0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3197

3197

  • 厂商:

    ASM-SENSOR

  • 封装:

  • 描述:

    3197 - POWER QUALITY ANALYZER - ASM GmbH

  • 数据手册
  • 价格&库存
3197 数据手册
POWER QUALITY ANALYZER 3197 Power Measuring Instruments T h e M o s t C o m p r e h e n s i ve Portable PQA on The Market Catch Power Quality Problems on the Fly... Monitor for: ✔ Inrush Current ✔ Voltage Swells ✔ Voltage Dips ✔ Transient Overvoltage ✔ Interruptions Measure and Record: ✔ Power and Power Factor ✔ Active/Reactive Energy ✔ Demand ✔ Load Changes (with graph display!) ✔ Voltage and Current ...Before They Catch You! Measure Power and Power Quality on Single to Three-Phase Circuits Quickly and Effortlessly 39 17 Feature 2: QuickSet With QuickSet, all you have to do is just Set, Clamp and Measure! Line frequency Measurement Interval Nominal Voltage Swell Event Dip thresholds against nominal Interruption voltage Transient : : : : : : : Auto Auto Auto 110% 90% 10% ON Testing Parameters Automatically Defined by QuickSet Redefine Thresholds Easily with Intuitive Key Panel P Q A Feature 1: Vector Multimeter For checking the wiring map and vectors in a single window Use the wiring map, vector map and data monitor to c he c k for pr op e r wiring before taking measurements – don’t miss out on important power data just because of minor wiring mistakes! A quick glance at the correct vector map will show you if your wiring is correct Let QuickSet help you take care of all the time-consuming setup procedures. All you need to do is select your circuit, clamp sensor and range, and then let QuickSet do the rest of the work for you. Feature 3: Power & Power Quality Measure all the necessary power parameters simultaneously Get a crystal clear picture of the voltage fluctuation on all channels Check for sudden inrush during motor startup and diagnose breaker trips due to over current all on the same measurement interface. View RMS data for every half cycle over a 30 second period on a large graph display All items are recorded as events so that a quick understanding can be obtained just by viewing the waveform ✓ ✓ ✓ ✓ ✓ Power & Energy Voltage ✓ Demand Current ✓ Load Changes Frequency ✓ THD(voltage) Power Active/Reactive ✓ and Power Factor Energy Voltage Fluctuation (dips and swells) 2 ✓ ✓ ✓ ✓ ✓ Power Quality Inrush Current Voltage Swells Voltage Dips Transient Overvoltage Interruptions Setting Up is as Easy as 1-2-3 Use QuickSet to automatically set the default values for line frequency, nominal voltage, interval, and power quality thresholds for event detection 1 Select your wiring 2 Select your clamp sensor Use the correct vector diagram to check that your wiring is right before measuring, particularly useful when measuring 3-Phase circuits WIRIN G 3 RE C& QuickSet Toggle between screens to customize your measurement settings Make detailed settings on how and when to measure, and customize your level of event detection as desired. EVE NT RE SU A ME Obtain real-time moving data on voltage, current, power, and more! Select from 5 Types of Color-coded Input Terminal Labels to Suit Your Application Region Type 1 2 3 4 5 N Black Blue Black Blue White U1 Red Orange Yellow Black Black U2 Yellow Black Green Red Red U3 Blue Gray Red White Blue Region Japan, U.K. EU (new) China EU (former) N. America Monitor Trends while Recording WAVEFORM Toggle between screens using VIEW key for instantaneous power data lPull Strap Through for Ultimate Portability lAC Adapter for Quick Recharge or Long Recordings lUSB Port for PC Compatibility lPower Switch One-touch switching between graph and numerical data RMS, Phase Angle and Lead and Lag Full-color waveforms and RMS