EDSX10-60M

EDSX10-60M

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDSX10-60M - MICROJET RECORDER (180mm) - Fuji Electric

  • 数据手册
  • 价格&库存
EDSX10-60M 数据手册
MICROJET RECORDER (180mm) DATA SHEET This recorder can record a maximum of 12 channels of DC voltage, mA, thermocouples and resistance bulbs. The adoption of an ink jet system makes it possible to record measured data in analog trace mode or to print in digital mode at a high speed. This 180mm-wide recorder performs recording clearly in 6 different colors. PHA FEATURES 1. Compact size Compact and lightweight design, 199mm in depth and about 6kg in mass{weight}. 2. High quality recording • Ink jet system is used for recording and printing measured data in 6 different colors at a high speed. Operating noise is minimized. • Six and twelve continuous traces without pen offset are possible with this compact size of recorder; a unique recording system is used for the first time in the industry. • Scale of each channel is printed on chart paper, elimi- nating the need for scales. 3. Easy setting of input signals DC voltage input (5mV span, 50V max.), 12 kinds of thermocouples (Type B, R, S, K, E, J, T, N, W, L, U, PN) and resistance bulbs (Pt100) can be set for each channel. 4. Digital printing Beside the analog recording of measured data, digital printing is also available (periodic printing, list printing, alarm printing, daily report printing, message printing). • Periodic data printing: Channel No., date, time, unit, chart speed, measured value • List printing: Date, time, unit, recording range, scaling value, alarm set value, chart speed, Tag No. • Alarm printing: Channel No., alarm type, on/off time, output relay No. • Daily report and totalized data printing: Printing of maximum, minimum, average and total of data measured during maximum 24 hours • Message printing : 10 messages, 16-character userentered messages 5. Interactive key operation Fluorescent indicator is used to clearly indicate alphanumeric characters and symbols. Input mode, recording range, alarm value, chart speed, etc., can be set according to the comments indicated by the display and operating keys. No bothersome operation is required. 6. Easy handling • A cartridge type recording device is used for easy replacement. • Chart paper can be loaded without drawing out the internal unit of the recorder. • Shortage of ink is detected in early stages and an alarm is given to the operator. • The end of chart paper is detected and indicated on the front panel display. • Shortage of ink and the end of chart paper alarm output is possible. 7. Full variety of functions • Alarm relay output/external control (record start/ stop, chart speed change, data printing, message printing). This unit can easily be connected to the recorder by user (option). • Chart paper illumination lamp (option): The result of printing can be checked even in lower light. • Burnout function is provided as a standard. • Various recording: Enlarged/reduced recording, auto-range recording, zone recording. • Calculation: Square root extraction, subtraction, engineering unit conversion, logarithm. • Language: Selectable 3 languages in display and printing. • Passcode security is configurable. • The message print and alarm print function are operational, even when the recording mode is off. • All parameters of recording format, daily report, totalize, message and periodic data printing can be printed cut. EDSX10-60m Date Nov. 24, 2011 PHA SPECIFICATIONS Input system 6 or 12 continuous recording and intermittent recording Input signal: Thermocouple input…B, R, S, K, E, J, T, N, W, L, U, PN Resistance bulb input…Pt100Ω DC voltage input…50mV, 500mV, 5V, 50V range DC current input…4 to 20mA DC, 10 