0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
B73-1B2D-BKQ

B73-1B2D-BKQ

  • 厂商:

    MAGNETROL

  • 封装:

  • 描述:

    B73-1B2D-BKQ - B73 & Series 75 Sealed External Cage Liquid Level Switches - Magnetrol International,...

  • 数据手册
  • 价格&库存
B73-1B2D-BKQ 数据手册
B73 & Series 75 Sealed External Cage Liquid Level Switches DESCRIPTION Sealed external cage type level switches are completely self-contained units designed for side mounting to a tank or vessel with threaded or flanged pipe connections. These units are an industry standard in petroleum refineries and chemical plants. Thousands of these switches are in daily service throughout the world. FEATURES • Carbon steel or stainless steel welded float chamber • Service pressures up to 2240 psig (154 bar) • Process temperatures up to +1000° F (+538° C) • Specific gravity ratings as low as 0.32 • Available switch styles including dry contact, hermetically sealed and pneumatic • Single or multiple switch mechanisms available • Available switch enclosures include: NEMA 1 carbon steel for pneumatics TYPE 4X/7/9 Class I, Div. 1 Groups C & D or Groups B, C & D polymer coated aluminum • 1", 11⁄2", or 2" tank connections available in either NPT, socket weld, flanged side/side or flanged side/bottom construction • Optional high temperature insulation available. See bulletin 41-106. APPLICATIONS • Accumulators • Receivers • Flare pots • Scrubbers • Oil refineries • Flash tanks • Knockout drums • Storage tanks • Separators • Chemical processing plants • Steam and electric generating stations TECHNOLOGY A permanent magnet Œ is attached to a pivoted switch actuator and adjustment screw . As the float Ž rises following the liquid level, it raises the attraction sleeve  into the field of the magnet, which then snaps against the non-magnetic enclosing tube , actuating the switch ‘. The enclosing tube provides a static pressure boundary between the switch mechanism and the process. On a falling level, an inconel spring retracts the magnet, deactivating the switch. 2 5 6 4 1 3 Pivot Return Spring Process Liquid Process Liquid Rising Level Falling Level AGENCY AGENCY APPROVALS APPROVED MODEL AREA CLASSIFICATION FM All with an electric switch mechanism and a housing listed as TYPE 4X/7/9 All with an electric switch mechanism and a housing listed as TYPE 4X/7/9 Class I, Div 1, Group B Class I, Div 1, Groups C & D Class II, Div 1, Groups E, F & G Class I, Div 1, Groups B, C & D Class II, Div 1, Groups E, F & G Class I, Div 2, Groups B, C & D Class I, Div 1, Groups C & D Class II, Div 1, Groups E, F & G Class I, Div 1, Groups B, C & D Class II, Div 1, Groups E, F & G ATEX II 2 G EEx D IIC T6 94/9/EC IEC Ex Ex d IIc T6 IP66 Installation Category II Pollution Degree 2 CSA All with a Series F, HS, H1, 8 or 9 electric switch mechanism and a housing listed as CSA TYPE 4X All with an electric switch mechanism and a housing listed as TYPE 4X/7/9 All with an electric switch mechanism and a housing listed as TYPE 4X/7/9 Class I, Div 1, Group B All with an electric switch mechanism and an ATEX housing Œ ATEX / IEC Ex  CE Œ Models with two HS or two H1 switches are not ATEX approved.  