0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BQ34Z110EVM

BQ34Z110EVM

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    -

  • 描述:

    EVALUATION BOARD FOR BQ34Z110

  • 数据手册
  • 价格&库存
BQ34Z110EVM 数据手册
User's Guide SLUUA15 – October 2012 bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries This evaluation module (EVM) is a complete evaluation system for the bq34z110 wide-range fuel gauge for lead-acid chemistries when combined with an EV2300 USB adapter and Windows®-based PC software, downloadable from the TI.com website. The circuit module includes one bq34z110 integrated circuit (IC) and all other components necessary to monitor and predict capacity in 2 or more series cell Lead Acid battery packs. The circuit module connects directly across the battery. With the EV2300 interface adapter and software, it is possible to read the bq34z110 data registers, program the chip for different pack configurations, log cycling data for further evaluation, and evaluate the overall functionality of the bq34z110 solution under different charge and discharge conditions. 1 2 3 4 5 Contents Features ...................................................................................................................... 2 1.1 Kit Contents ......................................................................................................... 2 1.2 Ordering Information ............................................................................................... 2 bq34z110 Device-Based Circuit Module ................................................................................. 3 2.1 Circuit Module Connections ...................................................................................... 3 2.2 Pin Descriptions .................................................................................................... 3 bq34z110 Circuit Module .................................................................................................. 3 3.1 Choosing SingleCell (1S) or MultiCell operation ............................................................... 3 3.2 Choosing Maximum MultiCell Battery Voltage ................................................................. 3 3.3 Choosing the LED configuration ................................................................................. 4 3.4 Choosing the ALERT configuration .............................................................................. 4 Circuit Module Physical Layouts, Schematic, and Bill of Materials ................................................... 4 4.1 Board Layout ....................................................................................................... 4 4.2 Schematic ........................................................................................................... 8 4.3 bq34z110 Circuit Module Performance Specification Summary ........................................... 11 EVM Hardware and Software Setup .................................................................................... 11 5.1 System Requirements ........................................................................................... 11 5.2 Software Installation .............................................................................................. 11 5.3 Troubleshooting Unexpected Dialog Boxes ................................................................... 11 5.4 Hardware Connection ............................................................................................ 11 5.5 Operation .......................................................................................................... 13 5.6 Calibration Screen ................................................................................................ 16 5.7 I2C Pro (Advanced) Screen ..................................................................................... 17 5.8 Send HDQ Screen ................................................................................................ 18 5.9 bqChem ............................................................................................................ 19 5.10 Related Documentation from Texas Instruments ............................................................ 19 List of Figures 1 bq34z110EVM Layout (Silkscreen) ....................................................................................... 4 2 bq34z110EVM Top Assembly ............................................................................................. 5 3 bq34z110EVM Top Layer .................................................................................................. 5 Impedance Track is a trademark of Texas Instruments, Inc.. Windows is a registered trademark of Microsoft Corporation. SLUUA15 – October 2012 Submit Documentation Feedback bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated 1 Features www.ti.com 4 bq34z110EVM Inner Layer 1 .............................................................................................. 6 5 bq34z110EVM Inner Layer 2 .............................................................................................. 6 6 bq34z110EVM Bottom Layer .............................................................................................. 