Additional Resources:
Product Page
|
3D Model
date
11/14/2023
page 1 of 9
SERIES: CBM-40C | DESCRIPTION: DC BLOWER
FEATURES
• omniCOOL™ bearing system
• 40 x 40 mm frame
• multiple speed options
• PWM/tachometer wires available
MODEL
input
voltage
input
current1
input
power1
rated
speed1
airflow2
static
pressure3
(inch H2O)
noise4
rated
(Vdc)
range
(Vdc)
typ
(A)
max
(A)
typ
(W)
max
(W)
typ
(RPM±15%)
(CFM)
typ
(dBA)
CBM-4007C-035-218
5
4.5~5.5
0.04
0.06
0.20
0.30
3,5006
0.99
0.18
21.8
CBM-4007C-050-238
5
4.5~5.5
0.09
0.14
0.45
0.70
5,000
1.42
0.36
23.8
CBM-4007C-065-295
5
4.5~5.5
0.14
0.21
0.70
1.05
6,500
1.85
0.71
29.5
CBM-4007C-135-218
12
10.8~13.2
0.04
0.06
0.48
0.72
3,5006
0.99
0.18
21.8
CBM-4007C-150-238
12
10.8~13.2
0.06
0.09
0.72
1.08
5,000
1.42
0.36
23.8
CBM-4007C-165-295
12
10.8~13.2
0.09
0.14
1.08
1.68
6,500
1.85
0.71
29.5
CBM-4010C-140-178
12
10.8~13.2
0.05
0.08
0.06
0.96
4,0005
1.17
0.07
17.8
CBM-4010C-150-227
12
10.8~13.2
0.06
0.09
0.72
1.08
5,0005
1.46
0.11
22.8
CBM-4020C-130-216
12
10.8~13.2
0.02
0.04
0.24
0.48
3,0007
1.33
0.05
21.6
CBM-4020C-145-305
12
10.8~13.2
0.04
0.06
0.48
0.72
4,5007
1.99
0.11
30.5
CBM-4020C-160-367
12
10.8~13.2
0.08
0.12
0.96
1.44
6,0008
2.66
0.19
36.7
Notes:
1. At rated voltage, after 3 minutes.
2. At rated voltage, room temperature, 65% humidity, 0 inch H20 static pressure.
3. At rated voltage, 0 CFM airflow.
4. Measured in an anechoic chamber as per ISO3745/GB4214-84 at rated voltage, with background noise 20±2 dBA at 1 m from the fan intake.
5. Typical rated speed is measured as RPM±900 at rated voltage.
6. Typical rated speed is measured as RPM±700 at rated voltage.
7. Typical rated speed is measured as RPM±600 at rated voltage.
8. Typical rated speed is measured as RPM±10% at rated voltage.
9. All specifications are measured at 25°C, 65% relative humidity unless otherwise specified.
PART NUMBER KEY
CBM - 4010C - 140 - 178 - XX - CXX
Base Number
Fan Signals
“blank” = no signals
20 = tachometer signal
22 = tachometer signal / PWM control signal
cuidevices.com
Reserved for Custom
Configurations
Additional Resources:
Product Page
|
3D Model
CUI DEVICES | SERIES: CBM-40C | DESCRIPTION: DC BLOWER
date 11/14/2023 | page 2 of 9
INPUT
parameter
conditions/description
min
typ
max
units
operating input voltage
5 Vdc input models
12 Vdc input models
4.5
10.8
5
12
5.5
13.2
Vdc
Vdc
starting voltage
5 Vdc input models
12 Vdc input models, CBM-4007C and CBM-4020C models
12 Vdc input models, CBM-4010C models
3.5
7
8
Vdc
Vdc
Vdc
PERFORMANCE10
parameter
conditions/description
max
units
rated speed
at rated voltage, 25°C, after 3 minutes
3,500
6,500
RPM
air flow
at 0 inch H2O, see performance curves
0.99
2.66
CFM
static pressure
at 0 CFM, see performance curves
0.07
0.71
inch H2O
noise
at 1 m, rated speed
17.8
36.7
dBA
max
units
max
units
Note:
min
typ
10. See Model section on page 1 for specific values.
PROTECTIONS / FEATURES11
parameter
conditions/description
auto restart
not available on models CBM-4010C-140-178,
CBM-4010C-150-227, & CBM-4010C-160-267
polarity protection
only available on models CBM-4010C-140-178, CBM-4010C-150-227, & CBM4010C-160-267,
CBM-4020C-130-216, CBM-4020C-145-305, CBM-4020C-160-367
tachometer signal
available on “20” and “22” models
PWM control signal
available on “22” models
Notes:
min
typ
11. See Application Notes for details.
SAFETY & COMPLIANCE
parameter
conditions/description
insulation resistance
at 500 Vdc between frame and positive terminal
min
dielectric strength
at 500 Vac, 60 Hz, 1 minute between housing and positive
terminal
safety approvals
UL/cUL 507, TUV (EN/IEC 62368-1:2020+A11)
EMI/EMC
EN 55032:2015, EN 55035:2017
life expectancy
at 40°C, 65% RH, 90% confidence level
RoHS
yes
typ
10
MΩ
5
40,000
mA
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
-10
storage temperature
typ
max
units
70
°C
-40
75
°C
operating humidity
non-condensing
35
85
%
storage humidity
non-condensing
35
85
%
cuidevices.com
Additional Resources:
Product Page
|
3D Model
CUI DEVICES | SERIES: CBM-40C | DESCRIPTION: DC BLOWER
date 11/14/2023 | page 3 of 9
PERFORMANCE CURVES
CBM-4007C-050-238
Static Pressure (mm H O)
2
Static Pressure (mm H O)
2
CBM-4007C-035-218
Air Flow (CFM)
CBM-4007C-135-218
Static Pressure (mm H O)
2
Static Pressure (mm H O)
2
CBM-4007C-065-295
Air Flow (CFM)
Air Flow (CFM)
CBM-4007C-165-295
Static Pressure (mm H O)
2
Static Pressure (mm H O)
2
CBM-4007C-150-238
Air Flow (CFM)
Air Flow (CFM)
Air Flow (CFM)
cuidevices.com
Additional Resources:
Product Page
|
3D Model
CUI DEVICES | SERIES: CBM-40C | DESCRIPTION: DC BLOWER
date 11/14/2023 | page 4 of 9
PERFORMANCE CURVES (CONTINUED)
CBM-4010C-150-227
Static Pressure (mm H O)
2
Static Pressure (mm H O)
2
CBM-4010C-140-178
Air Flow (CFM)
Air Flow (CFM)
Air Flow (CFM)
Static Pressure (mm H O)
2
CBM-4020C-130-216
Static Pressure (mm H O)
2
CBM-4010C-160-267
Air Flow (CFM)
CBM-4020C-160-367
Static Pressure (mm H O)
2
Static Pressure (mm H O)
2
CBM-4020C-145-305
Air Flow (CFM)
Air Flow (CFM)
cuidevices.com
Additional Resources:
Product Page
|
3D Model
CUI DEVICES | SERIES: CBM-40C | DESCRIPTION: DC BLOWER
date 11/14/2023 | page 5 of 9
MECHANICAL
parameter
conditions/description
motor
4 pole DC brushless
min
bearing system
omniCOOL™
direction of rotation
counter-clockwise viewed from front of fan blade
dimensions
CBM-4007C models: 40 x 40 x 7
CBM-4010C models: 39.5 x 39.5 x 10
CBM-4020C models: 40.5 x 40.5 x 20
material
PBT (UL94V-0)
weight
CBM-4007C models, weight values by model
CBM-4010C models
CBM-4020C models
typ
max
units
mm
mm
mm
9.92
11.8
24
11.1
g
g
g
MECHANICAL DRAWING
units: mm
MOUNTING SCREW (Pan Head)
2 wire versions (+Vin & -Vin): UL 1061, 28 AWG
3 wire versions (+Vin, -Vin, & tach): UL 1061, 28 AWG
4 wire versions (+Vin, -Vin, tach, & PWM): UL 1061, 28 AWG
CBM-4007C
WIRE CONNECTIONS
Wire Color
Function
Red
+Vin
Black
-Vin
Yellow12
Tach Signal
Blue12
PWM
Notes: 12. Wires only present on versions with output signals.