IEC Installation Instructions: The cable entry and closing devices shall be Ex d certified suitable for the conditions of use and correctly installed. For ambient temperatures above +55° C or for process temperatures above +150° C, suitable heat resistant cables shall be used. Heat extensions (between process connection and housing) shall never be insulated. Special conditions for safe use: When the equipment is installed in process temperatures higher than +85° C the temperature classification must be reduced according to the following table as per IEC60079-0. Maximum Process Temperature < 85° C < 100° C < 135° C < 200° C < 300° C < 450° C Temperature Classification T6 T5 T4 T3 T2 T1 Low Voltage Directives 2006/95/EC Per Harmonized Standard: EN 61010-1/1993 & Amendment No. 1 BASIC ELECTRICAL RATINGS Voltage B Switch Series and Non-Inductive Ampere Rating R 8 9 C D F HS H1 — 15.00 10.00 0.25 5.00 1.00 1.00 1.00 — — 15.00 — — 5.00 1.00 1.00 10.00 10.00 4.00 5.00 1.00 1.00 3.00 0.50 — — 1.00 10.00 0.30 0.50 0.40 0.40 — — — 0.50 3.00 — 0.25 — These units are in conformity with IECEx KEM 05.0020X Classification Ex d IIC T6 Tambient -40° C to +70° C 120 VAC 15.00 240 VAC 15.00 24 VDC 6.00 120 VDC 0.50 240 VDC 0.25 DIMENSIONAL Œ Min. SG B75 0.67 SPECIFICATIONS MILLIMETERS NPT & Socket Weld A B C 227 107 1.93 2.61 665 612 689 612 689 375 338 395 338 395 233 760 391 208 705 355 233 778 412 208 705 355 233 778 412 233 208 233 208 233 775 722 56 795 722 306 44 44 45 n/a 195 208 706 725 49 43 74 60 64 63 n/a 68 66 586 Flanged Upper Side/Btm A B C 319 Flanged Side/Side A B C 195 694 49 27 40 244 121 2.23 2.95 66 42 57 Actuating Levels  HL LL 49 195 678 336 66 CARBON STEEL CHAMBERS WITH 11⁄2-INCH CONNECTIONS INCHES NPT & Socket Weld A B C Flanged Upper Side/Btm A B C Flanged Side/Side A B C Actuating Levels HL LL 1.93 2.61 8.94 4.22 23.06 12.56 7.69 26.69 13.21 7.69 27.34 C75 0.55 F75 0.55 11.06 5.75 26.19 14.78 9.19 29.92 15.39 9.19 30.53 1.08 1.66 281 146 G75 0.53 9.62 4.75 24.09 13.31 8.19 27.75 13.96 8.19 28.42 J75 0.48 1.59 2.25 K75 0.39 12.06 5.75 27.14 15.56 9.19 30.64 16.21 9.19 31.29 1.77 2.39 306 146 L75 0.40 9.62 4.75 24.09 13.31 8.19 27.75 13.96 8.19 28.42 1.78 2.52 244 121 N75 0.32 12.06 5.75 27.14 15.56 9.19 30.64 16.21 9.19 31.29 1.81 2.49 306 146 S75 0.60 V75 0.74 Z75 0.68 Consult Factory n/a n/a Consult Factory 589 612 319 338 195 684 336 208 708 355 8.82 4.22 23.20 12.56 7.68 26.94 13.21 7.68 27.79 1.94 2.69 224 107 9.51 4.75 24.09 13.31 8.18 27.89 13.96 8.18 28.54 1.69 2.59 242 121 Levels are ±0.25" (6 mm) 2 CARBON STEEL CHAMBERS WITH 2-INCH CONNECTIONS INCHES Min. Œ SG B75 0.67 8.69 4.34 23.20 12.56 7.69 26.07 13.21 7.69 27.72 C75 0.55 1.64 2.36 NPT & Socket Weld A B C Flanged Upper Side/Btm A B C Flanged Side/Side A B C Actuating Levels HL LL 1.48 2.16 MILLIMETERS NPT & Socket Weld A B C 221 110 589 669 615 694 615 694 Flanged Upper Side/Btm A B C 319 375 338 395 338 395 Flanged Side/Side A B C 195 233 208 233 208 233 704 41 233 766 391 208 712 355 233 786 412 208 712 355 233 786 412 782 728 49 802 728 802 40 38 40 n/a 195 208 711 732 48 37 67 56 56 