TV-8 rated.
1 Form A 5A power relays
RoHS compliant
Protective construction: Flux-resistant
type
LK-T RELAYS
FEATURES
TYPICAL APPLICATIONS
1. High inrush current capability
1) Operating load capability:
inrush 118 A, steady 8 A
2) UL/C-UL TV-8 approved
2. Long insulation distance
1) Creepage distance and clearances
between contact and coil: Min. 6 mm .236
inch (In compliance with IEC60065)
2) Surge withstand voltage between
contact and coil: 10,000 V or more
3. Conforms to the various safety
standards
UL/C-UL, TÜV, and SEMKO approved
• Audio visual equipment
• Flat TVs and audio equipment, etc.
• Office equipment
• Home appliances
ORDERING INFORMATION
LKT
1a
F
LK-T relay
Contact arrangement
1a: 1 Form A
Protective construction
F: Flux-resistant type
Nominal coil voltage (DC)
5V, 9V, 12V, 24V
Notes: Certified by UL/C-UL, TÜV and SEMKO
TYPES
Contact arrangement
1 Form A
Nominal coil voltage
5V DC
9V DC
12V DC
24V DC
Part No.
LKT1aF-5V
LKT1aF-9V
LKT1aF-12V
LKT1aF-24V
Standard packing Carton: 100 pcs. Case: 500 pcs.
Note: 3 V, 6 V and 18 V DC types are also available. Please consult us for details.
RATING
1. Coil data
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
70%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
50.0mA
27.8mA
20.8mA
10.4mA
100Ω
324Ω
576Ω
2,304Ω
5V DC
9V DC
12V DC
24V DC
–1–
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
250mW
6.5V DC
11.7V DC
15.6V DC
31.2V DC
ASCTB201E 201605-T
LK-T
2. Specifications
Characteristics
Contact
Rating
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Min. switching capacity (reference value)*1
Specifications
1 Form A
Max. 100 mΩ (By voltage drop 6 V DC 1A)
AgSnO2 type
5A 277V AC
1,385VA
277V AC
8A (AC)
100mA, 5V DC
Insulation resistance (Initial)
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Between open contacts
Between contact and coil
Surge breakdown voltage*2
(Between contact and coil) (Initial)
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
1,000 Vrms for 1 min. (Detection current: 10 mA)
4,000 Vrms for 1 min. (Detection current: 10 mA)
Breakdown voltage
(Initial)
Electrical
characteristics
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical (at 180 times/min.)
Electrical (at 20 times/min.)
Shock resistance
Mechanical
characteristics
Expected life
Conditions
Conditions for operation, transport and storage*3
Max. operating speed
10,000 V
Max. 15 ms (excluding contact bounce time.)
Max. 5 ms (excluding contact bounce time) (Without diode)
200 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 1.5 mm
Min. 106
Min. 105 (ON: 1.5s, OFF: 1.5s, at nominal switching capacity)
Ambient temperature: –40°C to +70°C –40°F to +158°F,
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature),
Air pressure: 86 to 106kPa
20 times/min. (at nominal switching capacity)
Approx. 12 g .42 oz
Unit weight
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
1. Max. switching power (AC resistive load)
2. Coil temperature rise
3. Ambient temperature characteristics and coil
applied voltage
Sample: LKT1aF-12V, 6 pcs.
Point measured: coil inside
Contact current: 0 A, 8A
100
30
300
Allowable ambient temperatures
against % coil voltages
(max. inside the coil temperature
set as 115°C 239°F)
10
5
1
25
70°C 8A
70°C 0A
20
15
10
Coil applied voltage, %V
Temperature rise, °C
Contact current, A
20°C 8A
20°C 0A
200
Carrying current: 8A
Pick-up voltage (hot start)
100
Pick-up voltage (cold start)
5
0
10
100
Contact voltage, V
4-(1). Electrical life test
(5 A 277 V AC, resistive load)
100
0
120
0
40
60
80
100
Ambient temperature, °C
120
50
45
10
Pick-up voltage
Max.
x
8
Min.
