0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDSX5-73

EDSX5-73

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDSX5-73 - FCX – AX SERIES PRESSURE TRANSMITTER - Fuji Electric

  • 数据手册
  • 价格&库存
EDSX5-73 数据手册
FCX – AX SERIES DATA SHEET PRESSURE TRANSMITTER FHG,FKG...3 The FCX – AX pressure transmitter accurately measures gauge pressure and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor tech- nology to provide exceptional performance and functionality. FEATURES 1. High accuracy 0.07% accuracy for all calibrated spans is a standard feature for pressure transmitter covering 6.4 to 50000kPa {0.064 to 500bar}. Fuji’s micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 2. Minimum environmental influence The “Advance Floating Cell” design which protects the pressure sensor against changes in temperature, and overpressure substantially reduces total measurement error in actual field applications. 3. Replaceable Communication Module Fuji micro-electronics manufacturing technology offers replaceable communication module that makes FCX – AX transmitter very unique in design. In case of change in communication protocol, all that needs to be done is just to replace the module and the transmitter gets upgraded to the new version. 4. Fuji/HART bilingual communication module The communication module is "bilingual" to speak both Fuji proprietary protocol and HART. Any HART compatible devices can communicate with FCX – AX series transmitters. 5. Application flexibility Various options that render the FCX – AX suitable for almost any process applications include: — Analog indicator at either the electronics side or terminal side — Full range of hazardous area approvals — Built-in RFI filter and lightning arrester — 4 1 -digits LCD meter 2 — Stainless steel electronics housing 6. Burnout current flexibility (Under Scale: 3.2 to 3.8mA, Over Scale: 20.8 to 21.6mA) Burnout signal level is adjustable using Model FXW hand Held Communicator (HHC) to comply with NAMUR NE43. (Available for amplifier unit from version 24 and FXW(HHC) version 5.3.) SPECIFICATIONS Functional specifications Type: Model FHG: Model FKG: Service: Span, range and 4 to 20mA 4 to 20mA with digital signal Liquid, gas, or vapour overrange limit: Range limit [kPa] {bar} Overrange limit [MPa] {bar} 1 {10} 1.5 {15} 9 {90} 15 {150} 75 {750} Span limit [kPa] {bar} Type FHG F G 01 F G 02 F G 03 F G 04 F G 05 6.4 {0.064} 50 {0.5} 300 {3} 1000 {10} 5000 {50} Min. FKG 0.64 {0.0064} 5 {0.05} 30 {0.3} 100 {1} 500 {5} Max. FHG/FKG 64 {0.64} 500 {5} 3000 {30} 10000 {100} 50000 {500} –64 to + 64 {–0.64 to +0.64} –100 to +500 {–1 to + 5} –100 to +3000 {–1 to + 30} –100 to +10000 {–1 to + 100 } –100 to +50000 {–1 to + 500} Remark: To minimize environmental influence, span should be greater than 1/40 of the max. span in most applications. 7. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. — Lower range limit (vacuum limit) ; Silicone fill sensor: See Fig. 1 Fluorinated fill sensor: 66kPa abs (500mmHg abs) at below 60°C — Conversion factors to different units; 1 MPa=103 kPa=10bar=10.19716kgf/cm2= 145.0377psi 1kPa=10mbar=101.9716mmH2O =4.01463inH2O Output signal: Model FHG: 4 to 20mA DC 2-wire Model FKG: 4 to 20mA DC with digital signal superimposed on the 4 to 20mA signal. EDSX5-73 EDS5-62b Date Mar. 15, 1999 FHG, FKG...3 Power supply: Transmitter operates on 11V to 45V DC at transmitter terminals. 11V to 32V DC for the units with optional arrester. Load limitations: see figure below [Ω] 2000 1533Ω 1500 1000 500 250 10 600Ω Operating area 24V 16.1 10.5V Power voltage 45V 50 [V] Model FHG: Unless otherwise specified in the order, the transmitter will be shipped in “Output Hold” mode. (Output signal just before failure happens is maintained.) Model FKG: Selectable from HHC “Output Hold”: Output signal is hold as the value just before failure happens. “Output Overscale”: Approx. 21.6mA (Adjustable within the range 20.8mA to 21.6mA from HHC) “Output Underscale”: Approx. 