0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ARX1212

ARX1212

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    RELAY RF SPDT 500MA 12V

  • 数据手册
  • 价格&库存
ARX1212 数据手册
RX SMALL MICRO WAVE RELAY RX-RELAYS • V.S.W.R./ Return loss: 1.2dB or less/ 20.8dB or more 2. High sensitivity • Nominal operating power: 200 mW 3. Small size • Size: 20.5(L) × 12.4(W) × 9.4(H) mm .807(L) × .488(W) × .370(H) inch • Insertion loss 20.5 .807 12.4 .488 Insertion loss, dB 9.4 .370 0 COM-NC 0.1 0.2 COM-NO 0.3 mm inch 1. Excellent high frequency characteristics (~2.5GHz, Impedance 50Ω) • Insertion loss: 0.2 dB or less • Isolation: 60 dB or more 0.4 0.5 300kHz 1.5GHz Frequency 2.5GHz3GHz *Also available for unit support (contact us for more details). SPECIFICATIONS Contact Arrangement Contact material Initial contact resistance Contact rating Rating Contact carrying power Max. switching voltage Max. switching current Isolation High frequency Insertion loss characteristics V.S.W.R.(Return loss) (~2.5GHz, Impedance 50Ω) Input power Mechanical (at 180 cpm) Expected life (min. operations) 10mA 24 V DC (resistive load) Electrical 10W 2.5 GHz, Impedance 50Ω 1 Form C Gold Max. 100 mΩ 10W (2.5 GHz, Impedance 50 Ω, V.S.W.R. 1.2) 10mA 24V DC(resistive load) Max. 20W(at 40°C, V.S.W.R. 1.2, Average) 30 V DC 0.5 A DC Min. 60 dB Max. 0.2 dB Max. 1.2 (Min. 20.8dB) Max. 20W (at 40°C, V.S.W.R. 1.2,Average) 5×106 3×105 105 Conditions for operation, transport and storage*8 Vibration resistance Shock resistance Characteristics Initial insulation resistance*1 Between open contacts Initial Between contact and coil breakdown 2 Between contact and voltage* earth terminal Operate time [Set time]*3 (at 20°C) Release time (without diode) [Reset time]*3 Temperature rise (at 20°C)*4 Functional*5 Destructive*6 Functional*7 Destructive Ambient temp. Min. 100 MΩ (at 500 V DC) 500 Vrms 1,000 Vrms 500 Vrms Max. 10ms (Approx. 6ms) [Max. 10ms (Approx. 5ms)] Max. 6ms (Approx. 3ms) [Max. 10ms (Approx. 5ms)] Max. 60°C Min. 200 m/s2 {20 G} Min. 1,000 m/s2 {100 G} 10 to 55 Hz at double amplitude of 3 mm 10 to 55 Hz at double amplitude of 5 mm –40°C to 60°C –40°F to 140°F 5 to 85% R.H. Approx. 5 g .18 oz (Not freezing and condensing Humidity at low temperature) Coil (at 20°C, 68°F) Nominal operating power Single side stable 1 coil latching 2 coil latching 200 mW 200 mW 400 mW Unit weight Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as “Initial breakdown voltage” section. *2 Detection current: 10mA *3 Nominal operating voltage applied to the coil, excluding contact bounce time. *4 By resistive method, nominal voltage applied to the coil: Contact carrying power: 20W, at 2.5GHz, Impedance 50Ω, V.S.W.R.&1.2 *5 Half-wave pulse of sine wave: 11ms, detection time: 10µs. 6 * Half-wave pulse of sine wave: 6ms *7 Detection time: 10µs *8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61) TYPICAL APPLICATIONS • Cellular phone base station (W-CDMA, FPLMTS, IMT-2000, PCS, DCS) • Cellular phone-related measurement devices (SP3T/SP4T switches, etc) • Wireless LAN • Wireless Local Loop 90 ORDERING INFORMATION Ex. A RX Contact arrangement 1: 1 Form C 1 0 Operating function 0: Single side stable 1: 1 coil latching 2: 2 coil latching 12 Coil voltage, V DC 03: 3 4H: 4.5 06: 6 09: 9 12: 12 24: 24 Product name RX Note: Standard packing; Carton: 50 pcs. Case 500 pcs. RX TYPES ANE COIL DATA (at 20°C 68°F) • Single side stable type Part No. ARX1003 ARX104H ARX1006 ARX1009 ARX1012 ARX1024 Nominal voltage, V DC 3 4.5 6 9 12 24 Pick-up voltage, V DC (max.)(initial) 2.25 3.375 4.5 6.75 9 18 Drop-out voltage, V DC (min.)