0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MAX11254ATJ/V+

MAX11254ATJ/V+

  • 厂商:

    AD(亚德诺)

  • 封装:

    WFQFN32

  • 描述:

    IC ADC 24BIT SIGMA-DELTA 32TQFN

  • 数据手册
  • 价格&库存
MAX11254ATJ/V+ 数据手册
EVALUATION KIT AVAILABLE Click here for production status of specific part numbers. MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface General Description Benefits and Features The MAX11254 is a 6-channel, 24-bit delta-sigma ADC that achieves exceptional performance while consuming very low power. Sample rates up to 64ksps allow precision DC measurements. The MAX11254 communicates via a SPI serial interface and is available in a small (5mm x 5mm) TQFN package. The MAX11254 offers a 6.2nV/√Hz noise programmable gain amplifier (PGA) with gain settings from 1x to 128x. The integrated PGA provides isolation of the signal inputs from the switched capacitor sampling network. The PGA also enables the MAX11254 to interface directly with high-impedance sources without compromising available dynamic range. The MAX11254 operates from a single 2.7V to 3.6V analog supply, or split ±1.8V analog supplies, allowing the analog input to be sampled below ground. The digital supply range is 1.7V to 2.0V or 2.0V to 3.6V, allowing communication with 1.8V, 2.5V, 3V, or 3.3V logic. ●● High Resolution for Industrial Applications that Require a Wide Dynamic Range • 133dB SNR at 50sps • 124dB SNR at 1000sps ●● Longer Battery Life for Portable Applications • 2.2mA Operating Mode Current • 1μA Sleep Current ●● Single or Split Analog Supplies Provide Input Voltage Range Flexibility • 2.7V to 3.6V (Single Supply) or ±1.8V (Split Supply) ●● Enables System Integration • Low Noise, 6.2nV/√Hz PGA with Gains of 1, 2, 4, 8, 16, 32, 64, 128 • 6-Channel, Fully Differential Input ●● Enables On-Demand Device and System Gain and Offset Calibration • User-Programmable Offset and Gain Registers Applications ●● ●● ●● ●● ●● ●● Robust Performance in a Small Package • -40°C to +125°C Operating Temperature Range • TQFN Package, 5mm x 5mm Analog I/O for Programmable Logic Controllers Weigh Scales Pressure Sensors Battery-Powered Instrumentation Automotive ●● AEC-Q100 Qualified, Refer to Ordering Information for List of /V Parts Typical Application Circuit 2.7V TO 3.6V REF 10nF 2.0V TO 3.6V 1µF REFN REFP AVDD 1µF DVDD AIN0P 1nF C0G RSTB CSB AIN0N SCLK MAX11254 DIN DOUT AIN5P RDYB 1nF C0G AIN5N GPO0 GPO1 GPOGND CAPP CAPN CAPREG AVSS 220nF 0603 X7R 1nF C0G RESISTIVE BRIDGE MEASUREMENT CIRCUIT, SPI CONFIGURATION 19-7542; Rev 5; 9/18 DGND µC MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Absolute Maximum Ratings AVDD to AVSS......................................................-0.3V to +3.9V AVDD to DGND.....................................................-0.3V to +3.9V DVDD to DGND.....................................................-0.3V to +3.9V AVSS to DGND...................................................-1.95V to +0.3V DVDD to AVSS......................................................-0.3V to +3.9V AVSS to GPOGND..............................................-1.95V to +0.3V GPOGND to DGND.............................................-1.95V to +0.3V AIN_P, AIN_N,REFP, REFN, CAPP, CAPN to AVSS............................. -0.3V to the lower of +3.9V or (VAVDD + 0.3V) GPO_ to GPOGND..................................... -0.3V to the lower of +3.9V or (VAVDD + 0.3V) CAPREG to AVSS.................................................-0.3V to +3.9V CAPREG to DGND................................................-0.3V to +2.1V All Other Pins to DGND.............................. -0.3V to the lower of +3.9V or (VDVDD + 0.3V) Maximum Continuous Current into Any Pins Except GPOGND Pin....................................................±50mA Maximum Continuous Current into GPOGND Pin..............................................................±100mA Continuous Power Dissipation (TA = +70°C) TQFN (derate 34.5mW/°C above +70°C)................2758.6mW Operating Temperature Range.......................... -40°C to +125°C Junction Temperature.......................................................+150°C Storage Temperature Range............................. -55°C to +150°C Soldering Temperature (reflow)........................................+260°C Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Package Thermal Characteristics (Note 1) TQFN Junction-to-Ambient Thermal Resistance (θJA)…….29°C/W Note 1: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a four-layer board. For detailed information on package thermal considerations, refer to www.maximintegrated.com/thermal-tutorial. Electrical Characteristics (VAVDD = 3.6V, VAVSS = 0V, VDVDD = 2.0V to 3.6V, VREFP - VREFN = VAVDD, DATA RATE = 1ksps, PGA low-noise mode, single-cycle conversion mode (SCYCLE = 1). TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25°C.)(Note 2) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS STATIC PERFORMANCE (Single-Cycle Conversion Mode) Noise Voltage (Referred to Input) Integral Nonlinearity Vn ZERR Zero Drift ZDrift www.maximintegrated.com PGA lownoise mode 0.19 PGA lowpower mode 0.26 PGA gain of 128, single-cycle mode at 12.8ksps data rate PGA lownoise mode 0.83 PGA lowpower mode 1.16 PGA gain of 128, continuous mode at 64ksps data rate PGA lownoise mode 0.83 PGA lowpower mode 1.16 INL Zero Error Full-Scale Error PGA gain of 128, single-cycle mode at 1ksps data rate FSE 3 After system zero-scale calibration After system full-scale calibration (Notes 3 and 4) µVRMS 15 ppm 1 µV 50 nV/°C 2 ppmFSR Maxim Integrated │  2 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Electrical Characteristics (continued) (VAVDD = 3.6V, VAVSS = 0V, VDVDD = 2.0V to 3.6V, VREFP - VREFN = VAVDD, DATA RATE = 1ksps, PGA low-noise mode, single-cycle conversion mode (SCYCLE = 1). TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25°C.)(Note 2) PARAMETER Full-Scale Error Drift Common-Mode Rejection SYMBOL CONDITIONS MIN FSEDrift CMR DC rejection 110 130 50Hz/60Hz rejection (Note 5) 110 130 DC rejection with PGA gain 64 80 105 DC rejection with PGA gain 128 AVDD, AVSS Supply Rejection Ratio DVDD Supply Rejection Ratio PSRRA PSRRD TYP MAX 0.05 UNITS ppmFSR/°C dB 95 DC rejection 73 95 50Hz/60Hz rejection (Note 5) 75 95 DC rejection with PGA gain 128 65 75 DC rejection 105 115 50Hz/60Hz rejection (Note 5) 105 115 DC rejection with PGA gain 128 90 110 dB dB PGA Gain Setting Noise-Spectral Density Gain Error, Not Calibrated Output Voltage Range 1 NSD GERR 128 Low-noise mode 6.2 Low-power mode 10 Gain = 1 0.75 Gain = 2 1.2 Gain = 4 2 Gain = 8 3 Gain = 16 4.5 Gain = 32 6 Gain = 64 5.5 Gain = 128 2 VAVSS + 0.3 VOUTRNG V/V nV/√Hz % VAVDD - 0.3 V MUX Channel-to-Channel Isolation ISOCH-CH DC 140 GPO_ output current = 30mA, GPOGND connected to AVSS 3.5 Per output 30 dB GENERAL-PURPOSE OUTPUTS Resistance (On) RON Maximum Current (On) IMAX www.maximintegrated.com Total from all outputs into GPOGND pin (Note 5) 10 Ω mA 90 mA Maxim Integrated │  3 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Electrical Characteristics (continued) (VAVDD = 3.6V, VAVSS = 0V, VDVDD = 2.0V to 3.6V, VREFP - VREFN = VAVDD, DATA RATE = 1ksps, PGA low-noise mode, single-cycle conversion mode (SCYCLE = 1). TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25°C.)(Note 2) PARAMETER SYMBOL CONDITIONS MIN TYP MAX Ileak1 Current into the GPOGND pin with one individual GPO_ pin connected to 3V 0.4 Ileak3 Current into the GPOGND pin with all GPO_ pins connected to 3V 13 100 TPUPSLP SLEEP state (full power-down) to LDO wake-up VAVDD = 2.7V, VDVDD = 2.0V, CAPREG = 220nF 23 45 TPUPSBY STANDBY state (analog blocks powered down, LDO on) to Active 4 Leakage Current (Off) UNITS nA POWER-UP DELAYS (Note 5) Power-Up Time µs 8 ANALOG INPUTS/REFERENCE INPUTS Direct (PGA bypassed) VAVSS VAVDD PGA VAVSS + 0.4 VAVDD - 1.3 Direct (PGA bypassed) VAVSS VAVDD PGA VAVSS + 0.4 VAVDD - 1.3 0 VREF -VREF +VREF Common-Mode Input Voltage Range, VCM = (VAIN_P + VAIN_N)/2 CMIRNG Input Voltage Range (AIN_P, AIN_N) VIN(RNG) Differential Input Voltage Range (AIN_P – AIN_N) VIN(DIFF) DC Input Leakage IIN_LEAK SLEEP state enabled ±0.1 nA Differential Input Conductance GDIFF Direct (PGA bypassed) ±11.6 µA/V Differential Input Current IDIFF PGA enabled ±1 nA Common-Mode Input Conductance GCM Direct (PGA bypassed) ±1 µA/V Common-Mode Input Current ICM PGA enabled ±10 nA Active state 26 kΩ STANDBY and SLEEP state ±1 nA Direct (PGA bypassed) 2.5 PGA 0.25 Reference Differential Input Resistance RREF Reference Differential Input Current IREF_PD Input Capacitance AIN_P, AIN_N Sampling Rate Reference Voltage Range (REFP, REFN) www.maximintegrated.com CIN CPGAIN Unipolar Bipolar fS VREF(RNG) V V pF 4.096 (Note 6) V MHz VAVDD V Maxim Integrated │  4 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Electrical Characteristics (continued) (VAVDD = 3.6V, VAVSS = 0V, VDVDD = 2.0V to 3.6V, VREFP - VREFN = VAVDD, DATA RATE = 1ksps, PGA low-noise mode, single-cycle conversion mode (SCYCLE = 1). TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25°C.)(Note 2) PARAMETER SYMBOL Differential Reference Voltage Range (REFP – REFN) CONDITIONS VREF MIN TYP 1.5 REFP, REFN Sampling Rate MAX UNITS VAVDD V 4.096 MHz Current 1.1 µA Initial Tolerance ±10 % Drift 0.3 %/°C 0.203 x DATA Hz SENSOR FAULT DETECT CURRENTS DIGITAL SINC FILTER RESPONSE Bandwidth (-3dB) RATE 5/DATA Settling Time (Latency) s RATE LOGIC INPUTS Input Current IDIGILEAK Input Low Voltage VIL Input High Voltage VIH Input Hysteresis GPIO Input Low Voltage GPIO Input High Voltage GPIO Input Hysteresis Leakage current ±1 µA 0.3 x VDVDD V 0.7 x VDVDD VHYS V 200 VIL_GPIO mV 0.3 VIH_GPIO 1.2 VHYS_GPIO V V 20 mV LOGIC OUTPUTS Output Low Level VOL IOL = 1mA Output High Level (RDYB, DOUT, GPIO_ ) VOH IOH = 1mA Floating State Leakage Current Floating State Output Capacitance 0.4 0.9 x VDVDD V IDIGOLEAK ±10 CDIGO V 9 µA pF POWER REQUIREMENTS Negative Analog Supply Voltage VAVSS -1.8 0 V Positive Analog Supply Voltage VAVDD VAVSS + 2.7 VAVSS + 3.6 V Negative I/O Supply Voltage VDGND 0 www.maximintegrated.com V Maxim Integrated │  5 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Electrical Characteristics (continued) (VAVDD = 3.6V, VAVSS = 0V, VDVDD = 2.0V to 3.6V, VREFP - VREFN = VAVDD, DATA RATE = 1ksps, PGA low-noise mode, single-cycle conversion mode (SCYCLE = 1). TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25°C.)(Note 2) PARAMETER SYMBOL CONDITIONS CAPREG not driven by external supply Positive I/O Supply Voltage CAPREG Supply Voltage Analog Supply Current VDVDD VCAPREG IAVDD(CNV) MIN TYP 2.0 V DVDD and CAPREG pins connected together on the circuit board 1.7 Internal LDO enabled 1.8 When CAPREG pin is driven externally, ensure it is connected directly to DVDD pin 1.7 2.0 2.0 Direct 2.2 PGA low-power mode 3.5 4.7 PGA low-noise mode 4.2 5.75 VDVDD = 2.0V, LDO enabled 0.65 1.1 VDVDD = VCAPREG = 2.0V, LDO disabled 0.58 1 IDVDD(CNV) AVDD Sleep Current IAVDD(SLP) VAVDD = 3.6V, VAVSS = 0V, VDVDD = 2.0V DVDD Sleep Current IDVDD(SLP) VDVDD = 2.0V 0.3 AVDD Standby Current IAVDD(SBY) VAVDD = 3.6V, VAVSS = 0V, VDVDD = 2.0V 1.5 VDVDD = 2.0V, LDO enabled 50 VDVDD = VCAPREG = 2.0V, LDO disabled 2.5 UVLO Threshold Low to High UVLO Threshold High to Low www.maximintegrated.com IDVDD(SBY) VLH VHL UNITS 3.6 DVDD Operating Current DVDD Standby Current MAX 3 mA mA µA 2.3 µA µA 175 µA AVDD, DVDD supply undervoltage lockout 0.8 CAPREG supply undervoltage lockout 0.65 1.0 1.35 AVDD, DVDD supply undervoltage lockout 0.6 1.1 1.55 CAPREG supply undervoltage lockout 0.45 0.95 1.3 1.2 V 1.65 V V Maxim Integrated │  6 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Electrical Characteristics (continued) (VAVDD = 3.6V, VAVSS = 0V, VDVDD = 2.0V to 3.6V, VREFP - VREFN = VAVDD, DATA RATE = 1ksps, PGA low-noise mode, single-cycle conversion mode (SCYCLE = 1). TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25°C.)