0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CDEUX400030A4-S-L

CDEUX400030A4-S-L

  • 厂商:

    MACOM

  • 封装:

  • 描述:

    CDEUX400030A4-S-L - CDEUX Series - Extended Range Buffer Networks (Capacitive Input) - Tyco Electron...

  • 数据手册
  • 价格&库存
CDEUX400030A4-S-L 数据手册
Corcom Facility EMI Filters Product Guide Catalog: 1654986 Issue Date: 11.2009 CDEUX Series - Extended Range Buffer Networks (Capacitive Input) CDEUX Series Filter Cabinet • Modified NEMA I, constructed of not less than #14 gauge CRS with galvanized bulkhead • Blue epoxy finish to all non-conductive surfaces • R.F. Radiation of the shielded (load) compartment greater than 100 dB from 14 kHz to 10 GHz • Front cover access, dual cover design • Filter inserts pre-wired to standoffs and lugs • Lifting hooks and mounting tabs • Legs for floor mount available (see page 24) 6P16 † Individual Filters • Sealed components with welded and/or soldered seams • Constructed of not less than #16 gauge steel with corrosion resistant plating • Bleeder resistor to eliminate shock hazard provided • Surge arrestors provided upon request‡ Electrical Characteristics Voltage Drop: Less than 1% @ unity power factor Overload: 140% of rated current for 15 minutes Harmonic Distortion: Less than 2% @ full rated current Dielectric Withstanding Voltage: Per MIL-PRF-15733 and UL1283 D.C. Insulation Resistance: Per MIL-STD-202, Method 302 Terminal Strength: Per MIL-STD-202, Method 211, Condition E Temperature Rise: Per MIL-PRF-15733 and UL1283 Shown with optional legs R.F. Radiation: 100 dB minimum shielding effectiveness How to Order: CDEUX 4 01000 A6 -S -L Legs Surge Arrestors (optional) Voltage/Frequency A6 - 120/208V, 60Hz B6 - 277/480V, 60Hz A4 - 120/208V, 400Hz 1 Insertion Loss: 100 dB from 14 kHz - 10 GHz per MIL-STD-220A, under load condition, using extended range buffer networks over the frequency range of 14 kHz - 20 MHz Current Rating 2 # of Filters Series Applicable Publications: Examples: MIL-PRF-15733 — Filters, radio interference MIL-STD-202 — Test methods for Components MIL-STD-220A — Test method of Insertion Loss MIL-STD-285 — Test method for Shielding Effectiveness NFPA 70-1987 — National Electric Code 486A - 1983 — Wire Connectors and Lug UL1283 — Underwriter Laboratories CDEUX401000A6-S-L = 4, 1000A CDEUX, 120/280V filters in cabinet with surge arrestors and legs CDEUX300030B6 = 3, 30A CDEUX, 277/480V filters in cabinet Note 1: Surge Arrestor for A6/A4* Models: V251BA60 Surge Arrestor for B6 Models: V481BA60 Current configuration listed as 5 digits with leading zeros Note 2: ‡ Not intended for HEMP applications. Refer to the CDEUL(225A) page 14 for HEMP applications.. † 60 Hz Models Only 10 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: Corcom Prods: 1-800-468-2023 1-847-680-7400 www.tycoelectronics.com www.corcom.com Corcom