3.8mA (Adjustable within the range 3.2mA to 3.8mA from HHC) 3.2 3.8 4 20 20.8 Over scale Burnout 0 Normal operating range Under scale Probable under range Burnout 21.6 Probable over range Note: For communication with HHC (Model: FXW), min. of 250 Ω required. Hazardous locations: (Approval pending) Authorities BASEEFA Factory Mutual CSA Flameproof Ex ds IIC T5, T6 Class I II III Div. 1 Groups B thru. G Class I II III Div. 1 Groups C thru. G Ex ds IIB+H2 T4 Ex d II C T5, T6 IP 66/67 Intrinsic safety EEx ia IIC T4, T5 Class I II III Div. 1 Groups A thru. F Class I II III Div. 1 Groups A thru. G — Ex ia II C T5, T6 IP 66/67 Type N Nonincendive Ex N II T5 Class I II III Div. 2 Groups A thru. G Class I II III Div. 2 Groups A thru. G — Ex n II C T5, T6 IP 66/67 Load resistance RIIS SAA Zero/span adjustment: Model FHG: Zero is adjustable from the external adjustment screw. The adjustment screw can also function to adjust span when MODE SWITCH (located on the electronics unit) is in the span mode. INHIBIT mode to disable the adjustment screw is also available. Model FKG: Zero and span are adjustable from the HHC. Zero is also adjustable externally from the adjustment screw. Damping: Adjustable electrical damping. Model FHG: The time constant is adjustable to 0, 0.3, 1.2, 4.8, or 19.2 seconds. Model FKG: The time constant is adjustable between 0 to 38.4 seconds. (9 steps) Zero elevation/suppression: Zero can be elevated or suppressed within the specified range limit of each sensor model. Normal/reverse action: Selectable by moving a jumper pin located on the electronics unit. Indication: Analog indicator or 4 1 -digit LCD meter, as 2 specified. Burnout direction: If self-diagnostic detect transmitter failure, the analog signal will be driven to either “Output Hold”, “Output Overscale” or “Output Underscale” modes. Loop-check output: Model FHG: Transmitter can output a constant signal of 4mA, 12mA, or 20mA if MODE SWITCH is set to the loop check mode. Model FKG: Transmitter can be configured to provide constant signal 3.8mA through 21.6mA by HHC. Temperature limit: Ambient: – 40 to +85°C (–20 to +80°C for LCD indicator) (– 40 to +60°C for arrester option) (–10 to +60 ° C for fluorinated oil fill transmitter) For explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified by each standard. Process: – 40 to +100 °C for silicone fill sensor –20 to +80°C for fluorinated oil fill sensor Storage: –40 to +90°C Humidity limit: 0 to 100% RH Communication: (Model FKG only) With HHC (Model FXW, consult Data Sheet No. EDS8-47), following information can be remotely displayed or reconfigured. Items Tag No. Model No. Serial No. Engineering unit Range limit Measuring range Damping Output mode Burnout direction Adjustment Output adjust Data Self diagnoses Printer External switch lock Transmitter display(*) Display Set v v v v v v v v v v — v v — v v v v — v — v v v v v v — — — v v Note: (*) HHC's version must be more than 5.0 (or FXW 1 – 2 ), to use this function. 2 Performance specifications Accuracy rating: (including linearity, hysteresis, and repeatability) Max span below 10000kPa model: For spans greater than 1/10 of URL: ± 0.07% of span For spans below 1/10 of URL (Model FKG only): 0.1 × URL ± 0.02+0.05 % of span Span Max span 50000kPa model: For spans greater than 1/10 of URL: ± 0.1% of span For spans below 1/10 of URL (Model FKG only): 0.1 × URL ± 0.05+0.05 % of span Span Linearity: 0.05% of calibrated span Stability: ± 0.1% of upper range limit (URL) for 24 months Temperature effect: Effects per 28°C change between the limits of –40°C and +85°C URL Zero shift: ± (0.1+0.025 )% /28°C span URL Total effect: ± (0.125+0.025 )%/28°C span Double the effects for material code (7th digit in Code symbols) "H", "M", "T", "B", "L" and "U". Overrange effect: Zero shift; 0.2% of URL for any overrange to maximum limit Supply voltage effect: Less than 0.05% of calibrated span