(Note 2) PARAMETER SYMBOL UVLO Hysteresis VHYS UVLO Delay Low to High or High to Low TDEL UVLO Glitch Suppression TP CONDITIONS MIN TYP AVDD, DVDD supply undervoltage lockout 4 CAPREG supply undervoltage lockout 5 AVDD, DVDD supply undervoltage lockout 10 CAPREG supply undervoltage lockout 3.5 AVDD, DVDD supply undervoltage lockout 10 CAPREG supply undervoltage lockout 10 MAX UNITS % µs ns SPI 24B DATA READ RDYB tCSW tR1 tCSS0 CSB tCSH1 tCH SCLK tCL 1 8 tDS DIN ‘X’ ‘1’ ‘1’ 9 DOUT 31 24b data tDH ‘0’ ‘0’ ‘1’ ‘1’ ‘0’ ‘1’ tDOE HIGH-Z tCSS1 tCP tDOT ‘X’ MSB tDOH tDOD LSB HIGH-Z Figure 1. SPI Timing Diagram www.maximintegrated.com Maxim Integrated │  7 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface SPI Timing Requirements (VAVDD = 3.6V, VAVSS = 0V, VDVDD = 1.7V to 3.6V, TA = TMIN to TMAX, unless otherwise noted. For output pins, CLOAD = 20pF.) PARAMETER SCLK Frequency SYMBOL fSCLK SCLK Clock Period tCP SCLK Pulse-Width High tCH SCLK Pulse-Width Low tCL CONDITIONS Note 5 applies to minimum value MIN 0.05 TYP MAX UNITS 8 MHz 125 ns Allow 40% duty cycle 50 ns Allow 40% duty cycle 50 ns CSB Low Setup tCSS0 CSB low to 1st SCLK rise setup 40 ns CSB High Setup tCSS1 CSB rising edge to SCLK rising edge setup time (Note 5) 40 ns SCLK Fall Hold tCSH1 SCLK falling edge to CSB rising edge, SCLK hold time 3 ns CSB Pulse Width tCSW Minimum CSB pulse-width high 40 ns DIN Setup tDS DIN setup to SCLK rising edge 40 ns DIN Hold tDH DIN hold after SCLK rising edge 0 ns DOUT Transition tDOT DOUT transition valid after SCLK fall (Note 5) DOUT Hold tDOH Output hold time remains valid after SCLK fall (Note 5) DOUT Disable tDOD CSB rise to DOUT disable (Note 5) CSB Fall to DOUT Valid tDOE (Note 5) RDYB transitions from ‘0’ to ‘1’ on rising edge of SCLK when LSB-1 of DATA is shifted onto DOUT (Note 5) SCLK Rise to RDYB ‘1’ RSTB Fall to RDYB ‘1’ tR1 tR2 40 3 ns ns 25 ns 0 40 ns 0 40 ns RDYB transition from ‘0’ to ‘1’ on falling edge of RSTB, internal clock mode (Note 5) 300 ns RDYB transition from ‘0’ to ‘1’ on falling edge of RSTB, external clock mode, clock frequency = fCLK (Note 5) 2/fCLK s Note 2: Limits are 100% tested at TA = +25°C, unless otherwise noted. Limits over the operating temperature range and relevant supply voltage range are guaranteed by design and characterization. Note 3: Full-scale error includes errors from gain and offset or zero-scale error. Note 4: ppmFSR is parts per million of full-scale range. Note 5: These specifications are guaranteed by design, characterization, or SPI protocol. Note 6: Reference common mode (VREFP + VREFN)/2 ≤ (VAVDD + VAVSS)/2 + 0.1V. www.maximintegrated.com Maxim Integrated │  8 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Typical Operating Characteristics (VAVDD = +3.6V, VAVSS = 0V, VDVDD = +2.0V, VREFP - VREFN = VAVDD; TA = TMIN to TMAX, LDO enabled, PGA enabled, unless otherwise noted. Data rate = 1ksps, single-cycle conversion mode (SCYCLE = 1) Typical values are at TA = +25°C.) INL vs. INPUT VOLTAGE 4 5 INL (ppm) 2 1 0 0.40 TA = +25°C 2 TA = -40°C -2 1 0 -2 -3 -3 -4 -4 -3.5 -2.5 -1.5 -0.5 0.5 1.5 2.5 -2.5 -1.5 0.10 0.5 -0.5 0.5 1.5 2.5 0 3.5 toc04 OFFSET ERROR vs. TEMPERATURE 0 0.5 1 toc05 5 TA = +125°C 0.4 0.2 -10 BYPASS MODE -15 0.1 -20 0.0 -25 2.5 toc06 BYPASS MODE 0 OFFSET ERROR (LSB) OFFSET ERROR (LSB) -5 0.3 2 OFFSET ERROR vs. AVDD VOLTAGE PGA GAIN = 128V/V NOISE (µVRMS) 1.5 COMMON-MODE VOLTAGE (V) DIFFERENTIAL INPUT (V) DIFFERENTIAL INPUT (V) INPUT-REFERRED NOISE vs. TEMPERATURE TA = +125°C 0.20 0.00 -3.5 3.5 TA = +25°C 0.30 TA = -40°C TA = +125°C -5 -5 toc03 PGA GAIN = 128V/V -1 -1 0.50 TA = -40°C 3 TA = +125°C toc02 PGA GAIN = 4V/V 4 TA = +25°C 3 INL (ppm) toc01 BYPASS MODE INPUT-REFERRED NOISE vs. COMMON-MODE VOLTAGE NOISE (µVRMS) 5 INL vs. INPUT VOLTAGE TA = -40°C -5 -10 TA = +25°C -15 PGA = 4 0 50 100 150 -20 -40 -25 -10 5 TEMPERATURE (°C) OFFSET ERROR vs. AVDD VOLTAGE 3 3.3 TA = -40°C toc08 OFFSET ERROR vs. VREFP - VREFN 5 TA = +25°C -23 -5 TA = -40°C -10 TA = +25°C -20 -30 TA = +125°C -40 TA = +125°C 3 3.3 VAVDD (V) www.maximintegrated.com 3.6 TA = -40°C -15 TA = +25°C -25 -35 TA = +125°C -45 -55 -50 -28 toc09 PGA = 4 0 -18 3.6 VAVDD (V) OFFSET ERROR vs. VREFP - VREFN 10 OFFSET ERROR (LSB) OFFSET ERROR (LSB) toc07 -13 2.7 2.7 TEMPERATURE (°C) BYPASS MODE PGA = 4 -8 20 35 50 65 80 95 110 125 OFFSET ERROR (LSB) -50 1.5 2.2 VREFP - VREFN (V) 2.9 3.6 1.5 2.2 2.9 3.6 VREFP - VREFN (V) Maxim Integrated │  9 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Typical Operating Characteristics (continued) (VAVDD = +3.6V, VAVSS = 0V, VDVDD = +2.0V, VREFP - VREFN = VAVDD; TA = TMIN to TMAX, LDO enabled, PGA enabled, unless otherwise noted. Data rate = 1ksps, single-cycle conversion mode (SCYCLE = 1) Typical values are at TA = +25°C.) INTERNAL OSCILLATOR FREQUENCY vs. TEMPERATURE toc10 8.20 8.5 8.4 FREQUENCY (MHz) 8.3 8.3 8.2 8.2 8.19 8.19 8.19 8.18 8.18 8.17 8.1 8.1 8.17 8.0 8.16 -40 -25 -10 5 20 35 50 65 80 95 110 125 1.8 toc13 -100 -100 -105 TA = +125°C -115 100 1000 10000 100000 1000000 SLEEP CURRENT vs. TEMPERATURE TA = -40°C IAVDD_SLEEP 1 1000 10000 IDVDD_SLEEP 20 35 50 65 80 95 110 125 TEMPERATURE (°C) www.maximintegrated.com IAVDD 2.5 IDVDD 1.5 -40 -25 -10 5 100000 1000000 20 35 50 65 80 95 110 125 TEMPERATURE (°C) toc17 10 1 ACTIVE CURRENT vs. AVDD VOLTAGE 6 toc18 PGA LOW NOISE 5.5 IDVDD_STBY IAVDD_STBY -40 -25 -10 5 3.5 0.5 STANDBY CURRENT vs. TEMPERATURE 0.5 0 4.5 ACTIVE CURRENT (mA) STANDBY CURRENT (µA) 2 toc15 PGA LOW NOISE FREQUENCY ON DVDD (Hz) 100 3.5 -0.5 100 2.5 1.5 5.5 TA = +25°C 10 toc16 3 ACTIVE CURRENT vs. TEMPERATURE -130 FREQUENCY ON AVDD (Hz) 2.5 toc14 TA = +125°C -110 -125 -120 10 2 VDVDD (V) -120 -115 8.16 2 fsample = 64ksps Bypass Mode VDVDD = 2.1V ±50mVP-P -105 TA = +25°C -110 SLEEP CURRENT (µA) 1.9 PSRR vs. FREQUENCY ON DVDD PSRR (dB) PSRR (dB) -95 8.18 8.17 1.7 fsample = 64ksps BYPASS MODE VAVDD = 3.3V ±50mVP-P TA = -40°C -90 8.18 VDVDD (V) PSRR vs. FREQUENCY ON AVDD -85 8.19 8.17 TEMPERATURE (°C) 3 LDO ENABLED 8.20 ACTIVE CURRENT (mA) FREQUENCY (MHz) 8.4 INTERNAL OSCILLATOR FREQUENCY vs. DVDD VOLTAGE toc12 8.20 LDO DISABLED 8.20 FREQUENCY (MHz) 8.5 INTERNAL OSCILLATOR FREQUENCY vs. DVDD VOLTAGE toc11 5 TA = +125°C 4.5 4 TA = +25°C TA = -40°C 3.5 3 -40 -25 -10 5 20 35 50 65 80 95 110 125 TEMPERATURE (°C) 2.7 3 3.3 3.6 VAVDD (V) Maxim Integrated │  10 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Typical Operating Characteristics (continued) (VAVDD = +3.6V, VAVSS = 0V, VDVDD = +2.0V, VREFP - VREFN = VAVDD; TA = TMIN to TMAX, LDO enabled, PGA enabled, unless otherwise noted. Data rate = 1ksps, single-cycle conversion mode (SCYCLE = 1) Typical values are at TA = +25°C.) SLEEP CURRENT vs. AVDD VOLTAGE STANDBY CURRENT vs. AVDD VOLTAGE toc19 2.5 ACTIVE CURRENT vs. DVDD VOLTAGE toc20 2.8 TA = +125°C 1.5 1 TA = -40°C 0.5 ACTIVE CURRENT (µA) 2 STANDBY CURRENT (µA) SLEEP CURRENT (µA) TA = +125°C 2.3 1.8 TA = -40°C 1.3 0.8 TA = +25°C TA = +25°C 2.7 3 3.3 3 TA = +125°C 710 690 670 650 SLEEP CURRENT vs. DVDD VOLTAGE 3.3 3.6 2 toc22 STANDBY CURRENT vs. DVDD VOLTAGE 90 STANDBY CURRENT (µA) TA = -40°C 1 0.8 TA = +125°C 0.6 2 3.6 toc23 LDO ENABLED 80 70 60 TA = +25°C TA = -40°C 2.4 2.8 3.2 40 3.6 2 2.4 2.8 VDVDD (V) OUTPUT SPECTRUM SHORTED INPUTS THD vs. FREQUENCY toc24 0 BYPASS MODE SINGLE CYCLE CONTINOUS fsample = 1ksps toc25 BYPASS MODE CONTINUOUS fsample = 8ksps -20 -120 toc26 BYPASS MODE SINGLE CYCLE CONTINUOUS fsample = 1ksps 120 119 119 -60 SNR (dB) -60 -100 3.6 SNR vs. TEMPERATURE 120 -40 -80 3.2 VDVDD (V) THD (dB) AMPLITUDE (dB) 3.2 TA = +25°C 0.2 -40 2.8 50 0.4 -20 2.4 TA = +125°C 1.2 TA = -40°C VDVDD (V) LDO DISABLED 1.4 0 TA = +25°C 630 VAVDD (V) VAVDD (V) SLEEP CURRENT (µA) 730 toc21 590 2.7 3.6 LDO ENABLED 610 0.3 0 750 -80 118 118 117 117 -100 -140 116 -120 -160 116 115 -140 -180 0 100 200 300 FREQUENCY (Hz) www.maximintegrated.com 400 500 0 200 400 600 FREQUENCY (Hz) 800 1000 -40 10 60 110 TEMPERATURE (ºC) Maxim Integrated │  11 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface CSB DOUT DGND DVDD RSTB CAPREG GPIO1/SYNC 32 31 30 29 28 27 26 25 + DIN Pin Configuration RDYB 1 24 GPO0 SCLK 2 23 GPIO0/CLK AVDD 3 22 GPO1 AVSS 4 21 GPOGND REFP 5 20 CAPP REFN 6 19 CAPN AIN0N 7 18 AIN5P AIN0P 8 17 AIN5N MAX11254 9 10 11 12 13 14 15 16 AIN1N AIN1P AIN2N AIN2P AIN3N AIN3P AIN4N AIN4P EP Pin Description PIN NAME FUNCTION 1 RDYB Active-Low Data Ready Output. RDYB goes low when a new conversion result is available in the data register. When a read operation of a full output word completes, RDYB returns high. RDYB is always driven. 2 SCLK SPI Serial Clock Input 3 AVDD Positive Analog Supply 4 AVSS Negative Analog Supply 5 REFP Positive Reference Input 6 REFN Negative Reference Input 7 AIN0N Negative Analog Input 0 8 AIN0P Positive Analog Input 0 9 AIN1N Negative Analog Input 1 10 AIN1P Positive Analog Input 1 www.maximintegrated.com Maxim Integrated │  12 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Pin Description (continued) PIN NAME FUNCTION 11 AIN2N Negative Analog Input 2 12 AIN2P Positive Analog Input 2 13 AIN3N Negative Analog Input 3 14 AIN3P Positive Analog Input 3 15 AIN4N Negative Analog Input 4 16 AIN4P Positive Analog Input 4 17 AIN5N Negative Analog Input 5 18 AIN5P Positive Analog Input 5 19 CAPN PGA Filter Input. Connect 1nF C0G capacitor between CAPP and CAPN. 20 CAPP PGA Filter Input. Connect 1nF C0G capacitor between CAPP and CAPN. 21 GPOGND 22 GPO1 Analog Switch Normally Open Terminal/General-Purpose Output 1. Register controlled, close position connects GPO1 to GPOGND. Current sink only. 23 GPIO0/ CLK General-Purpose I/O Pin (Default) or External Clock Signal for the Device. When external clock mode is selected, provide a digital clock signal at this pin. The MAX11254 is specified with a clock frequency of 8.192MHz. Clock frequencies below 8.192MHz are supported. The data rate and digital filter notch frequencies scale with the clock frequency. 24 GPO0 Analog Switch Normally Open Terminal/General-Purpose Output 0. Register controlled, close position connects GPO0 to GPOGND. Current sink only. 25 GPIO1/ SYNC Synchronization Input (default) or General-Purpose I/O Pin. SYNC resets both the digital filter and the modulator. Connect SYNC from multiple MAX11254s in parallel to synchronize more than one ADC to an external trigger. 26 CAPREG 1.8V Subregulator Output. Connects to DVDD when driven externally by a 1.8V supply. Connect a 220nF or larger capacitor between CAPREG and DGND. 27 RSTB Active-Low Power-On-Reset Input 28 DVDD Digital Power Supply, 1.7V to 3.6V 29 DGND Digital Ground 30 DOUT Serial Data Output 31 CSB Active-Low Chip-Select Input 32 DIN Serial Data Input — EP Exposed Pad. Connect EP directly to AVSS plane. www.maximintegrated.com Analog Switch/General-Purpose Output, GND Terminal Maxim Integrated │  13 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Functional Diagram AVDD AVSS AIN0P AIN0N AIN1P AIN1N AIN2P AIN2N AIN3P AIN3N AIN4P AIN4N AIN5P AIN5N DVDD DGND AVDD CLOCK GENERATOR 1µA DELTA-SIGMA ADC PGA MUX TIMING DIGITAL FILTER RSTB CSB SCLK DIN DOUT RDYB GPIO0/CLK GPIO1/SYNC SERIAL INTERFACE GPOGND 1µA 1.8V REGULATOR AVSS CAPP CAPN REFP REFN CAPREG GPO0 Detailed Description Voltage Reference Inputs The fourth order delta-sigma modulator is unconditionally stable and measures six differential input voltages. The modulator is monitored for overrange conditions, which are reported in the status register. The digital filter is a variable decimation-rate SINC filter with overflow monitoring reported in the status register. Analog Inputs The MAX11254 is a 24-bit delta-sigma ADC that achieves exceptional performance consuming minimal power. Sample rates up to 64ksps support precision DC measurements. The built-in sequencer supports scanning of selected analog channels, programmable conversion delay, and math operations to automate sensor monitoring. The programmable gain differential amplifier (PGA) is low noise and is programmable from 1 to 128. The PGA buffers the modulator and provides a high-impedance input to the analog channels. System Clock The MAX11254 incorporates a highly stable internal oscillator that provides the system clock. The system clock is trimmed to 8.192MHz, providing digital and analog timing. The MAX11254 also supports an external clock mode. www.maximintegrated.com GPO1 The MAX11254 provides differential inputs REFP and REFN for an external reference voltage. Connect the external reference directly across the REFP and REFN pins to obtain the differential reference voltage. The VREFP voltage should always be greater than the VREFN voltage, and the common-mode voltage range is between 0.75V and VAVDD - 0.75V. The MAX11254 measures six pairs of differential analog inputs (AIN_P, AIN_N) in direct connection or buffered through the PGA. See the CTRL2: Control Register 2 (Read/Write) table for programming and enabling the PGA or direct connect mode. The default configuration is direct connect, with the PGA powered down. Bypass/Direct Connect The MAX11254 offers the option to bypass the PGA and route the analog inputs directly to the modulator. This option lowers the power of the device since the PGA is powered down. Maxim Integrated │  14 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Programmable Gain Amplifier (PGA) The integrated PGA provides gain settings from 1x to 128x. (Figure 2). Direct connection is available to bypass the PGA and directly connect to the modulator. The PGA’s absolute input voltage range is CMIRNG and the PGA output voltage range is VOUTRNG, as specified in the Electrical Characteristics. Note that linearity and performance degrade when the specified input common-mode voltage of the PGA is exceeded. The input common-mode range and output common-mode range are shown in Figure 3. The following equations describe the relationship between the analog inputs and PGA output. AINP = Positive input to the PGA AINN = Negative input to the PGA CAPP = Positive output of PGA CAPN = Negative output of PGA VCM = Input common mode GAIN = PGA gain VREF = ADC reference input voltage VIN = VAINP - VAINN Note: Input voltage range is limited by the reference voltage as described by VIN ≤ ±VREF/GAIN VCM = (V AINP + V AINN) 2 VCAPP =VCM + GAIN × (V AINP = VCAPN VCM − GAIN × (VCM − Input Voltage Range The ADC input range is programmable for bipolar (-VREF to +VREF) or unipolar (0 to VREF) ranges. The U/B bit in the CTRL1 register configures the MAX11254 for unipolar or bipolar transfer functions. Data Rates Table 1 lists the available data rates for the MAX11254, RATE[3:0] setting of the conversion command (see the Modes and Registers section). The single-cycle mode has an overhead of 48 digital master clocks that is approximately 5.86µs for a typical digital master clock frequency of 8.192MHz. The single-cycle effective column contains the data rate values including the 48 clock startup delays. The 48 clocks are required to stabilize the modulator at startup. In continuous conversion mode, the output data rate is five times the single-cycle rate up to a maximum of 64ksps. During continuous conversions, the output sample data requires five 24-bit cycles to settle to a valid conversion from an input step, PGA gain changes, or a change of input channel through the multiplexer. If self-calibration is used, 48 additional master clocks are required to process the data per conversion. Likewise, system calibration takes an additional 48 master clocks to complete. If both self and system calibration are used, it takes an additional 80 master clocks to complete. If self and/or system calibration are used, the effective data rate will be reduced by these additional clock cycles per conversion. Noise Performance − The MAX11254 provides exceptional noise performance. SNR is dependent on data rate, PGA gain, and power mode. Bandwidth is reduced at low data rates; both noise and SNR are improved proportionally. Tables 2 and 3 summarize the noise performance for both single-cycle VCM ) V AINN ) AINP R3 A1 CAPP R1 R2 CCAPP/N (C0G capacitor) R1 R3 CAPN A2 AINN Figure 2. Simplified Equivalent Diagram of the PGA www.maximintegrated.com Maxim Integrated │  15 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Table 1. Available Programmable Data Rates DATA RATE (sps) SINGLE CYCLE CONVERSION ONLY CONVERSION PLUS SELFCALIBRATION* CONVERSION PLUS SELF-CALIBRATION PLUS SYSTEM CALIBRATION* RATE[3:0] CONTINUOUS 0000 1.9 50 50.01 49.99 49.98 0001 3.9 62.5 62.51 62.48 62.47 0010 7.8 100 99.98 99.92 99.88 0011 15.6 125 124.95 124.86 124.80 0100 31.2 200 199.80 199.57 199.41 0101 62.5 250 249.66 249.29 249.05 0110 125 400 398.98 398.05 397.44 0111 250 500 498.34 496.89 495.93 1000 500 800 796.11 792.41 789.97 1001 1000 1000 991.86 986.13 982.35 1010 2000 1600 1578.72 1564.26 1554.77 1011 4000 2000 1974.16 1951.60 1936.84 1100 8000 3200 3114.26 3058.48 3022.39 1101 16000 4000 3895.78 3808.89 3753.08 1110 32000 6400 6135.27 5922.49 5788.64 1111 64000 12800 11776.90 11017.10 10562.79 *The effective data rate is lower when the calibration is enabled due to additional MAC (multiply/accumulate) operations required after the conversion is complete to perform the calibration adjustment. ANALOG INPUTS PGA OUTPUT VAVDD VAVDD - 0.3V OUTPUT VOLTAGE RANGE = GAIN x INPUT VOLTAGE RANGE VAVDD - 1.3V COMMON-MODE INPUT VOLTAGE INPUT VOLTAGE RANGE VAVSS + 0.4V ≤ VREF VAVSS + 0.3V VAVSS Figure 3. Analog Input Voltage Range Compared to PGA Output Range www.maximintegrated.com Maxim Integrated │  16 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Table 2. Noise vs. PGA Mode and Gain (Single-Cycle Conversion) SINGLE-CYCLE CONVERSION MODE INPUT-REFERRED NOISE VOLTAGE (µV RMS) vs. PGA GAIN SETTING DATA RATE (sps) LP LN LP LN LP LN LP LN LP LN LP LN LP LN LP LN 50 0.81 0.58 0.38 0.27 0.18 0.13 0.10 0.07 0.09 0.07 0.08 0.06 0.08 0.06 0.08 0.06 62.5 0.88 0.63 0.48 0.34 0.21 0.15 0.12 0.09 0.09 0.07 0.08 0.06 0.08 0.05 0.08 0.05 100 1.18 0.84 0.61 0.44 0.30 0.21 0.17 0.12 0.12 0.08 0.09 0.07 0.09 0.07 0.10 0.07 125 1.24 0.89 0.59 0.42 0.31 0.22 0.18 0.13 0.12 0.08 0.10 0.07 0.10 0.07 0.10 0.07 200 1.38 0.99 0.68 0.49 0.35 0.25 0.21 0.15 0.15 0.10 0.12 0.08 0.11 0.08 0.11 0.08 250 1.38 0.99 0.72 0.52 0.39 0.28 0.23 0.16 0.16 0.11 0.13 0.09 0.12 0.09 0.12 0.09 400 1.63 1.16 0.85 0.61 0.45 0.32 0.27 0.19 0.19 0.14 0.16 0.12 0.15 0.11 0.16 0.11 500 1.79 1.28 0.93 0.66 0.48 0.34 0.29 0.21 0.21 0.15 0.18 0.13 0.17 0.12 0.18 0.13 800 2.12 1.51 1.10 0.79 0.61 0.43 0.36 0.26 0.27 0.20 0.24 0.17 0.23 0.16 0.23 0.16 1,000 2.38 1.70 1.25 0.89 0.69 0.49 0.41 0.29 0.31 0.22 0.27 0.19 0.26 0.18 0.26 0.19 1,600 3.21 2.29 1.67 1.19 0.89 0.64 0.56 0.40 0.41 0.29 0.36 0.26 0.35 0.25 0.35 0.25 2,000 3.76 2.69 1.95 1.39 1.04 0.74 0.65 0.47 0.48 0.34 0.43 0.30 0.41 0.29 0.42 0.30 3,200 4.41 3.15 2.28 1.63 1.25 0.89 0.78 0.55 0.58 0.41 0.51 0.36 0.49 0.35 0.49 0.35 4,000 5.18 3.70 2.68 1.91 1.48 1.06 0.91 0.65 0.69 0.49 0.60 0.43 0.58 0.41 0.59 0.42 6,400 7.34 5.24 3.83 2.73 2.08 1.48 1.29 0.92 0.98 0.70 0.86 0.61 0.81 0.58 0.83 0.59 12,800 10.84 7.74 5.59 3.99 3.01 2.15 1.85 1.32 1.37 0.98 1.23 0.88 1.17 0.83 1.16 0.83 1 2 4 8 16 32 64 128 LP = Low Power, LN = Low Noise www.maximintegrated.com Maxim Integrated │  17 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Table 3. Noise vs. PGA Mode and Gain (Continuous Conversion) CONTINUOUS CONVERSION MODE INPUT-REFERRED NOISE VOLTAGE (µV RMS) vs. PGA GAIN SETTING DATA RATE (sps) LP LN LP LN 15.6 0.45 0.32 0.20 31.2 0.58 0.41 0.26 62.5 0.68 0.48 125 0.86 250 1.14 1 2 4 8 16 32 64 128 LP LN LP LN LP LN LP LN LP LN LP LN 0.14 0.11 0.08 0.06 0.04 0.04 0.03 0.03 0.02 0.03 0.02 0.03 0.02 0.18 0.13 0.10 0.08 0.06 0.05 0.04 0.04 0.03 0.04 0.03 0.04 0.03 0.34 0.25 0.18 0.13 0.10 0.07 0.07 0.05 0.06 0.04 0.06 0.04 0.06 0.04 0.61 0.44 0.32 0.23 0.16 0.14 0.10 0.10 0.07 0.08 0.06 0.08 0.06 0.08 0.06 0.82 0.56 0.40 0.30 0.22 0.18 0.13 0.14 0.10 0.11 0.08 0.11 0.08 0.11 0.08 500 1.47 1.05 0.76 0.54 0.41 0.29 0.25 0.18 0.19 0.13 0.16 0.11 0.16 0.11 0.16 0.11 1000 1.99 1.42 1.03 0.73 0.56 0.40 0.35 0.25 0.26 0.19 0.23 0.16 0.21 0.15 0.22 0.16 2000 2.73 1.95 1.40 1.00 0.76 0.54 0.47 0.34 0.36 0.26 0.31 0.22 0.30 0.21 0.30 0.21 4000 3.68 2.63 1.86 1.33 1.03 0.73 0.64 0.45 0.49 0.35 0.42 0.30 0.40 0.28 0.41 0.29 8000 4.57 3.26 2.36 1.69 1.30 0.93 0.81 0.58 0.61 0.43 0.53 0.38 0.52 0.37 0.52 0.37 16000 5.22 3.73 2.66 1.90 1.48 1.06 0.93 0.67 0.68 0.49 0.61 0.44 0.58 0.41 0.60 0.43 32000 7.60 5.50 4.00 2.86 2.20 1.57 1.34 0.96 1.00 0.71 0.86 0.61 0.86 0.61 0.86 0.61 64000 13.6 9.79 6.1 4.36 3.25 2.32 1.93 1.38 1.38 0.98 1.20 0.86 1.22 0.87 1.16 0.83 LP = Low Power, LN = Low Noise and continuous operation versus data rate, PGA gain, and power mode. out on the falling edge of SCLK. SCLK remains low when not active. Serial Interface DIN (Serial Data Input) The MAX11254 interface is fully compatible with SPI, QSPI™, and MICROWIRE®-standard serial interfaces. The SPI interface provides access to on-chip registers that are 8 bits to 24 bits wide. The interface consists of the standard SPI signals CSB, SCLK, DIN and DOUT. An additional RDYB output signals data availability. CSB (Chip Select) CSB is an active-low chip-select input to communicate with the MAX11254. CSB transitioning from low to high is used to reset the SPI interface. When CSB is low, data is clocked into the device from DIN on the rising edge of SCLK. Data is clocked out of DOUT on the falling edge of SCLK. When CSB is high, SCLK and DIN are ignored and DOUT is high impedance, allowing DOUT to be shared with other devices. SCLK (Serial Clock) The SCLK is used to synchronize data communication between the host device and the MAX11254.Data is shifted in on the rising edge of SCLK and data is shifted Data present on DIN is clocked into internal registers on the rising edge of SCLK. DOUT (Serial Data Output) The DOUT pin is actively driven when CSB is low and high impedance when CSB is high. Data is shifted out on DOUT on the falling edge of SCLK. RDYB (Data Ready) RDYB indicates the ADC conversion status and the availability of the conversion result. When RDYB is low, a conversion result is available. When RDYB is high, a conversion is in progress and the data for the current conversion is not available. RDYB is driven high after a complete read of the data register. RDYB resets to high four master clock cycles prior to the next DATA register update. If data was read, then RDYB transitions from high to low at the output data rate. If the previous data was not read, then the RDYB transitions from low to high for four master clock cycles and then transitions from high to low. QSPI is a trademark of Motorola, Inc. MICROWIRE is a registered trademark of National Semiconductor Corporation. www.maximintegrated.com Maxim Integrated │  18 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface In continuous mode, RDYB remains high for the first four conversion results and on the 5th result, RDYB goes low. 8 SCLKs for register access byte and 24 SCLKs (data bits to be written). If only 15 SCLKs were issued out of the 32 expected, the register value will not be updated. At least 16 SCLKs are required to update the MSB byte. For example, when the user issues a write command for a 24-bit register write and terminates after 16 SCLKs, only the MSB byte, bits 23 to 16 of the register are updated. Bits 15 to 0 retain the old value of the register. For sequencer mode 2 and sequencer mode 3, the RDYB behavior for a multichannel conversion can be controlled by the SEQ:RDYBEN bit. The default value of SEQ:RDYBEN is ‘0’. When set to ‘0’, RDYB behaves the same for multichannel conversion and single channel operation. The RDYB toggles high to low after each channel is ready to update its corresponding data register. After the channel data is read, the RDYB will reset back to ‘1’. If the channel data is not read and the next channel is ready to update its data, the RDYB will toggle low to high four cycles before the data update (similar to a single channel operation), and then toggle high to low indicating the new channel’s conversion data is available. If ‘N’ channels are enabled, RDYB will toggle high to low ‘N’ times. If SEQ:RDYBEN is set to ‘1’, the RDYB event for each channel is suppressed. The RDYB toggles high to low when the last channel is ready to update its corresponding data register and a single high to low transition happens. SPI Incomplete Read Command Termination The SPI interface stays in read mode for as long as CSB stays low independent of the number of SCLKs issued. The CSB pin must be toggled high to remove the device from the bus and reset the internal SPI controller. Any activity on the DIN pin is ignored while in the register read mode. The read operation is terminated if the CSB pin is toggled high before the maximum number of SCLKs is issued. When reading from DATA registers, the behavior of RDYB will depend on how many bits are read. If at least 23 bits are read, the read operation is complete and RDYB resets to high. If the user reads less than 23 bits, internally the logic considers the read incomplete, and RDYB stays low. The user can initiate a new read within the same conversion cycle; however, the new 24-bit read must complete before the next DATA register update. The STAT:SRDY[5:0] bits get set to ‘1’ when their corresponding channel finishes converting, irrespective of the RDYBEN setting for sequencer modes 2 and 3. The conversion status is available by reading the STAT:MSTAT bit. This stays high as long as the modulator is converting. SPI Timing Characteristics See Figure 4 for timing of RDYB. The SPI timing diagrams illustrating command byte and register access operations are shown in Figure 5 to Figure 8. The MAX11254 timing allows for the input data to be changed by the user at both rising and falling edges of SCLK. The data read out by the device on SCLK falling edges can be sampled by the user on subsequent rising or falling edges. SPI Incomplete Write Command Termination In case of register writes, the register values get updated every 8th clock cycle with a byte of data starting from the MSB. A minimum of 16 SCLKs are needed to write the first byte of data in a multibyte register or for an 8-bit register. For example, a 24-bit register write requires CONVERT COMMANDS CSB/SCLK/DIN N × tCNV N × tCNV SCYCLE=’1', CONTSC=’0' RDYB DATA not retrieved tCNV SCYCLE=’1', CONTSC=’1' RDYB 5 tCNV SCYCLE=’0', CONTSC=’x' DATA RETRIEVED tCNV RDYB Figure 4. Timing of RDYB in All Conversion Configurations: Single-Cycle, Single-Cycle Continuous and Continuous. In sequencer mode 1 and in sequencer modes 2 and 3, with SEQ:RDYBEN=’0’ N = 1. In sequencer modes 2 and 3 with SEQ:RDYBEN=’1’ N = number of active channels. www.maximintegrated.com Maxim Integrated │  19 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface SPI COMMAND WRITE BYTE RDYB ‘X’ tCSW tCSS0 tCSH1 CSB tCH SCLK tCL 1 8 tDH tDS DIN ‘1’ ‘X’ tCSS1 tCP ‘0’ MODE MODE RATE 0 3 1 RATE 2 RATE 1 RATE 0 tDOD tDOE HIGH-Z DOUT HIGH-Z ‘X’ Figure 5. SPI Command Byte Timing Diagram SPI 8b REGISTER WRITE ‘X’ RDYB tCSW tCSS0 tCSH1 CSB tCH SCLK tCL tCP 1 ‘X’ ‘1’ 16 8 tDS DIN tDH ‘1’ RS4 RS3 RS2 RS1 RS0 ‘0’ D7 HIGH-Z D6 D5 D4 D3 D2 D1 D0 ‘X’ tDOD tDOE DOUT tCSS1 ‘X’ HIGH-Z Figure 6. SPI Register Write Timing Diagram www.maximintegrated.com Maxim Integrated │  20 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface SPI 8b REGISTER READ ‘X’ RDYB tCSW tCSS0 tCSH1 CSB tCH SCLK tCL tCP 1 ‘1’ ‘X’ 16 8 tDS DIN tCSS1 ‘1’ RS4 RS3 RS2 RS1 RS0 ‘1’ ‘X’ ‘X’ ‘X’ ‘X’ ‘X’ tDOT tDOE DOUT 18b data tDH HIGH-Z ‘X’ D7 ‘X’ ‘X’ ‘X’ ‘X’ tDOH D6 D5 D4 D3 tDOD D2 D1 D0 HIGH-Z Figure 7. SPI Register Read Timing Diagram. For read patterns, the user may latch the MAX11254 output data on either rising edges (9–16) running at minimum latency or falling edges 9–16 running at increased latency. SPI 24B DATA READ RDYB tCSW tR1 tCSS0 CSB tCSH1 tCH SCLK tCL 8 tDS DIN ‘X’ ‘1’ ‘1’ 9 31 24b data tDH ‘0’ ‘0’ ‘1’ ‘1’ ‘0’ ‘1’ tDOE DOUT tCSS1 tCP 1 HIGH-Z tDOT ‘X’ MSB tDOH tDOD LSB HIGH-Z Figure 8. SPI DATA Readout Timing Diagram www.maximintegrated.com Maxim Integrated │  21 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Modes and Registers The MAX11254 interface operates in two fundamental modes, either to issue a conversion command or to access registers. The mode of operation is selected by a command byte. Every SPI transaction to the MAX11254 starts with a command byte. The command byte begins with the MSB (B7) set to ‘1’. The next bit (B6) determines whether a conversion command is sent or register read/ write access is requested. During a register read/write access, hold CSB low for the entire read or write operation and pull CSB high at the end of the command. For example, if the command is to read a 24-bit data register, hold CSB low for 32 SCLK cycles (8 cycles for the command byte plus 24 cycles for the data). CSB transitions must not occur near the rising edge of SCLK and must conform to the setup and hold timing detailed in the timing section. See SPI Timing Requirements table. Command Byte The conversion command sets the mode of operation (conversion, calibration, or power-down) as well as the conversion speed of the MAX11254. The register read/ write command specifies the register address as well as the direction of the access (read or write). Channel Sequencing Changing SEQUENCER Modes Mode Exit (See Table 8. Register Map for Register Definitions) To exit any of the three sequencer modes at any time program the following sequence: 1) Issue a power-down command to exit the conversion process to STANDBY or SLEEP, as defined in CTRL1:PD[1:0]: a. Write a conversion command byte (see Table 4. Command Byte Definition) and set MODE[1:0] of the command byte to ‘01’ 2) Wait for STAT:PDSTAT[1:0] = ‘01’ (SLEEP) or STAT:PDSTAT[1:0] = ‘10’ (STANDBY). Note: For all sequencer modes, the default exit state upon completion of all conversions is SLEEP. In sequencer mode 1, however, continuous conversion operation (CTRL1:SCYCLE=’0’) and continuous single-cycle conversion operation (CTRL1:SCYCLE=’1’ and CTRL1:CONTSC=’1’) are running continuously and must be terminated with the Mode Exit sequence. Table 4. Command Byte Definition B7 (MSB) B6 B5 B4 B3 B2 B1 B0 Conversion Command 1 0 MODE1 MODE0 RATE3 RATE2 RATE1 RATE0 Register Read/Write 1 1 RS4 RS3 RS2 RS1 RS0 R/W Table 5. Command Byte Decoding BIT NAME DESCRIPTION The MODE bits are used to set the functional operation of the MAX11254 according to the following decoding. MODE[1:0] RATE[3:0] RS[4:0] R/W MODE1 MODE0 DESCRIPTION 0 0 Unused 0 1 Power-down performed based on the CTRL1:PD[1:0] setting 1 0 Calibration performed based on the CTRL1:CAL[1:0] setting 1 1 Sequencer mode. The operation is based on the configuration of the SEQ register These bits determine the conversion speed of the MAX11254. The decoding is shown in Table 1. Register address as shown in Table 8. The R/W bit enables either a read or a write access to the address specified in RS[4:0]. If R/W is set to ‘0’, then data is written to the register. If the R/W bit is set to ‘1’, then data is read from the register. www.maximintegrated.com Maxim Integrated │  22 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Mode Change g. Set register GPO_DIR and, if desired, GPIO_CTRL to enable or disable the desired GPO and GPIO pins To change sequencer modes or to update the SEQ register, program the following sequence: 1) Perform Sequencer Mode Exit (see the Mode Exit section). 2) Set up the following registers: SEQ, CTRL1. a. Set SEQ:MODE[1:0] to select the new sequencer mode b. Set CTRL1:PD[1:0] to STANDBY or SLEEP state to set the desired exit state if a conversion command with MODE[1:0] set to ‘01’ is issued during the conversion. 3) Write the command byte (see Table 4). a. Set MODE[1:0] of the command byte to ‘11’ (sequencer mode) 4) Wait for STAT:PDSTAT[1:0] = ‘00’ to confirm conversion mode. SEQUENCER MODE 1—Single-Channel Conversion with GPO Control and MUX Delays This mode is used for single-channel conversions where the sequencer is disabled. Figure 9 illustrates the timing. To support high-impedance source networks, the conversion delay (SEQ:MDREN) feature must be enabled. The states of the GPO and GPIO pins are configured using the GPO_DIR and GPIO_CTRL registers and can be modified anytime during mode 1 operation. The values of the CHMAP0/CHMAP1 registers and DELAY:GPO[7:0] bits are ignored in this mode. Programming Sequence Mode Entry 1) Set up the following registers: SEQ, DELAY, CTRL1, GPO_DIR, GPIO_CTRL. a. SEQ:MODE[1:0] = ‘00’ for sequencer mode 1 b. SEQ:MUX[2:0] to select the channel for conversion c. Enable SEQ:MDREN to delay conversion start to allow for input settling. Set DELAY:MUX[7:0] to the desired conversion delay d. Set CTRL1:SCYCLE for either single cycle (no latency) or continuous conversion e. If single-cycle conversion is selected, set CTRL1:CONTSC to ‘1’ if continuous single-cycle conversion is desired f. Set CTRL1:PD[1:0] to STANDBY or SLEEP state to set the desired exit state if a conversion command with MODE[1:0] set to ‘01’ is issued during the conversion www.maximintegrated.com 2) Write a conversion command (see Table 4, Command Byte Definition). a. Set data rate using bits RATE[3:0] of the command byte b. Set MODE[1:0] of the command byte to ‘11’ for sequencer mode 3) Monitor RDYB for availability of conversion results in the DATA register (See Figure 4 for RDYB timing). Mode Exit 1) In single-cycle conversion mode (CTRL1:SCYCLE =’1’) the sequencer exits into SLEEP state. 2) In continuous conversion mode (CTRL1: SCYCLE=’0’ or (CTRL:SCYCLE=’1’ and CTRL1:CONTSC =’1’)), conversions continue nonstop until the mode is exited. To interrupt and exit continuous conversion or continuous single-cycle conversion follow the Changing SEQUENCER Modes—Mode Exit section to put the part into STANDBY or SLEEP state based on CTRL1:PD[1:0] set in step 1(f) of Mode Entry section. Changing Input Channel During Continuous Single-Cycle Conversion in Mode 1 1) Issue a conversion command with MODE[1:0] set to ‘01’ to exit the conversion process to STANDBY or SLEEP state (see the Changing SEQUENCER Modes—Mode Exit section). 2) Monitor STAT:PDSTAT = ‘10’ or ‘01’ to confirm exit to STANDBY or SLEEP state. 3) Set SEQ:MUX[2:0] to select the new channel for conversion 4) Write a conversion command (see Table 4) and set MODE[1:0] of command byte to ‘11’ SEQUENCER MODE 2 – Multichannel Scan with GPO Control and MUX Delays This mode is used to sequentially convert a programmed set of channels in a preset order. Figure 10 illustrates the timing. The states of the GPO and GPIO pins are configured using the GPO_DIR and GPIO_CTRL registers and can be modified anytime during mode 2 operation. In mode 2, register bits CHMAP0:CHn_ORD[2:0], CHMAP1:CHn_ ORD[2:0], CHMAP0:CHn_EN, and CHMAP1:CHn_EN are used to select channels and conversion order. Bits DELAY:GPO[7:0], CHMAP0:CHn_GPO[2:0], CHMAP0:CHn_GPOEN, CHMAP1:CHn_GPO[2:0], and CHMAP1:CHn_GPOEN are ignored in this mode. The bit CTRL1:CONTSC is ignored and bit CTRL1:SCYCLE = ‘0’ is invalid in this mode. Maxim Integrated │  23 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface SEQUENCER MODE 1 CHANNEL CONVERSION DEL SEQ:MDREN • DELAY:MUX SEQ:MUX[2:0] Figure 9. Sequencer Mode 1 Timing Diagram SEQUENCER MODE 2 CHANNEL CONVERSION DEL SEQ:MDREN • DELAY:MUX CHANNEL CONVERSION DEL SEQ:MDREN • DELAY:MUX CHANMAP:ORD[2:0] = 001 CHANNEL CONVERSION DEL SEQ:MDREN • DELAY:MUX CHANMAP:ORD[2:0] = 010 CHANNEL CONVERSION DEL SEQ:MDREN • DELAY:MUX CHANMAP:ORD[2:0] = 011 CHANNEL CONVERSION DEL SEQ:MDREN • DELAY:MUX CHANMAP:ORD[2:0] = 100 CHANNEL CONVERSION DEL SEQ:MDREN • DELAY:MUX CHANMAP:ORD[2:0] = 101 CHANMAP:ORD[2:0] = 110 Figure 10. Sequencer Mode 2 Timing Diagram Programming Sequence Mode Entry 1) Set up the following registers: SEQ, CHMAP0, CHMAP1, DELAY, GPO_DIR, GPIO_CTRL, CTRL1 a. SEQ:MODE[1:0] = ‘01’ for sequencer mode 2 b. If desired set SEQ:RDYBEN to ‘1’ to signal data ready only when all channel conversions are completed c. Enable SEQ:MDREN to delay conversion start to allow for input settling. Set DELAY:MUX[7:0] to the desired conversion delay d. Set CHMAP0 and CHMAP1 to select the channels and channel order for conversion e. Set CTRL1:PD[1:0] to STANDBY or SLEEP state to set the desired exit state if a conversion command with MODE[1:0] set to ‘01’ is issued during the conversion f. Set register GPO_DIR and GPIO_CTRL to enable or disable the desired GPO and GPIO pins g. Set CTRL1:SCYCLE = ‘1’ for single-cycle conversion mode 2) Write a conversion command (see Table 4). a. Set data rate using bits RATE[3:0] of the command byte www.maximintegrated.com b. Set MODE[1:0] of the command byte to ‘11’ 3) Monitor RDYB (if SEQ:RDYBEN=’0’) and bits STAT:SRDY[5:0] for availability of per channel conversion results in DATA[x] registers. Mode Exit 1) This mode exits to SLEEP state upon completion of sequencing all channels 2) To interrupt current sequencing perform mode exit, see the Changing SEQUENCER Modes—Mode Exit section. This device is put in STANDBY or SLEEP state based on CTRL1:PD[1:0] set in step 1(e) of Mode Entry section. SEQUENCER MODE 3 – Scan, With Sequenced GPO Controls This mode is used to sequentially convert a programmed set of channels in a preset order and sequence the GPO/GPIO pins concurrently. The GPO/GPIO pins are used to bias external circuitry such as bridge sensors; the common reference (GPOGND) is typically ground. After all channel conversions have completed, the MAX11254 automatically powers down into SLEEP mode. Figure 11 illustrates the Sequencer Mode 3 timing diagram for a three-channel scan. As long as CTRL3:GPO_ MODE is set to ‘1’, registers GPO_DIR and GPIO_CTRL are ignored in this mode, as the GPO/GPIO pins are controlled by the sequencer. Maxim Integrated │  24 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface If CTRL3:GPO_MODE is set to ‘0’, the GPO/GPIO pins are directly controlled by the GPO_DIR and GPIO_CTRL registers and are not controlled by the sequencer. g. Set CTRL1:PD[1:0] to STANDBY or SLEEP state to set the desired exit state if a conversion command with MODE[1:0] set to ‘01’ is issued during the conversion Programming Sequence h. Set CTRL1:SCYCLE = ‘1’ for single conversion mode Mode Entry 2) Write the conversion command (see Table 4) 1) Set up the following registers: SEQ, CHMAP0, CHMAP1, DELAY, CTRL1, CTRL3 a. Set the data rate using bits RATE[3:0] of the command byte a. SEQ:MODE[1:0]=’10’ for sequencer mode 3 b. Set MODE[1:0] of command byte to ‘11’ b. If desired, set SEQ:RDYBEN to ‘1’ to signal data ready only when all channel conversions are completed 3) Monitor RDYB (if SEQ:RDYBEN = ‘0’) and bits STAT:SRDY[5:0] for availability of per channel conversion results in DATA[x] registers. c. Enable SEQ:MDREN if conversion start is to be delayed to allow for input settling. Set DELAY:MUX[7:0] to the desired conversion delay Mode Exit 1) This mode exits to SLEEP state upon completion of sequencing all channels and GPO/GPIO pins. d. Set CTRL3:GPO_MODE to ‘1’ to enable GPO/ GPIO sequencing 2) To interrupt the current sequencing, perform mode exit. See the Changing SEQUENCER Modes—Mode Exit section. This puts the part in STANDBY or SLEEP state based on CTRL1:PD[1:0] set in step 1(g) of Mode Entry. e. Set CHMAP0 and CHMAP1 to enable the channels for conversion and to set the channel conversion order. Map the corresponding GPO/GPIO pins to a channel. f. Enable SEQ:GPODREN to add a delay before the multiplexer selects this channel for conversion. Set DELAY:GPO to a delay value sufficient for the bias to settle. The bit CTRL1:CONTSC is ignored and CTRL1:SCYCLE = ‘0’ is invalid in this mode. bit SEQUENCER MODE 3 TIMING MUX SELECTS CHANNEL CONVERSION