58 n/a 67 57 19 33 241 124 59 34 50 Actuating Levels  HL LL 37 195 662 336 54 F75 0.55 10.94 5.88 26.32 14.78 9.19 30.16 15.39 9.19 30.77 0.78 1.36 278 149 G75 0.53 9.50 4.88 24.21 13.31 8.19 28.02 13.96 8.19 28.67 J75 0.48 1.95 2.67 1.31 1.97 K75 0.39 11.94 5.88 27.32 15.56 9.19 30.94 16.21 9.19 31.59 1.59 2.21 303 149 L75 0.40 9.50 4.88 24.21 13.31 8.19 28.02 13.96 8.19 28.67 1.50 2.24 241 124 N75 0.32 11.94 5.88 27.32 15.56 9.19 30.94 16.21 9.19 31.59 1.63 2.31 303 149 S75 0.60 V75 0.74 Z75 0.68 Consult Factory n/a n/a Consult Factory 591 614 319 338 195 694 336 208 715 355 8.49 4.34 23.27 12.56 7.68 27.34 13.21 7.68 27.99 1.88 2.63 216 110 9.31 4.87 24.16 13.31 8.18 28.16 13.96 8.18 28.81 1.44 2.25 236 124 Housing NEMA 1 TYPE 4X/7/9 Group B D E Conduit Connections F Electrical Switches TYPE 4X/7/9: 1" NPT Group B: 1" NPT Pneumatic Switches 1 NEMA 1: ⁄4" NPT 4.70 5.00 (119) (127) 5.93 (151) 3.87 (98) Œ Min S.G. given is for single switch units with –1 materials of construction only. Consult factory for other configurations. Levels are ±0.25" (6 mm)  Switch actuating levels (HL & LL) are given for minimum specific gravity materials of construction –1 and single switch units. Consult factory for other configurations. NOTES: 1. Standard process connections are a combination of 1" NPT and 1" socket weld coupling. 2. Allow overhead clearance of 10 inches (254 mm) for cover removal. 3. All housings rotatable 360 degrees. D D E D E E F F F C HL C HL LL A A LL C HL LL A B B B Series 75 Threaded and Socket Weld Upper Side/Bottom Series 75 Flanged Upper Side/Bottom Series 75 Flanged Side/Side 3 DIMENSIONAL SPECIFICATIONS MILLIMETERS NPT & Socket Weld A B C 84 92 92 69 66 76 442 560 586 555 548 557 Flanged Upper Side/Btm A B C 235 294 313 294 294 294 159 170 170 144 141 155 Flanged Side/Side A B C Actuating Levels  HL LL 30 70 74 62 62 65 53 92 96 89 89 89 STAINLESS STEEL CHAMBERS WITH 1-INCH CONNECTIONS INCHES Min.Œ SG B73 C75 J75 NPT & Socket Weld A B C Flanged Upper Side/Btm A B C Flanged Side/Side A B C Actuating Levels HL LL 0.59 6.36 3.34 17.44 9.25 6.25 20.32 9.90 6.25 21.00 1.22 2.10 151 0.60 8.50 3.61 22.06 11.56 6.68 25.12 12.21 6.68 25.75 2.75 3.62 216 0.57 9.25 3.61 23.06 12.31 6.68 26.12 12.96 6.68 26.75 2.93 3.78 235 515 251 159 532 638 310 170 654 663 329 170 679 633 310 144 651 625 310 141 646 635 310 155 652 O75 Ž 0.85 8.50 2.71 21.87 11.56 5.68 24.93 12.21 5.68 25.62 2.44 3.50 216 O75  0.85 8.50 2.59 21.56 11.56 5.56 24.62 12.21 5.56 25.43 2.44 3.50 216 P75 0.75 8.50 3.09 21.93 11.56 6.12 25.00 12.21 6.12 25.68 2.56 3.50 216 Levels are ±0.25" (6 mm) CARBON STEEL CHAMBERS WITH 1-INCH CONNECTIONS INCHES Min.Œ SG B73 0.59 B75 0.67 8.69 3.80 22.69 11.56 6.69 25.56 12.21 6.69 26.21 C75 0.55 2.72 3.44 NPT & Socket Weld A B C 6.36 3.34 17.44 Flanged Upper Side/Btm A B C A Flanged Side/Side B C Actuating Levels  HL LL MILLIMETERS NPT & Socket Weld A B C Flanged Upper Side/Btm A B C 515 649 706 668 754 668 754 Flanged Side/Side A B C 251 159 532 310 170 666 69 366 208 721 329 183 685 73 386 208 742 329 183 685 386 208 742 54 62 55 54 69 60 91 70 81 72 70 86 81 44 57 240 110 595 313 