cuidevices.com
Screw Type
Size
Standard
Torque
Machine Screw
M2
JIS B1111-1974
1~2 kgf-cm
Additional Resources:
Product Page
|
3D Model
CUI DEVICES | SERIES: CBM-40C | DESCRIPTION: DC BLOWER
date 11/14/2023 | page 6 of 9
MECHANICAL DRAWING (CONTINUED)
units: mm
MOUNTING SCREW (Pan Head)
2 wire versions (+Vin & -Vin): UL 1061, 26 AWG
3 wire versions (+Vin, -Vin, & tach): UL 1061, 26 AWG
4 wire versions (+Vin, -Vin, tach, & PWM): UL 1061, 26 AWG
CBM-4010C
WIRE CONNECTIONS
Wire Color
Function
Red
+Vin
Black
-Vin
Yellow
Tach Signal
Blue12
PWM
12
Notes: 12. Wires only present on versions with output signals.
cuidevices.com
Screw Type
Size
Standard
Torque
Machine Screw
M2
JIS B1111-1974
1~2 kgf-cm
Additional Resources:
Product Page
|
3D Model
CUI DEVICES | SERIES: CBM-40C | DESCRIPTION: DC BLOWER
date 11/14/2023 | page 7 of 9
MECHANICAL DRAWING (CONTINUED)
units: mm
MOUNTING SCREW (Pan Head)
2 wire versions (+Vin & -Vin): UL 1061, 26 AWG
3 wire versions (+Vin, -Vin, & tach): UL 1061, 26 AWG
4 wire versions (+Vin, -Vin, tach, & PWM): UL 1061, 28 AWG
Screw Type
Size
Standard
Torque
Machine Screw
M3
JIS B1111-1974
7.5 kgf-cm
Self-tapping Screw
M4
JIS B1122 Type 2
7.5 kgf-cm
CBM-4020C
WIRE CONNECTIONS
Wire Color
Function
Red
+Vin
Black
-Vin
Yellow
Tach Signal
Blue12
PWM
12
LABEL
Notes: 12. Wires only present on versions with output signals.
cuidevices.com
Additional Resources:
Product Page
|
3D Model
CUI DEVICES | SERIES: CBM-40C | DESCRIPTION: DC BLOWER
date 11/14/2023 | page 8 of 9
APPLICATION NOTES
Auto Restart Protection
When the fan motor is locked by an external force, the device will temporarily turn off electrical power to the motor and restart
automatically when the locked rotor condition is released.
Polarity Protection
Able to withstand 10 minutes of reverse polarity connection between the positive and negative wires without causing damage.
Tachometer Signal (Yellow Wire)
The tachometer signal is for detecting the rotational speed of the fan motor. The output will be a square wave when fan is operating and
VFG or VCE depending on the locked rotor position when fan motor is locked (See Figures 1~2 below).
Figure 1: Tachometer
Output Circuit
Output Type: Open Collector
Vs: (VFG)
5 V fan: 3.3~5 V
All others: 3.3~15 V
Ic≤5 mA
R≥Vs/Ic
VCE(sat)≤0.5 V
Figure 2: Tachometer
Output Waveform
4 Pole Motor
N=RPM
T=60/N (sec)
FG=1/T*2 (Hz)
N=FG*30
PWM Signal (Blue Wire)
This wire is for speed control of the fan motor using a PWM input signal from the customer circuit (See Figure 3 below).
Figure 3: PWM Input Signal
PWM Duty Cycle (%) = T1/T x 100%
PWM Frequency Range: 20~30 kHz
PWM VIH = 2.8~5.5 V
PWM VIL = 0~0.6 V
cuidevices.com
Additional Resources:
Product Page
|
3D Model
CUI DEVICES | SERIES: CBM-40C | DESCRIPTION: DC BLOWER
date 11/14/2023 | page 9 of 9
REVISION HISTORY
rev.
description
date
1.0
initial release
05/13/2021
1.01
added PWM signal versions
05/19/2022
1.02
logo, datasheet style update
08/12/2022
1.03
added new models
05/05/2023
1.04
added new models
11/14/2023
The revision history provided is for informational purposes only and is believed to be accurate.
CUI Devices offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI Devices reserves the right to make changes to the product at any time without notice. Information provided by CUI Devices is believed to be accurate
and reliable. However, no responsibility is assumed by CUI Devices for its use, nor for any infringements of patents or other rights of third parties which may
result from its use.
CUI Devices products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A
critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life
support device or system, or to affect its safety or effectiveness.
cuidevices.com