STARTS GPO/GPIO ACTIVATED SCAN CHANNEL #1 DEL1 DEL2 DEL1 – PROGRAMMED DELAY USING BITS DELAY:GPO[7:0] TO PROVIDE SUFFICIENT SETTLING TIME FOR THE SENSOR BEFORE THE FIRST CHANNEL IS CONVERTED. CONVERSION ENDS TCONVERT DEL2 – PROGRAMMED DELAY USING BITS DELAY:MUX[7:0] FOR SENSOR AND ANALOG INPUT SETTLING AFTER THE MULTIPLIER SELECTS THE CHANNEL FOR CONVERSION. SEQ:MDREN • DELAY:MUX DELAY:GPO CHANMAP:ORD[2:0] = 001 GPO/GPIO ACTIVATED SCAN CHANNEL #2 (TCONVERT AND DEL1) END TRIGGER MUX SELECTS CHANNEL CONVERSION STARTS DEL2 CONVERSION ENDS TCONVERT CHANMAP:ORD[2:0] = 010 GPO/GPIO ACTIVATED SCAN CHANNEL #3 (TCONVERT AND DEL1) END TRIGGER MUX SELECTS CHANNEL CONVERSION STARTS DEL2 CONVERSION ENDS TCONVERT CHANMAP:ORD[2:0] = 011 Figure 11. Sequencer Mode 3 Timing Diagram for a Three-Channel Scan www.maximintegrated.com Maxim Integrated │  25 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Operating Examples—From Full Power-Down to Mode 3 In this example, channels 0, 1, and 2 are configured for conversion in mode 3. Channel 0 is configured last in the scan order and the GPIO0 is mapped to this channel. Channel 1 is configured first in the scan order and GPO1 is mapped to this channel. Channel 2 is configured second in the scan order and GPO0 is mapped to this channel. Channels 0, 1, and 2 are enabled for scan and GPO/ GPIO switching is also enabled. The RDYBEN is not set which generates a RDYB transition after each channel is converted. The PGA is configured for a gain of 128 and the data rate is 6,400sps in single-cycle mode. The MUX delays are enabled for all used channels and the GPO/ GPIO delays are disabled. Reference SPI Command Sequence section. Error Checking Sequencer Mode 3 The MAX11254 perform checks on registers CHMAP0 and CHMAP1. Error flags are set when invalid values are set: DVDD OPERATING BETWEEN 2.0V TO 3.6V LDO ENABLED (SET CTRL2:LDOEN = ‘1’) AND BYPASS CAPREG TO DGND WITH 220nF AVDD DVDD LDO ANALOG STAT:GPOERR is set when more than one input channel is mapped to the same GPO/GPIO pin. STAT:ORDERR is set when CHn_ORD is set as ‘000’ or ‘111’ and channel n is enabled using CHMAPx:CHn_EN. Supplies and Power-On Sequence The MAX11254 requires two power supplies, AVDD and DVDD. These power supplies can be sequenced in any order. The analog supply (AVDD) powers the analog inputs and the modulator. The DVDD supply powers the SPI interface. The low-voltage core logic can either be powered by the integrated LDO (default) or via DVDD. Figure 12 shows the two possible schemes. CAPREG denotes the internally generated supply voltage. If the LDO is used, the DVDD operating voltage range is from 2.0V to 3.6V. If the core logic is directly powered by DVDD (DVDD and CAPREG connected togeter), the DVDD operating voltage range is from 1.7V to 2.0V. DVDD OPERATING BETWEEN 1.7V TO 2.0V LDO DISABLED (SET CTRL2:LDOEN = ‘0’) AND CONNECT CAPREG TO DVDD AT BOARD LEVEL AVDD LDO MAX11254 DIGITAL INTERFACE INPUTS AND OUTPUTS 2V DIGITAL LOGIC CAPREG 220nF 0603 X7R DVDD ANALOG MAX11254 2V DIGITAL LOGIC DIGITAL INTERFACE INPUTS AND OUTPUTS CAPREG DGND Figure 12. MAX11254 Digital Power Architecture www.maximintegrated.com Maxim Integrated │  26 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface SPI Command Sequence SPI Transactions Description CSB=0; SPI=0xD012; CSB=1; Write to SEQ register Set MUX to 0b000, MODE to 0b10, GPODREN to 0b0, MDREN to 0b1, RDYBEN to 0b0 CSB=0; SPI=0xCAF000; CSB=1; Write to DELAY register Set MUX[7:0] to 0xF0, GPO[7:0] to 0x00 CSB=0; SPI=0xC65C; CSB=1; Write to CTRL3 register Set GPO_MODE to 0b1, all others to the default value; CSB=0; SPI=0xCE0B274F; CSB=1 Write to CHMAP0 register CH2=0x0B: CH2_GPO=0b00, CH2_ORD=0b010, CH2_EN=0b1, CH2_GPOEN=0b1 CH1=0x27: CH1_GPO=0b01, CH1_ORD=0b001, CH1_EN=0b1, CH1_GPOEN=0b1 CH0=0x4F: CH0_GPO=0b10, CH0_ORD=0b011, CH0_EN=0b1, CH0_GPOEN=0b1 CSB=0; SPI=0xC43F; CSB=1; Write to CTRL2 register set PGA gain to 0b111, LDOEN=0b1, LPMODE=0b1, PGAEN=0b1; CSB=0; SPI=0xBE; CSB=1; Convert using sequencer mode, data rate selected is 6,400 sps; RDYB negative edge transition from ‘1’ to ‘0’ indicates conversion completed and DATA register ready for read Wait CSB=0; SPI=0xD3000000; CSB=1; Wait Read register RDYB negative ‘0’ indicates DATA register DATA1; edge transition from ‘1’ to conversion completed and ready for read CSB=0; SPI=0xD5000000; CSB=1; Wait Read register RDYB negative ‘0’ indicates DATA register DATA2 edge transition from ‘1’ to conversion completed and ready for read CSB=0; SPI=0xD1000000; CSB=1; STOP Read register DATA0; Mode activity is completed. The MAX11254 powers down into SLEEP state waiting for the next command www.maximintegrated.com Maxim Integrated │  27 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Reset Power-On Reset and Undervoltage Lockout A global power-on reset (POR) is triggered until AVDD, DVDD, and CAPREG cross a minimum threshold voltage (VLH), as shown in Figure 13. Hardware Reset Using RSTB The MAX11254 features an active-low RSTB pin to perform a hardware reset. Pulling the RSTB pin low stops any conversion in progress, reconfigures the internal registers to the power-on reset state and resets all digital filter states to zero. After the reset cycle is completed, the MAX11254 remains in STANDBY state and awaits further commands. To prevent ambiguous power-supply conditions from causing erratic behavior, voltage detectors monitor AVDD, DVDD, and CAPREG and hold the MAX11254 in reset when supplies fall below VHL (see Figure 13). The analog undervoltage lockout (AVDD UVLO) prevents the ADC from converting when AVDD falls below VHL. The CAPREG UVLO resets and prevents the low-voltage digital logic from operating at voltages below VHL. DVDD UVLO thresholds supersede CAPREG thresholds when CAPREG is externally driven. Figure 14 shows a flow diagram of the POR sequence. Glitches on supplies AVDD, DVDD, and CAPREG for durations shorter than TP are suppressed without triggering POR or UVLO. For glitch durations longer than TP, POR is triggered within TDEL seconds. See the Electrical Characteristics table for values of VLH, VHL, TP, and TDEL. Software Reset The host can issue a software reset to restore the default state of the MAX11254. A software reset sets the interface registers back into their default states and resets the internal state machines. However, a software reset does not emulate the complete POR or hardware reset sequence. Two SPI transactions are required to issue a software reset: First set CTRL1:PD[1:0] to ‘11’ (RESET). Then issue a conversion command with MODE[1:0] set to ‘01’. To confirm the completion of the reset operation, STAT:PDSTAT and STAT:INRESET must be monitored. Power-On Reset Timing Power-on reset is triggered during power-up and undervoltage conditions as described above. Completion of the POR process is monitored by polling STAT:PDSTAT[1:0] = ‘10’ for STANDBY state (see Figure 15). AVDD DVDD CAPREG VLH VHL Figure 16 shows the state transition for the RESET command and the relative timing of STAT register update. During reset, INRESET = ’1’ and PDSTAT= ‘11’. The SPI interface cannot be written until MAX11254 enters STANDBY state where PDSTAT = ‘10’. To confirm completion of the RESET command, monitor for INRESET = ‘0’ and PDSTAT = ‘10’.0 Table 6 summarizes the maximum delay for reset operation. VHYS TP TDEL TP TDEL PORB Figure 13. Undervoltage Lockout Characteristic Voltage Levels and Timing www.maximintegrated.com Maxim Integrated │  28 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Table 6. Maximum Delay Time for Mode Transitions COMMAND ISSUED* MAX11254 STATE BEFORE COMMAND COMMAND INTERPRETATION MAXIMUM DELAY TIME TO NEXT STATE† MAX11254 STATE AFTER COMMAND RESET Command ignored 0 RESET SLEEP Command ignored 0 SLEEP STANDBY MAX11254 powers down into SLEEP mode 20ms SLEEP STANDBY (fast) Issue a conversion command and then monitor STAT:PDSTAT[1:0] for change of mode; then send conversion command with MODE[1:0] set to ‘01’ 15µs SLEEP Calibration Calibration stops, MAX11254 powers down into SLEEP mode 3µs SLEEP Conversion Conversion stops, MAX11254 powers down into SLEEP mode 3µs SLEEP SLEEP Mode change from SLEEP to conversion SAT: PDSTAT changes to ‘00’ TPUPSLP + 3µs Conversion STANDBY STANDBY to conversion TPUPSBY + 3µs Conversion RESET Command ignored 0 RESET SLEEP MAX11254 changes to STANDBY 20ms STANDBY SLEEP (fast) Issue a conversion command and then monitor STAT:PDSTAT[1:0] for change of mode; then send conversion command with MODE[1:0] set to ‘01’ 85µs STANDBY STANDBY Command ignored 0 STANDBY Calibration Calibration stops 3µs STANDBY Conversion Conversion stops 3µs STANDBY RESET Command ignored 0 RESET SLEEP Command ignored 0 SLEEP STANDBY Register values reset to default 28ms STANDBY Calibration Calibration stops, register values reset to default 6µs STANDBY Conversion Conversion stops, register values reset to default 6µs STANDBY POR OFF From complete power-down to STANDBY mode 10ms STANDBY RSTB Any From any state to STANDBY mode 10ms STANDBY SLEEP CONVERT STANDBY RESET *The commands are defined as follows: SLEEP: Set CTRL1:PD[1:0] to ‘01’; issue a conversion command with MODE[1:0] set to ‘01’ STANDBY: Set CTRL1:PD[1:0] to ‘10’; issue a conversion command with MODE[1:0] set to ‘01’ RESET: Set CTRL1:PD[1:0] to ‘11’; issue a conversion command with MODE[1:0] set to ‘01’ CONVERT: Any conversion command with MODE[1:0] set to ‘11’ POR: Power-on reset during initial power-up or UVLO RSTB: Hardware reset with RSTB pin †See the Electrical Characteristics for TPUPSLP and TPUPSBY www.maximintegrated.com Maxim Integrated │  29 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface POWER-ON NO NO AVDD UVLO TRIGGERED? CAPREG UVLO TRIGGERED? YES YES POWER-ON RESET FOR 2V DIGITAL LOGIC ANALOG RESET NO DVDD UVLO TRIGGERED? YES POWER-ON RESET FOR DIGITAL LOGIC AND INTERFACE OSCILLATOR RESET Figure 14. MAX11254 UVLO and POR Flow Diagram IN POWER-ON RESET SERIAL INTERFACE READ ONLY OUT OF POWER-ON RESET SERIAL INTERFACE AVAILABLE FOR BOTH READ AND WRITE VDVDD STAT:PDSTAT=’XX’ ‘11’ ‘10’ (STANDBY) Figure 15. Power-On Reset and PDSTAT Timing www.maximintegrated.com Maxim Integrated │  30 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Power-Down States STANDBY STATE TO SLEEP STATE (FAST) To reduce overall power consumption, the MAX11254 features two power-down states: STANDBY and SLEEP. In SLEEP mode all circuitry is powered down, and the supply currents are reduced to leakage currents. In STANDBY mode the internal LDO and a low-frequency oscillator are powered up to enable fast start-up. After POR or a hardware reset the MAX11254 is in STANDBY mode until a command is issued. 1) Set CTRL1:PD[1:0] = ‘01’ for STANDBY state. Changing Power-Down States 6) Monitor STAT:PDSTAT = ‘01’ for completion. Mode transition times are dependent on the current mode of operation. STAT:PDSTAT is updated at the end of all mode changes and is a confirmation of a completed transaction. The MAX11254 does not use a command FIFO or queue. The user must confirm the completed transaction by polling STAT:PDSTAT after the expected delay, as described in Table 6. Once the transition is complete, it is safe to send the next command. Calibration Verify that STAT:PDSTAT indicates the desired state before issuing a conversion command. Writes to any CTRL register during a conversion aborts the conversion and returns the MAX11254 to STANDBY state. SLEEP STATE TO STANDBY STATE (FAST) 1) Set CTRL1:PD[1:0] = ‘10’ for STANDBY state. 2) Set SEQ:MODE[1:0] = ‘00’ for sequencer mode 1 3) Issue a conversion command with MODE[1:0] set to ‘11’. 4) Monitor STAT:PDSTAT[1:0] = ‘00’ for active state. 5) Write the conversion command with MODE[1:0] set to ‘01’. 6) Monitor STAT:PDSTAT = ‘10’ for completion. COMMAND LATCHED RESET COMMAND 2) Set SEQ:MODE[1:0] = ‘00’ for sequencer mode 1 3) Issue a conversion command with MODE[1:0] set to ‘11’. 4) Monitor STAT:PDSTAT[1:0] = ‘00’ for active state. 