0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HAS50-D120I

HAS50-D120I

  • 厂商:

    HITRON

  • 封装:

  • 描述:

    HAS50-D120I - CHASSIS-MOUNT UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR POWER SUPPLIES 50 WATTS DUAL ...

  • 数据手册
  • 价格&库存
HAS50-D120I 数据手册
H HiTRON CHASSIS-MOUNT UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR POWER SUPPLIES 50 WATTS DUAL & TRIPLE OUTPUT HAS50-D & HAS50-T SERIES FEATURES: CHASSIS-MOUNT AC/DC MODULAR POWER SUPPLIES UNIVERSAL AC INPUT RANGE MEET UNIVERSAL SAFETY STANDARDS EMI MEETS CISPR PUB.22/FCC CLASS B CE MARKING COMPLIANCE SPECIFICATION INPUT SPECIFICATION Input Voltage: 90-264Vac typical. Nominal: 115/230Vac. Input Frequency: 47-63 Hz. (Nominal 50/60Hz.). Input Current: 0.76A @115Vac./0.39A @230Vac typical. Inrush Current: 4.8A(rms) or 34A(peak)@230Vac typical. Input Fuse: Use internal fuse. Dielectric Withstand: Meet IEC60950. 3,000Vac-Output/Input. 1,500Vac-Input/GND. 500Vac-Output/GND. EMI: Meet CISPR PUB. 22/FCC Class B. Hold-up time: 18 mS @115Vac, 82mS @230Vac typical. Earth Leakage: Less than 0.46mA @230Vac. Remote ON/OFF: ON(Enable)=Open. OFF(Disable)=Short. OUTPUT SPECIFICATION Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Wattage: 50 Watts typical. Line Regulation: Various with output voltage. ±0.1-0.5% typical. Load Regulation: Various with output voltage. Main VO1 ± 1-2% typical. Aux.VO2 ± 3-5% typical. (stacked on) Aux.VO3 ± 2-3% typical. (P.R.) Noise & ripple: 1.0% typical peak to peak. OVP: Built-in on main output VO1. Adjustability: Available at main output VO1. Overload Protection (OLP): Fully protected against output overload and short circuit. Typical 125-150% of rating output load. Con2sult the factory for special OLP setting. Operating Temperature: -10°C to +75°C range. –10°C to +50°C @ full load without derating. From+50°C derating linearly to half load @+75°C (Refer to the Derating Chart). GENERAL SPECIFICATION Efficiency: 78-83% typical various with output voltage. Switching Frequency: 68K Hz. Circuit Topology: Fixed Frequency Flyback circuit. Transient Response: Peak deviation on 200-220mV, Recovery time +50°C in a confined area. Commercial Grade only. NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified. (2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load. In application Due to requests in market and advances in technology, specifications subject to change without notice. -15- OUTPUT VOLTAGE/ CURRENT RATINGS CHART DUAL OUTPUT MODEL NO. HAS50-D050E HAS50-D050I HAS50-D120I HAS50-D150K HAS50-D033E VO1 ★@ TYP. VOLT. 3.0A +5V 3.5A +5V 2.0A +12V 1.7A +15V 3.5A +3.3V TYP 3.0A 2.0A 2.0A 1.7A 3.0A VO2● VOLT. -5V +12V -12V -15V -5V TRIPLE OUTPUT MODEL NO. HAS50-T033EE HAS50-T033II HAS50-T033KK HAS50-T050II HAS50-T050KK HAS50-T050IE HAS50-T050MI VO1 @ TYP. 4.0A 4.0A 4.0A 3.5A 3.5A 3.5A 3.5A ★ VOLT. +3.3V +3.3V +3.3V +5.0V +5.0V +5.0V +5.0V VO3 ● VO2 † TYP. VOLT. VOLT. 0.5A +5V -5V 0.5A +12V -12V 0.5A +15V -15V 0.5A +12V -12V 0.5A +15V -15V 0.5A +12V -5V 0.5A +24V -12V "†" Stacked on main O/P. "●" Installed with Post Regulator (P.R.). TYP. 2.0A 1.0A 0.8A 1.0A 0.8A 1.0A 0.5A Symbols: "★" OVP built-in. "@" Adjustable. Note: (1) Max. (maximum load) is the continuous operating load of each rail, but the max. load of each rail can not be drawn from all outputs at the same time. (2) Peak output, less than 60 Sec. with duty cycle
HAS50-D120I 价格&库存

很抱歉,暂时无法提供与“HAS50-D120I”相匹配的价格&库存,您可以联系我们找货

免费人工找货