60Hz
Power Supply Voltage
Output type
Withstanding common mode
surge voltage
±5000 V
Output Offset Voltage
(Referenced to output)
Withstanding differential mode
surge voltage
±2500 V
Differential Input
impedance
Insulation impedance
Mechanical
Output impedance
Mounting Type
DIN Rail
Connectivity (Connector for
power in and signal out to/
from the sensor)
Outer Dimensions
Channels
Weight
Spring Cage connector
1.4” x 3.5” x 2.5”
HARDWARE
DESCRIPTION
The IsoBlock V module is designed to isolate and scale down
high voltages found in industrial enviroments. The end result is
a signal ready to connect to any data acquisition system, while
galvanically isolating the source from it.
Each channel of the IsoBlock module has a galvanic isolation
from the input to the output that can eliminate large common
mode voltages. In addition to that, each channel also has a protection stage at the input that guards it from surges.
Following the input surge protection stage, there is an amplification stage that brings the input signal to a ±10V range. This signal
is modulated into a magnetic field, and then transferred across a
galvanic barrier. A demodulating stage recovers the original signal, followed by an anti-aliasing filter and a conditioning stage to
output a ±10V differential pair. The figure below shows a block
diagram of the process decribed above.
< 130 ppm
±10 V
±50 ppm/°C
112 dB
8V to 28 V
Differential pair
2σ < ±500 µV (typical)
4σ
< ±1 mV (limit)
> 10 MΩ
> 10 GΩ || 2pF
100Ω
IsoBlock V single channel block diagram.
Environmental
Operating temperature
– 25 to 70 °C
Storage temperature
– 40 to 80 °C
4 and 8 channel options
198 g (7.0 oz)
- The isolation barrier of every device is tested with a 5 second partial discharge of 1800V for 5 seconds, with a detection threshold
of 150pC.
- Withstanding common mode surge voltage is 2 seconds half sinewave.
- Withstanding differential mode surge voltage is 4 seconds half sinewave.
650 Washington St, San Francisco, CA 94111
(708) 374-8658
1
MERCHANICAL
DIMENSIONS
HARDWARE
CONFIGURATION
A. Connect external power source
to power the unit. For proper functioning the power supply should provide a
voltage between 8V and 28V with at
least 0.25A of continuous current and
0.5A surge during module start-up.
A
Standards and Certifications
● CE
B. Securely connect wire in the 20-6
AWG range between the source of
measurement and an available IsoBlock’s input screw terminal.
C. Securely connect one end of a
twisted pair to the output terminals,
and the other end to the inputs of your
data acquisition unit
C
B
DANGER
THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the
failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage.
2