readings l Convenient Stand for Hands-free Viewing VECTOR lRugged and Durable Casing to withstand even the toughest environments and uses 3 Record and Inspect (even while measuring) Find the max, min and average values for any point using the cursor function Auto-Data Compression Lets You Record for up to 125 Days DIP/SWELL RMS Toggle between the trend graphs for a complete analysis of the power situation ✓ Consumed & Regenerated Active Power ✓ Lag and Lead of Reactive Power Get a detailed picture during voltage anomalies fluctuation range for all 3 channels are displayed ENERGY Demand Graph and maximum and average values displayed in one window DEMAND Display events AND their waveforms at the same time DMM Harmonic waveforms of voltage, current and active power to the 50th order Identify Power Quality Problems Inrush current fluctuations are captured in RMS at a fast 10ms sampling rate and displayed across a 30-second window WAVEFORM Switch between voltage and current graphs, and zoom in on the time axis at the touch of a button Toggle between events for a complete picture of the power anomaly Store up to 50 Events DETAIL "I" marks an Inrush Event RMS voltage fluctuations such as swells and dips are clearly displayed at event detection HARMONICS GRAP/LIST INRUSH Record up to 20 graphs in internal memory Scroll down and select to display the finer details of any event RMS 4 Feature 4: Bundled PC Application Software Two Integrated Programs for Data Download and Viewing St andard USB conne c tion let s you download dat a at a snap, and immediately view your measurements with the DataViewer Mobility, Portability Plus Convenient Data Transfer Right to Your PC Feature 5: Compact Design Makes for Long Battery Life 6 Hours of Continuous Use on a Single Recharge Non-volatile Ni-MH rechargeable battery pack keeps important measurement data in memory even after power is turned off. Connect to multiple 3197 units simultaneously using a USB hub Open downloaded recordings with DataViewer to manage and process your captured power data on your PC. Event List A PQA that TRULY fits in the palm of your hand. Standard 3197 Package Fulfills All the Requirements for Checking Voltage Anomalies Time Plot Graph Voltage Cords AC Adapter USB Cable Carrying Case Event Details Event Waveform Settings Rechargeable Battery Pack PC Application To measure current and power, please select one or more of our HIOKI Clamp On Sensors detailed on the back of this catalog. < Measurement Specifications (Guaranteeed Accuracy Period: 1 Year) RMS Voltage and Current Voltage Accuracy Current Accuracy Voltage (1/2) RMS Measurement Accuracy Current (1/2) RMS Measurement Accuracy Frequency Accuracy Active Power Accuracy (for consumption and regeneration) True RMS (200 ms calculation ) ±0.3% rdg. ±0.2%f.s ±0.3% rdg. ±0.2%f.s. + Clamp sensor accuracy True RMS (one cycle calculation refreshed every half cycle) ±0.3% rdg. ±0.2%f.s. True RMS (half-cycle calculation, half-cycle voltage synchronized) ±0.3% rdg. ±0.2%f.s. + Clamp sensor accuracy Effective Measurement range: 45.00 to 66.00 Hz ±0.01 Hz ±1 dgt. (when input is at least 10% of range) ±0.3% rdg. ±0.2% f.s. + clamp-on sensor accuracy (P.F.=1) < Event Detection Voltage Swells (Rise), Voltage Dips (Drop), Interruptions Inrush Current Transient Overvoltage Timer Detection Manual Detection Thresholds Event Recording Lengths Waveform Event voltage fluctuation graph Inrush current graph Maximum Number of Recordable Events RMS value detected using voltage (1/2) measured every half cycle RMS value detected using current (1/2) every half cycle Detection Range: 50 Vrms (±70.7 Vpeak equiv.) or more, 10 to 100 kHz Detect events at preset intervals selectable from OFF, 1, 5, 15 or 30 minutes; 1, 2 or 12 hours; or 1 day Detect events when keys are pressed Set to OFF or to specified value, except for detection of transient overvoltages. (Waveform recording not available for transients.) 