per 10V RFI effect: Less than 0.2% of URL for the frequencies of 20 to 1000MHz and field strength 30 V/m when electronics covers on. (Classification: 2-abc: 0.2% span per SAMA PMC 33.1) Step response: Time constant: 0.2s Dead time: approximately 0.3s (without electrical damping) Mounting position effect: Zero shift, less than 0.1kPa {1m bar} for a 10° tilt in any plane. No effect on span. This error can be corrected by adjusting Zero. (Double the effect for fluorinated fill sensors) Dielectric strength: 500V AC, 50/60Hz 1 min., between circuit and earth. Insulation resistance: More than 100MΩ at 500V DC. Turn-on time: 4 sec. Internal resistance for external field indicator: 12Ω or less Physical specifications Electrical connections: G1/2, 1/2-14 NPT, Pg13.5, or M20 × 1.5 conduit, as specified. Process connections: 1/4-18 NPT or Rc1/4 as specified. Process-wetted parts material: Material code (7th digit Process cover in Code symbols) V H M T B L U Wetted sensor body ( ( ) Diaphragm Vent/drain ) 316 stainless 316L stainless steel steel(*1) 316 stainless Hastelloy-C steel(*1) Monel 316 stainless steel(*1) Tantalum 316 stainless steel(*1) Hastelloy-C Hastelloy-C lining Monel Monel lining Tantalum Tantalum lining 316 stainless steel Hastelloy-C lining Monel lining Tantalum lining Hastelloy-C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel Hastelloy-C Monel Tantalum Note: *(1) SCS14 per JIS G 5121 Remark: Sensor O-rings: Viton and teflon selectable Availability of above material design depends on ranges. Refer to “Code symbols”. Non-wetted parts material: Electronics housing: Low copper die-cast aluminum alloy (standard), finished with polyester coating, or 316 stainless steel (SCS14 per JIS G5121), as specified. Bolts and nuts: Cr-Mo alloy (standard), or 304 stainless steel (630 stainless steel for 50MPa unit). Fill fluid: Silicone oil (standard) or fluorinated oil (Daifloil) Mounting bracket: Carbon steel with epoxy coating or 304 stainless steel, as specified Environmental protection: IEC IP67 and NEMA 4X Mounting: On 60.5mm (JIS 50A) pipe using mounting bracket, direct wall mounting, or direct process mounting. Mass {weight}: Transmitter approximately 3.4kg without options. Add; 0.5kg for mounting bracket 0.8kg for indicator option 4.5kg for stainless steel housing option 3 FHG, FKG...3 Optional features A plug-in analog indicator (1.5% accuracy) can be housed in the electronics compartment or in the terminal box of the housing. An optional 4 1 digits LCD meter is also 2 available. Arrester: A built-in arrester protects the electronics from lightning surges. Lightning surge immunity: 4KV (1.2 × 50µs) Oxygen service: Special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. The fill fluid is fluorinated oil. Chlorine service: The fill fluid is fluorinated oil. Degreasing: Process-wetted parts are cleaned, but the fill fluid is standard silicone oil. Not for use on oxygen or chlorine measurement. NACE specification: Metallic materials for all pressure boundary parts comply with NACE MR-01-75. ASTM B7M or L7M bolts and 2HM nuts (Class II) are available. Vacuum service: Special silicone oil and filling procedure are applied. See below figure. Indicator: ACCESSORIES Oval flanges: (Model FFP, refer to Data Sheet No. EDS6-10) Converts process connection to 1/2-14 NPT or to Rc1/2; in carbon steel or in 316 stainless steel. Hand-held communicator: (Model FXW, refer to Data Sheet No. EDS8-47) Communication module: (Standard for model FKG) By adding communication module, remote setting function becomes available for model FHG. Remark: When the communication module is connected, the operation mode of external zero/span adjustment screw is limited to zero adjustment only. The product conforms to the requirements of the Electromagnetic compatibility Directive 89/336/EEC as detailed within the technical construction file number TN510412. The applicable standards used to demonstrate compliance