ISOBLOCK V-4C (1000V 10V)

ISOBLOCK V-4C (1000V 10V)

  • 厂商:

    VERIVOLT

  • 封装:

  • 描述:

    电压变送器 ±1000V 输入 ±10V 输出 9 ~ 28VDC DIN 轨道

  • 详情介绍
  • 数据手册
  • 价格&库存
ISOBLOCK V-4C (1000V 10V) 数据手册
IsoBlock V Galvanicaly Isolated Differential Voltage Sensor OVERVIEW The IsoBlock V module has been designed to provide high-quality isolated differential voltage measurements for aplications requiring scaling of high voltages, as well as superior isolation. Each IsoBlock V unit hosts four separate isolated channels, each of which can be connected to separate measurement sources while providing a range of functional coverage up to 1500V. The input of each specific IsoBlock channel has its own isolated reference, and can be configured to suit user needs. All processed signals output from the IsoBlock unit are referenced in respect to the ground channel of the user’s data acquisition system. Verivolt designs its IsoBlock V modules with consideration for user great flexibility, high channeldensity and low power consumption. SPECIFICATION IsoBlock V 50V 100V 200V Bandwidth (-3dB point) 300V 120kHz Integrated sensor noise (Referenced to input) (1MHz custom) < 2 mV < 3 mV < 6 mV < 10 mV < 14mV 5 10 20 30 50 75 100 150 100V 200V 400 V 600 V 1000 V 1500 V 2000 V 3000 V 4 Performance Accuracy (percentage of reading) Max total phase shift at 60Hz Max Input delay (120kHz versions) ±0.2% (±0.1% custom) < 0.05° < 2.8 μs Input-Output non-linearity < ±0.1% Integrated channel noise (Referenced to output) < 1.2 mV Output voltage Gain temperature drift Isolation voltage from primary side to secondary side > ±1500 V Withstanding common mode surge voltage ±5000 V Withstanding differential mode surge voltage ±2500 V Mounting Type DIN Rail Connectivity (Connector for power in and signal out to/from the sensor) Common mode rejection at 60Hz Power Supply Voltage Output type Mechanical Weight 1500V < 1 mV Eletrical Channels 1000V < 1 mV Channels per module Outer Dimensions 750V < 1 mV Gain (Using 10V standard output voltage) Differential input dynamic range 500V Spring Cage connector 3.9” x 3.5” x 2.5” 1 and 4 channels 198 g (7.0 oz) Output Offset Voltage (Referenced to output) Differential Input impedance Insulation impedance Output impedance HARDWARE DESCRIPTION The IsoBlock V module is designed to isolate and scale down high voltages found in industrial enviroments. The end result is a signal ready to connect to any data acquisition system, while galvanically isolating the source from it. Each channel of the IsoBlock module has a galvanic isolation from the input to the output that can eliminate large common mode voltages. In addition to that, each channel also has a protection stage at the input that guards it from surges. Following the input surge protection stage, there is an amplification stage that brings the input signal to a ±10V range. This signal is modulated into a magnetic field, and then transferred across a galvanic barrier. A demodulating stage recovers the original signal, followed by an anti-aliasing filter and a conditioning stage to output a ±10V differential pair. The figure below shows a block diagram of the process decribed above. ±10 V ±50 ppm/°C 112 dB 8V to 28 V Differential pair < ±500 µV > 10 MΩ IsoBlock V single channel block diagram. > 10 GΩ || 2pF 100Ω Environmental Operating temperature – 25 to 70 °C Storage temperature – 40 to 80 °C - The isolation barrier of every device is tested with a 5 second partial discharge of 1800V for 5 seconds, with a detection threshold of 150pC. - Withstanding common mode surge voltage is 2 seconds half sinewave. - Withstanding differential mode surge voltage is 4 seconds half sinewave. 650 Washington St, San Francisco, CA 94111 (708) 374-8658 1 MERCHANICAL DIMENSIONS HARDWARE CONFIGURATION A. Connect external power source to power the unit. For proper functioning the power supply should provide a voltage between 8V and 28V with at least 0.25A of continuous current and 0.5A surge during module start-up. A Standards and Certifications ● CE B. Securely connect wire in the 20-6 AWG range between the source of measurement and an available IsoBlock’s input screw terminal. C. Securely connect one end of a twisted pair to the output terminals, and the other end to the inputs of your data acquisition unit C B DANGER THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage. 2
ISOBLOCK V-4C (1000V 10V)
物料型号:IsoBlock V

器件简介:IsoBlock V模块设计用于提供高质量的隔离差分电压测量,适用于需要缩放高电压的应用场景,同时提供优越的隔离性能。每个IsoBlock V单元包含四个独立的隔离通道,每个通道可以连接到不同的测量源,并提供高达1500V的功能覆盖范围。

引脚分配:文档中未明确提供引脚分配信息,但提到了模块的输入和输出端子,包括电源输入、信号输入和信号输出。

参数特性: - 带宽:最高120kHz(可定制至1MHz) - 集成传感器噪声:小于1mV至小于14mV,取决于量程 - 增益:5至150,使用10V标准输出电压 - 差分输入动态范围:100V至3000V - 通道数:每个模块1或4个通道

功能详解: - 每个IsoBlock通道的输入有自己的隔离参考,并可以配置以满足用户需求。 - 所有处理后的信号输出都是相对于用户数据采集系统的地线通道。 - 模块设计考虑了用户的灵活性、高通道密度和低功耗。

应用信息:IsoBlock V模块设计用于隔离和缩放工业环境中的高电压,最终结果是准备好连接到任何数据采集系统的信号,同时从源头进行电气隔离。

封装信息: - 安装类型:DIN轨道 - 连接器:弹簧笼式连接器 - 外形尺寸:3.9x3.5x2.5英寸 - 重量:198克(7.0盎司)
ISOBLOCK V-4C (1000V 10V) 价格&库存

很抱歉,暂时无法提供与“ISOBLOCK V-4C (1000V 10V)”相匹配的价格&库存,您可以联系我们找货

免费人工找货
ISOBLOCK V-4C (1000V 10V)
  •  国内价格 香港价格
  • 1+12036.171421+1445.63704

库存:11