7 7 bq34z110EVM Schematic 8 9 10 11 12 13 14 ................................................................................................. 8 bq34z110 Circuit Module Connection to Cells and System Load and Charger ................................... 12 Data RAM Screen ......................................................................................................... 14 Data Flash Screen, Gas Gauging Class ............................................................................... 15 Calibration Screen ......................................................................................................... 16 I2C Pro (Advanced) Screen .............................................................................................. 17 Send HDQ Screen ........................................................................................................ 18 bqChem Screen ........................................................................................................... 19 List of Tables 1 1 Ordering Information ........................................................................................................ 2 2 bq34z110EVM Bill of Materials............................................................................................ 9 3 Performance Specification Summary ................................................................................... 11 4 Circuit Module to EV2300 or EV2400 Connections ................................................................... 12 Features • • • 1.1 Kit Contents • • 1.2 Complete evaluation system for the bq34z110 advanced gas gauge with Impedance Track™ technology. Populated circuit module for quick setup Link to software allowing data logging for system analysis bq34z110 circuit module Support documentation Ordering Information Table 1. Ordering Information 2 EVM Part Number Chemistry Configuration Capacity bq34z110EVM Lead Acid 3 V–65 V Any bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated SLUUA15 – October 2012 Submit Documentation Feedback bq34z110 Device-Based Circuit Module www.ti.com 2 bq34z110 Device-Based Circuit Module The bq34z110-based circuit module is a complete and compact example solution of a bq34z110 fuel gauge solution for Lead Acid packs. The circuit module incorporates a bq34z110 fuel gauge IC and various option components and jumpers necessary for evaluation under various battery voltage, LED, and ALERT signal configurations. 2.1 Circuit Module Connections Contacts on the circuit module provide the following connections: • Direct connection to BAT+ and BAT– • The system load and charger connect across BAT+ and PACK– • To the I2C and HDQ serial communication ports • To the ALERT output 2.2 Pin Descriptions PIN NAME BAT + BAT – PACK – SDA SCL GND HDQ ALERT 3 DESCRIPTION Positive battery stack and pack connection Negative battery stack connection Pack negative terminal I2C data signal I2C clock signal Communication and ALERT grounds HDQ serial communication signal ALERT output signal bq34z110 Circuit Module This section contains information on the schematic for the bq34z110 implementation. 3.1 Choosing SingleCell (1S) or MultiCell operation The bq34z110 operates in one of two modes for measuring battery voltage. Place two jumpers on header J5 to select the mode of operation. Refer to the silk screen markings near J5 on the EVM. WARNING Applying a voltage higher than 5 V when jumpers are configured for ≤ 5-V operation is very likely to damage the IC. The ≤ 5-V mode simplifies the circuit from that shown in the schematic. Most of the components shown to the left of the bq34z110 are not necessary. 3.2 Choosing Maximum MultiCell Battery Voltage In the MultiCell > 5-V setup, three levels of maximum battery voltage: 16, 32, and 48 V are selectable on the header J2. Refer to the schematic and silkscreen markings on the EVM for jumper placement. Ideally, the total divider ratio, including the 16.5-kΩ resistor, R28, converts the maximum expected voltage on the battery to something between 0.8 V and 1.0 V at the BAT pin of the gauge. For this reason, test points TP1 and TP2 are provided to customize the top leg of the divider for your application. While the bq34z110 firmware is able to handle battery voltage up to 65 V, voltages above 50 V should never be applied to the EVM. SLUUA15 – October 2012 Submit Documentation Feedback bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated 3 Circuit Module Physical Layouts, Schematic, and Bill of Materials 3.3 www.ti.com Choosing the LED configuration When configuring the data flash registers, choose one of five LED/Comm configuration codes (refer to Table 12 in the bq34z110 datasheet). After reviewing those possibilities, select the jumper pattern desired for the J6 header on the EVM. For single-LED mode, place a jumper on the pair marked A. For four-direct LED mode, place jumpers on A, B, C, and D. For external LEDs using the shift register option, place a single jumper on EXT. In all cases, where one or more LED’s are used, place a jumper across the J1 header to provide power to the LED. 3.4 Choosing the ALERT configuration The pin used to provide the ALERT output depends on the LED mode selected in the LED/Comm data flash register. Refer to Table 13 in the bq34z110 datasheet for a guide to the proper ALERT pin, then place one and only one jumper on the J3 header accordingly. 