H HiTRON
2007/09/18
CHASSIS-MOUNT UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR POWER SUPPLIES 50 WATTS SINGLE OUTPUT HAS50S SERIES
FEATURES:
CHASSIS-MOUNT AC/DC MODULAR POWER SUPPLIES UNIVERSAL AC INPUT RANGE COMPACT IN SIZE MEET UNIVERSAL SAFETY STANDARDS EMI MEET CISPR PUB.22 / FCC CLASS B CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: 90-264Vac typical. Nominal: 115/230Vac. Input Frequency: 47-63 Hz. (Nominal 50/60 Hz.) Input Current: 0.77A @115Vac./0.39A @230Vac. Inrush Current: 34A(peak) or 4.8(rms)@230Vac typical. Input Fuse: Use internal fuse. Dielectric Withstand: Meet IEC950. 3,000Vac-Output/Input. 1,500Vac-Input/GND. 500Vac-Output/GND. EMI: Meet CISPR PUB.22 / FCC Class B. Hold-up time: 19 mS @115Vac, 80mS @230Vac typical. Earth Leakage: Less than 0.52mA @230Vac. Remote On/Off: ON(Enable)=Open. OFF(Disable)=Short.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart. Output Current: See Ratings Chart Output Wattage: 50 Watts typical. Line Regulation: Various with output voltage. 0.1-0.5% typical. Load Regulation: Various with output voltage. ±1.0-2.0% typical. Noise & ripple: 1.0% typical peak to peak. OVP: Built-in on main output. Adjustability: Available at main output. Overload Protection (OLP): Fully protected against output overload and short circuit. Typical 120-150% max. load. Consult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency: 72%-85% typical various with output voltage. Switching Frequency: 63K Hz. Circuit Topology: Fixed Frequency Flyback circuit. Transient Response: Peak deviation 200mV, Recovery time