    S016-1240120-FB - DC/DC Converter 12V Input, 1.2 - 5.0V Adjustable Output, 16A or 45W - C&D Technolo...

  • 数据手册
  • 价格&库存
S016-1240120-FB 数据手册
12V Input, 1.2 - 5.0V Adjustable Output, 16A or 45W Features ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Output Current up to 16A or 45W max 12V +5/-10% input Load Regulation ±0.5% Factory set to 1.2V Output with Output Trim up to 5.0V High Efficiency to 90% Back Bias Protection Short Circuit Protection MTBF 4.2 million hours Can sink 8A current, maintaining Output Regulation Programmable, Single Output, 1.1V - 1.85Vout @ 60A DC/DC Converter DC/DC Converter This unit is not fuse protected. User is responsible for providing system protection. Consult factory for application information. Specifications * Input Specifications Input voltage range External input capacitor Output Specifications Standard output voltages and output current 1.2V, 16A 1.25V, 16A 1.5V, 16A 1.8V, 16A 2.5V, 13A 3.3V, 11A 5.0V, 9A ±0.5% ±0.4% 820µF OSCON or equivalent with ESR < 12mΩ 200% of maximum rated current ON-high / OFF-low 90% - 69% Non-isolated 360kHz UL 94V-0 Fusing 10°C to 50°C -40°C to 70°C 0.25 oz 3.6 million hours Regulation range is ± 3% including output voltage set point, line regulation and load regulation over the operating temperature range. See DC Voltage Regulation table on pg 6 for trimming to different voltages 0 to 16A load 12.0V input voltage range See also Input and Output Capacitance table on pg 8 Autorecovery 12.0V +5/-10% Input capacitor capable of ripple current Measured at +Vin pin See ripple current curve on pg 6 and Input and Output Capacitance table on pg 8 S016-12 Load regulation Line regulation External output capacitor Short circuit protection General Specifications Enable ** Efficiency Isolation Switching frequency Approvals and Standards Protection Operating Temperature *** Storage Temperature Weight MTBF See efficiency curves on pg 4 Fixed Unit is not fused. See also derating curves Non-condensing Per RAC PRISM at 50°C ambient and 300 LFM * All specifications are typical at nominal input, full load at 25°C unless otherwise stated. ** Pull below 0.35V to disable the SIP; pull above 2.4V (do not exceed 5.5V) to enable the SIP. *** The output capacitors must meet the max ESR 4.7µF located close to the module ** Output Ceramic Capacitance > 22µF located close to the module Output Transient Response (Dynamic Loading) The output voltages will remain within their regulation limits specified for the load steps defined below. The maximum over/undershoot voltages will not exceed those defined below and will not cause any over or undervoltage detection circuits to activate. The load slew rate will not exceed 10A/µS. Recommended input and output capacitors should be used to meet the Spec. Output Level +5V +3.3V +2.5V +1.8V +1.5 1.25V 1.2V Maximum Load Step 50% 50% 50% 50% 50% 50% 50% Minimum Starting DC Load 0A 0A 0A 0A 0A 0A 0A Voltage Over/Undershoot ±4% ±5% ±5% ±7% ±7% ±10% ±10% 1150 Eglinton Avenue East Toronto, Ontario M3C 1H7 1-866-740-1232 S016_084-S016-00_RevG_Jan12-2005.fm www.cdtechno-cps.com 4607 S.E. International Way Milwaukie, Oregon 97222 1-971-206-2800 8 of 9 12V Input, 1.2 - 5.0V Adjustable Output, 16A or 45W Shock and Vibration Vibration Test Tri-axis random vibration (as generated by pneumatic hammer) Typical vibration conditions: Frequency Range: Vibration Levels: Step Dwell Time: Final Dwell Time: Unit Line Condition: Unit Load Condition: Broadband 20 to 55Grms 10-15 minutes 30-60 minutes Nom Input voltage Full Load Output Programmable, Single Output, 1.1V - 1.85Vout @ 60A DC/DC Converter DC/DC Converter The UUT will survive any specified vibration level or 30Grms minimum without damage and performance will remain within specification limits during vibration testing Shock Test NON-OPERATING/SHIPPING Drop/Impact The power supply, in its individual shipping package, will be capable of withstanding the impacts specified in the International Safe Transit Association’s Integrity Test Procedure 1A – Impact Test. Test System: Orientation: Drop Height: Number of Drops: Free Fall Drop Test System Six (6) faces, three (3) edges, and one (1) corner Height levels determined by product weight (minimum 8 inches (150 lb.), maximum 30 inches (21 lb.)) Ten (10) C&D Technologies, Inc. reserves the right to alter or improve the specification, internal design or manufacturing process at any time, without notice. Please check with your supplier or visit our website to ensure that you have the current and complete specification for your product before use. © C&D Technologies, Inc. 2004 No part of this publication may be copied, transmitted, or stored in a retrieval system or reproduced in any way including, but not limited to, photography, photocopy, magnetic or other recording means, without prior written permission from C&D Technologies, Inc. Instructions for use are available from: www.cdtechno-cps.com 1150 Eglinton Avenue East Toronto, Ontario M3C 1H7 1-866-740-1232 S016_084-S016-00_RevG_Jan12-2005.fm www.cdtechno-cps.com 4607 S.E. International Way Milwaukie, Oregon 97222 1-971-206-2800 9 of 9
S016-1240120-FB 价格&库存

很抱歉,暂时无法提供与“S016-1240120-FB”相匹配的价格&库存,您可以联系我们找货

免费人工找货