4 Circuit Module Physical Layouts, Schematic, and Bill of Materials This section contains the board layout, assembly drawings, schematic, and bill of materials for the bq34z110 circuit module. 4.1 Board Layout Figure 1 through Figure 6 show the PCB layers, and assembly drawing for the bq34z110 module. TP4 TP5 J7 TP3 TP8 TP7 TP6 U1 U3 J6 J1 J4 J3 J5 RT1 J2 U2 TB3 SW1 TB1 Figure 1. bq34z110EVM Layout (Silkscreen) 4 bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated SLUUA15 – October 2012 Submit Documentation Feedback Circuit Module Physical Layouts, Schematic, and Bill of Materials www.ti.com D17 D15 D16 D14 D9 R9 R10 R11 R8 1 R36 R35 U3 U1 TP5 J7 Q6 J6 R16 C1 R7 1 TP4 D1 D4 R17 TP3 R12 R18 R20 R22 R23 R24 R19 D5 TP8 TP7 TP6 C4 1 D10 D11 D12 D13 C3 D6 R34 R37 D3 1 J3 J1 Q2 R33 R32 Q1 1 R29 R31 R15 D8 J4 R13 R14 J5 1 R21 D2 R28 C8 J2 TP2 C2 C9 U2 C5 C6 C7 R30 TB3 R5 R6 Q7 RT1 R2 R4 R1 R26 R27 1 R3 R25 R38 TP1 Q5 Q4 Q3 Q8 D7 SW1 R40 R39 TB1 Figure 2. bq34z110EVM Top Assembly Figure 3. bq34z110EVM Top Layer SLUUA15 – October 2012 Submit Documentation Feedback bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated 5 Circuit Module Physical Layouts, Schematic, and Bill of Materials www.ti.com Figure 4. bq34z110EVM Inner Layer 1 Figure 5. bq34z110EVM Inner Layer 2 6 bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated SLUUA15 – October 2012 Submit Documentation Feedback www.ti.com Circuit Module Physical Layouts, Schematic, and Bill of Materials Figure 6. bq34z110EVM Bottom Layer SLUUA15 – October 2012 Submit Documentation Feedback bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated 7 Circuit Module Physical Layouts, Schematic, and Bill of Materials 4.2 www.ti.com Schematic R2 100K R4 165K 1 Q4 BSS138 1 GND REGIN R35 100 R36 R37 100 R34 100 4 100 J2 1 2 3 4 5 6 Q5 BSS84 1 R1 R26 300K .1% R27 300K .1% 16V 3 P3 32V 2 P1 GND R41 27K Q3 2N7002 R39 47 4 Q8 2N7002 C2 J5 5V 8 SH2 BAT + 16.5K .1% 3 Q6 2SK3019 REG25 7 R28 2 J3 D5 Q2 2SK3019 LED CONFIGURATION OPTIONS GND LED5 D13 QTLP610C-3 YEL R12 1.5K LED4 D14 QTLP610C-3 YEL R18 1.5K LED3 D15 QTLP610C-4 GRN R20 1.5K LED2 D16 QTLP610C-4 GRN R22 1.5K J6 Fiducial Marks GND GND P4 P3 P2 P1 U1 SN74HC164PW 1 A REGIN VCC 14 C4 0.1uF 2 B QH 13 TP8 LED1 D17 QTLP610C-4 GRN R23 1.5K 3 QA QG 12 TP7 LED0 D6 R24 1.5K 4 QB QF 11 TP6 10 TP5 QTLP610C-4 GRN TP3 5 QC QE TP4 6 QD ~CLR 9 7 GND CLK 8 GND R32 1M R33 1M GND GND 1 2 3 4 5 6 7 8 9 10 D C B A EXT P2 GND 1 2 3 4 Optional for additional power saving Adjust for minimum current consumption in the application I2C pullups normally implemented in the host. Duplicated here since EV2300 does not provide Optimize for required LED power dissipation Figure 7. bq34z110EVM Schematic 8 bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated SLUUA15 – October 2012 Submit Documentation Feedback Circuit Module Physical Layouts, Schematic, and Bill of Materials www.ti.com 4.2.1 Bill of Materials Table 2 is the BOM for the bq34z110EVM. Table 2. bq34z110EVM Bill of Materials Count RefDes Value Description Size Part Number MFR 2 C1, C8 1uF Capacitor, Ceramic, 6.3V, X7R, 20% 0603 Std Any 6 C2–C7 0.1uF Capacitor, Ceramic, 50V, X7R, 20% 0603 Std Any 1 1 C9 3300 pF Capacitor, Ceramic, 50V, X7R, 20% 0603 Std Any 2 2 D1, D2 AZ23C5V6-7 Diode, Dual, Zener, 5.6 V, 300mW SOT23 AZ23C5V6-7 Diodes 3 3 D12, D13, D14 QTLP610C-3 YEL Diode, LED yellow, 30-mA 0.126 x 0.087 inch QTLP610C-3 Fairchild 8 8 D3–D6, D8, D15–D17 QTLP610C-4 GRN Diode, LED green, 30-mA 0.126 x 0.087 inch QTLP610C-4 Fairchild 1 1 D7 BZT52C5V6S-7 Diode, Zener, 200mW, 5.6V SOD-323 BZT52C5V6S-7 Diodes Inc 3 3 D9, D10, D11 QTLP610C-7 RED Diode, LED red, 30-mA 0.126 x 0.087 inch QTLP610C-7 Fairchild 1 1 J1 PEC02SAAN Header, Male 2-pin, 100mil spacing, 0.100 inch x 2 PEC02SAAN Sullins 1 1 J2 PEC03DAAN Header, Male 2x3-pin, 100mil spacing 0.20 inch x 0.30 PEC03DAAN Sullins 1 1 J3 PEC04DAAN Header, Male 2x4-pin, 100mil spacing 0.20 x 0.40 inch PEC04DAAN Sullins 2 2 J4, J7 22-05-3041 Header, Friction Lock Ass'y, 4-pin Right Angle 0.400 x 0.500 22-05-3041 Molex 1 1 J5 PEC08SAAN Header, Male 8-pin, 100mil spacing, 0.100 inch x 8 PEC08SAAN Sullins 1 1 J6 PEC05DAAN Header, Male 2x5-pin, 100mil spacing 0.100 inch x 5 X 2 PEC05DAAN Sullins 4 4 Q1, Q2, Q6, Q7 2SK3019 MOSFET, Nch, 30V, 100mA, 8 Ohm SC-75A 2SK3019 Rohm 2 2 Q3 Q8 2N7002 MOSFET, N-ch, 60-V, 115-mA, 1.2-Ohms SOT23 2N7000-7-F Diodes Inc 1 1 Q4 BSS138 MOSFET, Nch, 50V, 0.22A, 3.5 Ohm SOT23 BSS138 Fairchild 1 1 Q5 BSS84 MOSFET, P-ch, 50-V, 130-mA, 10-Ohms SOT23 BSS84 Fairchild 3 3 R1, R26, R27 300K 0.1% Resistor, Chip, 0.1W, 0.1%, 25 ppm 0603 RG1608P-304-B-T5 SSM 1 1 R2 100K Resistor, Chip, 1/16-W, 1% 0402 Std Std 2 2 R3, R41 27K Resistor, Chip, 1/16-W, 5% 0402 Std Std 1 1 R4 165K Resistor, Chip, 1/16-W, 1% 0402 Std Std 8 8 R5, R6, R13, R14, R34–R37 100 Resistor, Chip, 1/16W, 5% 0603 Std Any 1 1 R7 2M Resistor, Chip, 1/16-W, 5% 0402 Std Std 14 14 R8–R12, R15–R20, R22–R24 1.5K Resistor, Chip, 