to 50mA DC (Shunt resistor (option) need to be connected to the terminal) Max. input voltage: • Thermocouple, resistance bulb and DC voltage (50mV, 500mV range) …±10V DC or less • DC voltage input (5V, 50V range) …±100V DC or less Input signal setting and change: Setting and change of input signal between thermocouple, resistance bulb and DC voltage (50mV, 500mV, 5V, 50V range) is possible for each channel by the setting pin in the instrument. Setting of recording range: Setting is possible within the reference range by using the keyboard. Burnout function:When thermocouple or resistance bulb input is disconnected, the recording is deflected to 100%. Reference range: Kind Thermo- couple Resistance bulb DC voltage Note: N W L U PN Pt100 B R S K E J T N W L U PN Pt100 Reference range 400 to 1760°C 0 to 1760°C 0 to 1760°C –200 to 1370°C –200 to 800°C –200 to 1100°C –200 to 400°C 0 to 1300°C 0 to 1760°C –200 to 900°C –200 to 400°C 0 to 1300°C –200 to 600°C –50 –500 –5 –50 to +50mV to +500mV to +5V to +50V Reference range 752 to 3200°F 32 to 3200°F 32 to 3200°F –328 to 2498°F –328 to 1472°F –328 to 2012°F –328 to 752°F 32 to 2372°F 32 to 3200°F –328 to 1652°F –328 to 752°F 32 to 2372°F –328 to 1112°F Scaling is possible within the range of –32767 to +32767 (decimal point may be put as necessary) Chart speeds: Input points: Continuous recording type 5 to 300 mm/h, continuous recording 301 to 1500 mm/h, intermittent recording Intermitter recording type 5 to 1500 mm/h Each can be set in 1 mm/h steps. Recording cycle: Intermitter recording…30sec/all points Continuous recording…Depends on chart speed. Recording 450 = cycle[sec] Chart speed [mm/h] (not faster than 3 seconds.) Measuring cycle: Up to 3 inputs…160ms 6, 12 inputs…320ms Service life of ink: (Depends on operating conditions) About 6 months for 6 points of linear recording at 25 mm/h of chart speed Chart handling: Tear off without disturbance of recording. : NICROSIL-NISIL (IEC584) : +side 5% Re, –side 26% Re.W (Hoskins Mfg. Co., U.S.A.) : +side Fe, –side Cu.Ni alloy (DIN43710) : +side Cu, –side Cu.Ni alloy (DIN43710) : Platinel : DIN IEC751 Recording system Writing system: Ink jet system, 6 colors Chart width: 180mm Recording color: No. 1,7 channel (orange), No. 2.8 channel (green), No. 3, 9 channel (purple), No. 4, 10 channel (red), No. 5, 11 channel (black), No. 6, 12 channel (blue) Recording color can be assigned for each channel. Chart length: Z fold 20m Indication: Fluorescent indication (blue-green), 20 characters × 2 lines Characters indicated: 5 × 7 dots, 5.0mm high, 3.5mm wide Contents of indication: (1) Measured value: T emperature…1 digit below decimal point; V oltage…6 digits (including sign and decimal point) M easured value of No.1 channel to No.6 or No.7 channel to No.12 can be indicated simultaneously. (2) Channel No.: 2 digit (1 to 12) (3) Engineering unit: M ax. 7 digits (°C, °F, %, Pa, bar, ppm, m3/h, etc.) (4) Tag No….8 characters (5) Time: Year, month, day, hour, minute (6) Status indication: Record ON, chart end, battery alarm, alarm, ink shortage alarm, burnout, carriage failure Configuration: These can be set according to the comments indicated by operating keys as follows, Passcode Main chart speed Sub chart speed Alarm setting Record mode (trend/logging) Recording range Input signal List print request Tag No. Daily report setting Totalize function Communication parameter Date and time setting Ink monitor clear Illumination on/off Message definition Measured value shift Indicating system 2 Writing system: Ink jet system, 6 colors Periodic data printing: Measured value, unit, date, time, time line, chart speed, channel No. List printing: (1) easured value list (date, time, channel No., meaM sured