183 87 59 74 Actuating Levels  HL 30 65 221 97 576 294 170 LL 53 82 9.25 6.25 20.32 9.90 6.25 21.00 1.22 2.10 151 2.56 3.24 84 442 235 159 F75 0.55 10.91 5.33 24.91 13.78 8.19 27.78 14.39 8.19 28.39 1.76 2.35 277 135 633 350 208 G75 0.53 9.44 4.33 23.44 12.31 7.19 26.31 12.96 7.19 26.96 J75 0.48 2.90 3.62 2.25 2.92 K75 0.39 11.69 5.33 25.69 14.56 8.19 28.56 15.21 8.19 29.21 2.15 2.77 297 135 653 370 208 L75 0.40 9.44 4.33 23.44 12.31 7.19 26.31 12.96 7.19 26.96 2.45 3.19 240 110 595 313 183 N75 0.32 11.69 5.33 25.69 14.56 8.19 28.56 15.21 8.19 29.21 2.17 2.86 297 135 653 370 208 S75 0.60 11.16 5.33 27.06 V75 0.74 Z75 0.68 Consult Factory 2.13 2.78 283 135 687 Consult Factory 656 678 313 170 672 329 182 695 9.02 4.15 23.27 11.56 6.68 25.81 12.21 6.68 26.46 2.63 3.38 229 105 591 294 170 9.77 4.68 24.16 12.31 7.18 26.70 12.96 7.18 27.35 2.38 3.19 248 119 614 313 182 Levels are ±0.25" (6 mm) Housing NEMA 1 TYPE 4X/7/9 Group B D E Conduit Connections F Electrical Switches TYPE 4X/7/9: 1" NPT Group B: 1" NPT Pneumatic Switches 1 NEMA 1: ⁄4" NPT 4.70 5.00 (119) (127) 5.93 (151) 3.87 (98)  Switch actuating levels (HL & LL) are given for minimum specific gravity materials of construction –1 and single switch units. Consult factory for other configurations.  316 Stainless steel only. Ž 304 Stainless steel only. Œ Min S.G. given is for single switch units with –1 materials of construction only. Consult factory for other configurations.  These dimensions increase by 2.19 inches (55 mm) with Series HS switches with terminal blocks. NOTES: 1. Standard process connections are a combination of 1" NPT and 1" socket weld coupling. 2. Allow overhead clearance of 10 inches (254 mm) for cover removal. 3. All housings rotatable 360 degrees. 4 DIMENSIONAL INCHES (mm) SPECIFICATIONS D E D E D E F F F C HL C HL LL A A A LL C HL LL B B B Series 75 Threaded and Socket Weld Upper Side/Bottom Series 75 Flanged Upper Side/Bottom Series 75 Flanged Side/Side D E D E E D 6.25 ➃ (158) F 6.25 ➃ (158) F F plugged 6.25 ➃ (158) F F plugged ➄ C ➄ C ➄ C F plugged HL HL LL LL HL LL A A A B B B Model B73 Threaded and Socket Weld Upper Side/Bottom Model B73 Flanged Upper Side/Bottom Model B73 Flanged Side/Side 5 MODEL SERIES NUMBER Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP) B73 MODEL NUMBER CODE Model No. B73-1 B73-2 B73-3 B73-4 Min. SG 0.59 0.59 0.59 0.59 Pressure Rating psig @ ° F bar @ ° C Œ 100 450 38 232 Œ Materials of Construction Carbon steel chamber, 316 stainless steel float, 400 stainless steel trim Carbon steel chamber, 316 stainless steel float, 316 stainless steel trim 304 stainless steel chamber, 316 stainless steel float, 304 stainless steel trim 316 stainless steel chamber, 316 stainless steel float, 316 stainless steel trim 400 275 28 20 TANK CONNECTION TYPE AND SIZE B20 B30 N30 N40 S30 S40 1" NPT threaded side/bottom 1" socket weld side/bottom 1" 150 lb. flanged upper side/bottom 1" 300 lb. flanged upper side/bottom 1" 150 lb. flanged side/side 1" 300 lb. flanged side/side Œ Models are limited to maximum temperature rating of selected switch mechanism. See Switch Mechanism chart on page 9.  