1/16-W, 5% 0402 Std Std 1 1 R21 220K Resistor, Chip, 1/16-W, 5% 0402 Std Std 1 1 R25 200 Resistor, Chip, 1/16W, 5% 0603 Std Any 1 1 R28 16.5K .1% Resistor, Chip, 0.1W, 0.1%, 25 ppm 0603 RG1608P-1652-B-T5 SSM 2 2 R29, R31 10K Resistor, Chip, 1/16-W, 5% 0402 Std Std 1 1 R30 .010 75ppm Resistor, Chip, 1/2W, 1%, 75ppm 2010 WSL2010R0100FEA Dale 2 2 R32, R33 1M Resistor, Chip, 1/16-W, 5% 0402 Std Std 1 1 R38 1k Resistor, Chip, 1/16-W, 5% 402 Std Std 2 2 R39-40 47 Resistor, Chip, 1/16-W, 5% 402 Std Std 1 1 RT1 10K Thermistor, NTC, 3-A 0.095 X 0.150 inch 103AT-2 Semitec 1 1 SW1 EVQ-PLHA15 Switch, Push button, Momentary, N.O. Low Profile 0.200 x 0.200 inch EVQ-PLHA15 Panasonic -001 -002 2 6 SLUUA15 – October 2012 Submit Documentation Feedback bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated 9 Circuit Module Physical Layouts, Schematic, and Bill of Materials www.ti.com Table 2. bq34z110EVM Bill of Materials (continued) Count RefDes Value Description Size Part Number MFR 2 TB1, TB3 ED555/3DS Terminal Block, 3-pin, 6A, 3.5mm 0.41 x 0.25 inch ED555/3DS OST 1 TP1 Vscale Hi Test Point, Black, Thru Hole Color Keyed 0.100 x 0.100 inch 5001 Keystone 1 1 TP2 Vscale Lo Test Point, Black, Thru Hole Color Keyed 0.100 x 0.100 inch 5001 Keystone 0 0 TP3–TP8 STD Test Point, 0.020 Hole Std Std 2 2 U1, U3 SN74HC164PW IC, 8-Bit Parallel-Out Serial Shift Registers TSSOP-14 SN74HC164PW TI 1 0 U2 BQ34Z100PW IC, Gas Gauge TSSOP BQ34Z100PW 0 1 U2 BQ34Z110PW IC, Gas Gauge TSSOP BQ34Z110PW 1 1 — 2 2 J4 mate Connector, Female, 0.100 Centers Molex 22-01-3047 8 8 N/A Terminals, Crimp, Tin Molex 05-50-0114 N/A Wire, Insulated 24 Awg, Red, 18 inches (+/-3 inches) (USB_5V) Alpha 1854-3 N/A Wire, Insulated 24 Awg, White, 18 inches (+/-3 inches) (SCL) Alpha 1854-1 N/A Wire, Insulated 24 Awg, Black, 18 inches (+/-3 inches) (GND) Alpha 1854-2 N/A Wire, Insulated 24 Awg, Brown, 18 inches (+/-3 inches) (SDA) Alpha 1854-7 N/A Heatshrink 1" Any Any -001 -002 2 1 PCB, 68 mm x 50 mm x 1 mm PWR111 Any CONNECTOR 1 1 last row Notes: 1. These assemblies are ESD sensitive, observe ESD precautions. 2. These assemblies must be clean and free from flux and all contaminants. Use of no-clean flux is not acceptable. 3. These assemblies must comply with workmanship standards IPC-A-610 Class 2. 4. Reference designators marked with an asterisk ('**') cannot be substituted. All other components can be substituted with equivalent MFG's components. 5. Make one SMBus connector wire assembly for each assembly produced, from J4 mate, 4–24 Awg wires and crimp terminals. Wire colors for pin numbers are listed below. Place a J4 mate on each end of the wire assembly. 6. Install label after final wash. Make text 8 pt font and exactly as shown in the Assembly Number Label table below Assembly Number Label 10 Assembly Number Text PWR111-001 BQ34Z100EVM PWR111-002 BQ34Z100EVM bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated SLUUA15 – October 2012 Submit Documentation Feedback EVM Hardware and Software Setup www.ti.com 4.3 bq34z110 Circuit Module Performance Specification Summary This section summarizes the performance specifications of the bq34z110 circuit module. Table 3. Performance Specification Summary Specification Min Input voltage BAT+ to BAT- in ≤ 5-V mode 5 Typ Max Units 2.7 4 5 V Input voltage BAT+ to BAT- in MultiCell > 5-V mode 5 28 50 V Charge and discharge current 0 2 7 A EVM Hardware and Software Setup This section describes how to install the bq34z110EVM PC software and how to connect the different components of the EVM. 5.1 System Requirements The bq34z110EVSW requires Windows 2000, Windows XP, Windows Vista, or Windows 7. 5.2 Software Installation NOTE: For the latest software archive, contact the Texas Instruments field representative assigned to this device. Install the bq34z110EVSW software with the following steps: 1. Save the archive to a temporary directory. 2. Double-click the executable filename and follow the installer instructions to complete the bq34z110 EVSW installation. If the EV2300 or EV2400 was not previously installed: After bq34z110 EVSW installation, a TI USB DRIVER INSTALLER pops up. Click Yes for the agreement message and follow its instructions. 3. Plug the EV2300 or EV2400 into a USB port. 5.3 Troubleshooting Unexpected Dialog Boxes Users downloading the files must be logged in as the administrator, or must have privileges to install new programs. The driver is not signed, so the administrator must allow installation of unsigned drivers. 5.4 Hardware Connection The bq34z110EVM comprises two hardware components: the bq34z110 circuit module and either the EV2300 or EV2400 PC-interface box. SLUUA15 – October 2012 Submit Documentation Feedback bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated 11 EVM Hardware and Software Setup 5.4.1 www.ti.com Connecting the bq34z110 Circuit Module to a Battery Pack Figure 8 shows how to connect the bq34z110 circuit module to the cells and system load and charger. Figure 8. bq34z110 Circuit Module Connection to Cells and System Load and Charger 5.4.2 PC Interface Connection Configure the hardware to interface with the PC by doing the following: 1. Connect the bq34z110 device-based smart battery to the EV2300 or EV2400 using the provided cable or the connections shown in Table 4. Table 4. Circuit Module to EV2300 or EV2400 Connections bq34z110 Device-Based Battery EV2300 SDA I2C SDA SCL I2C SCL GND GND 2. Connect the PC USB cable to the EV2300 or EV2400 and the PC USB port. The bq34z110EVM-001 is now set up for operation. 