6
4
Drop-out voltage
Max.
x
Min.
2
0
0
5
No. of operations, ×10
–2–
10
4
Contact resistance, mΩ
Contact
welding
detection
and Miscontacting
detection
circuit
20
Change of contact resistance
12
Circuit:
12V DC
80
Change of pick-up and drop-out voltage
Sample: LKT1aF-12V, 6 pcs.
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: 20°C 68°F
277V AC
0
Coil applied voltage, %V
Pick-up and drop-out voltage, V
0
40
35
30
25
Max.
20
15
x
10
Min.
5
0
0
5
10
No. of operations, ×104
ASCTB201E 201605-T
LK-T
4-(2). Electrical life test
(UL508 TV-8 rating test)
Change of pick-up and drop-out voltage
Change of contact resistance
12
50
45
10
8
Pick-up voltage
Max.
x
Min.
6
4
Drop-out voltage
2
0
0
Max.
x
Min.
25
Contact resistance, mΩ
Pick-up and drop-out voltage, V
Sample: LKT1aF-12V, 6 pcs.
• Overload test
Load: 12 A 120 V AC (60 Hz),
Inductive load (cosφ = 0.75)
Operation frequency: 6 times/min
(ON : OFF = 1 s : 9 s)
No. of operations: 50 ope.
• Endurance test
Load: 8A 120 V AC (960 W lamp load),
(Inrush: 118 A)
Operation frequency: 1 times/min
(ON: OFF = 1 s: 59 s)
No. of operations: 25,000 ope.
40
35
30
25
20
15
Max.
x
Min.
10
5
0
0
25
No. of operations, ×103
DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
No. of operations, ×103
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
CAD Data
PC board pattern (Bottom view)
2-0.9 dia.
2-.035 dia.
16.5
.650
7.5
.295
Max. 25.0
.984
0.5
.020
0.5 dia.
.020 dia.
1.65
.065
Max. 24.0
.945
16.5
.650
20.0
.787
Tolerance: ±0.1 ±.004
4
.157
0.3
.012
2-1.3 dia.
2-.051 dia.
Schematic (Bottom view)
0.4
.016
Max. 11.0
.433
1.0
.039
7.5
.295
20.0
.787
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
General tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
SAFETY STANDARDS
File No.
E43149
File No.
1408509
UL/C-UL (Recognized)
Contact rating
8A 277V AC General use
5A 277V AC General use
5A 30V DC Resistive
SEMKO (Certified)
Contact rating
3/100A 250V AC
5/40A 250V AC
Cycles
5 × 104
105
105
File No.
40014390
File No.
E43149
VDE (Certified)
Contact rating
8A 250V AC (cosφ =1.0)
—
—
Cycles
2 × 104
—
—
File No.
B 12 09 13461 333
TÜV (Certified)
Contact rating
8A 250V AC (cosφ =1.0)
—
—
Cycles
2 × 104
—
—
TV Rating (UL/C-UL)
Contact rating
TV-8
—
* CSA standard: Certified by C-UL
EN/IEC VDE Certified
INSULATION CHARACTERISTIC(IEC61810-1)
Item
Clearance/Creepage distance (IEC61810-1)
Category of protection (IEC61810-1)
Tracking resistance (IEC60112)
Insulation material group
Over voltage category
Rated voltage
Pollution degree
Type of insulation (Between contact and coil)
Type of insulation (Between open contacts)
Characteristic
Min. 5.5mm/5.5mm
RT II
PTI 175
III a
III
250V
2
Reinforced insulation
Micro disconnection
–3–
ASCTB201E 201605-T
LK-T
NOTES
1. For cautions for use, please read
“GENERAL APPLICATION
GUIDELINES”.
–4–
ASCTB201E 201605-T