0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ISOBLOCK V-4C (1500V 10V)

ISOBLOCK V-4C (1500V 10V)

  • 厂商:

    VERIVOLT

  • 封装:

  • 描述:

    电压变送器 ±1500V 输入 ±10V 输出 9 ~ 28VDC DIN 轨道

  • 数据手册
  • 价格&库存
ISOBLOCK V-4C (1500V 10V) 数据手册
IsoBlock V Galvanicaly Isolated Differential Voltage Sensor OVERVIEW The IsoBlock V module has been designed to provide high-quality isolated differential voltage measurements for aplications requiring scaling of high voltages, as well as superior isolation. Each IsoBlock V unit hosts four separate isolated channels, each of which can be connected to separate measurement sources while providing a range of functional coverage up to 1500V. The input of each specific IsoBlock channel has its own isolated reference, and can be configured to suit user needs. All processed signals output from the IsoBlock unit are referenced in respect to the ground channel of the user’s data acquisition system. Verivolt designs its IsoBlock V modules with consideration for user great flexibility, high channeldensity and low power consumption. SPECIFICATION IsoBlock V 50V 100V 200V Bandwidth (-3dB point) 300V 120kHz Integrated sensor noise (Referenced to input) (1MHz custom) < 2 mV < 3 mV < 6 mV < 10 mV < 14mV 5 10 20 30 50 75 100 150 100V 200V 400 V 600 V 1000 V 1500 V 2000 V 3000 V 4 Performance Accuracy (percentage of reading) Max total phase shift at 60Hz Max Input delay (120kHz versions) ±0.2% (±0.1% custom) < 0.05° < 2.8 μs Input-Output non-linearity < ±0.1% Integrated channel noise (Referenced to output) < 1.2 mV Output voltage Gain temperature drift Isolation voltage from primary side to secondary side > ±1500 V Withstanding common mode surge voltage ±5000 V Withstanding differential mode surge voltage ±2500 V Mounting Type DIN Rail Connectivity (Connector for power in and signal out to/from the sensor) Common mode rejection at 60Hz Power Supply Voltage Output type Mechanical Weight 1500V < 1 mV Eletrical Channels 1000V < 1 mV Channels per module Outer Dimensions 750V < 1 mV Gain (Using 10V standard output voltage) Differential input dynamic range 500V Spring Cage connector 3.9” x 3.5” x 2.5” 1 and 4 channels 198 g (7.0 oz) Output Offset Voltage (Referenced to output) Differential Input impedance Insulation impedance Output impedance HARDWARE DESCRIPTION The IsoBlock V module is designed to isolate and scale down high voltages found in industrial enviroments. The end result is a signal ready to connect to any data acquisition system, while galvanically isolating the source from it. Each channel of the IsoBlock module has a galvanic isolation from the input to the output that can eliminate large common mode voltages. In addition to that, each channel also has a protection stage at the input that guards it from surges. Following the input surge protection stage, there is an amplification stage that brings the input signal to a ±10V range. This signal is modulated into a magnetic field, and then transferred across a galvanic barrier. A demodulating stage recovers the original signal, followed by an anti-aliasing filter and a conditioning stage to output a ±10V differential pair. The figure below shows a block diagram of the process decribed above. ±10 V ±50 ppm/°C 112 dB 8V to 28 V Differential pair < ±500 µV > 10 MΩ IsoBlock V single channel block diagram. > 10 GΩ || 2pF 100Ω Environmental Operating temperature – 25 to 70 °C Storage temperature – 40 to 80 °C - The isolation barrier of every device is tested with a 5 second partial discharge of 1800V for 5 seconds, with a detection threshold of 150pC. - Withstanding common mode surge voltage is 2 seconds half sinewave. - Withstanding differential mode surge voltage is 4 seconds half sinewave. 650 Washington St, San Francisco, CA 94111 (708) 374-8658 1 MERCHANICAL DIMENSIONS HARDWARE CONFIGURATION A. Connect external power source to power the unit. For proper functioning the power supply should provide a voltage between 8V and 28V with at least 0.25A of continuous current and 0.5A surge during module start-up. A Standards and Certifications ● CE B. Securely connect wire in the 20-6 AWG range between the source of measurement and an available IsoBlock’s input screw terminal. C. Securely connect one end of a twisted pair to the output terminals, and the other end to the inputs of your data acquisition unit C B DANGER THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage. 2
ISOBLOCK V-4C (1500V 10V) 价格&库存

很抱歉,暂时无法提供与“ISOBLOCK V-4C (1500V 10V)”相匹配的价格&库存,您可以联系我们找货

免费人工找货