12 bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated SLUUA15 – October 2012 Submit Documentation Feedback EVM Hardware and Software Setup www.ti.com 5.5 Operation This section details the operation of the bq34z110 EVSW software. NOTE: Neither the EV2300 or EV2400 driver supports Windows Sleep or Hibernate states. If communicating with the EV2300 or EV2400 or the EVM presents a problem, unplug the USB cable and then plug it back in. 5.5.1 Starting the Program With the EV2300 or EV2400 and the bq34z110EVM connected to the computer, run bq34z110 EVSW from the Desktop Icon or Start | All Programs | Texas Instruments | bq Evaluation Software menu sequence. The Data RAM Screen appears. Data begins to appear once the Refresh (single time scan) button is clicked, or when the Keep Scanning check box is checked. To disable the scan feature, deselect Keep Scanning. The continuous scanning period can be set using the Options and Set Scan Interval menu selections. The range for this interval is 0 ms to 65535 ms. Only items that are selected for scanning are scanned within this period. The bq34z110 EVSW provides a logging function that logs the values that were last scanned by the EVSW. To enable this function, click the Start Logging button; this causes the Keep Scanning button to be selected. When logging is Stopped, the Keep Scanning button is still selected and must be manually unchecked. The logging interval is specified under the Options menu with the maximum value of 65535 ms. The Log interval cannot be smaller than the scan interval because this results in the same value being logged at least twice. SLUUA15 – October 2012 Submit Documentation Feedback bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated 13 EVM Hardware and Software Setup www.ti.com Figure 9. Data RAM Screen Figure 9 shows the Data RAM set along with additional ManuFacturersAccess() command information, such as individual cell measurements. Dragging the splitter bar, the line that separates the Flags/Static data from Data RAM values, changes the height of the Flags/Static Data display. Selecting View then Auto Arrange returns the splitter bar to its original location. 5.5.2 Setting Programmable bq34z110 Options The bq34z110 data flash comes configured according to the default settings detailed in the bq34z110 Wide Range Fuel Gauge with Impedance Track™ Technology Datasheet (SLUSB55). Ensure that the settings are correctly changed to match the pack and application for the bq34z110 solution being evaluated. NOTE: Set these options correctly to get the best performance. 14 bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated SLUUA15 – October 2012 Submit Documentation Feedback EVM Hardware and Software Setup www.ti.com Use Figure 10, the Data Flash Screen to configure the settings. Figure 10. Data Flash Screen, Gas Gauging Class Click on menu option | Data Flash | Read All | to read all the data from the bq34z110 data flash. Write to a data flash location by clicking on the desired location and entering the data. Clicking Enter writes the entire tab of flash data. Writing to a data flash location can also be accomplished by selecting menu option | Data Flash | Write All |. The data flash must be read before any writes are performed to avoid having incorrect data written to the device. The | File | Special Export | menu option allows the data flash to be exported. Save the data flash configuration to a file by selecting | File | Export | and entering a file name. A data flash file also can be retrieved in this way, imported, and written to the bq34z110 using the Write All button. The configuration information of the bq34z110 data is held in the data flash. The bq34z110 allows for an automatic data flash export function, similar to the Data RAM logging function. This feature, when selected using | Options | Auto Export |, exports data flash to a sequential series of files named FilenameNNNNN.gg; where N = a decimal number from 0 to 9. The AutoExport interval is set under the | Options menu | with a minimum value of 15 s. The AutoExport filename is set under the | Options menu |. When a check is next to | AutoExport |, the AutoExport is in progress. The same menu selection is used to turn AutoExport on and off. If the data-flash screen is blank, the bq34z110 used may not be supported by the bqEVSW version in use. An upgrade may be required. SLUUA15 – October 2012 Submit Documentation Feedback bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated 15 EVM Hardware and Software Setup 5.6 5.6.1 www.ti.com Calibration Screen How to Calibrate Calibrate the bq34z110 using appropriate floating power supplies before the cells are attached. Complete the following before the bq34z110 is calibrated: • Connect and measure a 1- to 2-A stable current source from BAT(–) to PACK(–). The positive lead from the current source is connected to PACK(-) simulating a discharge current. • Connect and measure a stable voltage source from BAT(+) to BAT(–). • Measure the temperature near the thermistor. Whether all of the preceding steps are required depends on the type of calibration being performed. 