Process temperature based on +100° F (+38° C) ambient. Ž On steam & other condensing applications, temperature downrated to +400° F (+204° C) process @ +100° F (+38° C) ambient. 6 ELECTRIC SWITCH MECHANISM AND ENCLOSURE Model B73-1 Only  Process Temperature Range °F (°C) -40 to +250 (-40 to +121) -40 to +450 (-40 to +232) -40 to +250 (-40 to +121) Models B73-2, B73-3, B74-4 TYPE 4X/7/9 Aluminum Enclosure Class I, Div 1 Class I, Div 1 Groups Groups C&D B, C & D BKP BNP CKP CNP BKT BNT CKT CNT n/a Class I, Div 1 Class I, Div 1 Groups Groups C&D B, C & D BKQ BNQ CKQ CNQ DKQ DNQ FAC FKQ BKS BNS CKS CNS DKS DNS FKS Switch Description One Set Point Contacts SPDT DPDT SPDT DPDT SPDT DPDT SPDT ATEX BAC BBC CAC CBC ATEX BA9 BB9 CA9 CB9 DA9 DB9 FA9 Series B Snap Series C Snap Series D Snap FKP FKT Series F Hermetically Sealed Snap -50 to +450 (-46 to +232) DPDT Ž -50 to +450 (-46 to +232) FNP FNT FBC FNQ FNS FB9 Series HS Hermetically Sealed 5 amp Snap with wiring leads SPDT n/a HMC HEK n/a DPDT Ž -50 to +450 (-46 to +232) n/a HMF HET n/a Series HS Hermetically Sealed 5 amp Snap with terminal block SPDT n/a HM3 HM4 HA9 DPDT n/a HM7 HM8 HB9 PNEUMATIC SWITCH MECHANISM AND ENCLOSURE Switch Description Series J Bleed Type Series K Non-Bleed Maximum Supply Pressure psig bar 100 60 60 100 40 7 4 4 7 3 Maximum Process Temperature °F °C 400 400 450 400 400 204 204 232 204 204 Bleed Orifice Diameter inches mm .063 .094 .055 — — 1.6 2.3 1.4 — — Models with Material of Construction Code 1 Code 2, 3 or 4 NEMA 1 NEMA 1 JDG JEG JFG — KOG JDE JEE JFE KOE — 7 MODEL SERIES 75 NUMBER with Carbon Steel Chamber Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP) Pressure Rating  100 1000 500 1000 750 400 600 300 450 1500 2240 2193 550 870 435 870 653 — — — — 1275 1913 1913 psig @ ° F 750 716 400 800 600 250 375 185 280 1045 1455 1425 900 Ž 357 357 523 338 — — — — 523 728 713 1000 Ž 138 138 200 130 — — — — n/a n/a n/a 38 69 34 69 52 28 41 21 31 103 154 151 288 60 30 60 45 — — — — 88 132 132 bar @ ° C 399 49 28 55 41 17 26 13 19 72 100 98 482 Ž 25 25 36 23 — — — — 36 50 49 538 10 10 14 9 — — — — n/a n/a n/a MODEL NUMBER CODE Min. S.G. for models with Œ Model Material of Construction Code Code 1 2 B75 0.67 0.71 C75 0.55 0.59 F75 0.55 0.56 G75 0.53 0.56 J75 0.48 0.51 K75 0.39 0.40 L75 0.40 0.42 N75 0.32 0.33 S75 0.60 n/a V75 0.74 0.81 Z75 0.68 0.71 MATERIALS OF CONSTRUCTION 1 2 Carbon steel chamber, 316 stainless steel float, 400 stainless steel trim Carbon steel chamber, 316 stainless steel float, 316 stainless steel trim TANK CONNECTION TYPE AND SIZE Size Type Threaded Side/Bottom Socket Weld Side/Bottom Material CS CS 1" B20 B20 900  150 N60 S60 11⁄2" C20 C30 Cage Mounting Flange Rating (lbs.) 300 P40 T40 600 P50 T50 900  150 P60 T60 Q30 V30 2" D20 D30 900  Q60 V60 150 Flanged Upper Side/Bottom Flanged Side/Side CS CS N30 S30 300 N40 S40 600 N50 S50 300 Q40 V40 600 Q50 V50 P30 T30 PNEUMATIC SWITCH MECHANISM AND ENCLOSURE Switch Description Series J Bleed Type Series K Non-Bleed Maximum Supply Pressure psig bar 100 60 60 100 7 4 4 7 Maximum Bleed Process Orifice Temperature Diameter °F ° C inches mm 400 400 700 400 