5) Write the conversion command with MODE[1:0] set to ‘01’. Two types of calibration are available: self calibration and system calibration. Self calibration is used to reduce the MAX11254’s gain and offset errors during changing operating conditions such as supply voltages, ambient temperature, and time. System calibration is used to reduce the gain and offset error of the entire signal path. This enables calibration of board level components and the integrated PGA. System calibration requires the MAX11254’s inputs to be reconfigured for zero scale and full scale during calibration. The GPO/GPIO pins can be used for this purpose. See Figure 17 for details of the calibration signal flow. The calibration coefficients are stored in the registers SCOC, SCGC, SOC and SGC. Data written to these registers is stored within the SPI domain and copied to internal registers before a conversion starts to process the raw data (see Figure 17). An internal or system calibration only updates the internal register values and does not alter the contents stored in the SPI domain. The bit CTRL3:CALREGSEL decides whether the internal contents or the contents stored in the SPI domain are read back during a read access of these registers. SERIAL INTERFACE IS READ ONLY DURING THIS PERIOD SERIAL INTERFACE IS AVAIABLE FOR BOTH READ AND WRITE IDLE STAT:INRESET STAT:PDSTAT = ‘00’/’10' ‘11’ ‘10’ Figure 16. STAT:INRESET and STAT:PDSTAT Timing www.maximintegrated.com Maxim Integrated │  31 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface RAW RESULT SPI BLOCK CAL BLOCK NOSCO=0 F T SCOC SUBTRACT SCOC_INTERNAL 24 NOSCG=0 F T SCGC MULTIPLY SCGC_INTERNAL 24 NOSYSO=0 F T SOC SUBTRACT SOC_INTERNAL 24 NOSYSG=0 F T SGC MULTIPLY SGC_INTERNAL 24 DATA FINAL RESULT F UNIPOLAR T STATUS REG x2 LIMITER Figure 17. Calibration Flow Diagram www.maximintegrated.com Maxim Integrated │  32 MAX11254 Bits NOSCO, NOSCG, NOSYSO, NOSYSG enable or disable the use of the individual calibration coefficients during data processing. See Figure 17, Calibration Flow Diagram. Self-Calibration The self-calibration is an internal operation and does not disturb the analog inputs. The self-calibration command can only be issued in sequencer mode 1 (SEQ:MODE[1:0] = ‘00’). Self-calibration is accomplished in two independent phases, offset and gain. The first phase disconnects the inputs to the modulator and shorts them together internally to develop a zero-scale signal. A conversion is then completed and the results are post-processed to generate an offset coefficient which cancels all internally generated offsets. The second phase connects the inputs to the reference to develop a full-scale signal. A conversion is then completed and the results are post-processed to generate a full-scale coefficient, which scales the converters full-scale analog range to the full-scale digital range. The entire self-calibration sequence requires two independent conversions, one for offset and one for full scale. The conversion rate is 50sps in the single-cycle mode. This rate provides the lowest noise and most accurate calibrations. The self-calibration operation excludes the PGA. A system level calibration is available in order to calibrate the PGA signal path. A self-calibration is started as follows: Set CTRL1:CAL[1:0] to ‘00’ (self-calibration). Then issue a conversion command with the MODE[1:0] bits set to ‘10’ (calibration). A self-calibration requires 200ms to complete. System Calibration This mode is used when calibration of board level components and the integrated PGA is required. The system calibration command is only available in sequencer mode 1. A system calibration requires the input to be configured to the proper level for calibration. The offset and full-scale system calibrations are, therefore, performed using separate commands. The channel selected in the SEQ:MUX bits is used for system calibrations. To perform a system offset calibration, the inputs must be configured for zero scale. The inputs do not necessarily need to be shorted to 0V as any voltage within the range of the calibration registers can be nulled in this calibration. A system offset calibration is started as follows: Set CTRL1:CAL[1:0] to ‘01’ (system offset calibration). Then issue a conversion command with the MODE[1:0] bits set www.maximintegrated.com 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface to ‘10’ (calibration). The system offset calibration requires 100ms to complete. To perform a system full-scale calibration, the inputs must be configured for full scale. The input full-scale value does not necessarily need to be equal to VREF since the input voltage range of the calibration registers can scale up or down appropriately within the range of the calibration registers. A system full-scale calibration is started as follows: Set CTRL1:CAL[1:0] to ‘10’ (system full-scale calibration). Then issue a conversion command with the MODE[1:0] bits set to ‘10’ (calibration). The system full-scale calibration requires 100ms to complete. The GPO/GPIO pins can be used during a system calibration. All four calibration registers (SOC, SGC, SCOC, and SCGC) can be written by the host to store special calibration values. The new values will be copied to the internal registers at the beginning of a new conversion. GPIOs The MAX11254 provides two general-purpose input/output ports that are programmable through the GPIO_CTRL register. Enable the GPIO pins by setting bits GPIO1_EN and GPIO0_EN, respectively. Set the DIR bits to select the pins to be configured as inputs or outputs. All pins are inputs by default. When programmed as output, set the DIO bits to set the pin state to ‘0’ or ‘1’. Conversion Synchronization Using SYNC Pin and External Clock The SYNC pin—in conjunction with an external clock— can be used to synchronize the data conversions to external events. Set GPIO_CTRL:GPIO1_EN to ‘0’ and GPI_CTRL:GPIO0_EN to ‘0’ to configure the GPIO1/ SYNC and GPIO0/CLK pins. Configure sync mode by setting CTRL3:SYNC_MODE to ‘1’ and external clock mode by setting CTRL2:EXTCLK to ‘1’. The synchronization mode is used to detect if the current conversions are synchronized to a continuous pulse signal with a period greater than the data rate. Ideally, the frequency of the synchronization signal is an integer multiple of the conversion rate. The synchronization mode records the number of device master clock cycles between a RDYB assertion and the rising edge of the next SYNC pulse. At the following SYNC pulse, the number of master clock cycles between a RDYB assertion and the rising edge of the SYNC pulse is evaluated again and compared to the recorded value. If the new number of master clock cycles differs by more than one from the recorded Maxim Integrated │  33 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Components of the ADC value, the conversion in progress is stopped, the digital filter contents are reset, and a new conversion starts. As the digital filter is reset, the full digital filter latency is required before valid results are available. If the new master clock count is within the ±1 count limit, the conversions continue uninterrupted. Modulator MODULATOR DIGITAL OVERRANGE The output of the SINC filter is monitored for overflow. When SINC filter overflow is detected, the STAT:DOR bit is set to ‘1’ and a default value is loaded into the DATA register depending on the polarity of the overload. A positive overrange causes 0x7FFFFF to be written to the DATA register. A negative overrange causes 0x800000 to be written to the DATA register. See Table 7. Figure 18 shows the timing relationship between the MAX11254 master clock and the SYNC signal. Due to startup delays, any SYNC pulses before the first RDYB assertion (low-going edge) are ignored. The first rising edge on the SYNC pin after a RDYB assertion establishes the relationship between the SYNC signal and the conversion timing. MODULATOR ANALOG OVERRANGE The modulator analog overrange is used to signal the user that the input analog voltage has exceeded preset limits defined by the modulator operating range. These limits Table 7. Analog Overrange Behavior for Different Operating Conditions and Modes STAT REGISTER AOR DOR DATA -VREF < VIN < VREF INPUT VOLTAGE 0 0 RESULT VREF < VIN < VOVRRNG 1 0 RESULT -VOVRRNG < VIN < -VREF 1 0 RESULT VIN > VOVRRNG 1 1 0x7FFFFF VIN < -VOVRRNG 1 1 0x800000 The DATA values shown are for bipolar ranges with two’s complement number format. VOVRRNG is the overrange voltage value typically > 120% of VREF. FIRST VALID SYNC > 2 x tCLK IGNORED > 2 x tCLK SYNC SIGNAL RDYB CLK FIRST CONVERSION READY N’ N ... tCLK DEVICE INITIATES A RESET AND RESTARTS CONVERSIONS WHEN N AND N’ DIFFER BY MORE THAN ±1CLK COUNT. OTHERWISE CONVERSIONS CONTINUE UNINTERRUPTED. Figure 18. Timing Relationship between SYNC Signal, External Clock and RDYB www.maximintegrated.com Maxim Integrated │  34 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface SINC5 FILTER, NORMAL MODE REJECTION DATA RATE 64000.0sps -30 GAIN (dB) -50 -70 -90 -110 -130 -150 -170 -190 0 -10 -20 -30 -40 -50 -60 GAIN (dB) -10 SINC5 FILTER, NORMAL MODE REJECTION SINGLE CYCLE DATA RATE 4000.0sps -80 -100 -120 -70 -90 -110 -130 -140 -150 -160 -170 -180 -190 -200 0 2 4 8 10 6 FREQUENCY (Hz) 0 -20 -40 -60 -80 -100 -120 -140 -160 -180 -200 12 x 104 0 1 2 3 4 FREQUENCY (Hz) 5 6 x 104 Figure 19. Digital Filter Frequency Response for 64ksps Continuous Data Rate and 12.8ksps Single-Cycle Data Rate Figure 20. Digital Filter Frequency Response for 4ksps SingleCycle Data Rate are approximately 120% of the applied reference voltage. When analog overrange is detected the STAT:AOR bit is set to ‘1’ after DATA is updated. The AOR bit will always correspond to the current value in the DATA register. See Table 7. Split Supplies SINC Filter The digital filter is a mode-configurable digital filter and decimator that processes the data stream from the fourth order delta-sigma modulator and implements a fifth order SINC function with an averaging function to produce a 24-bit wide data stream. The SINC filter allows the MAX11254 to achieve very high SNR. The bandwidth of the fifth order SINC filter is approximately twenty percent of the data rate. See Figures 19 and 20 for the filter response of 64ksps and 4ksps, respectively. See Figure 21 for the bandwidth of the individual signal stages. Applications Information Connecting an External 1.8V Supply to DVDD for Digital I/O and Digital Core The voltage range of the DVDD I/O supply is specified from 2.0V to 3.6V if the internal LDO is used to power the digital core. If a lower I/O supply voltage is desired, the internal LDO can be disabled, and DVDD and CAPREG can be connected together as shown in Figure 22. In this mode of operation, DVDD can vary from 1.7V to 2.0V. The internal LDO must be disabled by setting CTRL2:LDOEN to ‘0’. www.maximintegrated.com The MAX11254 supports unipolar and split analog power supplies for input range flexibility. Using a split analog supply enables sampling below ground reference. The true bipolar input range is up to ±1.8V. See Figure 3 for analog input voltage range for both unipolar and split supplies. Sensor Fault Detection The MAX11254 includes a 1µA current source and a 1µA current sink. The source pulls current from AVDD to AIN_P and sink from AIN_N to AVSS. The currents are enabled by register bit CTRL3:CSSEN. These currents are used to detect damaged sensors in either open or shorted state. The current sources and sinks are functional over the normal input operating voltage range, as specified. These currents are used to test sensors for functional operation before taking measurements on that input channel. With the source and sink enabled, the currents flow into the external sensor circuit and measurement of the input voltage is used to diagnose sensor faults. A full-scale reading could indicate a sensor is open circuit or overloaded or that the ADC’s reference is absent. If a zero-scale is read back, this may indicate the sensor is short-circuited. Maxim Integrated │  35 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface G=128 Sn = 5nV/√Hz ANALOG FILTER PGA BW3 N DELTA-SIGMA ADC BW3 BW3 NEB1 = π /2 x BW3 BW3 10nF 23k 1nF 230k 100pF 2.3M NEB 36k 361k 3.6M 24 N FDATA NEB3 NEB2 = π /2 x BW3 BW3 NEB 10nF 21k 33k 1nF 69k 108k 100pF 73k 115k DIGITAL FILTER NEB3 = 0.215 x FDATA 64ksps = 13.2kHz Figure 21. Signal Path Block Diagram Including Bandwidth of Each Stage 2.7V TO 3.6V REF 10nF 1.7V TO 2.0V 1µF REFN AVDD REFP 1µF X7R DVDD AIN0P 1nF C0G RSTB CSB AIN0N MAX11254 SCLK DIN µC DOUT AIN5P RDYB 1nF C0G AIN5N GPO0 GPO1 GPOGND CAPP CAPN CAPREG AVSS DGND 1nF C0G Figure 22. Application Diagram for 1.8V DVDD www.maximintegrated.com Maxim Integrated │  36 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Register Map Legend: CNV IN PROGRESS column – behavior during conversion: CNV – Normal read/write activities are available. CS – Writes to these registers immediately abort conversion in progress and the MAX11254 enters STANDBY state. IG – No changes, write is ignored. RETENTION column – behavior during SLEEP mode: R – The value of the register is retained. M – Only bits in < > are retained. Others are cleared. The address column shows the register address as used in the command byte definition (see Table 4). www.maximintegrated.com Maxim Integrated │  37 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface NAME R/W CNV IN PROGRESS RETENTION ADDRESS (RS[4:0]) Table 8. Register Map BIT 7 STAT R — M 0 SCANERR BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 — INRESET REFDET ORDERR GPOERR ERROR SYSGOR DOR AOR RATE3 RATE2 RATE1 RATE0 MSTAT CTRL1 R/W CS R 1 CAL1 CAL0 PD1 PD0 U/B FORMAT SCYCLE CONTSC CTRL2 R/W CS R 2 EXTCLK CSSEN LDOEN LPMODE PGAEN PGAG2 PGAG1 PGAG0 CALREGSEL NOSYSG NOSYSO NOSCG NOSCO DIR1 DIR0 — DIO1 DIO0 CTRL3 R/W CS R 3 — GPIO_CTRL