5.6.2 Calibrating the bq34z110 Calibrate the bq34z110 using the following sequential steps: 1. Select the types of calibration to be performed. 2. Enter the measured values for the types of calibration selected (except for offset calibrations). 3. If Temperature Calibration is selected, select the sensor that is to be calibrated. 4. Click the appropriate button to initiate calibration. Figure 11. Calibration Screen 16 bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated SLUUA15 – October 2012 Submit Documentation Feedback EVM Hardware and Software Setup www.ti.com 5.7 5.7.1 2 I C Pro (Advanced) Screen I2C Communication The set of read and write operations over I2C bus are not specific to any gas gauge. These are provided as general-purpose communication tools. 5.7.2 Reprogramming Reprogram the device using the following: • Ensure that the gauge is in Full Access mode. The SS and FAS flags in the Control Status register must both be unasserted (Green). If not, use the appropriate data block codes to command (0x00) to clear the flags. Type default codes of 0414,3672 into the Write I2C Data Block feature to unseal and ffff, ffff for full access, or into the value field of the control register on the Data Ram screen followed by pressing Enter. Stop the scan during this operation to ensure the words are received consecutively. • With scanning enabled, using the Write I2C Data Block feature commands the gauge to stop executing and enter ROM mode. Send data block code 0x000f to command 0x00. If successful, the status at the bottom of the screen changes from Communication OK to Communication Error. • Use the file browser button to locate the desired .senc file, press the Program button. • When programming is complete, pushing the Execute button initiates program execution. Within a few seconds Communication OK appears in the status area. • Close and re-open the Evaluation Software to ensure data file synchronization. Figure 12. I2C Pro (Advanced) Screen SLUUA15 – October 2012 Submit Documentation Feedback bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated 17 EVM Hardware and Software Setup 5.8 www.ti.com Send HDQ Screen When using the HDQ single wire serial communication feature, the mode of the gauge must be changed with a special command. This screen provides a button for this purpose. Note the warning message. The process is not reversible. Once in HDQ mode, the HDQ pro screen is available for testing commands and reprogramming the device. For register scanning and data flash access, use the companion evaluation program for HDQ. Figure 13. Send HDQ Screen 18 bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated SLUUA15 – October 2012 Submit Documentation Feedback EVM Hardware and Software Setup www.ti.com 5.9 bqChem bqChem provides access to the library of previously characterized Lithium-Ion cell chemistries. bqChem also lets you program the chemical database into the gauge. Users can sort by chemical ID or by cell manufacturer. For help identifying the chemistry for the cells, contact the Texas Instruments field representative. Figure 14. bqChem Screen 5.10 Related Documentation from Texas Instruments For related documentation, contact the TI field representative. Documents: bq34z110/bq30z55-R1 SBS 1.1-Compliant Gas Gauge With Impedance Track™ Datasheet EV2300 EVM Interface Board User's Guide EV2400 EVM Interface Board User's Guide SLUUA15 – October 2012 Submit Documentation Feedback Literature Number: SLUSB55 SLUU159 SLUU446 bq34z110EVM Wide-Range Impedance Track™ Enabled Fuel Gauge Solution for Lead-Acid Batteries Copyright © 2012, Texas Instruments Incorporated 19 EVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMS Texas Instruments (TI) provides the enclosed Evaluation Board/Kit/Module (EVM) under the following conditions: The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claims arising from the handling or use of the goods. Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30 days from the date of delivery for a full refund. THE FOREGOING LIMITED WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TO BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. Please read the User's Guide and, specifically, the Warnings and Restrictions notice in the User's Guide prior to handling the product. This notice contains important safety information about temperatures and voltages. For additional information on TI's environmental and/or safety programs, please visit www.ti.com/esh or contact TI. No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or combination in which such TI products or services might be or are used. TI currently deals with a variety of customers for products, and therefore our arrangement with the user is not exclusive. TI assumes no liability for applications assistance, customer product design, software performance, or infringement of patents or services described herein. REGULATORY