204 204 371 204 .063 .094 .055 — 1.6 2.3 1.3 — Excluding S75, V75 & Z75 NEMA 1 JDE JEE JFE KOE S75, V75 & Z75 NEMA 1 JKE JLE JME KPE Œ Minimum specific gravity ratings apply only to single stage  Models are limited to maximum temperature rating of selected Ž Use caution when specifying carbon steel and stainless steel   ‘ ’ for temperatures greater than +800° F (+427° C), as they become sensitized. S75, V75 & Z75 contain 17-7 ph float. Valid for Models V75 & Z75 only. Process temperature based on +100° F (+38° C) ambient. HS and H1 switches can be used with only materials of construction code 1 on models S75, V75 & Z75. switch mechanism. See Switch Mechanism Charts above. units. Consult factory for two or three stage units. “ On steam and other condensing applications, temperature down-rated to +400° F (+204° C) process at +100° F (+38° C) ambient. 8 See next page for Electric Switch Mechanism and Enclosure codes. ELECTRIC SWITCH MECHANISM AND ENCLOSURE Process ‘ Temperature Set Contacts TYPE 4X/7/9 Aluminum Enclosure Range Points ATEX ATEX °F (°C) Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 Ex II 2 G EEx Ex II 2 G EEx Groups C&D Group B Groups C&D Group B d IIC T6 d IIC T6 1 BKA BKJ BCC BKB BKK BC9 SPDT 2 BLA BLJ BDC BLB BLK BD9 -40 to +250 3 BMA BMJ BEC BMB BMK BE9 (-40 to +121) 1 BNA BNJ BFC BNB BNK BF9 DPDT 2 BOA BOJ BGC BOB BOK BG9 1 CKA CKJ CCC CKB CKK CC9 SPDT 2 CLA CLJ CDC CLB CLK CD9 -40 to +450 3 CMA CMJ CEC CMB CMK CE9 (-40 to +232) 1 CNA CNJ CFC CNB CNK CF9 DPDT 2 COA COJ CGC COB COK CG9 1 DKB DKK DC9 DKB DKK DC9 SPDT 2 DLB DLK DD9 DLB DLK DD9 -40 to +250 3 DMB DMK DE9 DMB DMK DE9 (-40 to +121) 1 DNB DNK DF9 DNB DNK DF9 DPDT 2 DOB DOK DG9 DOB DOK DG9 1 FKA FKJ FCC FKB FKK FC9 SPDT 2 FLA FLJ FDC FLB FLK FD9 -50 to +750 (-46 to +399) 1 FNA FNJ FFC FNB FNK FF9 DPDT 2 FOA FOJ FGC FOB FOK FG9 1 HMJ HMK HMJ HMK SPDT 2 HMN HMP HMN HMP -50 to +550 “ N/A N/A (-46 to +288) 1 HMS HMT HMS HMT DPDT 2 HMY HMZ HMY HMZ -50 to +550 “ (-46 to +288) SPDT DPDT SPDT DPDT SPDT DPDT SPDT DPDT SPDT DPDT 1 1 1 2 1 2 1 2 1 2 3 1 2 1 2 3 1 2 HM3 HM7 HKJ HKN RKB RLB RNB ROB 8KA 8LA 8MA 8NA 8OA 9KA 9LA 9MA 9NA 9OA HM4 HM8 HKK N/A HKP RKK RLK RNK ROK 8KJ 8LJ 8MJ 8NJ 8OJ 9KJ 9LJ 9MJ 9NJ 9OJ RC9 RD9 RF9 RG9 8CC 8DC 8EC 8FC 8GC 9CC 9DC 9EC 9FC 9GC HKN RKB RLB RNB ROB 8KB 8LB 8MB 8NB 8OB 9KB 9LB 9MB 9NB 9OB HKP RKK RLK RNK ROK 8KK 8LK 8MK 8NK 8OK 9KK 9LK 9MK 9NK 9OK RC9 RD9 RF9 RG9 8C9 8D9 8E9 8F9 8G9 9C9 9D9 9E9 9F9 9G9 HA9 HB9 HM3 HM7 HKJ HM4 HM8 HKK N/A HA9 HB9 All Models with Material of Construction Code 1 except Models S75, V75 & Z75 All models with Material of Construction Codes 2 and all Models S75, V75 & Z75 Switch Description Series B Snap Switch Series C Snap Switch Series D DC Current Snap Switch Series F Hermetically Sealed Snap Switch Series HS ’ Hermetically Sealed 5-amp Snap Switch with Wiring Leads Series HS ’ Hermetically Sealed 5-amp Snap Switch with Terminal Block Series H1 ’ Hermetically Sealed 1-amp Snap Switch with Wiring Leads Series R High Temperature Snap Switch -50 to +750 (-46 to +399) -40 to +750 (-40 to +399) Series 8 Hermetically Sealed Snap Switch -50 to +750 (-46 