0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AOM-2SF

AOM-2SF

  • 厂商:

    GAMEWELL-FCI

  • 封装:

  • 描述:

    AOM-2SF - Addressable output supervised control module - Gamewell-FCI by Honeywell

  • 数据手册
  • 价格&库存
AOM-2SF 数据手册
Velociti® Series AOM-2SF Description The Gamewell-FCI Velociti® Series addressable output supervised control module (AOM-2SF) allows an Gamewell-FCI analog addressable fire alarm control to switch an external power supply, such as a DC supply or audio amplifier (up to 80 VRMS) to notification appliances. The AOM-2SF notification appliance circuit can be wired either Class A (Style Z) or Class B (Style Y). It also supervises the wiring to the connected loads and reports their status to the panel as NORMAL, OPEN or SHORT CIRCUIT. The module contains a panel controlled LED. • Addressable Output Relay Supervised Control Module The Velociti® Series use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The module is UL Listed as suitable for releasing device service and FM Approved for deluge and preaction service. Refer to the Gamewell-FCI Compatibility Addendum, P/N 9000-0427, for a list of approved, compatible solenoids. The AOM-2SF module is designed for installation in the signaling line circuit of any Gamewell-FCI analog addressable control panel. The signaling line circuits of Gamewell-FCI analog addressable control panels are designed to accommodate up to 159 modules per circuit. The AOM-2SF is designed to mount in a 4” (10.16 cm) square junction box 2 1/8” (5.5 cm) deep. AOM-2SF Features • Compact Size allows easy installation • Class A, Style Z, or Class B, Style Y notification appliance circuit • Will accommodate audio amplifiers up to 80 VRMS • Listed as suitable for releasing device service • Bicolor LEDS flash green whenever the module is addressed, and lights steady red on alarm* *Note: Only the red LED is operative in panels that do not operate in Velociti® mode. Specifications Supervisory Current: .000375 amps. Alarm Current: .0065 amps. Operating Temperature: 32° to 120° F (0° to 49° C) Relative Humidity: 10 to 93% relative humidity (non-condensing) Dimensions: 4 1/2” H x 4” W x 1 1/4” D (11.4 H x 10.2 W x 3.2 D cm) Relay Contact Ratings Current Rating 3A 2A 0.9A 0.5A 0.5A 1A 0.5A 0.7A Maximum Voltage 30 VDC 30 VDC 110 VDC 125 VAC 30 VDC 30 VDC 125 VAC 75 VAC Load Application Description Resistive Non-Coded Resistive Coded Resistive Non-Coded Resistive Non-Coded Inductive (L/R=5ms) Coded Inductive (L/R=2ms) Coded Inductive (PF=.35) Non-Coded Inductive Non-Coded Ordering Information Model AOM-2SF Description Addressable output supervised control module An ISO 9001-2000 Company SIGNALING Velociti® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. S1949 FM APPROVED Approved 3023594 227-03-E Vol.IV 07300-0694:178 MEA Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. www.gamewell-fci.com 9020-0627 Rev. C2 page 1 of 1 ©2008 Honeywell International Inc. All rights reserved. 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 GAMEWELL-FCI
AOM-2SF 价格&库存

很抱歉,暂时无法提供与“AOM-2SF”相匹配的价格&库存,您可以联系我们找货

免费人工找货