R/W CNV R 4 GPIO1_EN DELAY R/W IG R 5 CHMAP1 CHMAP0 R/W R/W IG IG R R 6 7 GPO_MODE SYNC_MODE GPIO0_EN — MUX[7:0] GPO[7:0] — CH5_GPO1 CH5_ GPO0 CH5_ORD2 CH5_ORD1 CH5_ORD0 CH5_EN CH5_GPOEN — CH4_GPO1 CH4_ GPO0 CH4_ORD2 CH4_ORD1 CH4_ORD0 CH4_EN CH4_GPOEN — CH3_GPO1 CH3_GPO0 CH3_ORD2 CH3_ORD1 CH3_ORD0 CH3_EN CH3_GPOEN — CH2_GPO1 CH2_GPO0 CH2_ORD2 CH2_ORD1 CH2_ORD0 CH2_EN CH2_GPOEN — CH1_GPO1 CH1_GPO0 CH1_ORD2 CH1_ORD1 CH1_ORD0 CH1_EN CH1_GPOEN — CH0_GPO1 CH0_GPO0 CH0_ORD2 CH0_ORD1 CH0_ORD0 CH0_EN CH0_GPOEN SEQ R/W CNV R 8 MUX2 MUX1 MUX0 MODE1 MODE0 GPODREN MDREN RDYBEN GPO_DIR R/W CNV R 9 — — — — — — GPO1 GPO0 SOC R/W IG R 10 D[23:0] SGC R/W IG R 11 D[23:0] SCOC R/W IG R 12 D[23:0] SCGC R/W IG R 13 D[23:0] DATA0 R — R 14 D[23:0] DATA1 R — R 15 D[23:0] DATA2 R — R 16 D[23:0] DATA3 R — R 17 D[23:0] DATA4 R — R 18 D[23:0] DATA5 R — R 19 D[23:0] www.maximintegrated.com Maxim Integrated │  38 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Register Definitions STAT: Status Register (Read) BIT NAME INRESET SRDY5 SRDY4 SRDY3 SRDY2 SRDY1 SRDY0 DEFAULT 0 0 0 0 0 0 0 0 BIT NAME SCANERR REFDET ORDERR GPOERR ERROR SYSGOR DOR AOR DEFAULT 0 1 0 0 0 0 0 0 BIT NAME RATE3 RATE2 RATE1 RATE0 PDSTAT1 PDSTAT0 MSTAT RDY DEFAULT 0 0 0 0 0 0 0 0 This register provides the functional status of the MAX11254. BIT NAME DESCRIPTION INRESET This bit is set to ‘1’ to indicate that the MAX11254 is in reset. SRDY[5:0] This bit is set to ‘1’ in sequencer modes 2 and 3 to indicate that a new conversion result is available from the channel indicated by the SRDY bit position. A complete read of the DATA register associated with the SRDY bit will reset the bit to ‘0’. At the start of a scan mode these bits are reset to ‘0’. SCANERR This bit is set to ‘1’ if sequencer mode 2 or 3 is selected and no channels or invalid channel numbers (‘000’ or ‘111’) are enabled in the CHMAP1 or CHMAP0 register. Until SCANERR is cleared, conversion commands are aborted. REFDET This bit is set to ‘1’ if a proper reference voltage is detected and ‘0’ if a proper reference voltage is missing. In SLEEP or STANDBY mode the value of this bit is ‘0’. The trigger level for this bit is VREF < 0.35V. This error does not inhibit normal operation and is intended for status only. The value of this status bit is valid within 30µs after a conversion start command and is invalid when not in conversion. ORDERR This bit is set to ‘1’ if two or more CHX_ORD bits decode to the same scan sequence order and are also enabled. This bit is also set to ‘1’ in the case when a channel is enabled for scan with CHX_EN=’1’ and CHX_ ORD[2:0] = ‘000’ or ‘111’. The CHX_ORD[2:0] values of ‘000’ and ‘111’ are not allowed as order of an enabled channel. The allowable orders are ‘001’, ‘010’, ‘011’, ‘100’, ‘101’, ‘110’. The MAX11254 remains in STANDBY state until this error is removed. The channel order must be strictly sequential and no missing numbers are allowed. For instance, if 4 channels are enabled then the order must be ‘001’, ‘010’, ‘011’, ‘100’. Any other order is flagged as ORDERR and the MAX11254 remains in STANDBY mode. GPOERR This bit is set to ‘1’ if more than one input channel is mapped to the same GPO/GPIO pin, and CHX_GPOEN is enabled for more than one channel. The MAX11254 remains in STANDBY state until this error is removed. ERROR This bit is set to ‘1’ to indicate invalid configuration states. This bit is set if CAL[1:0] is programmed to ‘11’ which is an invalid state. This bit is set if CTRL1:SCYCLE = ‘0’ for scan modes 2 and 3. This error puts the MAX11254 into STANDBY mode. www.maximintegrated.com Maxim Integrated │  39 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface STAT: Status Register (Read) (continued) BIT NAME DESCRIPTION SYSGOR This bit is set to ‘1’ to indicate that a system gain calibration results in an overrange condition of the calibration coefficient. The SCGC calibration coefficient is set to the maximum value of 1.9999999. DOR This bit is set to ‘1’ to indicate that the conversion result has exceeded the maximum or minimum value of the converter and that the result has been clipped or limited to the maximum or minimum value. When set to ‘0’ the conversion result is within the full-scale range of the inputs. AOR This bit is set to ‘1’ to indicate that the modulator detected an analog overrange condition by having the input signal level greater than the reference voltage. This check for overrange includes the PGA gain. RATE[3:0] These bits indicate the conversion rate that corresponds to the result in the DATA registers or the rate that was used for calibration coefficient calculation. The corresponding RATE[3:0] is only valid until the DATA registers are read. The decoding of RATE[3:0] is shown in Table 1. These bits indicate the state of the MAX11254. See Table 6 for transition times. PDSTAT1 PDSTAT0 0 0 0 1 SLEEP 1 0 STANDBY (default) 1 1 RESET PDSTAT[1:0] DESCRIPTION CONVERSION MSTAT This bit is set to ‘1’ to indicate when a signal measurement is in progress. This indicates that a conversion, self-calibration, or system calibration is in progress and that the modulator is busy. When the modulator is not converting, this bit will be set to ‘0’. RDY This bit is set to ‘1’ to indicate that a new conversion result is available in sequencer mode 1. A complete read of the corresponding DATA register will reset this bit to ‘0’. This bit is invalid in sequencer mode 2 or 3. The function of this bit is redundant and is duplicated by the RDYB pin. www.maximintegrated.com Maxim Integrated │  40 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface CTRL1: Control Register 1 (Read/Write) Default = 0x02l BIT NAME CAL1 CAL0 PD1 PD0 U/B FORMAT SCYCLE CONTSC DEFAULT 0 0 0 0 0 0 1 0 This register controls the selection of operational modes and configurations. BIT NAME DESCRIPTION The calibration bits control the type of calibration performed when a calibration command byte is issued: CAL[1:0] CAL1 CAL0 0 0 Performs a self-calibration DESCRIPTION 0 1 Performs a system-level offset calibration 1 0 Performs a system-level full-scale calibration 1 1 Reserved. Do not use. Selects the power-down state to be executed. The MAX11254 enters the selected power-down state after a conversion command with MODE[1:0] set to ‘01’ is written. The state is decoded as below: PD[1:0] U/B PD1 PD0 DESCRIPTION 0 0 NOP (default) 0 1 SLEEP 1 0 STANDBY 1 1 RESET The ‘unipolar/bipolar’ bit controls the input range. A ‘1’ selects unipolar input range and a ‘0’ selects bipolar input range. FORMAT The ‘format’ bit controls the digital format of the bipolar range data. A ‘0’ selects two’s complement and a ‘1’ selects offset binary format of the bipolar range. The data for unipolar range is always formatted in offset binary format. SCYCLE The ‘single-cycle’ bit selects either no-latency single conversion mode or continuous conversion in sequencer mode 1. A ‘1’ selects single-cycle mode where a no-latency conversion is followed by a power-down to SLEEP mode. A ‘0’ selects continuous conversion mode with a latency of 5 conversion cycles for filtering. The RDYB pin goes low when valid/settled data is available. Only SCYCLE = ‘1’ is valid in sequencer mode 2 and 3. CONTSC The ‘continuous single-cycle’ bit selects between single or continuous conversions while operating in single-cycle mode in sequencer mode 1. A ‘1’ selects continuous conversions and a ‘0’ selects a single conversion. www.maximintegrated.com Maxim Integrated │  41 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface CTRL2: Control Register 2 (Read/Write) Default = 0x20 BIT NAME EXTCLK CSSEN LDOEN LPMODE PGAEN PGAG2 PGAG1 PGAG0 DEFAULT 0 0 1 0 0 0 0 0 This register controls the selection and configuration of optional functions. BIT NAME DESCRIPTION EXTCLK External clock mode is enabled by setting this bit to ‘1’. In this mode, the internal oscillator is bypassed and the GPIO0/CLK pin is configured as external clock input. CSSEN Setting this bit to ‘1’ enables the current source and current sink on the analog inputs to detect sensor opens or shorts. LDOEN Set this bit to ‘1’ to enable the internal LDO. Set this bit to ‘0’ when driving the CAPREG pin externally with a 1.8V supply. When driving the CAPREG pin with external supply, the user must ensure that the CAPREG pin is connected to the DVDD pin. LPMODE PGAEN PGA low-power mode is enabled by setting this bit to ‘1’. The PGA operates with reduced power consumption and reduced performance. The LPMODE does not affect power or performance when the PGA is not enabled. The PGA enable bit controls the operation of the PGA. A ‘1’ enables and a ‘0’ disables the PGA. The ‘PGA’ bits control the PGA gain. The PGA gain is set by: PGA[2:0] www.maximintegrated.com PGA2 PGA1 PGA0 DESCRIPTION 0 0 0 Gain = 1 0 0 1 Gain = 2 0 1 0 Gain = 4 0 1 1 Gain = 8 1 0 0 Gain = 16 1 0 1 Gain = 32 1 1 0 Gain = 64 1 1 1 Gain = 128 Maxim Integrated │  42 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface CTRL3: Control Register 3 (Read/Write) Default = 0x1C BIT NAME GPO_MODE SYNC_MODE CALREGSEL NOSYSG NOSYSO NOSCG NOSCO DEFAULT 0 0 1 1 1 0 0 This register is used to control the operation and calibration of the MAX11254. BIT NAME DESCRIPTION GPO_MODE The value of this bit controls the GPO mode for sequencer mode 3. When set to ‘1’, the GPO and the GPIO pins are sequenced based on the channel mapping in the CHMAP1 and CHMAP0 registers. When set to ‘0’, the GPO and GPIO pins are directly controlled by the GPO_DIR and GPIO_CTRL registers, respectively, during conversion or STANDBY state. This bit has no effect in sequencer modes 1 and 2. SYNC_MODE This bit controls sync mode (see the Conversion Synchronization Using Sync Pin and External Clock section). When set to ‘1’, the synchronization mode is enabled, when set to ‘0’ it is disabled. CALREGSEL This bit controls which calibration value is read during a calibration register inquiry. Set this bit to ‘1’ to read back the interface value. Set this bit to ‘0’ to read back the internal register value. NOSYSG The ‘no system gain’ bit controls the use of the system gain calibration coefficient. Set this bit to ‘1’ to disable the use of the system gain value when computing the final offset and gain corrected data value. Set this bit to ‘0’ to enable the use of the system gain value when computing the final offset and gain corrected data value. NOSYSO The ‘no system offset’ bit controls the use of the system offset calibration coefficient. Set this bit to ’1’ to disable the use of the system offset value when computing the final offset and gain corrected data value. Set this bit to ‘0’ to enable the use of the system offset value when computing the final offset and gain corrected data value. NOSCG The ‘no self-calibration gain’ bit controls the use of the self-calibration gain calibration coefficient. Set this bit to ‘1’ to disable the use of the self-calibration gain value when computing the final offset and gain corrected data value. Set this bit to ‘0’ to enable the use of the self-calibration gain value when computing the final offset and gain corrected data value. NOSCO The ‘no self-calibration offset’ bit controls the use of the self-calibration offset calibration coefficient. Set this bit to ‘1’ to disable the use of the self-calibration offset value when computing the final offset and gain corrected data value. Set this bit to ‘0’ to enable the use of the self-calibration offset value when computing the final offset and gain corrected data value. www.maximintegrated.com Maxim Integrated │  43 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface GPIO_CTRL: GPIO Control Register (Read/Write) Default = 0x4x BIT NAME GPIO1_EN GPIO0_EN DIR1 DIR0 DIO1 DIO0 DEFAULT 0 1 0 0 X X This register controls the direction and values of the general-purpose I/O (GPIO) pins. BIT NAME DESCRIPTION GPIO1_EN This bit selects the functionality of the GPIO1/SYNC pin. Set this bit to ‘1’ to use the pin as GPIO, or set the bit to ‘0’ to use the pin as SYNC input. GPIO0_EN This bit selects the functionality of the GPIO0/CLK pin. Set this bit to ‘1’ to use the pin as GPIO, or set the bit to ‘0’ to use the pin as external clock input. DIR[1:0] The ‘direction’ bits configure the GPIO pins either as input or output. DIR1 corresponds to GPIO1, while DIR0 controls GPIO0. Set the DIR bit to ‘1’ to configure the GPIO pin as output. The output value of the GPIO pin is determined by the value of the DIO bit. Set the DIR bit to ‘0’ to configure the associated GPIO pin as input. The logic input value of the GPIO pin can be read back from the DIO bit. DIO[1:0] The ‘data input/output’ bits reflect the status of the GPIO pins. DIO1 corresponds to GPIO1, while DIO0 corresponds to GPIO0. If the GPIO pin is configured as output, the pin is driven to the logic value of DIO. If the GPIO pin is configured as input, DIO reflects the logic value seen at the pin. DELAY: Delay Register (Read/Write) Default = 0x0000 BIT NAME MUX[7:0] GPO[7:0] DEFAULT 0x00 0x00 BIT NAME DESCRIPTION MUX[7:0] Used to program the mux delay. The mux delay ranges from 4µs to 1.02ms. The default value of 0x00 corresponds to no delay. 