to +399) Series 9 High Temperature Hermetically Sealed Snap Switch Switch Description Series R High Temperature Snap Switch Series 9 High Temperature Hermetically Sealed Snap Switch -50 to +750 (-46 to +399) Process ‘ Cast Iron Cast Iron CS/Aluminum CS/Aluminum Set Temp. Range Contacts Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 Points NEMA 4X NEMA 4X °F (°C) Groups C&D Group B Groups C&D Group B 1 R1M RKM RKW R1M RKM RKW SPDT 2 R3M RLM RLW R3M RLM RLW -40 to +1000 (-40 to +538) 1 RDM RNM RNW RDM RNM RNW DPDT 2 REM ROM ROW REM ROM ROW 1 9AD 9KD 9KV 9AM 9KM 9KW SPDT 2 9BD 9LD 9LV 9BM 9LM 9LW -50 to +1000 3 9CD 9MD 9MV 9CM 9MM 9MW (-46 to +538) 1 9DD 9ND 9NV 9DM 9NM 9NW DPDT 2 9ED 9OD 9OV 9EM 9OM 9OW 9 MODEL SERIES 75 NUMBER with Stainless Steel Chamber MODEL NUMBER CODE Min. S.G. for models with Œ Model Material of Construction Code Code 3&4 C75 0.60 J75 0.57 O75 0.85 P75 0.75 Pressure Rating  100 500 400 500 400 550 435 — 435 — psig @ ° F 750 900 Ž 400 385 225 — 400 385 225 — 1000 Ž 380 — 380 — 38 34 28 34 28 288 30 — 30 — bar @ ° C 399 28 16 28 16 482 Ž 26 — 26 — 538 Ž 26 — 26 — MATERIALS OF CONSTRUCTION 3 4 304 Stainless steel chamber, 316 stainless steel float, 316 stainless steel trim 316 Stainless steel chamber, 316 stainless steel float, 316 stainless steel trim TANK CONNECTION TYPE AND SIZE Size Type Threaded Side/Bottom Socket Weld Side/Bottom Material SS SS 1" B20 B30 11⁄2"  2"  D20 D30 C20 C30 Cage Mounting Flange Rating (lbs.) 150 Flanged Upper Side/Bottom Flanged Side/Side SS SS N30 S30 300 N40 S40 600 900 150 300 600 900 150 300 600 900 Consult Factory Consult Factory PNEUMATIC SWITCH MECHANISM AND ENCLOSURE Switch Description Series J Bleed Type Series K Non-Bleed Maximum Supply Pressure psig bar 100 60 60 100 7 4 4 7 Maximum Bleed Process Orifice Temperature Diameter °F ° C inches mm 400 400 700 400 204 204 371 204 .063 .094 .055 — 1.6 2.3 1.3 — NEMA 1 JDE JEE JFE KOE Œ Minimum specific gravity ratings apply only to single stage  Models are limited to maximum temperature rating of selected Ž Use caution when specifying carbon steel and stainless steel  The O75 and P75 are not available with 1 ⁄ " and 2" process 1 2 units. Consult factory for two or three stage units. switch mechanism. See Switch Mechanism Charts above. for temperatures greater than +800° F (+427° C), as they become sensitized. connections.  Process temperature based on +100° F (+38° C) ambient. ‘ On steam and other condensing applications, temperature down-rated to +400° F (+204° C) process at +100° F (+38° C) ambient. See next page for Electric Switch Mechanism and Enclosure codes. 10 ELECTRIC SWITCH MECHANISM AND ENCLOSURE All models Process  Temperature Set Contacts TYPE 4X/7/9 Aluminum Enclosure Range Points ATEX °F (°C) Class I, Div 1 Class I, Div 1 Ex II 2 G EEx Groups C&D Group B d IIC T6 1 BKB BKK BC9 SPDT 2 BLB BLK BD9 -40 to +250 3 BMB BMK BE9 (-40 to +121) 1 BNB BNK BF9 DPDT 2 BOB BOK BG9 1 CKB CKK CC9 SPDT 2 CLB CLK CD9 -40 to +450 3 CMB CMK CE9 (-40 to +232) 1 CNB CNK CF9 DPDT 2 COB COK CG9 1 DKB DKK DC9 SPDT 2 DLB DLK DD9 -40 to +250 3 DMB DMK DE9 (-40 to +121) 1 DNB DNK DF9 