COMPLIANCE INFORMATION As noted in the EVM User’s Guide and/or EVM itself, this EVM and/or accompanying hardware may or may not be subject to the Federal Communications Commission (FCC) and Industry Canada (IC) rules. For EVMs not subject to the above rules, this evaluation board/kit/module is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end product fit for general consumer use. It generates, uses, and can radiate radio frequency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC or ICES-003 rules, which are designed to provide reasonable protection against radio frequency interference. Operation of the equipment may cause interference with radio communications, in which case the user at his own expense will be required to take whatever measures may be required to correct this interference. General Statement for EVMs including a radio User Power/Frequency Use Obligations: This radio is intended for development/professional use only in legally allocated frequency and power limits. Any use of radio frequencies and/or power availability of this EVM and its development application(s) must comply with local laws governing radio spectrum allocation and power limits for this evaluation module. It is the user’s sole responsibility to only operate this radio in legally acceptable frequency space and within legally mandated power limitations. Any exceptions to this are strictly prohibited and unauthorized by Texas Instruments unless user has obtained appropriate experimental/development licenses from local regulatory authorities, which is responsibility of user including its acceptable authorization. For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 Compliant Caution This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC Interference Statement for Class A EVM devices This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Interference Statement for Class B EVM devices This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. For EVMs annotated as IC – INDUSTRY CANADA Compliant This Class A or B digital apparatus complies with Canadian ICES-003. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Concerning EVMs including radio transmitters This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Concerning EVMs including detachable antennas Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Cet appareil numérique de la classe A ou B est conforme à la norme NMB-003 du Canada. Les changements ou les modifications pas expressément approuvés par la partie responsable de la conformité ont pu vider l’autorité de l'utilisateur pour actionner l'équipement. Concernant les EVMs avec appareils radio Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Concernant les EVMs avec antennes détachables Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le manuel d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur. SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER 【Important Notice for Users of this Product in Japan】 】 This development kit is NOT certified as Confirming to Technical Regulations of Radio Law of Japan If you use this product in Japan, you are required by Radio Law of Japan to follow the instructions below with respect to this product: 1. 2. 3. Use this product in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal Affairs and Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for Enforcement of Radio Law of Japan, Use this product only after you obtained the license of Test Radio Station as provided in Radio Law of Japan with respect to this product, or Use of this product only after you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan with respect to this product. Also, please do not transfer this product, unless you give the same notice above to the transferee. Please note that if you could not follow the instructions above, you will be subject to penalties of Radio Law of Japan. Texas Instruments Japan Limited (address) 24-1, Nishi-Shinjuku 6 chome, Shinjuku-ku, Tokyo, Japan http://www.tij.co.jp 【ご使用にあたっての注】 本開発キットは技術基準適合証明を受けておりません。 本製品のご使用に際しては、電波法遵守のため、以下のいずれかの措置を取っていただく必要がありますのでご注意ください。 1. 2. 3. 電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗室等の試験設備でご使用いただく。 実験局の免許を取得後ご使用いただく。 技術基準適合証明を取得後ご使用いただく。 なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。    上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。 日本テキサス・インスツルメンツ株式会社 東京都新宿区西新宿6丁目24番1号 西新宿三井ビル http://www.tij.co.jp SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER EVALUATION BOARD/KIT/MODULE (EVM) WARNINGS, RESTRICTIONS AND DISCLAIMERS For Feasibility Evaluation Only, in Laboratory/Development Environments. Unless otherwise indicated, this EVM is not a finished electrical equipment and not intended for consumer use. It is intended solely for use for preliminary feasibility evaluation in laboratory/development environments by technically qualified electronics experts who are familiar with the dangers and application risks associated with handling electrical mechanical components, systems and subsystems. It should not be used as all or part of a finished end product. Your Sole Responsibility and Risk. You acknowledge, represent and agree that: 1. 2. 3. 