20ms before detection + 200ms upon detection + 20ms after detection 0.5s before + 2.5s after detection 0.5s before + 29.5s after detection 50 event waveforms, 20 event voltage fluctuation graphs, 1 inrush current graph, 1000 event counts Reactive Power Accuracy ±1 dgt. of calculation from each measurement value (for lags and leads) Effect of Power Factor Apparent Power Accuracy Power Factor and Displacement Power Factor Accuracy (leading phase indicated) Active or Reactive Energy Consumption Accuracy Demand ±1.0% rdg. (50 /60Hz, P.F.=0.5) ±1 dgt. of calculation from each measurement value ±1 dgt. of calculation from each measurement value (DPF calculated from phase difference between fundamental voltage and current waveforms) Selectable between consumption, regeneration, lag and lead ±1 dgt. applied to active and reactive power measurement accuracy Selectable between active or reactive power ±1 dgt. applied to active and reactive power measurement accuracy Up to 50th (2048 points/window, rectangular) 1st to 15th order ±0.5% rdg. ±0.2% f.s. 16th to 25th order ±1.0% rdg. ±0.3% f.s. 26th to 35th order ±2.0% rdg. ±0.3% f.s. 36th to 45th order ±3.0% rdg. ±0.3% f.s. 46th to 50th order ±4.0% rdg. ±0.3% f.s. (add accuracy of clamp sensor to harmonic current accuracy) Peak Voltage and Current, K Factor, Voltage Unbalance Factor, Max/Min/Ave of Time Series < Input Specifications Single-phase 2-wire (1P2W), single-phase 3-wire (1P3W), three-phase 3-wire (3P3W2M and 3P3W3M), three-phase four-wire (3P4W and 3P4W2.5E) Measurement Line frequency Auto-select (50/60 Hz) Maximum Allowable Input Voltage input terminal: 780 V AC (1103 Vpeak) Voltage Current input terminal: 1.7 V AC (2.4 Vpeak) Voltage input terminal: C ATIII 600 V AC, CATIV 300 V AC (50/60 Hz) Maximum Rated Voltage Current input terminal: per clamp-on sensors used to Ground Simultaneous digital sampling of voltage and current Measurement Method (sampling frequency: 10.24 kHz per channel) Wiring Configurations Voltage Measurement Range 600.0V (Crest factor 2 or less) Current Measurement Range: Manual ranging according to clamp sensor (Crest factor 3 or less) Clamp Sensor Range Clamp Sensor Range 9657-10, 9675 500.0 mA/5.000 A 9661, 9667 (500A) 50.00 A/500.0 A 9694, 9695-02 5.000 A/50.000 A 9669 100.0 A/1.000 kA 9660, 9695-03 10.00 A/100.0 A 9667 (5000A) 500.0 A/5.000 kA Accuracy Harmonic Analysis Orders Harmonic Voltage, Current and Power Accuracy (accuracy is not defined for harmonic power) Other Measurement Items 500mA 300.0W/600.0W/900.0W 100A 60.00kW/120.0kW/180.0kW Power Measurement 5A 3.000kW/6.000kW/9.000kW 500A 300.0kW/600.0kW/900.0kW Range: Depends on combination of current range 10A 6.000kW/12.00kW/18.00kW 1kA 600.0kW/1.200MW/1.800MW and measurement line 50A 30.00kW/60.00kW/90.00kW 5kA 3.000MW/6.000MW/9.000MW 5 < BASIC SPECIFICATIONS Display Display languages Display refresh rate Clock functions Real-Time Clock accuracy Internal Memory Capacity Maximum recording time Interval Settings Demand period Recordable Items 4.7-inch color STN LCD English, Japanese or Chinese (Simplified) Approx. once per second Auto calendar, auto leap year, 24-hour format Within 13 seconds/month 4MB 125 Days AUTO, 1, 5, 15 and 30 min., and 1 hour (AUTO sequentially selects 1, 2, 10, 30 seconds, 1, 5, 15 and 30 min., and 1 hour automatically) 15 min., 30 min. and 1 hour All parameters (incl. max/min/average values) < ENVIRONMENTAL AND SAFETY-RELATED