DPDT 2 DOB DOK DG9 1 FKB FKK FC9 SPDT 2 FLB FLK FD9 -50 to +750 (-46 to +399) 1 FNB FNK FF9 DPDT 2 FOB FOK FG9 1 HMJ HMK SPDT 2 HMN HMP -50 to +550 ‘ N/A (-46 to +288) 1 HMS HMT DPDT 2 HMY HMZ -50 to +550 ‘ (-46 to +288) SPDT DPDT SPDT DPDT SPDT DPDT SPDT DPDT SPDT DPDT 1 1 1 2 1 2 1 2 1 2 3 1 2 1 2 3 1 2 HM3 HM7 HKJ HKN RKB RLB RNB ROB 8KB 8LB 8MB 8NB 8OB 9KB 9LB 9MB 9NB 9OB HM4 HM8 HKK N/A HKP RKK RLK RNK ROK 8KK 8LK 8MK 8NK 8OK 9KK 9LK 9MK 9NK 9OK RC9 RD9 RF9 RG9 8C9 8D9 8E9 8F9 8G9 9C9 9D9 9E9 9F9 9G9 HA9 HB9 Switch Description Series B Snap Switch Series C Snap Switch Series D DC Current Snap Switch Series F Hermetically Sealed Snap Switch Series HS Hermetically Sealed 5-amp Snap Switch with Wiring Leads Series HS Hermetically Sealed 5-amp Snap Switch with Terminal Block Series H1 Hermetically Sealed 1-amp Snap Switch with Wiring Leads Series R High Temperature Snap Switch -50 to +750 (-46 to +399) -40 to +750 (-40 to +399) Series 8 Hermetically Sealed Snap Switch -50 to +750 (-46 to +399) Series 9 High Temperature Hermetically Sealed Snap Switch Switch Description Series R High Temperature Snap Switch Series 9 High Temperature Hermetically Sealed Snap Switch -50 to +750 (-46 to +399) Process  Cast Iron CS/Aluminum Set Temp. Range Contacts Class I, Div 1 Class I, Div 1 Points NEMA 4X °F (°C) Groups C&D Group B 1 R1M RKM RKW SPDT 2 R3M RLM RLW -40 to +1000 (-40 to +538) 1 RDM RNM RNW DPDT 2 REM ROM ROW 1 9AM 9KM 9KW SPDT 2 9BM 9LM 9LW -50 to +1000 3 9CM 9MM 9MW (-46 to +538) 1 9DM 9NM 9NW DPDT 2 9EM 9OM 9OW 11 QUALITY The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. Magnetrol is committed to providing full customer satisfaction both in quality products and quality service. Magnetrol’s quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product/service quality available. ESP Expedite Ship Plan Several Sealed External Cage Level Switches are available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP). To take advantage of ESP, match the color coded model number codes in the selection charts (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options. WARRANTY All Magnetrol mechanical level and flow controls are warranted free of defects in materials or workmanship for five full years from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Magnetrol will repair or replace the control at no cost to the purchaser (or owner) other than transportation. Magnetrol shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol products. 5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com 145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306 Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93 Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317 Copyright © 2010 Magnetrol International, Incorporated. All rights reserved. Printed in the USA. Performance specifications are effective with date of issue and are subject to change without notice. Magnetrol & Magnetrol logotype are registered trademarks of Magnetrol International. BULLETIN: 46-115.23 EFFECTIVE: August 2010 SUPERSEDES: July 2008
B73-1B2D-BKQ 价格&库存

很抱歉,暂时无法提供与“B73-1B2D-BKQ”相匹配的价格&库存,您可以联系我们找货

免费人工找货