0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SN74F112NSRE4

SN74F112NSRE4

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    SO-16_10.2X5.3MM

  • 描述:

    IC JK TYPE NEG TRG DUAL 16SO

  • 数据手册
  • 价格&库存
SN74F112NSRE4 数据手册
SN74F112 DUAL NEGATIVE-EDGE-TRIGGERED J-K FLIP-FLOP WITH CLEAR AND PRESET SDFS048A – D2932, MARCH 1987 – REVISED OCTOBER 1993 • D OR N PACKAGE (TOP VIEW) Package Options Include Plastic Small-Outline Packages and Standard Plastic 300-mil DIPs 1CLK 1K 1J 1PRE 1Q 1Q 2Q GND description The SN74F112 contains two independent J-K negative-edge-triggered flip-flops. A low level at the preset (PRE) or clear (CLR) inputs sets or resets the outputs regardless of the levels of the other inputs. When PRE and CLR are inactive (high), data at the J and K inputs meeting the setup time requirements is transferred to the outputs on the negative-going edge of the clock pulse. Clock triggering occurs at a voltage level and is not directly related to the rise time of the clock pulse. Following the hold-time interval, data at the J and K inputs may be changed without affecting the levels at the outputs. The SN74F112 can perform as a toggle flip-flop by tying J and K high. 1 16 2 15 3 14 4 13 5 12 6 11 7 10 8 9 VCC 1CLR 2CLR 2CLK 2K 2J 2PRE 2Q The SN74F112 is characterized for operation from 0°C to 70°C. FUNCTION TABLE INPUTS OUTPUTS PRE CLR CLK J K Q L H X X X H Q L H L X X X H H† Q0 L L X X X L H† H H ↓ L L Q0 H H ↓ H L H L H H ↓ L H L H H H ↓ H H Toggle H H H X X Q0 Q0 † The output levels in this configuration are not guaranteed to meet the minimum levels for VOH. Furthermore, this configuration is nonstable; that is, it will not persist when either PRE or CLR returns to its inactive (high) level. Copyright  1993, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 2–1 SN74F112 DUAL NEGATIVE-EDGE-TRIGGERED J-K FLIP-FLOP WITH CLEAR AND PRESET SDFS048A – D2932, MARCH 1987 – REVISED OCTOBER 1993 logic symbol† 1PRE 1J 1CLK 1K 1CLR 2PRE 2J 2CLK 2K 2CLR 4 3 S 5 1J 1 2 15 1Q C1 6 1K 1Q R 10 9 11 2Q 13 12 7 2Q 14 † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. logic diagram, each flip-flop (positive logic) Q Q PRE CLR J K CLK absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡ Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 1.2 V to 7 V Input current range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 30 mA to 5 mA Voltage range applied to any output in the high state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC Current into any output in the low state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 mA Operating free-air temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C ‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTE 1: The input voltage ratings may be exceeded provided the input current ratings are observed. 2–2 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 SN74F112 DUAL NEGATIVE-EDGE-TRIGGERED J-K FLIP-FLOP WITH CLEAR AND PRESET SDFS048A – D2932, MARCH 1987 – REVISED OCTOBER 1993 recommended operating conditions VCC VIH Supply voltage VIL IIK Low-level input voltage IOH IOL High-level output current Low-level output current TA Operating free-air temperature MIN NOM MAX 4.5 5 5.5 High-level input voltage 2 UNIT V V Input clamp current 0 0.8 V – 18 mA –1 mA 20 mA 70 °C electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER VIK VOH VOL II IIH TEST CONDITIONS VCC = 4.5 V, VCC = 4.5 V, II = – 18 mA IOH = – 1 mA VCC = 4.75 V, VCC = 4.5 V, IOH = – 1 mA IOL = 20 mA VCC = 5.5 V, VCC = 5.5 V, VI = 7 V VI = 2.7 V MIN 2.5 TYP† PRE or CLR UNIT – 1.2 V 3.4 V 2.7 0.3 J or K IIL MAX 0.5 V 0.1 mA 20 µA – 0.6 VCC = 5.5 V, VI = 0.5 V –3 CLK mA – 2.4 IOS‡ VCC = 5.5 V, VO = 0 – 60 –150 mA ICC VCC = 5.5 V, See Note 2 12 19 mA † All typical values are at VCC = 5 V, TA = 25°C. ‡ Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second. NOTE 2: ICC is measured with all outputs open, the Q and Q outputs alternately high and the clock input grounded at the time of measurement. timing requirements over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) VCC = 5 V, TA = 25°C fclock Clock frequency tw Pulse duration tsu Setup time, time data before CLK↓ th Hold time time, data after CLK↓ tsu Setup time, inactive state, data before CLK↓§ § Inactive-state state setup time is also referred to as recovery time. POST OFFICE BOX 655303 MIN MAX 0 110 MIN MAX UNIT 0 100 MHz CLK high or low 4.5 5 CLR or PRE low 4.5 5 High 4 5 Low 3 3.5 High 0 0 Low 0 0 CLR or PRE high 4 5 • DALLAS, TEXAS 75265 ns ns ns ns 2–3 SN74F112 DUAL NEGATIVE-EDGE-TRIGGERED J-K FLIP-FLOP WITH CLEAR AND PRESET SDFS048A – D2932, MARCH 1987 – REVISED OCTOBER 1993 switching characteristics (see Note 3) PARAMETER fmax tPLH tPHL tPLH FROM (INPUT) CLK TO (OUTPUT) Q or Q VCC = 5 V, CL = 50 pF, RL = 500 Ω, TA = 25°C VCC = 4.5 V to 5.5 V, CL = 50 pF, RL = 500 Ω, TA = MIN to MAX† MIN TYP 110 130 MAX MIN 1.2 4.6 6.5 1.2 7.5 1.2 4.6 6.5 1.2 7.5 2–4 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 MAX 100 1.2 4.1 6.5 1.2 PRE or CLR Q or Q tPHL 1.2 4.1 6.5 1.2 † For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions. NOTE 3: Load circuits and waveforms are shown in Section 1. UNIT MHz 7.5 7.5 ns ns PACKAGE OPTION ADDENDUM www.ti.com 14-Oct-2022 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan (2) Lead finish/ Ball material MSL Peak Temp Op Temp (°C) Device Marking (3) Samples (4/5) (6) SN74F112D ACTIVE SOIC D 16 40 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 F112 Samples SN74F112DR ACTIVE SOIC D 16 2500 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 F112 Samples SN74F112N ACTIVE PDIP N 16 25 RoHS & Green NIPDAU N / A for Pkg Type 0 to 70 SN74F112N Samples SN74F112NE4 ACTIVE PDIP N 16 25 RoHS & Green NIPDAU N / A for Pkg Type 0 to 70 SN74F112N Samples SN74F112NSR ACTIVE SO NS 16 2000 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 74F112 Samples (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
SN74F112NSRE4 价格&库存

很抱歉,暂时无法提供与“SN74F112NSRE4”相匹配的价格&库存,您可以联系我们找货

免费人工找货