Facility EMI Filters Product Guide Catalog: 1654986 Issue Date: 11.2009 CDEUX Series - Extended Range Buffer Networks (Capacitive Input) Mounting Brackets E A C Removable Cover RF Gasket 2 Removable Individual Phase Filters Corcom Facility EMI Filters — NEMA Cabinet Style D B Removable Cover Area for Conduit Penetration Current (Amps) 2 x 10 3 x 10 4 x 10 2 x 30 3 x 30 4 x 30 2 x 60 & 100 3 x 60 & 100 4 x 60 & 100 2 x 150 3 x 150 4 x 150 Dimensions B C D 30.0 6.0 22.0 762.0 152.4 558.8 30.0 6.0 22.0 762.0 152.4 558.8 30.0 6.0 22.0 762.0 152.4 558.8 38.0 8.0 26.0 965.2 203.2 660.4 38.0 8.0 26.0 965.2 203.2 660.4 38.0 8.0 26.0 965.2 203.2 660.4 44.0 10.0 32.0 1117.6 254.0 812.8 44.0 10.0 32.0 1117.6 254.0 812.8 44.0 10.0 32.0 1117.6 254.0 812.8 54.0 14.0 42.0 1371.6 355.6 1066.8 54.0 14.0 42.0 1371.6 355.6 1066.8 54.0 14.0 42.0 1371.6 355.6 1066.8 Weight E (Pounds/KG) 16.0 95 406.4 43.1 22.0 100 558.8 45.4 28.0 120 711.2 54.4 18.0 170 457.2 77.1 25.0 240 635.0 108.9 32.0 300 812.8 136.1 18.0 240 457.2 108.9 25.0 310 635.0 140.6 32.0 400 812.8 181.4 18.0 320 457.2 145.1 25.0 430 635.0 195.0 32.0 650 812.8 294.8 Current (Amps) For optional legs, refer to page 24 A 14.0 355.6 20.0 508.0 26.0 660.4 16.0 406.4 23.0 584.2 30.0 762.0 16.0 406.4 23.0 584.2 30.0 762.0 16.0 406.4 23.0 584.2 30.0 762.0 A 16.0 2 x 225 406.4 23.0 3 x 225 584.2 30.0 4 x 225 762.0 22.0 2 x 400 558.8 30.0 3 x 400 762.0 38.0 4 x 400 965.2 38.0 2 x 800 965.2 56.0 3 x 800 1422.4 72.0 4 x 800 1828.8 56.0 2 x 1000 & 1200 1422.4 82.0 3 x 1000 & 1200 2082.8 4 x 1000 & 1200 106.0 2692.4 Dimensions B C D 54.0 14.0 42.0 1371.6 355.6 1066.8 54.0 14.0 42.0 1371.6 355.6 1066.8 54.0 14.0 42.0 1371.6 355.5 1066.8 64.0 26.0 61.5 1625.6 660.4 1562.1 64.0 26.0 61.5 1625.6 660.4 1562.1 64.0 26.0 61.5 1625.6 660.4 1562.1 70.0 26.0 67.5 1778.0 660.4 1714.5 70.0 26.0 67.5 1778.0 660.4 1714.5 70.0 26.0 67.5 1778.0 660.4 1714.5 70.0 26.0 67.5 1778.0 660.4 1714.5 70.0 26.0 67.5 1778.0 660.4 1714.5 70.0 26.0 67.5 1778.0 660.4 1714.5 Weight E (Pounds/KG) 18.0 380 457.2 172.4 25.0 520 635.0 235.9 32.0 700 812.8 317.5 24.0 800 609.6 362.9 32.0 1100 812.8 498.9 40.0 1400 1016.0 635.0 40.0 1400 1016.0 635.0 58.0 2100 1473.2 952.5 74.0 2600 1879.6 1179.3 58.0 2000 1473.2 907.2 84.0 3000 2133.6 1360.8 108.0 3800 2743.2 1723.6 *400Hz filters available upon request. Will require external power factor correction coil. Please contact Tyco Electronics Application Engineering 847-573-6517. Recommended torque for fasteners on removable cover: 25 in. lb. ± 3 in. lb. Max. Operating Voltage A6: 120/208V, 60 Hz B6: 277/480V, 60 Hz A4*: 120/208V, 400 Hz Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: Corcom Prods: 1-800-468-2023 1-847-680-7400 11 www.tycoelectronics.com www.corcom.com
CDEUX400030A4-S-L 价格&库存

很抱歉,暂时无法提供与“CDEUX400030A4-S-L”相匹配的价格&库存,您可以联系我们找货

免费人工找货