SPECIFICATIONS Operating environment Temperature and humidity Applicable standards Indoors, up to 2000 m (6562-ft.) ASL Storage -10 to 50°C (14 to 122°F), 80% RH or less (non-condensating) Operation 0 to 40°C (32 to 104°F), 80% RH or less (non-condensating) EN61010-1: 2001, Pollution degree 2, Safety Measurement Categories III (600 V) and IV (300 V) (anticipated transient overvoltage 6000 V) EN61326:1997 + A1:1998 + A2:2001 + A3:2003 Class EMC A; EN61000-3-2:2000, EN61000-3-3:1995 + A1:2001 Model 9418-15 AC Adapter or Model 9459 Battery Pack (Maximum rated power: 23 VA (with AC adapter) Power source < INTERFACE SPECIFICATIONS Interface Connection destination USB 2.0 (Full Speed) Computer operating on Windows 2000/XP Continuous Approx. 6 hours operating time (after full charge, with 5 min. auto-off LCD backlight) with battery pack 128 W × 246 H × 63 D mm (5.04”W × 9.69”H × 2.48”D) Dimensions and (including stand) mass Approx. 1.2 kg (42.3 oz.) (with battery pack) < CLAMP ON SENSOR SPECIFICATIONS 9694 3m cord 9660 3m cord 9661 3m cord 9669 3m cord 9667 CAT III 1000V 9695-02 9695-03 MODEL CAT III 300V Measurable conductor diameter CAT III 300V φ15mm CAT III 600V φ46mm CAT III 600V φ55mm, 80×20mm 2m from sensor to circuit 1m from circuit to connector CAT III 300V CAT III 300V φ15mm φ254mm Primary current rating Output voltage Accuracy AC 5A AC 10mV/A AC 100A AC 1mV/A AC 500A AC 1mV/A AC 1000A AC 0.5mV/A AC 500A/5000A AC 500mVf.s. AC 50A AC 10mV/A AC 100A AC 1mV/A Amplitude ±0.3%rdg.±0.02%f.s. ±0.3%rdg.±0.02%f.s. ±0.3%rdg.±0.01%f.s. ±1.0%rdg.±0.01%f.s. ±2.0%rdg.±1.5mV ±0.3%rdg.±0.02%f.s. ±0.3%rdg.±0.02%f.s. (45 to 66 Hz) Phase within ±1° within ±2° within ±1° within ±0.5° within ±1° within ±2° within ±1° (5Hz to 5kHz) (minimum 10% input) Frequency characteristic (accuracy deviation) Max. rated voltage to earth (insulated conductor) within ±1.0% at 40Hz to 5kHz (9669: within ±2.0%) 300Vrms 300Vrms 130A continuous 600Vrms 550A continuous 600Vrms ±3dB at 10Hz to 20kHz 1000Vrms within ±1.0% at 40Hz to 5kHz 300Vrms 60A continuous 130A continuous Maximum allowable 50A continuous input (45 to 66 Hz) Dimensions and weight 46W×135H×21Dmm, 230g Requirements 1000A continuous 10000A continuous 46W×135H×21Dmm, 230g 77W×151H×42Dmm, 360g 100W×188H×42Dmm, 590g Sensor length 910mm, 140g 9445-02/03 AC Adapter (Option) 51W×58H×19Dmm, 50g 9219 Connection Cord (3m; Option) < COMPLETE LIST OF OPTIONS 9660 9661 9667 9669 9694 9695-02 9695-03 9219 9657-10 9675 9438-05 9418-15 9459 9624-50 CLAMP ON SENSOR (100A) CLAMP ON SENSOR (500A) FLEXIBLE CLAMP ON SENSOR (5000A) CLAMP ON SENSOR (1000A) CLAMP ON SENSOR (5A) CLAMP ON SENSOR (50A) CLAMP ON SENSOR (100A) CONNECTION CORD (for the 9695-02/9695-03) CLAMP ON SENSOR (10A) CLAMP ON SENSOR (10A) VOLTAGE CORD (bundled with the standard 3197) AC ADAPTER (bundled with the standard 3197) BATTERY PACK (bundled with the standard 3197) PQA-HiVIEW Pro PC Application Software (available Fall 2006) MODEL 9675 3m cord 9657-10 3m cord CAT III 300V Measurable conductor diameter CAT III 300V φ30mm AC 10A AC 100mV/A ±1.0%rdg.±0.005%f.s. within ±5° φ40mm AC 10A AC 100mV/A ±1.0%rdg.±0.05%f.s. within ±3° Primary current rating Output voltage Amplitude Accuracy (45 to 66 Hz) Phase Accuracy (50/60Hz) Residual Current 1mA (10A on forward and return) 5mA (100A on forward and return) Frequency characteristic within ±5% at 40Hz to 5kHz within ±3% at 40Hz to 5kHz (accuracy deviation) Max. rated voltage to earth Maximum allowable input 300Vrms (insulated conductor) 10A continuous 30A continuous

很抱歉,暂时无法提供与“3197”相匹配的价格&库存,您可以联系我们找货

免费人工找货
HT66F3197
  •  国内价格
  • 1+6.2495
  • 30+6.034
  • 100+5.603
  • 500+5.172
  • 1000+4.9565

库存:0