1 LSB = 4µs of delay. GPO[7:0] Used to program the GPO/GPIO delay. The GPO/GPIO delay ranges from 20µs to 5.1ms. The default value of 0x00 corresponds to no delay. 1 LSB = 20µs of delay. www.maximintegrated.com Maxim Integrated │  44 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface CHMAP1: Channel Map Register (Read/Write) Default = 0x00_0000 BIT NAME CH5_GPO1 CH5_GPO0 CH5_ORD2 CH5_ORD1 CH5_ORD0 CH5_EN CH5_GPOEN DEFAULT 0 0 0 0 0 0 0 BIT NAME CH4_GPO1 CH4_GPO0 CH4_ORD2 CH4_ORD1 CH4_ORD0 CH4_EN CH4_GPOEN DEFAULT 0 0 0 0 0 0 0 BIT NAME CH3_GPO1 CH3_GPO0 CH3_ORD2 CH3_ORD1 CH3_ORD0 CH3_EN CH3_GPOEN DEFAULT 0 0 0 0 0 0 0 CH2_ORD1 CH2_ORD0 CH2_EN CH2_GPOEN CHMAP0: Channel Map Register (Read/Write) Default = 0x00_0000 BIT NAME CH2_GPO1 CH2_GPO0 CH2_ORD2 DEFAULT 0 0 0 0 0 0 0 BIT NAME CH1_GPO1 CH1_GPO0 CH1_ORD2 CH1_ORD1 CH1_ORD0 CH1_EN CH1_GPOEN DEFAULT 0 0 0 0 0 0 0 BIT NAME CH0_GPO1 CH0_GPO0 CH0_ORD2 CH0_ORD1 CH0_ORD0 CH0_EN CH0_GPOEN DEFAULT 0 0 0 0 0 0 0 These registers are used to enable channels for scan, enable GPO/GPIO pins for scan, program the channel scan order, and pair the GPO/GPIO pins with its associated channel. These registers cannot be written during an active conversion. BIT NAME DESCRIPTION Used to map which GPO or GPIO pin is activated when this channel is selected. The STAT:GPOERR flag is set if more than one input channel is mapped to the same GPO/GPIO pin. The decoding is as follows: CHX_GPO[1:0] CHX_GPO1 CHX_GPO0 0 0 GPO0 DESCRIPTION 0 1 GPO1 1 0 GPIO0 1 1 GPIO1 CHX_ORD[2:0] Defines the order during scan when the channel is enabled. The CHX_ORD[2:0] values of ‘000’ and ‘111’ are not allowed for the order of an enabled channel. The allowable orders are ‘001’, ‘010’, ‘011’, ‘100’, ‘101’, ‘110’ representing first, second, third channel to be scanned, and so on. The value of ‘000’ is a default value and the value of ‘111’ is greater than the number of scannable channels. A value greater than the number of enabled channels is invalid and will set an error condition at STAT:ORDERR. Setting a channel’s order to ‘000’ or ‘111’ and enabling it will set the STAT:ORDERR flag in the STAT register. If sequencer mode 3 is selected, and more channels are enabled for sequencing than available GPO/ GPIO pins, then the sequence order of the channels for which a GPO/GPIO pin is enabled must be lower than for the channels which do not have a GPO/GPIO pin mapped to them. CHX_EN Set this bit to ‘1’ to enable scanning of this channel. Set this bit to ‘0’ to disable scanning of this channel. CHX_GPOEN Used to enable activation of the GPO/GPIO pins when this channel is selected during scan. Set this bit to ‘1’ to enable. Set this bit to ‘0’ to disable. www.maximintegrated.com Maxim Integrated │  45 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface SEQ: Sequencer Register (Read/Write) Default = 0x00 BIT NAME MUX2 MUX1 MUX0 MODE1 MODE0 GPODREN MDREN RDYBEN DEFAULT 0 0 0 0 0 0 0 0 This register is used to control the operation of the sequencer when enabled. BIT NAME MUX[2:0] DESCRIPTION Binary channel selection for sequencer mode 1. Valid channels are from 000 (channel 0) to 101 (channel 5). Sequencer mode is decoded as shown in the following table: MODE[1:0] GPODREN MODE1 MODE0 DESCRIPTION 0 0 Sequencer Mode 1 0 1 Sequencer Mode 2 1 0 Sequencer Mode 3 1 1 Reserved. Do not use. GPO/GPIO delay enable. Enables operation of the GPO/GPIO switch delay. When enabled, the channel selection is delayed. The value of the delay is set by the DELAY:GPO bits. MDREN MUX delay enable. Enables the timer setting in the DELAY:MUX register to delay the conversion start of the selected channel. RDYBEN Ready Bar enable. When this bit is ‘1’ the RDYB is inhibited from asserting in sequencer mode 2 and 3 until all channels are converted GPO_DIR: GPO Direct Access Register (Read/Write) Default = 0x00 BIT NAME GPO1 GPO0 DEFAULT 0 0 This register is used to turn on and off the general-purpose outputs directly after an associated bit is written except when CTRL3:GPO_MODE=’1’ during sequencer mode 3. When operating in sequencer mode 1 or 2, the activation of the GPOs is immediate upon setting a bit to ’1’, and the deactivation of the GPOs is immediate upon setting the bit to ‘0’. In SLEEP state, the values in this register do not control the state of the GPOs, as they all are deactivated. The register is writeable, but the values will not control the GPOs in SLEEP mode. In STANDBY state when CTRL3:GPO_MODE=’0’, this register accepts writes and updates the state of the GPOs immediately after the value of a bit changes. Writes to this register are ignored when operating in mode 3 when CTRL3:GPO_MODE=’1’. This register is enabled during system offset calibration, system gain calibration and self-calibration modes. www.maximintegrated.com Maxim Integrated │  46 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface SOC: System Offset Calibration Register (Read/Write) Default = 0x00_0000 BIT NAME B23 B22 B21 …. B3 B2 B1 B0 DEFAULT 0 0 0 …. 0 0 0 0 The system offset calibration register is a 24-bit read/write register. The data written/read to/from this register is clocked in/out MSB first. This register holds the system offset calibration value. The format is in two’s complement binary format. A system calibration does not overwrite the SOC register. The readback value of this register depends on CTRL3:CALREGSEL. A ‘1’ reads back the user programmed value. A ‘0’ reads back the results of an internal register as described in CTRL3:CALREGSEL. The internal register can only be read during conversion. The system offset calibration value is subtracted from each conversion result—provided the NOSYSO bit in the CTRL3 register is set to ‘0’. The system offset calibration value is subtracted from the conversion result after self-calibration but before system gain correction. It is also applied prior to the 1x or 2x scale factor associated with bipolar and unipolar modes. When a system offset calibration is in progress, this register is not writable by the user. SGC: System Gain Calibration Register (Read/Write) Default = 0x7F_FFFF BIT NAME B23 B22 B21 …. B3 B2 B1 B0 DEFAULT 0 1 1 …. 1 1 1 1 The system gain calibration register is a 24-bit read/write register. The data written/read to/from this register is clocked in/out MSB first. This register holds the system gain calibration value. The format is unsigned 24-bit binary. A system calibration does not overwrite the SGC register. The readback value of this register depends on CTRL3:CALREGSEL. A ‘1’ reads back the user programmed value. A ‘0’ reads back the results of an internal register as described in CTRL3:CALREGSEL. The internal register can only be read during conversion. The system gain calibration value is used to scale the offset corrected conversion result—provided the NOSYSG bit in the CTRL3 register is set to ‘0’. The system gain calibration value scales the offset corrected result by up to 2x or can correct a gain error of approximately -50%. The amount of positive gain error that can be corrected is determined by modulator overload characteristics, which may be as much as +25%. When a system gain calibration is in progress, this register is not writable by the user. www.maximintegrated.com Maxim Integrated │  47 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface SCOC: Self-Calibration Offset Calibration Register (Read/Write) Default = 0x00_0000 BIT NAME B23 B22 B21 …. B3 B2 B1 B0 DEFAULT 0 0 0 …. 0 0 0 0 The self-calibration offset register is a 24-bit read/write register. The data written/read to/from this register is clocked in/out MSB first. This register holds the self-calibration offset value. The format is always in two’s complement binary format. An internal selfcalibration does not overwrite the SCOC register. The readback value of this register depends on CTRL3:CALREGSEL. A ‘1’ reads back the user programmed value. A ‘0’ reads back the results of an internal register as described in CTRL3:CALREGSEL. The internal register can only be read during conversion. The self-calibration offset value is subtracted from each conversion result—provided the NOSCO bit in the CTRL3 register is set to ‘0’. The self-calibration offset value is subtracted from the conversion result before the self-calibration gain correction and before the system offset and gain correction. It is also applied prior to the 2x scale factor associated with unipolar mode. When a self-calibration is in progress, this register is not writable by the user. SCGC: Self-Calibration Gain Calibration Register (Read/Write) Default = 0xBF_851B BIT NAME B23 B22 B21 …. B3 B2 B1 B0 DEFAULT 1 0 1 …. 1 0 1 1 The self-calibration gain register is a 24-bit read/write register. The data written/read to/from this register is clocked in/out MSB first. This register holds the self-calibration gain value. The format is unsigned 24-bit binary. An internal self- calibration does not overwrite the SCGC register. The readback value of this register depends on CTRL3:CALREGSEL. A ‘1’ reads back the user programmed value. A ‘0’ reads back the results of an internal register as described in CTRL3:CALREGSEL. The internal register can only be read during conversion. The self-calibration gain calibration value is used to scale the self-calibration offset corrected conversion result before the system offset and gain calibration values have been applied – provided the NOSCG bit in the CTRL3 register is set to ‘0’. The self-calibration gain calibration value scales the self-calibration offset corrected conversion result by up to 2x or can correct a gain error of approximately –50%. The gain will be corrected to within 2 LSB. When a self- calibration is in progress, this register is not writable by the user. www.maximintegrated.com Maxim Integrated │  48 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface DATA[5:0]: Data Registers (Read Only) Default = 0x00_0000 BIT NAME D23 D22 D21 … D3 D2 D1 D0 DEFAULT 0 0 0 … 0 0 0 0 Each data register holds the conversion result for the corresponding channel. DATA0 is the data register for channel 0, DATA1 is for channel 1, etc. Each data register is a 24-bit read-only register. Any attempt to write data to this location will have no effect. The data read from these registers is clocked out MSB first. The result is stored in a format according to the FORMAT bit in the CTRL1 register. The data format while in unipolar mode is always offset binary. In offset binary format the most negative value is 0x000000, the midscale value is 0x800000 and the most positive value is 0xFFFFFF. In bipolar mode if the FORMAT bit = ‘1’ then the data format is offset binary. If the FORMAT bit = ‘0’, then the data format is two’s complement. In two’s complement the negative full-scale value is 0x800000, the midscale is 0x000000 and the positive full scale is 0x7FFFFF. Any input exceeding the available input range is limited to the minimum or maximum data value. www.maximintegrated.com Maxim Integrated │  49 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Chip Information Ordering Information PART TEMP RANGE PIN-PACKAGE MAX11254ATJ+ -40°C to +125°C 32 TQFN-EP* MAX11254ATJ+T -40°C to +125°C 32 TQFN-EP* MAX11254ATJ/V+ -40°C to +125°C 32 TQFN-EP* MAX11254ATJ/V+T -40°C to +125°C 32 TQFN-EP* PROCESS: CMOS +Denotes a lead(Pb)-free/RoHS-compliant package. T = Tape and reel. *EP = Exposed pad. Package Information For the latest package outline information and land patterns (footprints), go to www.maximintegrated.com/packages. Note that a “+”, “#”, or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package regardless of RoHS status. PART PACKAGE TYPE PACKAGE CODE OUTLINE NO. LAND PATTERN NO. MAX11254ATJ+ 32 TQFN T3255+4 21-0140 90-0012 MAX11254ATJ/V+ 32 TQFN T3255+4 21-0140 90-0012 www.maximintegrated.com Maxim Integrated │  50 MAX11254 24-Bit, 6-Channel, 64ksps, 6.2nV/√Hz PGA, Delta-Sigma ADC with SPI Interface Revision History REVISION NUMBER REVISION DATE PAGES CHANGED 0 3/15 Initial release 1 4/15 Revised Typical Operating Characteristics section 2 8/17 Adding MAX11254ATJ/V+ as future product to Ordering Information table. Updated Package Information table 50 3 3/18 Updated Ordering Information table 50 4 9/18 Updated Benefits and Features section 1 5 9/18 Updated Applications section 1 DESCRIPTION — 10, 11 For pricing, delivery, and ordering information, please visit Maxim Integrated’s online storefront at https://www.maximintegrated.com/en/storefront/storefront.html. Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance. Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc. © 2018 Maxim Integrated Products, Inc. │  51
MAX11254ATJ/V+ 价格&库存

很抱歉,暂时无法提供与“MAX11254ATJ/V+”相匹配的价格&库存,您可以联系我们找货

免费人工找货