0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NID100-5

NID100-5

  • 厂商:

    MEANWELL(明纬)

  • 封装:

    SIP13 模块

  • 描述:

    非隔离 PoL 模块 直流转换器 1 输出 5V 11A 10.5V - 53V 输入

  • 数据手册
  • 价格&库存
NID100-5 数据手册
100W DC-DC Non-Isolated Regulated Converter NID100 series ■ Features : Economical open frame design Wide input range High efficiency up to 97% Remote ON / OFF control Compact size 2.0"×1.082"× 0.472"(SIP package) Protections: Short circuit / Overload / Over voltage -30~+85℃ wide working temperature Cooling by free air convection Comply to BS EN/EN55032 ClassA without additional components Trimming output (optional) 3 years warranty ■ GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx SPECIFICATION ORDER NO. TPTC004 NID100-5 NID100-12 NID100-15 NID100-24 DC VOLTAGE RATED CURRENT 5V 11A 12V 7.5A 15V 6.5A 24V 4. 2A RATED POWER 55W 90W 97.5W 100.8W 120mVp-p 150mVp-p 200mVp-p RIPPLE & NOISE (max.) Note.2 100mVp-p OUTPUT LINE REGULATION Note.3 ±0.5% ±0.5% ±0.5% ±0.5% LOAD REGULATION Note.4 ±0.5% ±0.5% ±0.5% ±0.5% ±2.0% ±2.0% ±2.0% ±2.0% VOLTAGE TOLERANCE SWITCHING FREQUENCY (Typ.) 200KHz EXTERNAL CAPACITANCE LOAD (max.) 100uF/16V low ESR VOLTAGE RANGE NORMAL VOLTAGE INPUT 93% (12/24VDC) 24Vin EFFICIENCY (Typ.) 48Vin 92% Full load 5400mA/12VDC DC CURRENT No load 20mA PROTECTION OVERLOAD (Typ.) PROTECTION OVER VOLTAGE SHORT CIRCUIT FUNCTION ENVIRONMENT 10.5 ~ 53VDC 24VDC (or 48VDC) REMOTE CONTROL 47uf/50V low ESR 20 ~ 53VDC 30 ~ 53VDC 24VDC (or 48VDC) 24VDC (or 48VDC) 96% 95% 97% 48VDC ------ 95% 4500mA/24VDC 30mA 96% 2300mA/48VDC 4600mA/24VDC 30mA 50mA Protection type : Hiccup mode, recovers automatically after fault condition is removed 15.6~ 18V 17.5~ 21V 6.4 ~ 7.5V 28~ 33V Protection type : Shut off o/p voltage, clamp by TVS diode All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed Power on : 1.2VDC < R.C ~ com < 12VDC or open circuit ; power off : R.C ~ com < 0.4VDC or short circuit (PIN5,6,7,8 & PIN13) SAFETY STANDARDS EAC TP TC 004 approved WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. -30 ~ +85℃ (Refer to "Derating Curve") 20% ~ 85% RH non-condensing -30 ~ +105℃ TEMP. COEFFICIENT ±0.03% / ℃ (0 ~ 50℃) VIBRATION 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARD BS EN/EN62368-1(LVD) EMC EMISSION Conducted Radiated SAFETY & EMC Standard BS EN/EN55032 Class A without external components,Class B with external components Test Level / Note BS EN/EN55032 Class A without external components,Class B with external components BS EN/EN55035 Parameter EMC IMMUNITY Radiated EFT / Burst Surge Conducted MTBF DIMENSION WEIGHT NOTE 47uf/50V low ESR 20 ~ 53VDC Fuse recommended (8A) 120 ~ 300% rated output power Parameter OTHERS 68uf/25V low ESR Standard Test Level / Note BS EN/EN61000-4-3 BS EN/EN61000-4-4 Level 2, 3V/m ; criteria A BS EN/EN61000-4-5 BS EN/EN61000-4-6 17290.5K hrs min. Telcordia SR-332 (Bellcore) ; 1000.6K hrs min. 50.8*27.5*12mm or 2.0"*1.082"*0.472" inch (L*W*H) 35g;280psc/10.8Kg/0.94CUFT Level 2, 1KV ; criteria A Level 2, 1KV/Line-Line,criteria A Level 2, 3V ; criteria A MIL-HDBK-217F (25℃) 1.All parameters are specified at normal input, rated load, 25℃ 70% RH Ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Line regulation is measured from low line to high line at rated load. 4.Load regulation is measured from 10% to 100% rated load. ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:NID100-SPEC 2022-09-20 NID100 100W DC-DC Non-Isolated Regulated Converter series Connection diagram to obtain negative output voltage Note:input voltage must be < 30VDC. + Vin GND NID100 + + 6 5 4 3 2 1 13 12 11 10 9 8 7 - Vo - Vin Derating Curve NID100-5V NID100-12V,15V 100 90 80 70 60 50 40 30 20 -30 30<Vin≤50Vdc 50<Vin≤53Vdc 0 10 20 30 40 50 65 75 85 (VERTICAL) LOAD (%) LOAD (%) 20≤Vin≤30Vdc 10.5≤Vin≤30Vdc 30<Vin≤50Vdc 100 90 80 70 60 50 40 30 20 -30 50<Vin≤53Vdc 0 10 20 30 40 50 65 85 75 (VERTICAL) AMBIENT TEMPERATURE (℃) AMBIENT TEMPERATURE (℃) NID100-24V LOAD (%) 30≤Vin≤36Vdc 36<Vin≤50Vdc 100 90 80 70 60 50 40 30 20 -30 50<Vin≤53Vdc 0 10 20 30 40 50 65 75 85 (VERTICAL) AMBIENT TEMPERATURE (℃) File Name:NID100-SPEC 2022-09-20 100W DC-DC Non-Isolated Regulated Converter NID100 Mechanical Specification series Unit:mm(inch) 12[0.472]max. 9 [0.315] 27 . 5 [1.082] 4.5[0.18] 50.8 [2] 1 2 3 4 5 6 SIDE VIEW 7 8 9 1011 1213 1.3 [0.051] 0.64 [0.025] 25.4 [1] 10.2 [0.402] 4 [0.16] 2.54 [0.1] Pin Configuration Pin No. Pin_Out 1,2,3,4 5,6,7,8 9,10 11 12 + Vo u t Com + Vi n N.C. Tr i m ( o p t i o n a l ) 13 R.C. EMC Suggestion Circuit ※Comply to EN55032 Class A without additional componenets ,required external components to meet Class B emisssion are as below: L1 +Vin +Vin C1 + C2 + +V o NID100 -Vin GND C1/C2 L1 C3 120μF/63V 15μH(NiZn) 22μF/35V +V o C3 + Load -V o File Name:NID100-SPEC 2022-09-20
NID100-5 价格&库存

很抱歉,暂时无法提供与“NID100-5”相匹配的价格&库存,您可以联系我们找货

免费人工找货