are :EMI (Emission) EN50081-1 : 1992 Test item Applicable Electromagnetic Radiation Disturbance Frequency range 30-1000MHz Basic standard EN55022 Class B Silicone oil (Code:Y,G,N) Silicone oil (Code:R) [kPa abs] {mbar abs} 101 {1010} Operating pressure Operating area 20 {200} EMS (Immunity) No. 1 Test item Electrostatic discharge EN50082-1 : 1992 Test specification 8kV (Air) Basic standard IEC 801-2:1984 Performance criteria B 2 Radio-frequency 27-500MHz electromagnetic 3V/m IEC 801-3:1984 field. (Unmodulated) Fast transients common mode 0.5kV, 5/50 (Tr/Th) ns 5kHz Rep. IEC 801-4:1988 A 3 4 {40} 2.7 {27} –40 B "LVD - The transmitter is not covered by the requirements of the LVD standard." None-operating area –15 60 85 120 Process temperature[°C ] Fig. 1 Relation between process temperature and operating pressure Customer tag: Coating of cell: A stainless steel tag with customer tag data is wired to the transmitter. Cell's surface is finished with epoxy/polyurethane double coating. Specify if environment is extermely corrosive. 4 CODE SYMBOLS 12345678 9 10 11 12 13 14 15 0 FHG FKG 3 Type 4 to 20mA, Output type 4 to 20mA with digital signal, Output type Connections Process connection Oval flange screwConduit 7/16-20UNF 7/16-20UNF M10 (or M12)(*1) M10 (or M12)(*1) 7/16-20UNF Description Conduit connection G 1/2 1/2-14NPT Pg 13.5 M20×1.5 Pg 13.5 S T V W X Rc1/4 1/4-18NPT 1/4-18NPT 1/4-18NPT 1/4-18NPT Span and materials Span limit FHG/FKG [kPa]{bar}(*2) 1V 1H 1M 1T 1B 1L 1U 2V 2H 2M 2T 2B 2L 2U 3V 3H 3M 3T 3B 3L 3U 4V 4H 4M 4T 4B 4L 4U 5V Process cover 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining 316stainless steel 316stainless steel 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel Diaphragm 316L stainless steel Hast. C Monel Tantalum Hast. C Monel Tantalum 316L stainless steel Hast. C Monel Tantalum Hast. C Monel Tantalum 316L stainless steel Hast. C Monel Tantalum Hast. C Monel Tantalum 316L stainless steel Hast. C Monel Tantalum Hast. C Monel Tantalum 316L stainless steel Wetted cell body 316 stainless steel Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel 6.4/0.64…64/64 {0.064/0.0064…0.64/0.64} 50/5…500/500 {0.5/0.05…5/5} 300/30…3000/3000 {3/0.3…30/30} 1000/100…10000/10000 {10/1…100/100} 5000/500…50000/50000 {50/5…500/500} Notes: * (1) For 50MPa {500bar} units, M12 is provided rather than M10. (2) 100: 1 turn down is possible for model FKG, but should be used at the span greater than 1/40 of the maximum span for better performance. 5 FHG, FKG...3 12345678 9 10 11 12 13 14 15 F HG F KG 0 0 3 3 Description Indicator and arrester Indicator Arrester None None Analog, 0 to 100% linear scale None Analog, custom scale None Analog, double scale None None Yes Analog, 0 to 100% linear scale Yes Analog, custom scale Yes Analog, double scale Yes Digital, 0 to 100% None Digital, custom scale None (Model FKG only) Digital, 0 to 100% Yes Digital, custom scale Yes (Model FKG only) Approvals for hazardous locations (Approval pending) None (for ordinary locations) JIS, Flameproof (Conduit seal) (Available for 4th digit code “S“) JIS, Flameproof (Cable gland seal) (Available for 4th digit code “S“) FM, Flameproof (or explosionproof) (Available for 4th digit code “T“) CSA, Flameproof (or explosionproof) (Available for 4th digit code “T“) BASEEFA, Flameproof (Conduit seal) BASEEFA, Flameproof (Cable gland seal) (Conduit connection G 1/2 only) FM, Intrinsic safety and Nonincendive CSA, Intrinsic safety and Nonincendive CENELEC, Intrinsic safety CENELEC, Intrinsic safety and BASEEFA, Type N SAA Flameproof (Conduit seal)(Available for 4th digit cord (“S,T,W) SAA Intrinsic safety (Available for 4th digit cord (“S,T,W) SAA Type–N (non-sparking)(Available for 4th digit cord (“S,T,W) Side vent/ drain and mounting bracket Side vent/drain Mounting bracket None None Specify "A", "B", or "C" for the 7th digit None Yes, carbon steel code "B", "L", or "U" None Yes, stainless steel A B D J