0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LPS200-M

LPS200-M

  • 厂商:

    EMERSON-NETWORKPOWER

  • 封装:

  • 描述:

    LPS200-M - Medical and ITE safeties - Emerson Network Power

  • 数据手册
  • 价格&库存
LPS200-M 数据手册
Embedded Power for Business-Critical Continuity LPS200-M Series 250 Watts Total Power: Input Voltage: # of Outputs: 125 - 250 Watts 90 - 264 Vac Single Rev. 4.30.09_#98 LPS200-M Series  of 3 Special Features • • • • • • • • • • • • • • Medical and ITE safeties Active power factor correction 3” x 5” footprint Less than 1U high EN61000-3-2 compliant Remote sense Power fail Adjustable main output Built-in Class B EMI filter Overvoltage protection Overload protection Thermal overload protection Isolated 12V Fan output LPX80 enclosure available Electrical Specifications Input Input range: Frequency: Inrush current: Efficiency: EMI/RFI: Power factor: Safety ground leakage current: 90 - 264 Vac; 120 - 300 Vdc 47-63 Hz 50 A max., cold start @ 25 °C 86% typical at full load FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted 0.99 typical 2 75 uA @ 50/60 Hz, 264 Vac input Output Maximum power: Adjustment range: Fan output: Hold-up time: Overload protection: 125 W for convection ; 250 W (200 W for LPS202-M) with 30CFM forced air ±10% minimum on the main outputs 12 V @ 1 A isolated, ±10% 16 ms @ 250 W load, 120 Vac input Short circuit protection on all outputs. Case overload protected @ 110-160% above rating Overvoltage protection: 15-50% above nominal output Logical Control Power failure: Open collector logic signal goes high 100-500 msec after main output; it goes low at least 6 msec before loss of regulation C ompensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Safety • • • • • • TUV 60950, 60601-1 UL 60950, 60601-1 cULus 60950, 60601-1 TUV 60950, 60601-1 CB Certificate & report CE Mark (LVD) Remote sense: Embedded Power for Business-Critical Continuity Environmental Specifications Operating temperature: Storage temperature: Electromagnetic susceptibility: Humidity: Vibration: MTBF demonstrated: 0° to 50 °C ambient derate each output as 2.5% per degree from 50° to 70 °C. -20 °C start up -40 °C to +85 °C Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Operating; non-condensing 10% to 95% RH IEC68-2-6 to the levels of IEC721-3-2 >550,000 hours at full load and 25 °C ambient conditions Rev. 4.30.09_#98 LPS200-M Series 2 of 3 Ordering Information Model Number LPS202-M LPS203-M LPS204-M LPS205-M LPS208-M Output Voltage 5 V 12 V 15 V 24 V 48 V Minimum Load 0 A 0 A 0 A 0 A 0 A Maximum Load with Convection Cooling 20 A 10.3 A 8.3 A 5.2 A 2.6 A Maximum Load with 30CFM Forced Air 40 A 20.8 A 16 A 10.4 A 5.2 A Peak Load Regulation2 44 A 22 A 18 A 11.5 A 5.8 A ±2% ±2% ±2% ±2% ±2% Ripple P/P (PARD)3 50 mV 120 mV 150 mV 240 mV 480 mV 1. Peak current lasting
LPS200-M 价格&库存

很抱歉,暂时无法提供与“LPS200-M”相匹配的价格&库存,您可以联系我们找货

免费人工找货