value, unit) (2) arameter list (date, time, channel No., recording range, P scaling, unit, alarm set value, chart speed, Tag No.) (3) est pattern (all characters and color patterns) T Message printing: 1 0 m e s s a g e s , 1 6 - c h a r a c t e r u s e rentered messages. Alarm printing: Channel No., alarm type (H, L, RH, RL), output relay No., on/off time Burnout printing: Burnout channel No. and time Other: Ink shortage message, automatic range selection mark, recording start mark, chart speed change mark Note: Printing is not available for more than 301 mm/h (continuous recording), or more than 51 mm/h (intermittent recording). Printing system Performance and characteristics Accuracy and resolution: Performance under reference condition (23±2°C, 65±10%RH, power voltage and frequency variation ±1%, warm-up time 30 minutes or more, vertical mounting, free from the effect of external noise) Input Thermo- couple Resistance bulb DC voltage B R S K E J T N W L U PN Pt100 –50 to +50mV –500 to +500mV –5 to 5V –50 to 50V Indication (digital) ResoAccuracy lution 0.1°C 0.1°C ±(0.15% 0.1°C 0.1°C +1 digit) 0.1°C (without reference 0.1°C 0.1°C junction 0.1°C compen 0.1°C sation 0.1°C error) 0.1°C 0.1°C ±(0.15% +1 digit) ±(0.15% +1 digit) 0.1°C 10 µV 100 µV 1mV 10mV Recording Accuracy Resolution Power supply terminal - ground …2000V AC, 1 minute Input terminal - ground …500V AC, 1 minute Power terminal - input terminal …500V AC, 1 minute Between alarm terminals …750V AC, 1 minute ( eakage current 5mA or less, howL ever, if the power supply is 24V DC, Leakage current of “Power supply terminal - ground” is 10mA or less) Reference junction compensation accuracy: K, E, J, T, N, L, U, PN ..... ....... ±0.5°C (In case of minus input measurement: ±1.2°C) R, S, B, W ............................. ±1°C (In case of minus input measurement: ±2.4°C) Common mode noise rejection: 120dB at 50, 60Hz ±0.1Hz Series mode noise rejection: 30dB at 50, 60Hz ±0.1Hz Physical data Mounting: Panel (may be inclined up to 30° backwards from the vertical.) =90° to 60° Indication accuracy, ±0.25% of recording span 0.1mm minimum Case...Steel plate Front door frame…Polycarbonate with glass wool Mass{weight}: Approx. 6 kg (without option) Approx. 7 kg (with option) Case size: Bezel 288x288mm Depth 199mm Cutout 281x281mm Finish color: Case…Black, Front door frame…Black External terminals: Screw terminal (M4 screw) Material: Power requirement 1) upply voltage 100 to 240V AC products (9digit of S code symbol = “E”) • Power supply voltage: 1 00V (-15%) to 240V (+10%) AC (Free power supply) • Supply frequency: Note: Indication accuracy is in % of reference range. Indication accuracy of B type TC is ±(0.36%+1digit) between 400°C to 600°C. Indication accuracy of all type TC is ±(0.36%+1digit) between –200°C to –100°C. Input resistance: Thermocouple:>10MΩ 50mV range: >10MΩ 500mV range: >100kΩ 5V and 50V range: >1MΩ Chart speed accuracy: ±0.1% (expansion and contraction of paper is not included) Clock accuracy: ±50ppm or less (monthly error; about 2 minutes) Insulation resistance: 100MΩ or more (between each terminal and earth, at 500V DC) Withstand voltage: Input terminal - input terminal …500V AC, 1 minute 50/60Hz both employable • Power consumption: 1 00V AC with all options approximately 37VA 2 40V AC with all options approximately 56VA 2) upply voltage 24V DC products (9digit of code symS bol = “L”) • Power supply voltage: 24V (±10%) DC • Power consumption: 2 6.4V DC with all options 37VA or less 3 PHA Operating environment (for devices to operate continuously) Temperature limits: 0 to 50°C Humidity limits: 20 to 80%RH, non condensing is required (temperature x humidity
EDSX10-60M 价格&库存

很抱歉,暂时无法提供与“EDSX10-60M”相匹配的价格&库存,您可以联系我们找货

免费人工找货