4. You have unique knowledge concerning Federal, State and local regulatory requirements (including but not limited to Food and Drug Administration regulations, if applicable) which relate to your products and which relate to your use (and/or that of your employees, affiliates, contractors or designees) of the EVM for evaluation, testing and other purposes. You have full and exclusive responsibility to assure the safety and compliance of your products with all such laws and other applicable regulatory requirements, and also to assure the safety of any activities to be conducted by you and/or your employees, affiliates, contractors or designees, using the EVM. Further, you are responsible to assure that any interfaces (electronic and/or mechanical) between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electrical shock hazard. You will employ reasonable safeguards to ensure that your use of the EVM will not result in any property damage, injury or death, even if the EVM should fail to perform as described or expected. You will take care of proper disposal and recycling of the EVM’s electronic components and packing materials. Certain Instructions. It is important to operate this EVM within TI’s recommended specifications and environmental considerations per the user guidelines. Exceeding the specified EVM ratings (including but not limited to input and output voltage, current, power, and environmental ranges) may cause property damage, personal injury or death. If there are questions concerning these ratings please contact a TI field representative prior to connecting interface electronics including input power and intended loads. Any loads applied outside of the specified output range may result in unintended and/or inaccurate operation and/or possible permanent damage to the EVM and/or interface electronics. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative. During normal operation, some circuit components may have case temperatures greater than 60°C as long as the input and output are maintained at a normal ambient operating temperature. These components include but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors which can be identified using the EVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during normal operation, please be aware that these devices may be very warm to the touch. As with all electronic evaluation tools, only qualified personnel knowledgeable in electronic measurement and diagnostics normally found in development environments should use these EVMs. Agreement to Defend, Indemnify and Hold Harmless. You agree to defend, indemnify and hold TI, its licensors and their representatives harmless from and against any and all claims, damages, losses, expenses, costs and liabilities (collectively, "Claims") arising out of or in connection with any use of the EVM that is not in accordance with the terms of the agreement. This obligation shall apply whether Claims arise under law of tort or contract or any other legal theory, and even if the EVM fails to perform as described or expected. Safety-Critical or Life-Critical Applications. If you intend to evaluate the components for possible use in safety critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, such as devices which are classified as FDA Class III or similar classification, then you must specifically notify TI of such intent and enter into a separate Assurance and Indemnity Agreement. Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2012, Texas Instruments Incorporated IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily performed. TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components in safety-critical applications. In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and requirements. Nonetheless, such components are subject to these terms. No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties have executed a special agreement specifically governing such use. Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI has specifically designated certain components which meet ISO/TS16949 requirements, mainly for automotive use. Components which have not been so designated are neither designed nor intended for automotive use; and TI will not be responsible for any failure of such components to meet such requirements. Products Applications Audio www.ti.com/audio Automotive and Transportation www.ti.com/automotive Amplifiers amplifier.ti.com Communications and Telecom www.ti.com/communications Data Converters dataconverter.ti.com Computers and Peripherals www.ti.com/computers DLP® Products www.dlp.com Consumer Electronics www.ti.com/consumer-apps DSP dsp.ti.com Energy and Lighting www.ti.com/energy Clocks and Timers www.ti.com/clocks Industrial www.ti.com/industrial Interface interface.ti.com Medical www.ti.com/medical Logic logic.ti.com Security www.ti.com/security Power Mgmt power.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video RFID www.ti-rfid.com OMAP Applications Processors www.ti.com/omap TI E2E Community e2e.ti.com Wireless Connectivity www.ti.com/wirelessconnectivity Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2012, Texas Instruments Incorporated
BQ34Z110EVM 价格&库存

很抱歉,暂时无法提供与“BQ34Z110EVM”相匹配的价格&库存,您可以联系我们找货

免费人工找货