(initial) 0.3 0.45 0.6 0.9 1.2 2.4 Coil resistance, Ω (±10%) 45 101 180 405 720 2,880 Nominal Nominal operating current, operating power, mA (±10%) mW 66.7 200 44.4 200 33.3 200 22.2 200 200 16.7 8.3 200 Max. allowable voltage, V DC 3.3 4.95 6.6 9.9 13.2 26.4 • 1 coil latching type Part No. ARX1103 ARX114H ARX1106 ARX1109 ARX1112 ARX1124 Nominal voltage, V DC 3 4.5 6 9 12 24 Set voltage, V DC (max.)(initial) 2.25 3.375 4.5 6.75 9 18 Reset voltage, V DC (max.)(initial) 2.25 3.375 4.5 6.75 9 18 Coil resistance, Ω (±10%) 45 101 180 405 720 2,880 Nominal Nominal operating current, operating power, mA (±10%) mW 200 66.7 200 44.4 200 33.3 200 22.2 200 16.7 200 8.3 Max. allowable voltage, V DC 3.3 4.95 6.6 9.9 13.2 26.4 • 2 coil latching type Part No. ARX1203 ARX124H ARX1206 ARX1209 ARX1212 ARX1224 Nominal voltage, V DC 3 4.5 6 9 12 24 Set voltage, V DC (max.)(initial) 2.25 3.375 4.5 6.75 9 18 Reset voltage, V DC (max.)(initial) 2.25 3.375 4.5 6.75 9 18 Coil resistance, Ω (±10%) 22.5 50.6 90 202.5 360 1,440 Nominal Nominal operating current, operating power, mA (±10%) mW 400 133.3 400 88.9 400 66.7 400 44.4 400 33.3 400 16.7 Max. allowable voltage, V DC 3.3 4.95 6.6 9.9 13.2 26.4 mm inch PC board pattern (Bottom view) 20.5 .807 12.4 .488 2.54 .100 0.9 dia hole .035 dia hole (2 coil latching type only) DIMENSIONS 9.2 .362 0.2 .008 2.63 .104 2.54 .100 3.0 .118 (2.04) (.080) 7.62 .300 (2.74) (.108) 7.62 .300 R 0.90 .035 0. 45 2-0.6×0.3 2-.024×.012 Tolerance: ±0.1 ±.004 General tolerance: ±0.3 ±.012 Solder to the PC board earth. Schematic (Bottom view) 7-0.40 to 0.45 dia. 7-.016 to .018 dia. Single side stable 1 7 1 coil latching 1 7 2 coil latching 1 6 7 14 13 12 11 10 9 NC COM 8 14 13 12 11 10 9 RESET COM 8 14 13 12 11 10 9 RESET COM 8 NO SET SET (Deenergized condition) (Reset condition) (Reset condition) 91 RX REFERENCE DATA 1. High frequency characteristics Sample: ARX1012 Measuring method: Measured with HP network analyzer (HP8753C). The details for the high freqency characteristics and the measurement procedures and conditions are listed in the RX relay test report. • Insertion loss 0 COM-NC Insertion loss, dB Return loss, dB 0.1 Isolation, dB 20 10 COM-NO 1.2 1.1 30 COM-NC 0.4 80 COM-NO 40 • Isolation 0 • V.S.W.R. (Return loss) 0 5.0 2.0 1.5 20 V.S.W.R. 0.2 COM-NO 0.3 40 COM-NC 60 0.5 300kHz 1.5GHz Frequency 2.5GHz3GHz 100 300kHz 50 1.5GHz Frequency 2.5GHz 3GHz 300kHz 1.5GHz Frequency 2.5GHz 3GHz NOTES 1. Coil operating power Pure DC current should be applied to the coil. The wave form should be rectangular. lf it includes ripple, the ripple factor should be less than 5%. However, check it with the actual circuit since the characteristics may be slightly different. The nominal operating voltage should be applied to the coil for more than 30 ms to set/reset the latching type relay. 2. Coil connection When connecting coils, refer to the wiring diagram to prevent mis-operation or malfunction. 3. External magnetic field Since RX relays are highly sensitive polarized relays, their characteristics will be affected by a strong external magnetic field. Avoid using the relay under that condition. 4. Cleaning For automatic cleaning, the boiling method is recommended. Avoid ultrasonic cleaning which subjects the relays to high frequency vibrations, which may cause the contacts to stick. lt is recommended that a fluorinated hydrocarbon or other alcoholic solvents be used. 5. Soldering The soldering shall be performed under following condition. Max. 260°C 500°F 10s Max. 350°C 662°F 3s In addition, when soldering the case to the PC board, the plating may swell depending on the soldering conditions. For Cautions for Use, see Relay Technical Information (Page 48 to 76). 2 9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog
ARX1212 价格&库存

很抱歉,暂时无法提供与“ARX1212”相匹配的价格&库存,您可以联系我们找货

免费人工找货