E F H K L P Q S A B C D E M N H J K P R T Q A B C D E F } Y B C E M N P Q Yes None Yes Yes, carbon steel Yes Yes, stainless steel Stainless steel parts Stainless steel tag plate Stainless steel elec. housing None None Yes None None Yes Yes Yes None None Yes None None Yes Yes Yes Special applications and fill fluid Treatment None (standard) None (standard) Degreasing Oxygen service Chlorine service NACE specification Coating of cell None None None None Yes Yes Yes Yes Y W G A D N R A B A B C D E F * (1) Vacuum service Sensor O-ring Viton Teflon Bolt/nut Cr-Mo alloy hexagon socket head cap screw/carbon steel nut Cr-Mo alloy hexagon bolt/nut NACE bolt/nut (ASTM A193 B7M/A194 2HM) NACE bolt/nut (ASTM A320 L7M/A194 2HM) Not available for 6th digit code "5" 304 stainless steel/304 stainless steel (*1) 630 stainless steel/304 stainless steel (*1) } Available for 6th digit code "5" Fill fluid Silicone oil Fluorinated oil Silicone oil Fluorinated oil (7th digit code "V" only) Fluorinated oil (7th digit code "H", "T" ,"B", "U") Silicone oil (Not available for 6th digit code "5", 7th digit code "T", "U", 15th digit code "A", "B") Silicone oil for vacuum use } In case of tropical use, select stainless bolts and nuts. 6 OUTLINE DIAGRAM (Unit:mm) Fastener (In case of 10th digit code “B,C,M,N“) Zero/span ADJ. screw In case of 4th digit code “S,V,W,X“ Vent/drain plug (When the vent/drain plug attatched on the upper side of the detector) Mtg. Pipe JIS 50A (2") “A“ Press. conn. 43.5 Up 110 126.5 70 88 50 104 ø80 Down “B“ Conduit conn. With field ind. (option) Earth terminal (both side ) see table1 51 71 (27) 38 30 224 Vent/drain plug 58 U - Bolt M8 4 Holes 9 dia. Cable gland (option) see note “C“ Conduit conn. ø80 Detail “A“ (press conn.) ø18.5 H 2.5 DETAIL “B“ (Conduit conn.) ø 15 Detail “C“ ø13 Oval flange screw see table1 1 252 41.3 8 F 2-M8 × 12 Side vent (option) ø7 D see table 1 See table 1 G 1/2 27 70 120 50 4th digit code S Conduit conn. D E G1/2 Press. conn. H Rc1/4 1/4–18NPT 1/4–18NPT 1/4–18NPT 1/4–18NPT Oval flange screw 7/16-20UNF Screw depth13 7/16-20UNF Screw depth13 M10 Screw depth13 7M10 Screw depth13 7/16-20UNF Screw depth13 Earth terminal M4 No. 8-32UNC M4 M4 M4 F 17 8 CONNECTION DIAGRAM + – CK+ CK– T V W 1/2 16 5 –14NPT Pg13.5 8 4.5 M20 × 1.5 16 5 Pg13.5 8 4.5 +– X Table 1 Note1) : Cable gland is supplied in case of flamproof packing type. ø11 cable is suitable. E S H GT 0 F V K W X V H3 M T 17 7 FHG, FKG...3 Fastener (In case of 10th digit code “B,C,M,N“) Zero/span ADJ. screw In case of 4th digit code “S,V,W,X“ U - Bolt M8 Mtg.pipe JIS 50A (2") 43.5 Up Ø80 104 110 Down 88 50 38 40 234 58 4 Holes 9 dia “C“ Conduit conn. With field ind (option) 51 71 (27) Cable gland (option) note see “D“ Conduit conn. Detail “A“ (Press. conn.“) 4th digit code “S“ Ø16 Detail “B“ 4th digit code “T,V,W,X“ Ø16 1/4-18NPT Detail “C“ (Conduit conn.) Earth terminal (both side) see table 1 Ø80 2 -0.1 Ø12 +0.2 +0.1 1 0 Ø 15 10 70 Ø4 E Ø4 See table 1 Detail “D“ Ø 13 262 P “A“ or “B“ press conn. View from P 41.3 2-M8 × 12 Oval fgange screw see table 1 50 36.5 70 120 4th digit coode S 98 G 1/2 Oval fgange screw see table 1 Conduit conn. E G1/2 1/2 -14NPT Pg13.5 M20 × 1.5 Pg13.5 F 17 16 8 16 8 H 8 5 4.5 5 4.5 Oval flange screw 7/16–20UNF Screw depth 13 7/16–20UNF Screw depth 13 M10 Screw depth 13 M10 Screw depth 13 7/16–20UNF Screw depth 13 Earth terminal M4 No. 8-32UNC M4 M4 M4 CONNECTION DIAGRAM + – CK+ CK– T +– S H GT F V K W X B L3 U V W X Table 1 Note) : Cable gland is supplied in case of flameproof packing type. ø11 cable is suitable. Head office 11-2 Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032 Japan Phone: 81-3-5435-7111 http://www.fujielectric.co.jp/eng/sg/KEISOKU/welcome.htm Sales Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187, 6189 Information in this catalog is subject to change without notice. 17 Printed in Japan F H
EDSX5-73 价格&库存

很抱歉,暂时无法提供与“EDSX5-73”相匹配的价格&库存,您可以联系我们找货

免费人工找货